1.Disrupted aperiodic neural activity and differential cognitive correlates in patients with schizophrenia
Kexin ZHANG ; Yilin YUAN ; Tianhang ZHOU ; Tingfang WU ; Chunyu DU ; Chenmei XIE ; Weiran CHEN ; Jing WANG ; Xin YU
Chinese Mental Health Journal 2025;39(6):477-482
Objective:To explore the aperiodic components(1/f slopes)and their associations with cognitive impairment in patients with schizophrenia.Methods:Nineteen patients with schizophrenia according to the Interna-tional Statistical Classification of Diseases and Related Health Problem,Tenth Revision(ICD-10)and 21 normal controls were administrated the total Brief Assessment of Cognition in Schizophrenia(BACS)to measure the cogni-tive performance.The 5-minute eyes-closed and eyes-open resting EEG signals were collected and parameterized in-to aperiodic components(1/f slope).Finally,Pearson correlation was used to examine the relationships between the 1/f slope and cognition assessment scores.Results:The patients with schizophrenia had higher 1/f slope compared to HC on central location of scalp(P<0.05).The vocal memory scores showed a significantly positive relation with 1/f slopes in patients with schizophrenia(anterior location:r=-0.68,P<0.05;central location:r=-0.44,P<0.05),but a significantly negative relation in normal controls(anterior location:r=0.57,P<0.05;posterior lo-cation:r=0.54,P<0.05).Conclusion:The 1/f slopes of EEG in schizophrenia were steeper than normal control,suggesting its strong cognitive functional significance and complex mechanisms in schizophrenia.
2.Preparation and physicochemical properties of nano-silver acupuncture needles.
Wenfeng HAI ; Jiaxin LIU ; Yang LIU ; Tingfang BAI ; Xiaomei HAN ; Ying YING ; Suocai TONG ; Tegexi BAIYIN ; Yingsong CHEN
Chinese Acupuncture & Moxibustion 2025;45(5):568-576
OBJECTIVE:
To explore the preparation of nano-silver acupuncture needles and evaluate the appearance, structure and properties.
METHODS:
Stainless steel acupuncture needles were pretreated by polishing with sandpaper and cleaning with ultrapure water and absolute ethanol. As the working electrodes, the needles were placed in an electrolyte solution contained silver nitrate (AgNO3), potassium nitrate (KNO3), and polyvinylpyrrolidone (PVP); and the silver nanoparticles were deposited at a constant voltage of -0.2 V for 1 200 s. The heat-treatment was conducted at 600 ℃ for 15 min in an argon atmosphere to strengthen the adhesion between the nanoparticles and the substrate. The surface appearance and structure of nano-silver acupuncture needles were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS). The electrical conductivity, thermal conductivity and biocompatibility of the needles were evaluated. The cytotoxicity and biocompatibility of the sample were assessed using the CCK-8 assay. According to the national standard, Acupuncture Needles (GB 2024-2016), the other physicochemical performances of nano-silver acupuncture needles were tested.
RESULTS:
①By controlling the AgNO3 concentration and the molar ratio of AgNO3 to PVP, it was found that at an AgNO3 concentration of 2 mmol/L and a molar ratio of 5∶1, silver nanoparticles with the diameter of 50-100 nm, regular appearance, and uniform distribution were obtained. At a lower concentration, the size of silver nanoparticles was smaller and unevenly distributed particles, whereas a higher concentration tended to produce a dendritic structure. ②By sandpaper polishing, acid etching pretreatment, and heat-treatment at 600 ℃ under argon for 15 min, the adhesion of silver nanoparticles on the surface of the needle body was strengthened, and the simulated pig skin puncture test showed the intact coating without shedding. ③SEM found that the silver nanoparticles were uniformly deposited, forming a nanofilm approximately 1.5 μm thick; XRD analysis showed the diffraction peaks corresponding to cubic crystal silver (111), (200), (220) and (311); and XPS detected characteristic peaks of Ag 3d3/2 and Ag 3d5/2, confirming the successful deposition and good crystallinity of the silver nanoparticles. ④Resistivity measurements indicated that the nano-silver acupuncture needles exhibited a resistivity of approximately 0.15 Ω·cm, about three times lower than that of unmodified stainless steel needles. The infrared thermography demonstrated that their thermal conductivity was superior to that of traditional acupuncture needles. In vitro CCK-8 cytotoxicity assay showed that the nano-silver acupuncture needles had no adverse effects on human skin fibroblasts and possessed good biocompatibility. ⑤ The key parameters such as needle tip performance, hardness, and the adhesion between the needle body and handle were in compliance with the requirements in Acupuncture Needles (GB 2024-2016), ensuring a quality guarantee provided for clinical applications.
CONCLUSION
The preparation of nano-silver acupuncture needles effectively overcomes the insufficient toughness of traditional silver needles and improves the electrical and thermal conductivity of stainless acupuncture needles.
Silver/chemistry*
;
Needles
;
Acupuncture Therapy/instrumentation*
;
Metal Nanoparticles/chemistry*
;
Humans
;
Electric Conductivity
;
Animals
3.Prognostic value of ultrasound carotid plaque length in patients with coronary artery disease.
Wendong TANG ; Zhichao XU ; Tingfang ZHU ; Yawei YANG ; Jian NA ; Wei ZHANG ; Liang CHEN ; Zongjun LIU ; Ming FAN ; Zhifu GUO ; Xianxian ZHAO ; Yuan BAI ; Bili ZHANG ; Hailing ZHANG ; Pan LI
Chinese Medical Journal 2025;138(14):1755-1757
4.Disrupted aperiodic neural activity and differential cognitive correlates in patients with schizophrenia
Kexin ZHANG ; Yilin YUAN ; Tianhang ZHOU ; Tingfang WU ; Chunyu DU ; Chenmei XIE ; Weiran CHEN ; Jing WANG ; Xin YU
Chinese Mental Health Journal 2025;39(6):477-482
Objective:To explore the aperiodic components(1/f slopes)and their associations with cognitive impairment in patients with schizophrenia.Methods:Nineteen patients with schizophrenia according to the Interna-tional Statistical Classification of Diseases and Related Health Problem,Tenth Revision(ICD-10)and 21 normal controls were administrated the total Brief Assessment of Cognition in Schizophrenia(BACS)to measure the cogni-tive performance.The 5-minute eyes-closed and eyes-open resting EEG signals were collected and parameterized in-to aperiodic components(1/f slope).Finally,Pearson correlation was used to examine the relationships between the 1/f slope and cognition assessment scores.Results:The patients with schizophrenia had higher 1/f slope compared to HC on central location of scalp(P<0.05).The vocal memory scores showed a significantly positive relation with 1/f slopes in patients with schizophrenia(anterior location:r=-0.68,P<0.05;central location:r=-0.44,P<0.05),but a significantly negative relation in normal controls(anterior location:r=0.57,P<0.05;posterior lo-cation:r=0.54,P<0.05).Conclusion:The 1/f slopes of EEG in schizophrenia were steeper than normal control,suggesting its strong cognitive functional significance and complex mechanisms in schizophrenia.
5.Research progress on influencing factors and countermeasures of scientific research outputs among medical personnel
Xin CHEN ; Liyan LONG ; Lei ZHANG ; Jiajun DU ; Tingfang LIU
Modern Hospital 2025;25(3):476-479
As the main body of scientific research and innovation in hospitals,timely understanding of medical person-nel's scientific research outputs and its influencing factors has practical guiding significance for hospital management to identify scientific research talents,formulate targeted training programs,customize relevant science and technology policies,etc.This ar-ticle will comprehensively elaborate the concept of scientific research outputs,evaluation methods and influencing factors of scien-tific research outputs among medical personnel.Meanwhile,the article will provide suggestions for influencing factors,in order to provide references for the hospital management in the future.
6.Research progress on influencing factors and countermeasures of scientific research outputs among medical personnel
Xin CHEN ; Liyan LONG ; Lei ZHANG ; Jiajun DU ; Tingfang LIU
Modern Hospital 2025;25(3):476-479
As the main body of scientific research and innovation in hospitals,timely understanding of medical person-nel's scientific research outputs and its influencing factors has practical guiding significance for hospital management to identify scientific research talents,formulate targeted training programs,customize relevant science and technology policies,etc.This ar-ticle will comprehensively elaborate the concept of scientific research outputs,evaluation methods and influencing factors of scien-tific research outputs among medical personnel.Meanwhile,the article will provide suggestions for influencing factors,in order to provide references for the hospital management in the future.
7.Minimally invasive treatment of unstable pelvic fractures with blunt head technique of Kirschner wire and 3D-printed external template technigue
Yizhou WAN ; Kaifang CHEN ; Sheng YAO ; Yulong WANG ; Lian ZENG ; Tingfang SUN ; Xiaodong GUO
Chinese Journal of Orthopaedic Trauma 2022;24(12):1024-1029
Objective:To explore the safety and efficacy of the minimally invasive treatment of unstable pelvic fractures with the blunt head technique of Kirschner wire and 3D-printed external template technique.Methods:A retrospective study was conducted of the clinical data of 21 patients with unstable pelvic fracture who had undergone minimally invasive treatment at Department of Orthopaedics, Union Hospital from May 2016 to July 2018 using 3D-printed external templates and the blunt head technique of Kirschner wire. There were 7 males and 14 females with an age of 43.6 years (from 19 to 65 years). According to the Tile classification, there were 3 cases of B1, 7 ones of B2, 6 ones of C1 and 5 ones of C2. The intraoperative fluoroscopy, operation time, postoperative fracture reduction and functional recovery of the pelvis at the last follow-up were recorded.Results:The 21 patients were followed up for an average of 16.3 months (from 12 to 24 months). A total of 33 wires were inserted in the 21 patients, including 15 S 1 ones and 18 S 2 ones. The intraoperative fluoroscopy ranged from 13 to 27 times, averaging 21.8 times. The operation time ranged from 65 to 130 min, averaging 88.6 min. The anterior subcutaneous internal fixation was used to fix the anterior ring in 9 patients. No vascular injury occurred during the operation. By the Matta criteria, the postoperative fracture reduction was assessed as excellent in 14 cases, good in 5, and fair in 2, giving an excellent to good rate of 90.5% (19/21). By the Majeed scoring system, the pelvic function at the last follow-up was assessed as excellent in 10 cases, good in 8, and fair in 3, giving an excellent to good rate of 85.7% (18/21). Lateral femoral cutaneous nerve injury occurred in 2 patients but was recovered by the 3-month follow-up. No other complications were follwed up. Conclusion:The minimally invasive treatment of unstable pelvic fractures with the blunt head technique of Kirschner wire assissted by 3D-printed external templates is safe and effective, showing advatages of reduced fluoroscopic frequency and operation time.
8.The supra-pectineal quadrilateral surface buttress plate for the treatment of complex acetabular fractures
Kaifang CHEN ; Sheng YAO ; Yizhou WAN ; Lian ZENG ; Fengzhao ZHU ; Zekang XIONG ; Liang YANG ; Jinge ZHOU ; Tingfang SUN ; Xiaodong GUO
Chinese Journal of Orthopaedics 2020;40(5):294-301
Objective:To introduce a novel anatomical supra-pectineal quadrilateral surface buttress plate, and explore its advantages, disadvantages and clinical efficacy in the treatment of complex acetabular fractures.Methods:Data of eighteen cases of acetabular fractures treated in our department from March 2017 to March 2019were retrospectively analyzed. There were 15 males and 3 females with an average age of 49.6 years (range, 27-62 years). According to the Letournel-Judet’s classification, there were 3 cases of anterior column fractures (involving quadrilateral surface), 2 cases of "T" shaped, 8 of cases anterior column and posterior hemi-transverse (ACPHT) and 5 cases of double columns fractures. The time from injury to operation was 5-14 days (mean, 7 days). Before operation, all patients were taken pelvic anterior-posterior X-ray and CT scan. All patients were adopted supra-ilioinguinal approach and fixed by supra-pectineal quadrilateral surface buttress plate. Surgical time, intraoperative blood loss and postoperative complications were collected. After operations all patients were taken pelvic X-ray in anterior-posterior and Judet position, as well as CT scan. The radiographic quality of reduction was evaluated by Matta criteria and hip functions were evaluated by Matta Modified Merle d’Aubigné-Postel scoring system.Results:The average surgical time was 130 min (range, 100-200 min). The average blood loss was 560 ml (range, 400-900 ml). An additional shaping was unnecessary in 18 patients who were implanted with the anatomical supra-pectineal quadrilateral surface buttress plate and all patients were operated successfully. All patients were followed up for an average time of 9 months (range, 6-15 months). The quality of fracture reduction was evaluated according to Matta standard, of which there were 11 cases excellent, 4 cases good, and 3 cases poor, with an excellent rate of 83.3% (15/18). At the latest follow-up, the function of the hip joint was evaluated according to the Matta Modified Merle d’Aubigné-Postel scoring system for a mean of 15.8 scores (range, 12-18 scores), of which there were 10 cases excellent, 6 cases good, 2 cases fair, with an excellent rate of 88.9% (16/18). All patients recovered well, and there were 2 cases of lateral femoral cutaneous nerve injury postoperative who had recovered one month later. There was no other postoperative complications.Conclusion:The anterior and posterior column and quadrilateral surface could be stabilized simultaneously by the anatomical supra-pectineal quadrilateral surface buttress plate without intraoperative shaping. Moreover, it is more likely to obtain a satisfactory clinical outcome by using this special plate with lower complications and rigid fixation. Therefore, it is a kind of internal fixation method worthy of promotion in the treatment of complex acetabular fractures.
9.Application of a novel acetabulum anatomic locking plate in treatment of anterior wall and anterior column acetabular fractures
Zhenfei HUANG ; Kaifang CHEN ; Lingjia YU ; Tingfang SUN ; Zekang XIONG ; Xiaodong GUO
Chinese Journal of Trauma 2018;34(3):214-219
Objective To investigate the clinical efficacy of a novel acetabulum anatomic locking plate in the treatment of anterior wall and anterior column acetabular fracture.Methods A retrospective case series study was performed in five patients with anterior wall and anterior column acetabular fractures managed operatively using a novel acetabulum anatomic locking plate from March 2014 to January 2016.There were four males and one female,with an average age of 41.1 years (range,25-65 years).The mean time from injury to operation was 3.2 days (range,2-5 days).All patients were managed operatively using the superior ilioinguinal approach.Operation duration,intraoperative blood loss,blood transfusion,and bony union time were recorded.The image results by Matta standard were evaluated and the acetabular function after operation was assessed by modified Merle d'Aubigné-Postel.Postoperative complications were recorded.Results All patients were followed up for average 15.3 months (range,12-24 months).The average operation duration was 96 minutes (range,60-130 minutes) and average blood loss was 230 ml (range,100-800 ml).Autologous blood transfusion was selectively used except for one patient with allogeneic blood transfusion of 400 ml.The mean time of bony union was 2.9 months (range,2-5 months).According to the Matta criteria,four patients attained anatomical reduction,and unsatisfactory reduction was reported in one patient.Clinical outcomes (Merled'Aubigné-Postel) at 12 months were 100% excellent with the average score of 17.1 (range,15-18).One patient had a lateral cutaneous nerve palsy,and symptom relief was seen after a follow up of 6 months.After operation,no complications such as surgical site infection,femoral head avascular necrosis,andtraumatic arthritis occurred in any patient.Conclusion The novel acetabulum anatomic locking platecan provide rigid and firm fixation for both anterior wall and anterior acetabular fractures using one singleplate,and the fracture reduction and function recovery are satisfactory.
10.Combined acetabular quadrilateral surface plates for the treatment of both column fractures
Kaifang CHEN ; Fan YANG ; Xiaodong GUO ; Zekang XIONG ; Sheng YAO ; Fengzhao ZHU ; Deepak DREPAUL ; Tingfang SUN ; Yanhui JI
Chinese Journal of Orthopaedics 2018;38(5):295-300
Objective To explore the clinical effectiveness and reliability of combined acetabular quadrilateral surface plates for the treatment of both column fractures.Methods From June 2016 to August 2017,data of 15 cases with acetabular both column fractures who were treated in our department were retrospectively analyzed.Among them 9 cases were male and 6 were female.The mean age was 42.8 years (range,26-68 years).All cases were both column fractures according to the LetournelJudet's classification,including 4 cases combined with posterior wall fracture.Before operation,the pelvic CT thin layer scanning data of patients were collected in DICOM format,and then the data were imported to print the simulated model by 3D printing technology in order to understand the characteristics of fracture directly.The contralateral half pelvis was mirror printed in order to simulate the placement of combined quadrilateral surface plates and preshape all plates.During operation,infrapectineal main plate,pubo-ischiatic plate and ilio-ischiatic plate were placed consequently to fix the anterior column,"middle column" and posterior column respectively.The pubo-ischiatic and ilio-ischiatic plates were combined with the main plate.All cases were operated by supra-ilioinguinal approach.Results The average incision length was 11 cm (range,9-13 cm).The average operative time was 150 min (range,100-240 min).The average blood loss was 850 ml (range,600-1500 ml).Once reduction was obtained,plates could be placed easily and adhere to bone surface well.The quality of postoperative fracture reduction was evaluated according to Matta standard,of which there were 9 cases excellent,4 cases good,and 2 cases poor,with an excellent rate of 86.7% (13/15).All patients were followed up for an average time of 10 months (range,6-12 months).At the latest follow-up,the average modified Merle d'Aubigne and Postel score was 16.4 (range,12-18),and there were 8 cases excellent,4 cases good,2 cases fair and 1 case poor,with an excellent rate of 80.0% (12/15).Conclusion For the treatment of acetabular both column fractures,the combined quadrilateral surface plates could resist the medial displacement of quadrilateral area,and on the other hand the total floating posterior column and ischium could be fixed firmly.At the same time,this plate system is a multi-dimensional framework fixation,which is more effective and safer with lower complications rate,resulting in a satisfactory clinical outcomes.

Result Analysis
Print
Save
E-mail