1.Application of intermediate screw assisted reduction and fixation technique in treatment of Schatzker type Ⅴ and Ⅵ tibial plateau fractures.
Zhaodong WANG ; Keyou DUAN ; Yajun LIU ; Chen XU ; Zhonglian ZHU ; Pinghui ZHOU ; Jianzhong GUAN
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):529-535
OBJECTIVE:
To explore effectiveness of intermediate screw assisted reduction and fixation technique in the treatment of Schatzker type Ⅴ and Ⅵ tibial plateau fractures.
METHODS:
A clinical data of 22 patients with Schatzker type Ⅴ and Ⅵ tibial plateau fractures, who were admitted between June 2022 and December 2023 and met the selection criteria, was retrospectively analyzed. During operation, the intermediate screw assisted reduction and fixation technique was used. There were 14 males and 8 females with an average age of 46.3 years (range, 17-65 years). The fractures were caused by traffic accident in 13 cases, by falls in 5 cases, and by falling from height in 4 cases. According to Schatzker classification criteria, 9 cases were type Ⅴ and 13 cases were type Ⅵ. The interval between injury and operation was 5-12 days (mean, 7.9 days). The operation time, intraoperative fluoroscopy times, and length of hospital stay were recorded. The range of motion of knee joint and Hospital for Special Surgery (HSS) score were recorded at last follow-up. X-ray films were taken to review the fracture healing. Rasmussen score, tibial plateau varus angle (TPVA), and posterior tibial slope (PTS) were estimated before operation, at immediate after operation, and at last follow-up in order to evaluate the fracture reduction effect and postoperative outcome.
RESULTS:
The operation time was 85-140 minutes (mean, 103.9 minutes). Intraoperative fluoroscopy was performed 7-15 times (mean, 10.1 times). All incisions healed by first intention after operation, and no complication such as nerve or blood vessel injury occurred. The length of hospital stay ranged from 8 to 17 days (mean, 12.4 days). All patients were followed up 10-22 months (mean, 14.8 months). At last follow-up, the range of motion of knee joint was 110°-140° (mean, 125°). HSS score was rated as excellent in 16 cases, good in 5 cases, and fair in 1 case, with an excellent and good rate of 95.5%. X-ray films reexamination showed that all fractures healed with the healing time of 12-17 weeks (mean, 14.8 weeks). No internal fixation failure occurred. Rasmussen score, TPVA, and PTS at immediate after operation and at last follow-up were significantly superior to those before operation ( P<0.05). And there was no significant difference between immediately after operation and last follow-up ( P>0.05).
CONCLUSION
The treatment of Schatzker type Ⅴ and Ⅵ tibial plateau fractures with intermediate screw assisted reduction and fixation technique is reliable, which can reduce the difficulty of reduction and fixation, improve the efficiency of reduction and fixation, reduce the operation time, achieve satisfactory reduction and fixation effect and postoperative prognosis, and achieve good recovery of knee joint function.
Humans
;
Tibial Fractures/diagnostic imaging*
;
Male
;
Female
;
Adult
;
Middle Aged
;
Bone Screws
;
Fracture Fixation, Internal/instrumentation*
;
Retrospective Studies
;
Adolescent
;
Aged
;
Young Adult
;
Treatment Outcome
;
Range of Motion, Articular
;
Operative Time
;
Length of Stay
;
Tibial Plateau Fractures
2.Application of minimally invasive techniques in clinical treatment of tibial plateau fractures.
Zhongzheng WANG ; Zhanle ZHENG ; Yingze ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(7):783-788
OBJECTIVE:
To review and evaluate the advantages and disadvantages of minimally invasive treatment techniques for tibial plateau fractures (TPFs), as well as the research progress and limitations.
METHODS:
The relevant domestic and international research literature on the minimally invasive treatment of TPFs in recent years was reviewed. The advantages, disadvantages, and clinical efficacy of various technologies were summarized and analyzed, and an outlook on future development trends was provided.
RESULTS:
Surgery remains the primary method for treating displaced TPFs. Although traditional open reduction and internal fixation has advantages such as direct reduction and simplicity of procedure, it has gradually fallen out of favor with clinical orthopedic doctors due to extensive soft tissue removal, excessive bleeding, tissue adhesion, and postoperative complications such as skin infection, fracture nonunion, and joint dysfunction. As medical technology continues to develop, minimally invasive surgery and precise diagnosis and treatment are gradually being introduced to orthopedic trauma. Guided by concepts such as "minimally invasive treatment", "homeopathic repositioning of fractures", and "internal compression fixation", many traction reduction devices, internal fixation devices, minimally invasive reduction techniques, and computer-aided navigation technologies have been widely used in the clinical treatment of TPFs. This has greatly helped to overcome the challenges of intraoperative reduction, secondary reduction loss, and postoperative functional impairment and effectively promoting the adoption of minimally invasive treatment techniques in the clinical treatment of TPFs.
CONCLUSION
Minimally invasive treatment techniques have made significant progress in the clinical treatment of TPFs, particularly with regard to the reduction, and have demonstrated unique advantages. While relevant research results have received international recognition, there is still a need for orthopedic scholars to conduct real-world research to further explore the underlying principles and mechanisms of action.
Humans
;
Minimally Invasive Surgical Procedures/instrumentation*
;
Tibial Fractures/surgery*
;
Fracture Fixation, Internal/instrumentation*
;
Tibial Plateau Fractures
3.Effectiveness analysis of Zhang's double reverse traction reducer in minimally invasive treatment of bilateral tibial plateau fractures.
Zhanle ZHENG ; Baoheng FAN ; Zhongzheng WANG ; Rongqing REN ; Yiyang WANG ; Ning WEI ; Yingze ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(7):789-794
OBJECTIVE:
To evaluate the effectiveness and safety of minimally invasive treatment for bilateral tibial plateau fractures using the double reverse traction reducer.
METHODS:
The clinical data of 4 patients with bilateral tibial plateau fractures who met the selection criteria and treated between January 2016 and April 2024 were retrospectively analyzed. The cohort included 3 males and 1 female, aged 30-65 years (mean, 52.5 years). Injury mechanisms comprised traffic accidents (2 cases) and falls (2 cases). According to the Schatzker classification, 2 limbs were type Ⅱ and 6 were type Ⅵ. The time from injury to surgery ranged from 5 to 9 days (mean, 7 days). All patients underwent minimally invasive reduction using the double reverse traction reducer. Surgical duration, intraoperative blood loss, and hospitalization time were recorded. Functional outcomes were assessed at last follow-up using the Hospital for Special Surgery (HSS) knee score and range of motion (ROM), while fracture reduction quality was evaluated using the Rasmussen radiological score.
RESULTS:
All 4 patients successfully completed the procedure without conversion to open reduction. The total mean operation time was 80.25 minutes (range, 73-86 minutes), with a mean total intraoperative blood loss of 132.5 mL (range, 100-150 mL). The mean hospitalization time was 13.5 days (range, 11-16 days). All incisions healed primarily without neurovascular complications. X-ray film at 1 day after operation confirmed satisfactory reduction and articular surface alignment. Follow-up time ranged from 12 to 26 months (mean, 17.0 months). Fractures achieved clinical union at an average of 13 weeks (range, 12-16 weeks). No complication, such as deep vein thrombosis, joint stiffness, post-traumatic arthritis, or implant failure, was observed. At last follow-up, the mean HSS score was 92.9 (range, 90-97), mean knee ROM was 128.1° (range, 115°-135°), and mean Rasmussen radiological score was 16.4 (range, 15-19), with 2 limbs rated as excellent and 6 as good.
CONCLUSION
The double reverse traction reducer facilitates minimally invasive treatment of bilateral tibial plateau fractures with advantages including minimal trauma, shorter surgical duration, precise reduction, and fewer complications, effectively promoting fracture healing and functional recovery of the knee joint.
Humans
;
Tibial Fractures/diagnostic imaging*
;
Middle Aged
;
Male
;
Minimally Invasive Surgical Procedures/instrumentation*
;
Female
;
Adult
;
Retrospective Studies
;
Aged
;
Traction/methods*
;
Treatment Outcome
;
Fracture Fixation, Internal/instrumentation*
;
Range of Motion, Articular
;
Operative Time
;
Tibial Plateau Fractures
4.Comparative study on effectiveness of double reverse traction reduction versus open reduction internal fixation in treating complex tibial plateau fractures.
Hao LIU ; Zhihao LIN ; Yueyan MA ; Haifeng GONG ; Tianrui WANG ; Fagang YE ; Yanling HU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(7):795-800
OBJECTIVE:
To compare the effectiveness and advantages of the double reverse traction reduction versus open reduction internal fixation for treating complex tibial plateau fractures.
METHODS:
A clinical data of 25 patients with Schatzker type Ⅴ or Ⅵ tibial plateau fractures, who met the selection criteria and were admitted between January 2019 and January 2023, was retrospectively analyzed. Thirteen patients underwent double reverse traction reduction and internal fixation (double reverse traction group), while 12 patients underwent open reduction and internal fixation (traditional open group). There was no significant difference in the baseline data (age, gender, injury mechanism, Schatzker classification, interval between injury and operation) between the two groups ( P>0.05). The effectiveness were evaluated and compared between the two groups, included operation time, intraoperative blood loss, incision length, hospital stay, full weight-bearing time, complications, fracture healing, Rasmussen radiological score (reduction quality), knee Hospital for Special Surgery (HSS) score, and knee flexion/extension range of motion.
RESULTS:
The double reverse traction group demonstrated significantly superior outcomes in operation time, intraoperative blood loss, hospital stay, incision length, and time to full weight-bearing ( P<0.05). Two patients in traditional open group developed incisional complications, while the double reverse traction group had no complication. There was no significant difference in the incidence of complication between the two groups ( P>0.05). All patients were followed up 24-36 months (mean, 30 months), with no significant difference in follow-up duration between groups ( P>0.05). Fractures healed in both groups with no significant difference in healing time ( P>0.05). At 6 months after operation, Rasmussen radiological scores and grading showed no significant difference between the two groups ( P>0.05); the double reverse traction group had significantly higher HSS scores compared to the traditional open group ( P<0.05). At 12 months after operation, knee flexion/extension range of motion were significantly greater in the double reverse traction group than in the traditional open group ( P<0.05).
CONCLUSION
Double reverse traction reduction offers advantages over traditional open reduction, including shorter operation time, reduced blood loss, minimized soft tissue trauma, and improved joint functional recovery. It is a safe and reliable method for complex tibial plateau fractures.
Humans
;
Tibial Fractures/surgery*
;
Fracture Fixation, Internal/methods*
;
Male
;
Female
;
Traction/methods*
;
Retrospective Studies
;
Middle Aged
;
Adult
;
Open Fracture Reduction/methods*
;
Treatment Outcome
;
Range of Motion, Articular
;
Fracture Healing
;
Operative Time
;
Length of Stay
;
Blood Loss, Surgical
;
Aged
;
Tibial Plateau Fractures
5.Short-term effectiveness of minimally invasive treatment for posterolateral depressed tibial plateau fractures assisted by robots and arthroscopy.
Zhongyao CHEN ; Xing DU ; Gang LUO ; Dagang TANG ; Xinyi WANG ; Yiyang LI ; Kangwen SUN ; Yi DUAN ; Wei SHUI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(7):801-806
OBJECTIVE:
To investigate short-term effectiveness of robot-assisted fracture reduction and fixation combined with arthroscopic exploration for posterolateral depressed tibial plateau fractures.
METHODS:
Between January 2022 and January 2024, 8 patients with posterolateral depressed tibial plateau fractures (Schatzker type Ⅲ) were treated using robot-assisted fracture reduction and fixation combined with arthroscopic exploration, with simultaneous treatment of concomitant ligament or meniscus tears. There were 3 males and 5 females with an average age of 54.1 years (range, 42-68 years). Injury mechanisms included traffic accidents (3 cases) and falls (5 cases). The time from injury to operation ranged from 2 to 4 days (mean, 3.1 days). Operation time, intraoperative blood loss, hospital stay duration, visual analogue scale (VAS) score for pain, and complications were recorded. Fracture healing and knee Rasmussen scores were assessed radiographically, while knee function was evaluated using range of motion and Hospital for Special Surgery (HSS) scores.
RESULTS:
All operations were successfully completed. The operation time was 108-129 minutes (mean, 120.1 minutes). The intraoperative blood loss was 10-100 mL (mean, 41.3 mL). The hospital stay duration was 4-7 days (mean, 5.6 days). All incisions healed by first intention without complication such as peroneal nerve injury, vascular damage, or infection. All patients were followed up 32-48 weeks (mean, 40 weeks). Radiographic follow-up confirmed that the knee Rasmussen scores rated as excellent in 8 patients and all fractures healed with the healing time of 12-16 weeks (mean, 13.5 weeks). The VAS score for pain was 2-4 (mean, 2.8) at discharge and improved to 0 at 1 month after operation. The knee range of motion was 80°-110° (mean, 96.1°) at discharge and increased to 135°-140° (mean, 137.9°) at 1 month after operation. At 3 months after operation, the HSS score was 91-94 (mean, 92.8), all graded as excellent. No severe complication, including implant failure, occurred during follow-up.
CONCLUSION
For posterolateral depressed tibial plateau fractures, the minimally invasive approach combining robot-assisted fracture reduction and fixation with arthroscopic exploration demonstrates multiple advantages, including shorter operation time, reduced intraoperative blood loss, excellent wound healing, fewer complications, and rapid recovery of knee function. This technique achieves satisfactory short-term effectiveness, while its long-term effectiveness requires further evaluation.
Humans
;
Male
;
Tibial Fractures/surgery*
;
Female
;
Middle Aged
;
Adult
;
Arthroscopy/methods*
;
Minimally Invasive Surgical Procedures/methods*
;
Fracture Fixation, Internal/methods*
;
Aged
;
Treatment Outcome
;
Robotic Surgical Procedures/methods*
;
Operative Time
;
Range of Motion, Articular
;
Fracture Healing
;
Length of Stay
;
Tibial Plateau Fractures
6.Effect of different bone grafting methods and internal fixation on mechanical stability of Schatzker type Ⅱ tibial plateau fracture.
Zhongzheng WANG ; Yuchuan WANG ; Siyu TIAN ; Zitao WANG ; Ruipeng ZHANG ; Xiaodong LIAN ; Zhanle ZHENG ; Yingze ZHANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(7):807-813
OBJECTIVE:
To investigate the biomechanical characteristics of Schatzker type Ⅱ tibial plateau fracture fixed by different bone grafting methods and internal fixations.
METHODS:
Twenty-four embalmed specimens of adult knee joint were selected to make Schatzker type Ⅱ tibial plateau fracture models, which were randomly divided into 8 groups (groups A1-D1 and groups A2-D2, n=3). After all the fracture models were restored, non-structural iliac crest bone grafts were implanted in group A1-D1, and structural iliac crest bone grafts in groups A2-D2. Following bone grafting, group A was fixed with a lateral golf locking plate, group B was fixed with lateral golf locking plate combined compression bolt, group C was fixed with lateral tibial "L"-shaped locking plate, and group D was fixed with lateral tibial "L"-shaped locking plate combined compression bolt. Compression and cyclic loading tests were performed on a biomechanical testing machine. A distal femur specimen or a 4-cm-diameter homemade bone cement ball were used as a pressure application mould for each group of models. The specimens were loaded with local compression at a rate of 10 N/s and the mechanical loads were recorded when the vertical displacement of the split bone block reached 2 mm. Then, compressive and cyclic loading tests were conducted on the fixed models of each group. The specimens were compression loaded to 100, 400, 700, and 1 000 N at a speed of 10 N/s to record the vertical displacement of the split bone block. The specimens were also subjected to cyclic loading at 5 Hz and 10 N/s within the ranges 100-300, 100-500, 100-700, and 100-1 000 N to record the vertical displacement of the split bone block at the end of the entire cyclic loading test. The specimens were subjected to cyclic loading tests and the vertical displacement of the split bone block was recorded at the end of the test.
RESULTS:
When the vertical displacement of the collapsed bone block reached 2 mm, the mechanical load of groups A2-D2 was significantly greater than that of groups A1-D1 ( P<0.05). The mechanical load of groups B and D was significantly greater than that of group A under the two bone grafting methods ( P<0.05); the local mechanical load of group D was significantly greater than that of groups B and C under the structural iliac crest bone grafts ( P<0.05). There was no significant difference ( P>0.05) in the vertical displacement of the split bone blocks between the two bone graft methods when the compressive load was 100, 400, 700 N and the cyclic load was 100-300, 100-500, 100-700 N in groups A-D. However, the vertical displacement of bone block in groups A1-D1 was significantly greater than that in groups A2-D2 ( P<0.05) when the compressive loading was 1 000 N and the cyclic load was 100-1 000 N. The vertical displacement of bone block in group B was significantly smaller than that in group A, and that in group D was significantly smaller than that in group C under the same way of bone graft ( P<0.05).
CONCLUSION
Compared with non-structural iliac crest bone grafts implantation, structural iliac crest bone grafts is more effective in preventing secondary collapse of Schatzker type Ⅱ tibial plateau fracture, and locking plate combined with compression bolt fixation can provide better articular surface support and resistance to axial compression, and the lateral tibial "L"-shaped locking plate can better highlight its advantages of "raft" fixation and show better mechanical stability.
Humans
;
Bone Transplantation/methods*
;
Tibial Fractures/physiopathology*
;
Fracture Fixation, Internal/instrumentation*
;
Biomechanical Phenomena
;
Bone Plates
;
Ilium/transplantation*
;
Adult
;
Tibia/surgery*
;
Bone Cements
;
Knee Joint/surgery*
;
Male
;
Tibial Plateau Fractures
7.Guiding significance of intra-articular sagittal reduction in the treatment of tibial plateau fractures.
Jia-Fan ZHANG ; An-Hua LONG ; Da-Cheng HAN ; Zi-Chao JIA ; Ya-Kui ZHANG
China Journal of Orthopaedics and Traumatology 2025;38(1):100-104
Tibial plateau fracture is a fracture involving the proximal articular surface of the tibia, and its injury mechanism is complex, the fracture morphology is different, and it is often accompanied by different degrees of soft tissue injury, which is difficult to diagnose and treat. In recent years, the research hotspot has focused on solving the reduction and fixation of the posterior lateral column of the tibial plateau, because it has been clinically found that the residual sagittal plane after tibial plateau fracture is insufficient reduction or loss of reduction leads to knee joint dysfunction. The posterior inclination angle of the tibial plateau is an important parameter to describe the sagittal alignment of the tibia. In the natural state, the posterior tibial slope(PTS) is altered to involve the soft tissues around the knee joint such as anterior cruciate ligament(ACL) and posterior cruciate ligament(PCL), which affects the stability of the knee joint. In total knee arthroplasty(TKA), choosing the appropriate PTS can effectively increase the prosthesis survival rate, improve the flexion and extension knee efficacy, which is beneficial to knee joint stability. In the field of orthopedic trauma, correction of sagittal deformity is equally important, following the principle of "reverse mechanism of injury". Quantitative evaluation of postoperative sagittal realignment of tibial plateau fractures and investigation of the effect of sagittal realignment on long-term outcomes and complications are still poorly understood and require further clinical and biomechanical studies.
Humans
;
Tibial Fractures/physiopathology*
;
Fracture Fixation, Internal/methods*
;
Tibial Plateau Fractures
8.Comparison of efficacy of anterolateral tibial plateau fracture line and anterior tibial fenestration for the treatment of anterolateral tibial plateau column fracture combined with posterolateral column collapse.
Cheng-Fei MENG ; Guan-Qing WANG ; Cheng LUO ; Xiu-Hua LIU ; Ze-Xi LING
China Journal of Orthopaedics and Traumatology 2025;38(3):265-272
OBJECTIVE:
To compare clinical effect of anterior tibial plateau fracture line and anterior tibial fenestration reduction in treating anterolateral tibial plateau column fracture combined with posterior lateral column collapse.
METHODS:
Fifty-two patients with Schatzker typeⅡ tibial plateau anterolateral column fracture combined with posterolateral column collapse admitted from January 2016 to December 2021 were retrospectively analyzed and divided into two groups according to fracture reduction methods. There were 27 patients in fracture line group, including 19 males and 8 females, aged from 26 to 62 years old with an average of (43.2±11.4) years old;the time from injury to operation ranged from 4 to 8 days with an average of (5.8±1.5) days;treated with reduction and internal fixation via fracture line of lateral platform front. There were 25 patients in fenestrate group, including 13 males and 12 females, aged from 22 to 69 years old with an average of (40.8±11.1) years old;the time from injury to operation ranged from 4 to 8 days with an average of (6.0±1.4) days;treated with tibial fenestration reduction and internal fixation. The amount of bone graft, operation time, fracture healing time and complications were compared between two groups. Posterior slope angle (PSA) and posterior slope angle of the lateral tibial plateau was compared before surgery, 2 days and 6 months after surgery. The knee function was evaluated by Hospital for Speical Surgery (HSS) at 2 days and 6 months after surgery, respectively. Fracture reduction was evaluated by Rasmussen anatomic score of knee joint.
RESULTS:
Both of group were followed up from 12 to 24 months (16.0±3.4) months. No redisplacement of fracture, internal and external inversion deformity of knee joint, or instability of knee joint were found between two groups during follow-up. In fracture line group, 1 patient occurred wound fat liquefaction and 2 patients occurred lower limb intermuscular venous thrombosis occurred. In fenestration group, 1 patient occurred joint stiffness, 1 patient occurred lower limb intermuscular venous thrombosis, and 1 patient occurred superficial wound infection;there were no significant difference in complications between two groups (P>0.05). Bone graft volume, operative time and fracture healing time in fracture line group were (3.6±2.3) cm3, (123.4±18.2) min and (13.8±1.8) weeks, while in feneplast group were (4.8±1.8) cm3, (135.5±22.5) min and (15.2±2.0) weeks, respectively;the difference between two groups was statistically significant (P<0.05). The collapse depth of lateral platform articular surface at 2 days and 6 months after surgery were (0.8±0.1) and (0.9±0.1) mm in fracture line group, which were lower than those in fenestration group (0.9±0.1) and (1.1±0.1) mm, respectively (P<0.05). After 2 days and 6 months, , PSA in fracture line group were (9.4±1.5) ° and (10.1±1.9) °, respectively, which were lower than those in fenestration group (10.5±1.5) ° and (11.3±1.9) ° (P<0.05). Rasmussen anatomical scores in fracture line group at 2 days and 6 months were 16(16, 18) and 16(14, 16) points, respectively, which were better than those in fenestrated group (16, 16) and 14(14, 16) points (P< 0.05). The collapse depth, PSA and Rasmussen anatomical score between two groups were better than those before surgery (P<0.05). There was no significant difference in HSS score between two groups at 2 days after surgery (P>0.05). At six months after surgery, HSS score in fracture line group (86.7±3.6) was higher than that in fenestration group (84.1±3.91) (P<0.05). HSS score at 6 months after surgery was better than that at 2 days after surgery (P<0.05).
CONCLUSION
Both anterior tibial plateau fracture line and anterior tibial fenestration could be used to treat anterolateral tibial plateau column fracture with posterior lateral column collapse. Compared with fenestration group, transfracture line group had advantages of less intraoperative bone grafting, shorter operative time, shorter fracture healing time, better articular surface reduction effect and better knee functional recovery.
Humans
;
Male
;
Female
;
Middle Aged
;
Tibial Fractures/physiopathology*
;
Adult
;
Fracture Fixation, Internal/methods*
;
Aged
;
Retrospective Studies
;
Tibia/injuries*
;
Tibial Plateau Fractures
9.Research progress on biomechanics for internal fixation in tibial plateau fracture.
Jialun LIU ; Yingze ZHANG ; Zhanle ZHENG
Chinese Journal of Reparative and Reconstructive Surgery 2024;38(1):113-118
OBJECTIVE:
To review the biomechanical research progress of internal fixation of tibial plateau fracture in recent years and provide a reference for the selection of internal fixation in clinic.
METHODS:
The literature related to the biomechanical research of internal fixation of tibial plateau fracture at home and abroad was extensively reviewed, and the biomechanical characteristics of the internal fixation mode and position as well as the biomechanical characteristics of different internal fixators, such as screws, plates, and intramedullary nails were summarized and analyzed.
RESULTS:
Tibial plateau fracture is one of the common types of knee fractures. The conventional surgical treatment for tibial plateau fracture is open or closed reduction and internal fixation, which requires anatomical reduction and strong fixation. Anatomical reduction can restore the normal shape of the knee joint; strong fixation provides good biomechanical stability, so that the patient can have early functional exercise, restore knee mobility as early as possible, and avoid knee stiffness. Different internal fixators have their own biomechanical strengths and characteristics. The screw fixation has the advantage of being minimally invasive, but the fixation strength is limited, and it is mostly applied to Schatzker typeⅠfracture. For Schatzker Ⅰ-Ⅳ fracture, unilateral plate fixation can be used; for Schatzker Ⅴand Ⅵ fracture, bilateral plates fixation can be used to provide stronger fixation strength and avoid the stress concentration. The intramedullary nails fixation has the advantages of less trauma and less influence on the blood flow of the fracture end, but the fixation strength of the medial and lateral plateau is limited; so it is more suitable for tibial plateau fracture that involves only the metaphysis. Choosing the most appropriate internal fixation according to the patient's condition is still a major difficulty in the surgical treatment of tibial plateau fractures.
CONCLUSION
Each internal fixator has good fixation effect on tibial plateau fracture within the applicable range, and it is an important research direction to improve and innovate the existing internal fixator from various aspects, such as manufacturing process, material, and morphology.
Humans
;
Biomechanical Phenomena
;
Bone Plates
;
Fracture Fixation, Internal
;
Fracture Fixation, Intramedullary
;
Tibial Fractures/surgery*
;
Tibial Plateau Fractures
10.Electric scooter injuries: Incidence and injury patterns at a level I trauma center.
Nina D FISHER ; Ekenedilichukwu NWAKOBY ; Hunter HERNANDEZ ; Toni M MCLAURIN
Chinese Journal of Traumatology 2023;26(6):334-338
PURPOSE:
Electric scooters (e-scooters) have become an increasingly popular mode of public transportation in recent years. As the incidence of related injuries rises, it is important to understand specific fracture patterns unique to e-scooters and electric bikes (e-bikes) to help guide management. The purpose of this study was to review the prevalence and describe specific fracture patterns of e-scooter and e-bike related injuries at the busiest level 1 trauma center in the borough of Manhattan.
METHODS:
Chart review to determine mechanism of injury was performed on all patients for whom an orthopedic consult was requested from 1/1/2021 to 12/31/2021. All patients whose injuries were sustained due to an e-scooter or e-bike were further reviewed for demographics, injury characteristics including fracture pattern, and definitive injury management. Any patients who had an orthopedic consult placed for a reason other than an acute injury were excluded. Descriptive statistics are reported as frequency (percentage) for categorical variables and means for continuous variables.
RESULTS:
Of the 1815 orthopedic consults requested, 1357 (74.8%) were for acute injury management. Of those with acute injuries, 119 (8.8%) sustained 136 e-scooter or e-bike related injuries. There were 92 (77.3%) males at an average age of (33.8 ± 15.7) years. Approximately one-fifth of all patients presented in June 2021 (26, 21.8%). There was a 9.2% rate of open fractures. The 136 injuries were evenly split between the upper and lower extremities, with 57 (47.9%) upper extremity, 57 (47.9%) lower extremity injuries, and 5 (4.2%) concomitant upper and lower extremity injuries. The most common fracture patterns were ankle fractures (16, 11.7%), followed by tibial shaft (14, 10.2%), tibial plateau (13, 9.5%), and radial head fractures (11, 8.0%). There was a 33.3% incidence of associated posterior malleolar fractures in the spiral tibial shaft fractures, 31.0% of posterior malleolar involvement and 18.8% of isolated vertical medial malleolar fractures in the ankle fractures, and 61.5% of posterior comminution in the tibial plateau fractures.
CONCLUSION
E-scooter and e-bike related injuries have a high incidence of tibial shaft fractures, ankle fractures, tibial plateau fractures, and radial head fractures. There should be a high index of suspicion for posterior and medial involvement in lower extremity fractures sustained due to e-scooter or e-bikes. Identifying specific fracture patterns seen in e-scooter and e-bike related mechanisms will help guide management of these injuries.
Male
;
Humans
;
Adolescent
;
Young Adult
;
Adult
;
Middle Aged
;
Female
;
Ankle Fractures
;
Trauma Centers
;
Incidence
;
Radial Head and Neck Fractures
;
Tibial Plateau Fractures
;
Retrospective Studies
;
Tibial Fractures/complications*
;
Radius Fractures

Result Analysis
Print
Save
E-mail