1.Application of 3D printing accurate osteotomy guide combined with the revision of anterior cruciate ligament with abnormally increased posterior slope of tibial plateau
Zhiheng WEI ; Tianmin GUAN ; Qing LIU ; Jue GONG ; Xianxiang XIANG
Chinese Journal of Tissue Engineering Research 2025;29(33):7130-7136
BACKGROUND:For patients with anterior cruciate ligament re-rupture after reconstruction with abnormally increased posterior slope of the tibial plateau,anterior cruciate ligament reconstruction combined with anterior closing-wedge high tibial osteotomy was performed.However,there is a lack of precise tools for osteotomy.OBJECTIVE:To investigate the effectiveness of three-dimensional(3D)printed accurate osteotomy template in anterior cruciate ligament revision for patients with excessive posterior slope.METHODS:The medical records of 30 patients who underwent anterior cruciate ligament revision combined with anterior closing-wedge high tibial osteotomy were retrospectively collected and divided into two groups according to the operation method.The trial group(n=15)was assisted by 3D printing osteotomy guide plate.The control group(n=15)was conventional surgery.The osteotomy time,fluoroscopy times,intraoperative and 24 hours postoperative blood loss,preoperative and 3 months postoperative tibiofemoral anatomical angle,medial proximal tibial anatomical angle,posterior slope,the difference between planned posterior slope correction angle and actual correction angle,and KT-2000 side-to-side difference before operation,3 and 24 months after operation were compared between the two groups.Lachman test and Pivot shift test were performed before operation,immediately after operation,and 24 months after operation.International Knee Documentation Committee score and Lysholm score were performed before operation,3 and 24 months after operation.RESULTS AND CONCLUSION:(1)The osteotomy time,fluoroscopy times,and blood loss during operation and 24 hours after operation in the trial group were significantly less than those in the control group(P<0.05).(2)The posterior slope of the two groups decreased significantly after operation.There was no significant change in tibiofemoral anatomical angle and medial proximal tibial anatomical angle after operation.The difference between preoperative planned and postoperative actual posterior slope degree in the trial group(0.64±0.41)° was smaller than that in the control group(2.18±0.54)°,and the difference was statistically significant(P<0.001).(3)The KT-2000 side-to-side difference was significantly reduced in both groups after surgery(P<0.05).At 3 and 24 months after operation,there was no significant difference in KT-2000 side-to-side difference between the two groups(P>0.05).The Lachman test and Pivot shift test of the two groups were negative immediately after operation,3 and 24 months after operation.(4)The International Knee Documentation Committee and Lysholm scores of the two groups increased significantly after surgery(P<0.05).At 3 months after operation,the International Knee Documentation Committee score and Lysholm score of the trial group were significantly higher than those of the control group(P<0.05).At 24 months after operation,there was no significant difference in International Knee Documentation Committee score and Lysholm score between the two groups(P>0.05).(5)In conclusion,with the assistance of 3D printing accurate osteotomy guide plate,anterior cruciate ligament reconstruction combined with anterior closing-wedge high tibial osteotomy is easier to operate,with shorter operation time,fewer fluoroscopy times,less intraoperative and postoperative blood loss,and faster recovery of knee joint function after operation,which has high clinical application value.
2.Application of 3D printing accurate osteotomy guide combined with the revision of anterior cruciate ligament with abnormally increased posterior slope of tibial plateau
Zhiheng WEI ; Tianmin GUAN ; Qing LIU ; Jue GONG ; Xianxiang XIANG
Chinese Journal of Tissue Engineering Research 2025;29(33):7130-7136
BACKGROUND:For patients with anterior cruciate ligament re-rupture after reconstruction with abnormally increased posterior slope of the tibial plateau,anterior cruciate ligament reconstruction combined with anterior closing-wedge high tibial osteotomy was performed.However,there is a lack of precise tools for osteotomy.OBJECTIVE:To investigate the effectiveness of three-dimensional(3D)printed accurate osteotomy template in anterior cruciate ligament revision for patients with excessive posterior slope.METHODS:The medical records of 30 patients who underwent anterior cruciate ligament revision combined with anterior closing-wedge high tibial osteotomy were retrospectively collected and divided into two groups according to the operation method.The trial group(n=15)was assisted by 3D printing osteotomy guide plate.The control group(n=15)was conventional surgery.The osteotomy time,fluoroscopy times,intraoperative and 24 hours postoperative blood loss,preoperative and 3 months postoperative tibiofemoral anatomical angle,medial proximal tibial anatomical angle,posterior slope,the difference between planned posterior slope correction angle and actual correction angle,and KT-2000 side-to-side difference before operation,3 and 24 months after operation were compared between the two groups.Lachman test and Pivot shift test were performed before operation,immediately after operation,and 24 months after operation.International Knee Documentation Committee score and Lysholm score were performed before operation,3 and 24 months after operation.RESULTS AND CONCLUSION:(1)The osteotomy time,fluoroscopy times,and blood loss during operation and 24 hours after operation in the trial group were significantly less than those in the control group(P<0.05).(2)The posterior slope of the two groups decreased significantly after operation.There was no significant change in tibiofemoral anatomical angle and medial proximal tibial anatomical angle after operation.The difference between preoperative planned and postoperative actual posterior slope degree in the trial group(0.64±0.41)° was smaller than that in the control group(2.18±0.54)°,and the difference was statistically significant(P<0.001).(3)The KT-2000 side-to-side difference was significantly reduced in both groups after surgery(P<0.05).At 3 and 24 months after operation,there was no significant difference in KT-2000 side-to-side difference between the two groups(P>0.05).The Lachman test and Pivot shift test of the two groups were negative immediately after operation,3 and 24 months after operation.(4)The International Knee Documentation Committee and Lysholm scores of the two groups increased significantly after surgery(P<0.05).At 3 months after operation,the International Knee Documentation Committee score and Lysholm score of the trial group were significantly higher than those of the control group(P<0.05).At 24 months after operation,there was no significant difference in International Knee Documentation Committee score and Lysholm score between the two groups(P>0.05).(5)In conclusion,with the assistance of 3D printing accurate osteotomy guide plate,anterior cruciate ligament reconstruction combined with anterior closing-wedge high tibial osteotomy is easier to operate,with shorter operation time,fewer fluoroscopy times,less intraoperative and postoperative blood loss,and faster recovery of knee joint function after operation,which has high clinical application value.
3.Application of mixed reality technology in vertebroplasty
Yong JIANG ; Tianmin GUAN ; Yuan CI ; Ye ZHU ; Peng ZHAO ; Jiafa ZHENG ; Tao YANG ; Guangyu ZHANG
Chinese Journal of Tissue Engineering Research 2024;28(30):4812-4816
BACKGROUND:How to improve the accuracy of puncture,reduce surgical damage,and improve surgical efficiency during vertebroplasty is currently one of the focuses of exploration and improvement in vertebroplasty techniques. OBJECTIVE:To explore the clinical significance of application of mixed reality technology in percutaneous vertebroplasty for spinal fractures. METHODS:Two patients with osteoporotic vertebral compression fracture in Dalian Second People's Hospital in June 2023 were selected.Before operation,128-row CT scanning of the lumbar spine was performed and the original data of digital imaging and communications in medicine(DICOM)were obtained.Visual Volume software was used to build the three-dimensional network model of vertebral compression fracture.Holographic imaging glasses were used to accurately map 3D network model images to the real world,assist the surgeon in completing preoperative simulation,explaining preoperative conditions and treatment plans,and guiding puncture and bone cement injection during surgery. RESULTS AND CONCLUSION:(1)Precise puncture was achieved with the assistance of a mixed reality technology.Postoperative imaging examination showed good bone cement filling and no obvious leakage.The postoperative symptoms of the patient were alleviated well,and they were able to move to the ground on the same day after surgery.(2)It is concluded that a mixed reality technology is helpful for preoperative surgical design and communication efficiency with patients and their families.Assisting with precise puncture during surgery,shortening surgical time,and reducing side injuries is a new and effective clinical diagnosis and treatment model,which has development potential in minimally invasive,precise,and personalized treatment of spinal surgery.
4.Bibliometric and visual analysis of domestic and foreign scoliosis orthoses
Yanli YUAN ; Yuejun PAN ; Tianmin GUAN ; Kai CHENG ; Xiangheng WANG
Chinese Journal of Tissue Engineering Research 2024;33(33):5396-5402
BACKGROUND:Scoliosis mainly refers to sequence abnormalities in the coronal,sagittal,and axial positions of the spine,with a Cobb angle of≥10°.The patients may experience symptoms such as unequal shoulder height and back asymmetry.Severe cases may affect the patient's cardiopulmonary function,thereby affecting their daily life.Conservative treatment can control the progression of scoliosis and avoid later surgery.Scoliosis orthosis is currently a commonly used and effective treatment measure in conservative treatment. OBJECTIVE:To summarize and analyze the current research status,hotspots,and trends of scoliosis orthoses both domestically and internationally,providing reference for related research. METHODS:Using bibliometrics and visual analysis as tools,and using a comparison between China and foreign countries as a method,this paper analyzes the literature on scoliosis orthosis journals in the past decade.Based on bibliometrics,the current status of research on scoliosis orthoses is determined.Citespace software is used to analyze key words and identify the current hotspots and future trends in scoliosis orthosis research. RESULTS AND CONCLUSION:(1)At present,the number of literature on scoliosis orthoses is still on a fluctuating upward trend.China and the United States are the main countries for research,with a literature share of over 40%.However,the average citation rate of foreign language literature by Chinese scholars is relatively low.(2)The basic fields of domestic research are mainly surgery and pediatrics,while orthotics and clinical neurology are mainly studied abroad.Among them,there is also a certain number of documents in domestic Chinese medicine,indicating that China is also engaged in the combination of Chinese and Western treatment of scoliosis.The National Natural Science Foundation of China has the highest proportion in the aspect of Chinese and foreign literature,reflecting the importance of the fund attaches to the research of scoliosis orthosis.(3)The authors with the highest number of publications are Qiu Yong and Negrini Stefano,and the most published institutions are the Spinal Surgery Department of Gulou Hospital affiliated to Nanjing University Medical College and UDICE-French Research University.Domestic and foreign authors and institutions have certain communications about this,but not closely,which requires relevant institutions and scholars to further explore and study.(4)From the research hotspots and future trends,the main treatment type is adolescent idiopathic scoliosis,while the production method of the short-column side bending orthosis is three-dimensinoal printing,and the main treatment index is convex progression.The ultimate purpose of treatment is to improve the quality of life of the patients.
5.Customized Design and Three-Dimensional Molding of Bracketless Orthodontic Appliance
Tianmin GUAN ; Xin LI ; Qiang MA ; Yun ZHAI
Journal of Medical Biomechanics 2024;39(1):164-171
Objective A finite element simulation analysis of a bracketless orthodontic appliance was carried out to determine the correction amount under different working conditions.A design scheme for the bracketless orthodontic appliance was also formulated to create an orthodontic appliance formed by the fused deposition process with a personalized orthodontic effect.Methods Combined with the computed tomography data of the patient,a tooth model was reversely reconstructed.The correction amount of the tooth under tilting,twisting,and translation working conditions was established using the finite element method.Materials with different elastic moduli were chosen to make three-dimensional(3D)shaped bracketless orthodonitc appliance,and the orthodontic force was measured.Results Different correction amounts could be designed according to different working conditions so that the orthodontic appliance had a personalized treatment effect.The orthodontic force of the bracketless orthodontic appliance increased with elastic modulus and thickness.Under the given working conditions,the orthodontic force was minimal(90 mN)when the orthodontic material was at the minimum(90 mN).The orthodontic force reached its maximum value when the orthodontic material was at the maximum(61.66 N).Conclusions According to the patient's tooth condition and the size of the orthodontic force required for each step of correction in the whole correction process,the design should consider bracketless orthodontics with different elastic moduli and thicknesses to treat deformed teeth to realize the effect of staged orthodontic correction.
6.Correlation between lesion volume ratio and cognitive function in ischemic leukoaraiosis
Na SUN ; Jianfeng WANG ; Tianmin GUAN ; Aiqi WANG ; Xuemei WANG ; Lizhen ZHONG ; Xueying CHENG ; Hua ZHAO
Chinese Journal of Postgraduates of Medicine 2022;45(1):31-36
Objective:To investigate the relationship between the volume ratio of ischemic leukoaraiosis (LA) and cognitive level and arterial perfusion.Methods:Fifty-four patients, who was hospitalized in Dalian Central Hospital and diagnosed as LA clinically during the time of March to December in 2012, were selected to collect the information of the volume ratio of white matter disease, MoCa score and the average flow rate of carotid artery. The correlation between the volume ratio of white matter disease and MoCa score, cognitive impairment and the average flow rate of carotid artery were analyzed.Results:The volume ratio of LA lesions was negatively correlated with MOCA score ( r = -0.59, P<0.01); the volume ratio of LA lesions was negatively correlated with the mean flow rate of internal carotid artery ( r = -0.37, P<0.01). Quantity order of the area under receiver operating characteristic (ROC) curve of MoCA cognitive subgroup was as following: delayed memory (1.000)> visual space/executive function (0.970) = abstract force (0.970)> language ability (0.960)> attention (0.888). Conclusions:The larger the volume ratio of leukopathy in LA patients, the more serious the cognitive impairment, especially the cognitive impairment of impairment of memory delay, visual space/executive function, abstract ability and language ability.

Result Analysis
Print
Save
E-mail