1.Biomechanical advantages of personalized Y-shaped plates in treatment of distal humeral intra-articular fractures.
Hao YU ; Jiachen PENG ; Jibin YANG ; Lidan YANG ; Zhi XU ; Chen YANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):574-583
OBJECTIVE:
To compare the biomechanical properties of personalized Y-shaped plates with horizontal plates, vertical plates, and traditional Y-shaped plates in the treatment of distal humeral intra-articular fractures through finite element analysis, and to evaluate their potential for clinical application.
METHODS:
The study selected a 38-year-old male volunteer and obtained a three-dimensional model of the humerus by scanning his upper limbs using a 64-slice spiral CT. Four types of fracture-internal fixation models were constructed using Mimics 19.0, Geomagic Wrap 2017, Creo 6.0, and other software: horizontal plates, vertical plates, traditional Y-shaped plate, and personalized Y-shaped plate. The models were then meshed using Hypermesh 14.0 software, and material properties and boundary conditions were defined in Abaqus 6.14 software. AnyBody 7.3 software was used to simulate elbow flexion and extension movements, calculate muscle strength, joint forces, and load torques, and compare the peak stress and maximum displacement of the four fixation methods at different motion angles (10°, 30°, 50°, 70°, 90°, 110°, 130°, 150°) during elbow flexion and extension.
RESULTS:
Under dynamic loading during elbow flexion and extension, the personalized Y-shaped plate exhibits significant biomechanical advantages. During elbow flexion, the peak internal fixation stress of the personalized Y-shaped plate was (28.8±0.9) MPa, which was significantly lower than that of the horizontal plates, vertical plates, and traditional Y-shaped plate ( P<0.05). During elbow extension, the peak internal fixation stress of the personalized Y-shaped plate was (18.1±1.6) MPa, which was lower than those of the other three models, with significant differences when compared with horizontal plates and vertical plates ( P<0.05). Regarding the peak humeral stress, the personalized Y-shaped plate model showed mean values of (10.9±0.8) and (13.1±1.4) MPa during elbow flexion and extension, respectively, which were significantly lower than those of the other three models ( P<0.05). Displacement analysis showed that the maximum displacement of the humerus with the personalized Y-shaped plate during elbow flexion was (2.03±0.08) mm, slightly higher than that of the horizontal plates, but significantly lower than that of the vertical plates, showing significant differences ( P<0.05). During elbow extension, the maximum displacement of the humerus with the personalized Y-shaped plate was (1.93±0.13) mm, which was lower than that of the other three models, with significant differences when compared with vertical plates and traditional Y-shaped plates ( P<0.05). Stress contour analysis showed that the stress of the personalized Y-shaped plate was primarily concentrated at the bifurcation of the Y-shaped structure. Displacement contour analysis showed that the personalized Y-shaped plate effectively controlled the displacement of the distal humerus during both flexion and extension, demonstrating excellent stability.
CONCLUSION
The personalized Y-shaped plate demonstrates excellent biomechanical performance in the treatment of distal humeral intra-articular fractures, with lower stress and displacement, providing more stable fixation effects.
Humans
;
Male
;
Adult
;
Healthy Volunteers
;
Finite Element Analysis
;
Tomography, Spiral Computed
;
Models, Anatomic
;
Biomechanical Phenomena
;
Humeral Fractures, Distal/surgery*
;
Fracture Fixation, Internal/instrumentation*
;
Bone Plates
;
Computer Simulation
;
Precision Medicine/methods*
;
Elbow Joint/surgery*
;
Elbow/surgery*
;
Humerus/surgery*
;
Torque
;
Stress, Mechanical
;
Intra-Articular Fractures/surgery*
;
Prosthesis Design/methods*
;
Imaging, Three-Dimensional
;
Range of Motion, Articular
2.Comparative study on accuracy of three imaging methods in diagnosis of subacromial impingement syndrome.
Linfeng ZI ; Hongfu JIN ; Jianwei ZHU ; Guoxu ZHANG ; Yao TONG ; Sijie CHEN ; Wenze SHAO ; Xin TANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1290-1295
OBJECTIVE:
To compare the diagnostic accuracy of supraspinatus muscle outlet X-ray film, oblique sagittal multislice helical CT (MSCT), and oblique sagittal MRI in the diagnosis of subacromial impingement syndrome (SIS).
METHODS:
A retrospective analysis was conducted on the imaging data of 106 patients diagnosed with SIS between January 2023 and December 2024. The cohort consisted of 32 males and 74 females, with ages ranging from 43 to 70 years (mean, 60.19 years). All patients underwent supraspinatus muscle outlet X-ray film, MSCT, and MRI scans, with MSCT further subjected to three-dimensional reconstruction. Two experienced radiologists independently evaluated the acromion morphology in each imaging modality using the Bigliani classification system. Inter-observer reliability was assessed via Kappa statistics. The CT three-dimensional reconstructions were used as the "gold standard". The overall consistency, Kappa values, sensitivity, and specificity of the three imaging modalities were calculated. Receiver operating characteristic (ROC) curves were plotted, and the area under the curve (AUC) was computed.
RESULTS:
The inter-observer reliability for supraspinatus muscle outlet X-ray film, oblique sagittal MSCT, and oblique sagittal MRI was moderate, with Kappa values of 0.62, 0.63, and 0.55, respectively. When compared to the CT three-dimensional reconstructions as the "gold standard", the overall consistency was 88.7% (94/106), 62.3% (66/106), and 58.5% (62/106), respectively. The supraspinatus muscle outlet X-ray film showed excellent consistency (Kappa=0.77), whereas the consistency of MSCT and MRI was lower (Kappa=0.34 and 0.29, respectively). In terms of diagnostic sensitivity and specificity, the supraspinatus muscle outlet X-ray film outperformed oblique sagittal MSCT and oblique sagittal MRI in distinguishing various acromion types. ROC analysis demonstrated that the AUC for the supraspinatus muscle outlet X-ray film was consistently higher than for oblique sagittal MSCT and oblique sagittal MRI, with the highest diagnostic performance observed for type Ⅲ hooked acromion (AUC=0.939).
CONCLUSION
Supraspinatus muscle outlet X-ray film provides the highest diagnostic accuracy for acromion classification in SIS patients, particularly in identifying type Ⅲ hooked acromion, which is strongly associated with SIS. Given its superior sensitivity and consistency, it should be considered the primary screening tool. MSCT and MRI serve as valuable supplementary modalities for complex cases and preoperative evaluation.
Humans
;
Middle Aged
;
Male
;
Female
;
Shoulder Impingement Syndrome/diagnostic imaging*
;
Magnetic Resonance Imaging/methods*
;
Retrospective Studies
;
Aged
;
Adult
;
Imaging, Three-Dimensional
;
Sensitivity and Specificity
;
Tomography, Spiral Computed/methods*
;
Multidetector Computed Tomography/methods*
;
Reproducibility of Results
3.Multidetector computed tomography angiography for diagnosis of traumatic aneurysms associated with penetrating head injuries.
Konstantin Nickolaevich BABICHEV ; Aleksandr Viktorovich SAVELLO ; Alla Vladimirovna ISAEVA ; Dmitrij Vladimirovich SVISTOV ; Igor' Anatol'evich MEN'KOV ; Dzhamaludin Magomedrasulovich ISAEV
Chinese Journal of Traumatology 2025;28(2):91-95
PURPOSE:
To analyze the diagnostic efficacy of computed tomography angiography compared to digital cerebral angiography for the diagnosis of traumatic aneurysms (TAs) associated with combat-related penetrating head injuries and propose the most suitable angiography protocol in this clinical context.
METHODS:
A retrospective analysis was conducted on patients admitted to the neurosurgical clinic for penetrating traumatic brain injuries between February, 2022 and July, 2024, for whom both cerebral multidetector computed tomography angiography (MCTA) and digital cerebral angiography (DCA) were available. The inclusion were patients (1) with penetrating head injuries, (2) with missile trajectory traverses through the Sylvian or great longitudinal fissure, (3) basal cisterns with/or major subarachnoid hemorrhage. The sensitivity, specificity, positive predictive value, and negative predictive value of MCTA were calculated. DCA was considered as the gold standard of diagnosis. The sensitivity, specificity, positive predictive value, and negative predictive value of MCTA were calculated. Descriptive statistics and nonparametric statistics were used to analyze the study results and their differences, respectively.
RESULTS:
A total of 40 patients with 45 TAs were included in the study. Of these, 26 patients (65.0%) were found to have aneurysms on MCTA. The median diameter of the aneurysms diagnosed by MCTA was 4.9 (3.6, 4.8) mm (range of 2.5 - 10.4 mm). However, the mean diameter of TAs not detected by MCTA but diagnosed by DCA was (3.0 ± 1.3) mm (range of 1.3 - 4.9 mm). MCTA demonstrated sensitivity and specificity of 35.5% and 99.5%, respectively, with positive and negative predictive values of 92.3% and 90.7%.
CONCLUSIONS
A low sensitivity of MCTA for the diagnosis of TAs associated with combat-related penetrating head injuries was reported. When MCTA is inconclusive in the setting of radiologic predictors of cerebral artery injury, DSA may be required.
Humans
;
Male
;
Retrospective Studies
;
Adult
;
Multidetector Computed Tomography/methods*
;
Intracranial Aneurysm/etiology*
;
Computed Tomography Angiography/methods*
;
Female
;
Head Injuries, Penetrating/diagnostic imaging*
;
Middle Aged
;
Cerebral Angiography/methods*
;
Predictive Value of Tests
;
Sensitivity and Specificity
;
Young Adult
4.Study on the method of automatically determining maxillary complex landmarks based on non-rigid registration algorithms.
Zi Xiang GAO ; Jing WANG ; Ao Nan WEN ; Yu Jia ZHU ; Qing Zhao QIN ; Yong WANG ; Yi Jiao ZHAO
Chinese Journal of Stomatology 2023;58(6):554-560
Objective: To explore an automatic landmarking method for anatomical landmarks in the three-dimensional (3D) data of the maxillary complex and preliminarily evaluate its reproducibility and accuracy. Methods: From June 2021 to December 2022, spiral CT data of 31 patients with relatively normal craniofacial morphology were selected from those who visited the Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology. The sample included 15 males and 16 females, with the age of (33.3±8.3) years. The maxillary complex was reconstructed in 3D using Mimics software, and the resulting 3D data of the maxillary complex was mesh-refined using Geomagic software. Two attending physicians and one associate chief physician manually landmarked the 31 maxillary complex datasets, determining 24 anatomical landmarks. The average values of the three expert landmarking results were used as the expert-defined landmarks. One case that conformed to the average 3D morphological characteristics of healthy individuals' craniofacial bones was selected as the template data, while the remaining 30 cases were used as target data. The open-source MeshMonk program (a non-rigid registration algorithm) was used to perform an initial alignment of the template and target data based on 4 landmarks (nasion, left and right zygomatic arch prominence, and anterior nasal spine). The template data was then deformed to the shape of the target data using a non-rigid registration algorithm, resulting in the deformed template data. Based on the unchanged index property of homonymous landmarks before and after deformation of the template data, the coordinates of each landmark in the deformed template data were automatically retrieved as the automatic landmarking coordinates of the homonymous landmarks in the target data, thus completing the automatic landmarking process. The automatic landmarking process for the 30 target data was repeated three times. The root-mean-square distance (RMSD) of the dense corresponding point pairs (approximately 25 000 pairs) between the deformed template data and the target data was calculated as the deformation error of the non-rigid registration algorithm, and the intra-class correlation coefficient (ICC) of the deformation error in the three repetitions was analyzed. The linear distances between the automatic landmarking results and the expert-defined landmarks for the 24 anatomical landmarks were calculated as the automatic landmarking errors, and the ICC values of the 3D coordinates in the three automatic landmarking repetitions were analyzed. Results: The average three-dimensional deviation (RMSD) between the deformed template data and the corresponding target data for the 30 cases was (0.70±0.09) mm, with an ICC value of 1.00 for the deformation error in the three repetitions of the non-rigid registration algorithm. The average automatic landmarking error for the 24 anatomical landmarks was (1.86±0.30) mm, with the smallest error at the anterior nasal spine (0.65±0.24) mm and the largest error at the left oribital (3.27±2.28) mm. The ICC values for the 3D coordinates in the three automatic landmarking repetitions were all 1.00. Conclusions: This study established an automatic landmarking method for three-dimensional data of the maxillary complex based on a non-rigid registration algorithm. The accuracy and repeatability of this method for landmarking normal maxillary complex 3D data were relatively good.
Male
;
Female
;
Humans
;
Adult
;
Imaging, Three-Dimensional/methods*
;
Reproducibility of Results
;
Algorithms
;
Software
;
Tomography, Spiral Computed
;
Anatomic Landmarks/anatomy & histology*
5.Analysis of Imaging Performance Standards of CBCT X-IGRT System Used in Radiotherapy.
Shibing XIE ; Peichen WANG ; Chunying JIAO ; Chengxin LIANG ; Xintao ZHANG ; Jiajie XIE
Chinese Journal of Medical Instrumentation 2023;47(6):608-611
This article briefly describes the imaging performance standards of the kilovolt X-ray image guidance system used in radiotherapy, analyzes the main aspects that should be considered in the image quality of X-IGRT system, and focuses on parameters that should be considered in the imaging performance evaluation criteria of the CBCT X-IGRT. The purpose is to sort out the imaging performance evaluation standards of kilovolt X-IGRT system, clarify the image quality requirements of X-IGRT equipment, and reach a consensus when evaluating the imaging performance of X-IGRT system.
Radiotherapy Planning, Computer-Assisted/methods*
;
Cone-Beam Computed Tomography/methods*
;
Spiral Cone-Beam Computed Tomography
;
Radiotherapy, Intensity-Modulated/methods*
;
Radiotherapy, Image-Guided/methods*
6.Low-dose Spiral Computed Tomography in Lung Cancer Screening.
Lingqin KONG ; Xiaomin ZHANG ; Xichuan LI ; Yanjun SU
Chinese Journal of Lung Cancer 2022;25(9):678-683
Lung cancer is one of the malignant tumors with the highest morbidity and mortality in the world. The low early diagnosis rate and poor prognosis of patients have caused serious social burden. Regular screening of high-risk population by low-dose spiral computed tomography (LDCT) can significantly improve the early diagnosis rate of lung cancer and bring new opportunities for the diagnosis and treatment of lung cancer. In recent years, LDCT lung cancer screening programs have been carried out in many countries around the world and achieved good results, but there are still some controversies in the selection of screening subjects, screening frequency, cost effectiveness and other aspects. In this paper, the key factors of LDCT lung cancer screening, screening effect, pulmonary nodule management and artificial intelligence contribution to the development of LDCT will be reviewed, and the application progress of LDCT in lung cancer screening will be discussed.
.
Artificial Intelligence
;
Early Detection of Cancer/methods*
;
Humans
;
Lung Neoplasms/diagnostic imaging*
;
Radiation Dosage
;
Tomography, Spiral Computed/methods*
7.Comparison of multislice spiral CT and MRI in diagnosis of occult fracture of knee joint with meniscus and ligament injury.
Qing-Lan YE ; Jing LI ; Jin-Dan HOU ; Lei CAI ; Xing XIONG ; Hai-Jiao WANG
China Journal of Orthopaedics and Traumatology 2022;35(10):967-970
OBJECTIVE:
To investigate the diagnostic value of multislice spiral CT (MSCT) and MRI in occult fracture of knee joint with meniscus and ligament injury.
METHODS:
From January 2020 to March 2021, 63 patients with knee occult fracture with meniscus and ligament injury, including 41 males and 22 females, aged from 21 to 67 years old, with an average of (44.35±8.77) years old, the course of disease ranged from 1 to 6 days, with an average of (4.64±1.75) days, the body mass index (BMI) was (19.85±2.78) kg/m2. MSCT and MRI data of 63 patients were collected and statistically analyzed to evaluage their diagnist value.
RESULTS:
The detection of MRI for occult knee fravtures with meniscus and ligament injury, joint cavity effusion, bone marrow edema, and articular surface injury were 100.00% (63/63), 95.24% (60/63), 42.86% (27/63) and 36.51% (23/63), respectively. The detection rates of MSCT were 49.21% (31/63), 41.27% (26/63), 0.00% (0/63) and 1.59% (1/63), respectively, significantly lwver than that of MRI (P<0.05). The diagnostic sensitivity, specificity and accuracy of MRI were significantly higher than those of MSCT(P<0.05).
CONCLUSION
The sensitivity, specificity and accuracy of magnetic resonance imaging in the diagnosis of occult fracture of knee joint with meniscus and ligament injury are significantly better than that of MSCT. MRI has higher accuracy in the diagnosis of peripheral tissue diseases such as joint cavity, articular surface and bone marrow, and can reduce the risk of clinical misdiagnosis.
Male
;
Female
;
Humans
;
Young Adult
;
Adult
;
Middle Aged
;
Aged
;
Tibial Meniscus Injuries/diagnostic imaging*
;
Fractures, Closed/diagnostic imaging*
;
Arthroscopy/methods*
;
Knee Injuries/diagnostic imaging*
;
Knee Joint/diagnostic imaging*
;
Magnetic Resonance Imaging/methods*
;
Ligaments
;
Meniscus
;
Tomography, Spiral Computed
;
Fractures, Bone
;
Anterior Cruciate Ligament Injuries
8.Analysis of lung cancer screening through low-dose spiral computed tomography among petroleum company staffs in Sichuan-Chongqing Area in 2020.
Ze Min HE ; Ke Ting LIU ; Hong Xu REN ; Qing Wei SHEN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2022;40(3):196-200
Objective: To provide scientific evidence for early lung cancer screening, to analyze the incidence of pulmonary nodules among petroleum company staffs in Sichuan-Chongqing Area. Methods: In January 2021 , 6002 petroleum company staffs in Sichuan-Chongqing Area which scanned by low-dose spiral computed tomography (LDCT) of chest in medical examination center in 2020 were retrospectively collected as objects. Their imaging and clinical data were collected. χ(2) test was used to analyze the differences in the detection rates of lung nodules and suspected lung cancer nodules among workers in petroleum company staffs of different genders, ages and types of work. Results: Among the 6002 objects, 3853 (64.2%) were male and 2149 (35.8%) were female, with an average age of (47.25±12.13) years old. A total of 431 cases (7.2%) of pulmonary nodules and 57 cases (0.9%) of suspected lung cancer nodules were detected. 45 cases were followed up with surgical treatment, and 41 cases (91.1%) of lung cancer were diagnosed by postoperative pathology. There were significant differences in the detection rates of pulmonary nodules and suspected lung cancer nodules between different age groups (χ(2)=51.23, 18.81 , P<0.001). The detection rates of pulmonary nodules in the age groups 51-60 years old and ≥61 years old were higher than those in the age groups≤40 years old and 41-50 years old (P<0.05). The detection rate of suspected lung cancer nodules in the age group≥ 61 years old was higher than those in the age groups≤40 years old, 41-50 years old and 51-60 years old (P< 0.05) . And the detection rate of suspected lung cancer pulmonary nodules in oil workers was higher than that of ordinary workers (P<0.05) . Among female objects, the detection rate of pulmonary nodules in oil workers was higher than that in ordinary workers (χ(2)=8.09, P=0.004) . The detection rate of pulmonary nodules in oil workers aged ≥61 years old was higher than ordinary workers (χ(2)=37.94, P<0.001) . Among male objects, the detection rate of suspected lung cancer pulmonary nodules in oil workers was higher than that in ordinary workers (χ(2)=8.42, P=0.004) . The detection rates of suspected lung cancer pulmonary nodules in oil workers aged 51-60 years old and ≥61 years old groups were higher than those of ordinary workers (χ(2)=4.70, 8.74; P=0.030, 0.003) . Conclusion: LDCT is suitable for early lung cancer screening for petroleum company staffs. During the clinical screening process, LDCT should be used as a routine physical examination item for petroleum workers older than 51 years old.
Adult
;
Early Detection of Cancer/methods*
;
Female
;
Humans
;
Lung Neoplasms/diagnosis*
;
Male
;
Mass Screening/methods*
;
Middle Aged
;
Multiple Pulmonary Nodules/diagnostic imaging*
;
Petroleum
;
Retrospective Studies
;
Tomography, Spiral Computed
9.Novel apical-to-femoral rail technique for horizontal aorta in transcatheter aortic valve replacement.
Xianbao LIU ; Hanyi DAI ; Lihan WANG ; Jiaqi FAN ; Jian'an WANG
Journal of Zhejiang University. Science. B 2022;23(7):613-616
Transcatheter aortic valve replacement (TAVR) has emerged as a viable treatment option for patients with severe aortic stenosis regardless of its surgical risk stratification (Otto et al., 2021). Aortic angulation is usually measured as the angle between the horizontal and the aortic annulus planes based on preprocedural multidetector computed tomography (MDCT) (Al-Lamee et al., 2011). Extremely horizontal aorta, defined as an aortic angulation greater than 70°, is an unfavorable anatomic structure that poses particular technical challenges for TAVR. Abramowitz et al. (2016) have proved that an extremely horizontal aorta increased the risk of procedural complications, such as lower device success rates, more moderate or even severe perivalvular leakage (PVL), and the need for second valve implantation. Because of the long stent frame, inflexibility, and non-steerability, it is challenging to pass the delivery system of self-expanding valves (SEVs) through an extremely horizontal aorta. As a result, patients with an extremely horizontal aorta have always been excluded from the clinical trials of TAVR, and transfemoral (TF)-TAVR with SEV is considered as an "off-label" use of TAVR (Adams et al., 2014; Kaneko et al., 2020). Herein, we present a technically difficult case, in which a patient with an extremely horizontal aorta underwent TF-TAVR with SEV by applying a unique apical-to-femoral rail strategy.
Aorta
;
Humans
;
Lower Extremity
;
Multidetector Computed Tomography
;
Transcatheter Aortic Valve Replacement
10.Low-dose helical CT projection data restoration using noise estimation.
Fa Wei HE ; Yong Bo WANG ; Xi TAO ; Man Man ZHU ; Zi Xuan HONG ; Zhao Ying BIAN ; Jian Hua MA
Journal of Southern Medical University 2022;42(6):849-859
OBJECTIVE:
To build a helical CT projection data restoration model at random low-dose levels.
METHODS:
We used a noise estimation module to achieve noise estimation and obtained a low-dose projection noise variance map, which was used to guide projection data recovery by the projection data restoration module. A filtering back-projection algorithm (FBP) was finally used to reconstruct the images. The 3D wavelet group residual dense network (3DWGRDN) was adopted to build the network architecture of the noise estimation and projection data restoration module using asymmetric loss and total variational regularization. For validation of the model, 1/10 and 1/15 of normal dose helical CT images were restored using the proposed model and 3 other restoration models (IRLNet, REDCNN and MWResNet), and the results were visually and quantitatively compared.
RESULTS:
Quantitative comparisons of the restored images showed that the proposed helical CT projection data restoration model increased the structural similarity index by 5.79% to 17.46% compared with the other restoration algorithms (P < 0.05). The image quality scores of the proposed method rated by clinical radiologists ranged from 7.19% to 17.38%, significantly higher than the other restoration algorithms (P < 0.05).
CONCLUSION
The proposed method can effectively suppress noises and reduce artifacts in the projection data at different low-dose levels while preserving the integrity of the edges and fine details of the reconstructed CT images.
Algorithms
;
Artifacts
;
Tomography, Spiral Computed
;
Tomography, X-Ray Computed/methods*

Result Analysis