1.New advances in the treatment of neonatal diabetes mellitus with sulfonylureas
Xiaoyan HU ; Jinbo XIANG ; Xiaoxia ZHU ; Zheng LI ; Tingting CAO ; Ting DING ; Ziran XU ; Jingbo LI ; Youjun YANG
China Pharmacy 2026;37(9):1236-1240
Neonatal diabetes mellitus (NDM) is a rare monogenic disorder primarily caused by insufficient insulin secretion resulting from mutations in the KCNJ11 and ABCC8 genes. Sulfonylureas, represented by glibenclamide, have become the standard therapy for this type of NDM by precisely closing the mutated ATP-sensitive potassium channels in pancreatic β cells, thereby restoring insulin secretion. Clinical studies confirm that sulfonylureas enable over 90% of patients to successfully transition from insulin to oral treatment, achieving long-term stable glycemic control and improving neurological outcomes to a certain extent. In terms of safety, severe hypoglycemia induced by sulfonylureas is relatively rare and gastrointestinal reactions are mild; moreover, sulfonylureas show good long-term tolerability, and have no adverse effects on child growth and development. In the future, by further refining the full-chain management pathway of “rapid genetic diagnosis-early intervention-specialized dosage forms-long-term follow-up”, the clinical application of sulfonylureas is expected to provide NDM patients with an optimized treatment regimen and maximize their health benefits.
2.Association of outdoor activity time and sleep duration with screening myopia in primary school students
LIU Xiaoling, LI Tingting, CAO Caiyun, YANG Feng, TAO Shuman, WU Xiaoyan, XU Shaojun, TAO Fangbiao
Chinese Journal of School Health 2026;47(2):279-282
Objective:
To explore the association of outdoor activity time and sleep duration with screening myopia in primary school students, so as to provide strategies for myopia prevention.
Methods:
Through a convenience sampling method, a survey was conducted among 4 248 primary school students aged 7-13 years from three primary schools in Xihu District, Nanchang City, Jiangxi Province from May to July, 2023. The average daily outdoor activity time and sleep duration on both weekdays and weekends were investigated in primary school students by using a self designed questionnaire. Uncorrected visual acuity tests and non cycloplegic autorefraction were measured by professional optometrists. Inter group comparisons were conducted using the Chi square test. Logistic regression model was used to analyze the association of outdoor activity time and sleep duration with screening myopia.
Results:
The detection rate of screening myopia in primary school students was 33.6%, with the rate in boys (32.0%) lower than that in girls (35.3%), and the difference was statistically significant ( χ 2=5.11, P =0.02). The analysis results of Logistic regression showed that after adjusting for factors such as gender, grade and parental education level, both average daily outdoor activity time <2 h on both weekdays and weekends ( OR =1.27, 95% CI =1.11-1.46) and sleep duration <10 h ( OR =1.17, 95% CI =1.01- 1.35 ), as well as their combined effect ( OR =1.57, 95% CI =1.25-1.98), were associated with an increased risk of screening myopia in primary school students(all P <0.05). Subgroup analysis results indicated that compared to boys ( OR =1.46, 95% CI = 1.07 -1.99), girls( OR =1.73, 95% CI =1.22-2.44) with insufficient outdoor activity time and sleep duration had a higher risk of screening myopia(both P <0.05).
Conclusions
There is a negative correlation of outdoor activity time and sleep duration with screening myopia in primary school students. Outdoor activity time and extending sleep duration should be increased to reduce the risk of myopia in primary school students.
3.Application of chitosan in repair and regeneration of oral hard and soft tissues
Zhuo WANG ; Panpan SUN ; Huanzhi CHENG ; Tingting CAO
Chinese Journal of Tissue Engineering Research 2026;30(2):459-468
BACKGROUND:Chitosan has a place in the biomedical field due to its good biological properties and unique physicochemical properties,especially in tissue engineering and drug delivery with good application prospects.OBJECTIVE:To summarize the research progress of the role of chitosan in the repair and regeneration of oral soft and hard tissues.METHODS:A computerized search of CNKI and PubMed databases was performed with the search terms"chitosan,oral mucosal diseases,periodontal diseases,tissue regeneration,bacteriostatic,drug carrier,wound healing"in Chinese and English.The search time limit was from 2010 to 2024.After screening according to the inclusion and exclusion criteria,88 articles were finally included for summary analysis.RESULTS AND CONCLUSION:Chitosan is a promising biomaterial in bone and pulp regeneration as it has the ability to stimulate the recruitment and adhesion of osteogenic progenitor cells and dental pulp stem cells.Chitosan prevents caries,periodontal disease,and candidiasis by inhibiting Streptococcus pyogenes,Porphyromonas gingivalis,and Candida in the oral cavity.Chitosan nanocomposites have higher stability,better biocompatibility,and slow-release properties of drugs and can be enhanced by combining with other chemical reagents to enhance their anticancer properties.Chitosan possesses drug delivery,antibacterial activity,hemostasis and wound healing,which in turn can block the erosion of wounds by saliva and oral flora,relieve pain,repair and promote wound healing.Chitosan promotes the deposition of calcified material,which is conducive to the remineralisation of enamel and dentin.
4.Application of chitosan in repair and regeneration of oral hard and soft tissues
Zhuo WANG ; Panpan SUN ; Huanzhi CHENG ; Tingting CAO
Chinese Journal of Tissue Engineering Research 2026;30(2):459-468
BACKGROUND:Chitosan has a place in the biomedical field due to its good biological properties and unique physicochemical properties,especially in tissue engineering and drug delivery with good application prospects.OBJECTIVE:To summarize the research progress of the role of chitosan in the repair and regeneration of oral soft and hard tissues.METHODS:A computerized search of CNKI and PubMed databases was performed with the search terms"chitosan,oral mucosal diseases,periodontal diseases,tissue regeneration,bacteriostatic,drug carrier,wound healing"in Chinese and English.The search time limit was from 2010 to 2024.After screening according to the inclusion and exclusion criteria,88 articles were finally included for summary analysis.RESULTS AND CONCLUSION:Chitosan is a promising biomaterial in bone and pulp regeneration as it has the ability to stimulate the recruitment and adhesion of osteogenic progenitor cells and dental pulp stem cells.Chitosan prevents caries,periodontal disease,and candidiasis by inhibiting Streptococcus pyogenes,Porphyromonas gingivalis,and Candida in the oral cavity.Chitosan nanocomposites have higher stability,better biocompatibility,and slow-release properties of drugs and can be enhanced by combining with other chemical reagents to enhance their anticancer properties.Chitosan possesses drug delivery,antibacterial activity,hemostasis and wound healing,which in turn can block the erosion of wounds by saliva and oral flora,relieve pain,repair and promote wound healing.Chitosan promotes the deposition of calcified material,which is conducive to the remineralisation of enamel and dentin.
5.Personalized GYROID condylar prosthesis:design and finite element analysis
Danyu LIU ; Tingting JIANG ; Zhixiu JIANG ; Yuchen JI ; Yilin CAO ; Lei WANG ; Yucheng SU ; Xinyu WANG
Chinese Journal of Tissue Engineering Research 2025;29(17):3548-3556
BACKGROUND:Currently,the mandibular joint prosthesis manufactured at home and abroad needs to rely on screws to fix the condylar part of the prosthesis during the replacement process,and the retention hole is reserved to facilitate the operation during the operation.However,due to the lack of personalized jaw design,the reattachment plate may not fit the jaw,resulting in screw loosening and dislocation.Therefore,personalized condylar prosthesis replacement is of great value in the repair of the temporomandibular joint.OBJECTIVE:To design a personalized condylar prosthesis with an internal GYROID for mandibular condylar repair and reconstruction.METHODS:The GYROID structure was selected in the Rhinoceros 7 software with the single cell size of 6 mm and the wall thickness of 0.2,0.3,0.4,0.5,0.6,0.7,0.8 mm.The mechanical properties of the GYROID structure were analyzed by finite element method.3D printing of GYROID structural test specimens with different wall thickness(0.2,0.3,0.4,0.5,0.6,0.7,and 0.8 mm)was performed to test the mechanical properties of the specimens through room temperature compression experiments.A wall thickness value conforming to the range of mandibular mechanical properties was selected through finite element analysis and room temperature compression test results.An adult male mandibular CT data were used for inverse modeling to design a condylar prosthesis with an internal GYROID.Finite element analysis was used to simulate the movement of the apical staggered position and the opposite-blade jaw position after condylar prosthesis replacement.RESULTS AND CONCLUSION:(1)The results of finite element analysis and room temperature compression experiment showed that the elastic modulus of the GYROID structure increased with the increase of wall thickness.The elastic modulus of the GYROID structure with wall thickness of 0.5-0.7 mm was within the range of the elastic modulus of the mandible(1.5-4.0 GPa).Therefore,the 6 mm monocellular GYROID structural model with a wall thickness of 0.6 mm was selected for the design of the condylar prosthesis.(2)The results of finite element analysis showed that the stress distribution of mandibular model was symmetrical.The stress distribution of the two types of occlusion was roughly the same,and the stress peak was not significantly different.The stress concentrated in the neck of the condylar prosthesis,and the stress on the replacement side was slightly larger than that on the healthy side.The maximum equivalent stress of the whole internal fixation model was 269.34 MPa,and the maximum equivalent stress of the screw was 20.14 MPa.The equivalent stress and equivalent strain values of the prosthesis were greater than that of the opposite edge jaw position when the tooth tip was interlaced.The equivalent stress and equivalent strain values of the screw were smaller than that of the opposite edge jaw position when the tooth tip was interlaced.(3)The results showed that the design and retention of the personalized GYROID condylar prosthesis were good,which was consistent with the mechanical conduction of the mandible.
6.Correlation between muscle synergy characteristics of the affected leg and gait stability during walking in patients undergoing anterior cruciate ligament reconstruction
Mengli WEI ; Yaping ZHONG ; Tingting YU ; Xilin TAN ; Sijia CAO
Chinese Journal of Tissue Engineering Research 2025;29(14):2899-2906
BACKGROUND:Existing studies have preliminarily summarized the potential association between muscle activity of the affected lower limb and gait stability during walking in patients undergoing anterior cruciate ligament reconstruction.However,there are some issues such as incomplete observation of muscle categories,incomplete observation of walking action phases,and failure to consider synergistic effects among multiple muscle groups,which urgently require further improvement in this study.OBJECTIVE:To monitor muscle synergy information of the affected leg during walking in patients undergoing anterior cruciate ligament reconstruction and to analyze the association between muscle synergy information and gait stability.METHODS:Twenty-four male patients aged(21.66±4.09)years undergoing anterior cruciate ligament reconstruction,were recruited.Electromyographic and center of pressure data were collected from the affected lower limb during walking.A non-negative matrix decomposition algorithm was used to extract the number of muscle synergic elements from the affected leg,the time spent in peak activation of each muscle synergic element,and the muscle relative weight indexes.Correlation analysis was then performed with the center of pressure indexes.RESULTS AND CONCLUSION:Six types of muscle synergies were identified in the affected leg.The number of muscle synergic elements showed no significant correlation with the distance and speed of lateral displacement of the center of pressure.Regarding the peak activation time of muscle synergic elements,synergic element 3 in the dominant gait loading response period showed a significant negative correlation with the lateral displacement distance of the center of pressure(r=-0.413,P=0.045)and a significant negative correlation with the lateral displacement velocity of the center of pressure(r=-0.470,P=0.020).The activation time of the remaining types of muscle synergic elements was not significantly related with patient's gait stability indices.In terms of muscle relative weights,the rectus femoris muscle of synergistic element 1 in the dominant gait loading response period showed a significant negative correlation with the lateral displacement distance of the center of pressure(r=-0.592,P=0.005)and a significant negative correlation with the lateral displacement speed of the center of pressure(r=-0.529,P=0.014).Additionally,the relative weight of the biceps femoris muscle of synergistic element 3 in the dominant gait loading response period showed a significant negative correlation with the lateral displacement distance of the center of pressure(r=-0.428,P=0.037).To conclude,the central system in patients undergoing anterior cruciate ligament reconstruction regulates the synergistic muscle activity of the affected leg during walking to enhance gait stability in two primary ways:by prolonging the activation time of the muscle synergists during the dominant loading response period and enhancing the activation of the quadriceps muscle,in order to enhance the control of eccentric contractions of the knee joint during the landing of the affected leg and improve the stability of the knee joint;and by increasing the activation of the biceps femoris muscle during the loading response period,which increases the degree of knee flexion and enhances the lower limb's cushioning function during the landing of the affected leg.
7.Biomechanical properties of Gyroid structured titanium bionic bone scaffolds for repairing segmental mandibular defects
Zhixiu JIANG ; Yuchen JI ; Danyu LIU ; Yilin CAO ; Tingting JIANG ; Yihan SONG ; Lei WANG ; Xinyu WANG
Chinese Journal of Tissue Engineering Research 2025;29(22):4621-4628
BACKGROUND:Porous structures based on triple periodic minimal surfaces are one of the most promising orthopedic biostructures,among which the Gyroid structure is characterized by high specific surface area,high permeability,and zero mean curvature.OBJECTIVE:To screen the wall thickness interval of TC4 bionic bone scaffolds with 4 mm single-cell Gyroid structure matching the elastic modulus range of cancellous bone of the mandible through finite element analysis combined with mechanical compression test testing.METHODS:The finite element model of the 4 mm single-cell Gyroid structure with different wall thickths(0.1,0.2,0.3,0.4,0.5,0.6,0.7,and 0.8 mm)was established.The equivalent elastic modulus of the Gyroid structure was analyzed,and the wall thickness interval of the Gyroid structure matching the elastic modulus range of the maxillary resinous bone was selected with different wall thicknesses of 0.2,0.3,0.4,0.5,0.6,and 0.7 mm,respectively.According to finite element analysis screening results,the material selected was Ti6Al4V.Selective laser melting was used to prepare 3D printed Gyroid structure specimens.The surface treatment was carried out by large-grained sand blasting and acid etching.The elastic modulus and compressive strength of the specimen were tested by mechanical compression experiment.RESULTS AND CONCLUSION:(1)The finite element analysis results showed that the equivalent elastic modulus of the Gyroid structure increased with the increase of wall thickness,and the equivalent elastic modulus of the Gyroid structure with wall thickness of 0.2-0.7 mm was within the range of the elastic modulus of the spongy bone of the mandible(1.5-4.0 GPa),which was used for 3D printing of the Gyroid structure specimen.(2)The mechanical compression test results showed that the elastic modulus and compressive strength of the Gyroid structural specimen increased with the increase of wall thickness,and the elastic modulus of the Gyroid structural specimen with wall thickness of 0.3-0.5 mm was within the range of the elastic modulus of the cancellous bone of the mandible.The compressive strength of the Gyroid specimen with 0.3-0.7 mm wall thickness was consistent with the mechanical properties of the mandible.(3)The results show that the Gyroid structure of 0.3-0.5 mm wall thickness is compatible with the range of elastic modulus of the mandible.
8.Surveillance for pneumonia of unknown etiology: current status, challenges, and implementation ways
Boer QI ; Qing WANG ; Ju WANG ; Tingting LI ; Yanlin CAO ; Rui SHEN ; Li QI ; Jiang LONG ; Weizhong YANG ; Luzhao FENG
Chinese Journal of Epidemiology 2025;46(5):914-920
The prevention and control of emerging and reemerging infectious diseases are crucial for national biosecurity, and surveillance and reporting of pneumonia of unknown etiology are main ways for the early detection of these diseases and mitigation of their severity. This paper summaries the surveillance methods for pneumonia of unknown etiology and emerging and reemerging infectious diseases globally, indicating that such surveillance is mainly conducted based on hospital. Western countries primarily combine active and passive surveillance while utilizing artificial intelligence technology to rapidly identify cases. China mainly use passive surveillance based on the surveillance system for pneumonia of unknown etiology, with the function of early warning in the identification of emerging infectious diseases, such as avian influenza. However, with the improvement in the surveillance system operation, the overlap with other surveillance disease systems, such as influenza, has occurred, and the improvements in case definition and operational protocol are needed. It is recommended to improve the specificity of the case definition, strenthen training in hospital staff, inclduing clinical workers and office workers, and formulate incentive mechanisms. It is necessary to emphasize the responsibility of clinicians as the main force for the detection and reporting of pneumonia of unknown etiology and emerging infectious diseases, improve the appilication of artifical intelligent technique and conduct multi-source surveillance, such as third-party testing.
9.Comparative study on the short-term efficacy of transanal natural orifice specimen extraction surgery and conventional laparoscopic surgery in left-sided colon cancer
Tingting FU ; Jingwen CHANG ; Yibo CAO ; Tiantian BAO ; Tianbao XIAO ; Jiang CHEN ; Jian PENG
China Journal of Endoscopy 2025;31(7):1-10
Objective To compare the short-term efficacy and safety of transanal natural orifice specimen extraction surgery(Ta-NOSES)and conventional laparoscopic surgery in left-sided colon cancer.Methods A retrospective analysis was conducted on the clinical data of 35 patients with left-sided colon cancer admitted to the anorectal department of the hospital from January 2018 to December 2019.According to the different surgical methods,the patients were divided into experimental group(15 cases)and control group(20 cases).The observation group underwent Ta-NOSES,and the control group underwent conventional laparoscopic surgery.The perioperative related indicators,postoperative complications,postoperative pain scores,postoperative defecation control,short-term postoperative quality of life scores and 5-year postoperative follow-up of the two groups of patients were compared.Results There was no statistically significant difference in the intraoperative blood loss,stoma status and the number of lymph node dissections between the two groups of patients(P>0.05).Moreover,no permanent stoma occurred in either group of patients.The operation time of the experimental group was longer than that of the control group,the first time to get out of bed and move around,the time of the first anal exhaust,the time of the first diet intake and the hospital stay were shorter than those of the control group,the hospitalization cost was significantly lower than that of the control group,the differences were statistically significant(P<0.05).On 1 and 3 days after operation,the VAS scores of the experimental group were significantly lower than those of the control group.At 3 days after operation,the VAS scores of the two groups were significantly lower than those at 1 day after operation,and the differences were statistically significant(P<0.05).There was a statistically significant difference in postoperative Kirwan anal function grading between two groups of patients(P<0.05),with the experimental group having a better grading(higher proportion of grade Ⅰ),the control group had poor grading(with a higher proportion of grades Ⅱ,Ⅲ,and Ⅳ).There was no statistically significant difference in postoperative complications between the two groups of patients(P>0.05).The scores of each item on the Short Form-36(SF-36)in the experimental group were higher than those in the control group at 10 and 20 days after surgery(P<0.05).There was no statistically significant difference in the scores of each item on the SF-36 between the two groups at 30 days after surgery(P>0.05).The distant recurrence rate after surgery in the experimental group was 26.7%,compared with 25.0%in the control group,the difference was not statistically significant(P>0.05).There were no tumor recurrence cases with the original incision site,rectal and intestinal cavity,pelvic cavity and other specimen removal routes in both groups.The 5-year survival rate of the experimental group was 73.3%,which was not statistically significantly different from that of the control group(70.0%)(P>0.05).Conclusion Ta-NOSES in the treatment of left-sided colon cancer can alleviate postoperative pain compared with conventional laparoscopic surgery,promote the recovery of postoperative gastrointestinal function,improve the utilization rate of medical resources,reduce the economic burden of patients,improve the short-term quality of life after surgery,and does not increase the risks of postoperative complications and tumor metastasis and recurrence.It is worthy of clinical promotion and application.
10.Design of customized Gyroid condylar prosthesis and finite element analysis of articular disc
Tingting JIANG ; Danyu LIU ; Zhixiu JIANG ; Yuchen JI ; Yilin CAO ; Yucheng SU ; Xinyu WANG
Chinese Journal of Tissue Engineering Research 2025;29(28):6003-6011
BACKGROUND:Condylar prosthesis replacement,as one of the surgical methods for the treatment of temporomandibular joint diseases,not only needs to restore the morphology and function,but also needs to ensure long-term stable application.OBJECTIVE:To design finite element analysis of a customized Gyroid condylar prosthesis.METHODS:Gyroid structure specimens with different wall thicknesses(250,350,450,550,650,and 750 μm)were designed by software.Finite element simulation compression experiments were carried out to test the elastic modulus of the specimens.The Gyroid structure wall thickness range that matches the elastic modulus of mandibular cancellous bone and whose pore size meets the osteogenesis conditions was screened out.This range was subdivided and Gyroid structure specimens were made using 3D printing technology.Mechanical compression experiments were carried out on a universal testing machine.The Gyroid structure wall thickness that meets the mechanical properties of mandibular bone,has an easier osteogenesis and a smaller strength was screened out by elastic modulus and compressive strength,and subsequent experiments were carried out.A three-dimensional model of a customized Gyroid condylar prosthesis was designed,and the finite element analysis of the blade jaw position and cusp interdigitation position of the model under natural occlusion was simulated.RESULTS AND CONCLUSION:(1)Finite element analysis results showed that with the increase of wall thickness,the elastic modulus of Gyroid structure specimens increased.The elastic modulus of Gyroid structure specimens with wall thickness of 350,450,550,650,and 750 μm matched the elastic modulus of mandibular cancellous bone.Since the subsequent experiments needed to be subdivided into groups and the pore size of the 550,650,and 750 μm wall thickness group(pore size 800-1 000 μm)was within the osteogenesis range.Gyroid structure specimens with wall thickness of 550,600,650,700,and 750μm were selected for mechanical compression experiments on a universal testing machine.(2)The results of mechanical compression experiments showed that with the increase of wall thickness,the elastic modulus and compressive strength of Gyroid structure specimens increased.The elastic modulus of Gyroid structure specimens with wall thickness of 550,600,and 650 μm was within the elastic modulus of the mandibular cancellous bone.Finally,the wall thickness of 650 μm and the pore size of 900 μm were selected to construct the three-dimensional model of the mandibular customized Gyroid condylar prosthesis.(3)The results of finite element analysis of three-dimensional model of the mandibular customized Gyroid condylar prosthesis showed that the stress of the articular disc in the edge-to-edge occlusion was mainly concentrated on the lower surface of the anterior middle band,and the stress of the articular disc in the interposition of tooth tips was mainly concentrated on the lateral surface of the lower surface.The maximum displacement and the maximum equivalent stress of the left and right articular discs in the edge-to-edge occlusion and the interposition of tooth tips were similar.The maximum displacement was 0.031,0.030,0.028,and 0.018 mm,and the maximum equivalent stress was 2.87,2.30,2.73,and 1.71 MPa,respectively.(4)The results showed that the Gyroid structure with a wall thickness of 650 μm was consistent with the mechanical properties of the mandible,which reduced the strength of the titanium alloy and reduced the damage of the articular disc caused by the customized Gyroid condylar prosthesis.


Result Analysis
Print
Save
E-mail