1.Status and implications of pharmacist competency assessment tools
Yu TIAN ; Bei DING ; Chenyang ZHANG ; Yi ZHAO ; Jiaying WANG
China Pharmacy 2026;37(5):553-558
OBJECTIVE To systematically review the status on pharmacist competency assessment tools both domestically and internationally, providing a theoretical basis for constructing scientific and applicable pharmacist competency assessment tools in China. METHODS Through literature review and comparative analysis, 15 representative domestic and international pharmacist competency assessment tools were systematically summarized, and their theoretical foundations, core dimensions, methodological characteristics and practical applications were compared and implications were given. RESULTS &CONCLUSIONS International research has established relatively mature evaluation systems. Represented by those developed from the United Kingdom, the United States, and the International Pharmaceutical Federation, these assessment tools demonstrate scientific structure, wide application, and dynamic and international applicability. While domestic research has progressed in sub-specialties such as clinical pharmacists, licensed pharmacists and pediatric pharmacists, it still faces challenges including insufficient standardization, inadequate validation, delayed updates, and limitations in practical application. The reasons for the disparities in assessment tools between China and other countries include differences in pharmaceutical care models, varying pharmacist training systems, cultural and social background factors, as well as differences in industry management and international influence. Based on this, the author suggests promoting the development and research of assessment tools for pharmacist job competency in China from four aspects: mechanism construction, system refinement, standardization development, and practical implementation.
2.Analysis of serological and molecular genetic characteristics of a Chinese pedigree with a B(A)06 subtype.
Dongdong TIAN ; Ding ZHAO ; Wei LI ; Zhihao LI ; Jiali YANG ; Yongfang ZHANG ; Liuchuang ZHENG
Chinese Journal of Medical Genetics 2026;43(3):220-227
OBJECTIVE:
To explore the serological and molecular genetic characteristics of a family with subtype B(A)06.
METHODS:
A neonatal hyperbilirubinemia patient who was treated at Henan Children's Hospital on June 15, 2023 due to "yellowing of the skin and gradual aggravation", and was found to have inconsistent ABO forward and reverse typing through blood type testing, was selected as the research subject. Six milliliters of peripheral blood were collected from the newborn and her family members (grandfather, grandmother, father, mother and aunt) respectively. ABO blood group identification was performed by the blood group serological method. Human genomic DNA was extracted using the nucleic acid extraction or purification reagent BT-01. ABO gene exons 2 to 7 were amplified by PCR. The PCR-specific products that were successfully amplified were sequenced by Sanger method. Taking ABO*A1.01 as the reference sequence, the ABO gene sequences of the newborn and her family members were analyzed to determine the ABO genotype. The procedures followed in this study were approved by the Ethics Committee of Henan Children's Hospital (Ethics No.: 2022-K-L036).
RESULTS:
The serological results of ABO blood group showed that the newborn, her grandfather, father and aunt were all incompatible with the forward and reverse typing. The blood group phenotype of the newborn was AwB or B(A), the blood group phenotype of the grandfather was A2B or B(A), the blood group phenotype of the father and aunt were A2B, and the blood group phenotype of the grandmother and mother were both O. The screening test results of hemolytic disease of the newborn showed that the free test detected IgG anti-A1 antibody, while the elution test, direct antiglobulin test and antibody screening results were all negative. The Sanger sequencing results showed that the newborn had variations of c.261delG, c.297A>G, c.526C>G, c.657C>T, c.703G>A, c.796C>A and c.930G>A. Her grandfather had variations of c.297A>G, C.526C>G, c.657C>T, c.703G>A, c.796C>A, c.803G>C and c.930G>A. Her grandmother had variations of c.106G>T, c.188G>A, c.189C>T, c.220C>T, c.261delG, c.297A>G, c.646T>A, c.681G>A, c.771C>T and c.829G>A. Her father and aunt had variations of c.106G>T, c.188G>A, c.189C>T, c.220C>T, c.261delG, c.297A>G, c.526C>G, c.646T>A, c.657C>T, c.681G>A, c.703G>A, c.771C>T, c.796C>A, c.829G>A and c.930G>A. Her mother had variations of c.106G>T, c.188G>A, c.189C>T, c.220C>T, c.261delG, c.297A>G, c.646T>A, c.681G>A, c.771C>T, and c.829G>A.The genotype of the newborn was ABO*BA.06/ABO*O.01.01, her grandfather was ABO*BA.06/ABO*B.01, her grandmother was ABO*O.01.02/ABO*O.01.02, her father and aunt were ABO*BA.06/ABO*O.01.02, and her mother was ABO*O.01.01/ABO*O.01.02. The ABO*BA.06 allele of the newborn, grandfather, father and aunt was caused by the c.803C>G variation in exon 7 based on the ABO*B.01 allele. The ABO*BA.06 allele can be stably inherited in this family.
CONCLUSION
The blood type of neonatal patients with B(A)06 subtype can be accurately determined by gene sequencing technology. If the forward typing is ≤ 3+ agglutination intensity in newborn ABO blood group identification, the reason should be carefully analyzed, and the molecular biology technology and family gene sequencing results should be used to jointly determine if necessary.
Humans
;
ABO Blood-Group System/genetics*
;
Female
;
Pedigree
;
Male
;
Infant, Newborn
;
Asian People/genetics*
;
Genotype
;
China
;
Blood Grouping and Crossmatching
;
Hyperbilirubinemia, Neonatal/blood*
;
East Asian People
3.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
4.Differences in scapular kinematics between healthy individuals and rotator cuff tear patients based on biplane X-ray
Zicheng GUO ; Jingyuan MENG ; Jiechao ZHANG ; Li DING ; Xiaoye TANG ; Lichao TIAN ; Yilin WANG ; Yong HE
Chinese Journal of Tissue Engineering Research 2026;30(3):652-660
BACKGROUND:Due to the complex movement of the scapula,which is a six-degree-of-freedom activity in three-dimensional space,it is difficult to measure it accurately using traditional methods.The image and model matching technology based on dual-plane X-ray is a three-dimensional measurement method that has gradually developed and matured in recent years.Two high-speed cameras are used to project and shoot from orthogonal directions.Compared with a single perspective,this method has advantages in observation range and reduction of out-of-plane errors,and is suitable for the study of scapula kinematics.OBJECTIVE:X-ray biplane and image-model registration technology were used to explore the differences in scapular kinematics between normal individuals and patients with rotator cuff tears,providing a basis for the treatment and rehabilitation of rotator cuff tear patients.METHODS:From April 2023 to January 2024,10 patients with normal shoulders and 10 patients with rotator cuff tears who met the inclusion criteria were enrolled from Guanghua Hospital Affiliated to Shanghai University of Traditional Chinese Medicine.The subjects underwent a shoulder CT scan to create a 3D model and a local scapular coordinate system.X-ray biplane images were taken during shoulder abduction with two C-arm machines.The 2D and 3D images were registered to compare scapular kinematic differences between the two groups at 0°,15°,30°,45°,60°,75°,and 90° of abduction,including scapular rotation angle and displacement distance.RESULTS AND CONCLUSION:(1)During shoulder abduction,the scapula of both groups showed upward rotation,but the upward rotation of the rotator cuff tear group was greater than that of the control group,and the difference was significant when the abduction was 30°-90°(P<0.01).At the same time,the scapula internal rotation of both groups gradually increased,but the rotator cuff tear group was significantly greater than the control group when the abduction was 45°-90°(P<0.01).In addition,the anteroposterior tilt of the scapula of the two groups was significantly different when the abduction was 15°-90°(P<0.01).The scapula posterior tilt of the control group gradually increased during abduction,while the scapula of the rotator cuff tear group tilted forward except for a slight posterior tilt at 15°-30° abduction.(2)In terms of displacement,the upward displacement of the rotator cuff tear group was less than that of the control group during abduction,and the difference was significant at 15°-90°(P<0.05),but there was no significant difference in lateral and anterior-posterior displacement between the two groups(P>0.05).(3)Rotator cuff tear can cause scapular dyskinesis,characterized by increased upward rotation,internal rotation,and abnormal forward tilt during shoulder abduction.Identifying and addressing scapular dyskinesis is crucial for treating rotator cuff tear.
5.Differences in scapular kinematics between healthy individuals and rotator cuff tear patients based on biplane X-ray
Zicheng GUO ; Jingyuan MENG ; Jiechao ZHANG ; Li DING ; Xiaoye TANG ; Lichao TIAN ; Yilin WANG ; Yong HE
Chinese Journal of Tissue Engineering Research 2026;30(3):652-660
BACKGROUND:Due to the complex movement of the scapula,which is a six-degree-of-freedom activity in three-dimensional space,it is difficult to measure it accurately using traditional methods.The image and model matching technology based on dual-plane X-ray is a three-dimensional measurement method that has gradually developed and matured in recent years.Two high-speed cameras are used to project and shoot from orthogonal directions.Compared with a single perspective,this method has advantages in observation range and reduction of out-of-plane errors,and is suitable for the study of scapula kinematics.OBJECTIVE:X-ray biplane and image-model registration technology were used to explore the differences in scapular kinematics between normal individuals and patients with rotator cuff tears,providing a basis for the treatment and rehabilitation of rotator cuff tear patients.METHODS:From April 2023 to January 2024,10 patients with normal shoulders and 10 patients with rotator cuff tears who met the inclusion criteria were enrolled from Guanghua Hospital Affiliated to Shanghai University of Traditional Chinese Medicine.The subjects underwent a shoulder CT scan to create a 3D model and a local scapular coordinate system.X-ray biplane images were taken during shoulder abduction with two C-arm machines.The 2D and 3D images were registered to compare scapular kinematic differences between the two groups at 0°,15°,30°,45°,60°,75°,and 90° of abduction,including scapular rotation angle and displacement distance.RESULTS AND CONCLUSION:(1)During shoulder abduction,the scapula of both groups showed upward rotation,but the upward rotation of the rotator cuff tear group was greater than that of the control group,and the difference was significant when the abduction was 30°-90°(P<0.01).At the same time,the scapula internal rotation of both groups gradually increased,but the rotator cuff tear group was significantly greater than the control group when the abduction was 45°-90°(P<0.01).In addition,the anteroposterior tilt of the scapula of the two groups was significantly different when the abduction was 15°-90°(P<0.01).The scapula posterior tilt of the control group gradually increased during abduction,while the scapula of the rotator cuff tear group tilted forward except for a slight posterior tilt at 15°-30° abduction.(2)In terms of displacement,the upward displacement of the rotator cuff tear group was less than that of the control group during abduction,and the difference was significant at 15°-90°(P<0.05),but there was no significant difference in lateral and anterior-posterior displacement between the two groups(P>0.05).(3)Rotator cuff tear can cause scapular dyskinesis,characterized by increased upward rotation,internal rotation,and abnormal forward tilt during shoulder abduction.Identifying and addressing scapular dyskinesis is crucial for treating rotator cuff tear.
6.Effect of Heat-sensitive Moxibustion on Quality of Life and Immune Function in Non-Small Cell Lung Cancer Patients with Qi Deficiency and Phlegm Stasis Syndrome Undergoing Chemotherapy:A Randomized Controlled Trial
Wenhao ZHAN ; Qian DING ; Zhiwei DONG ; Ting LI ; Shumei FU ; Ning TIAN
Journal of Traditional Chinese Medicine 2026;67(12):1289-1296
ObjectiveTo observe the effect of heat-sensitive moxibustion on quality of life and immune function in non-small cell lung cancer (NSCLC) patients undergoing chemotherapy. MethodsSeventy NSCLC patients with qi deficiency and phlegm stasis syndrome were randomly divided into an intervention group and a control group, with 35 cases in each group. The control group received chemotherapy combined with routine symptomatic treatment, while the intervention group additionally received heat-sensitive moxibustion since the first day of chemotherapy. Acupoints included Dazhui (GV14), bilateral Feishu (BL13), Zhongwan (CV12), Qihai (CV6), and Guanyuan (CV4). The site exhibiting the strongest heat-sensitization response was selected for moxibustion. Treatment was administered for 45 minutes per session, three times weekly for three consecutive weeks, totaling nine sessions. Before and after treatment, quality of life was assessed using the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ-C30), and traditional Chinese medicine (TCM) syndrome scores were evaluated. Peripheral blood levels of natural killer (NK) cells and T-lymphocyte subsets including CD3+, CD4+, and CD8+, and CD4+/CD8+ ratio were measured. Levels of programmed cell death protein-1 (PD-1), including PD-1⁺CD4⁺ and PD-1⁺CD8⁺ cells, were also assessed. Liver and renal function were monitored before and after treatment, and adverse events were recorded. ResultsIn the intervention group, 1 participant withdrew and 1 was excluded, while in the control group, 2 participants withdrew. Ultimately, 33 participants in each group were included in the final analysis. The intervention group showed significant improvements in physical, role, emotional, cognitive, and social functioning, as well as global health status after treatment, while scores for fatigue, nausea and vomiting, dyspnea, appetite loss, diarrhea, and TCM syndrome scale were significantly decreased (P<0.05). Moreover, the intervention group demonstrated higher scores in physical functioning, role functioning, and global health status, as well as lower scores for fatigue, nausea and vomiting, dyspnea, appetite loss, diarrhea, and the TCM syndrome scale than the control group (P<0.05). After treatment, the levels of peripheral NK cells and PD-1⁺CD8⁺ T cells in the intervention group increased significantly; furthermore, the intervention group exhibited higher peripheral NK cell levels and lower PD-1⁺CD8⁺ T cell levels than the control group (P<0.05). No significant differences were found in liver or renal function between the two groups (P>0.05). In addition, no adverse events such as burns or moxibustion-induced syncope occurred during the study. ConclusionHeat-sensitive moxibustion as an adjunctive therapy may enhance immune function, alleviate clinical symptoms, and improve quality of life, while demonstrating a favorable safety profile in NSCLC patients with qi deficiency and phlegm stasis.
7.Genetic analysis of weak expression of ABO blood group antigens in neonates
Jiali YANG ; Ding ZHAO ; Wei LI ; Xiaopan ZHANG ; Zhihao LI ; Dongdong TIAN
Chinese Journal of Blood Transfusion 2025;38(1):85-90
[Objective] To perform genetic analysis on samples with weak agglutination and mixed agglutination of ABO blood group antigens in neonates, and to investigate the molecular biological characteristics of ABO subtypes in neonates. [Methods] Serological identification of ABO blood group was performed by tube method and microcolumn gel method. The ABO exons 2-7 were amplified by PCR, and the amplified products were sequenced by Sanger sequencing method to determine the genotype. [Results] Among the ABO blood group serological results of 14 neonates, 8 cases showed weakened A antigen, and 6 cases showed weakened B antigen. Seven samples were identified with ABO subtype alleles, with genotypes as A102/B101+c.538C>T, Aw26/B102, A205/O02, A205/B101(2 cases), Aw26/O02, B(A)06/O01, B101/O01(3 cases), A102/O01(2 cases), A102/B101 and B101/O02. Additionally, three other family members were also found to carry B(A)06 allele in a pedigree investigation. [Conclusion] For samples showing weakened antigens in ABO blood type identification of neonates, it is necessary to consider the possibility of ABO subtype in addition to age factors, and genetic testing can be used to prevent missed detection of ABO subtypes in neonates.
8.Gradient artificial bone repair scaffold regulates skeletal system tissue repair and regeneration
Yu ZHANG ; Ruian XU ; Lei FANG ; Longfei LI ; Shuyan LIU ; Lingxue DING ; Yuexi WANG ; Ziyan GUO ; Feng TIAN ; Jiajia XUE
Chinese Journal of Tissue Engineering Research 2025;29(4):846-855
BACKGROUND:Gradient artificial bone repair scaffolds can mimic unique anatomical features in musculoskeletal tissues,showing great potential for repairing injured musculoskeletal tissues. OBJECTIVE:To review the latest research advances in gradient artificial bone repair scaffolds for tissue engineering in the musculoskeletal system and describe their advantages and fabrication strategies. METHODS:The first author of the article searched the Web of Science and PubMed databases for articles published from 2000 to 2023 with search terms"gradient,bone regeneration,scaffold".Finally,76 papers were analyzed and summarized after the screening. RESULTS AND CONCLUSION:(1)As an important means of efficient and high-quality repair of skeletal system tissues,gradient artificial bone repair scaffolds are currently designed bionically for the natural gradient characteristics of bone tissue,bone-cartilage,and tendon-bone tissue.These scaffolds can mimic the extracellular matrix of native tissues to a certain extent in terms of structure and composition,thus promoting cell adhesion,migration,proliferation,differentiation,and regenerative recovery of damaged tissues to their native state.(2)Advanced manufacturing technology provides more possibilities for gradient artificial bone repair scaffold preparation:Gradient electrospun fiber scaffolds constructed by spatially differentiated fiber arrangement and loading of biologically active substances have been developed;gradient 3D printed scaffolds fabricated by layered stacking,graded porosity,and bio-3D printing technology;gradient hydrogel scaffolds fabricated by in-situ layered injections,simple layer-by-layer stacking,and freeze-drying method;and in addition,there are also scaffolds made by other modalities or multi-method coupling.These scaffolds have demonstrated good biocompatibility in vitro experiments,were able to accelerate tissue regeneration in small animal tests,and were observed to have significantly improved histological structure.(3)The currently developed gradient artificial bone repair scaffolds have problems such as mismatch of gradient scales,unclear material-tissue interactions,and side effects caused by degradation products,which need to be further optimized by combining the strengths of related disciplines and clinical needs in the future.
9.Panax notoginseng saponins regulate differential miRNA expression in osteoclast exosomes and inhibit ferroptosis in osteoblasts
Hongcheng TAO ; Ping ZENG ; Jinfu LIU ; Zhao TIAN ; Qiang DING ; Chaohui LI ; Jianjie WEI ; Hao LI
Chinese Journal of Tissue Engineering Research 2025;29(19):4011-4021
BACKGROUND:Steroid-induced femoral head necrosis is mostly caused by long-term and extensive use of hormones,but its specific pathogenesis is not yet clear and needs further study. OBJECTIVE:To screen out the differential miRNAs in osteoclast exosomes after the intervention of Panax notoginseng saponins,and on this basis,to further construct an osteogenic-related ferroptosis regulatory network to explore the potential mechanism and research direction of steroid-induced osteonecrosis of the femoral head. METHODS:MTT assay was used to detect the toxic effects of different concentrations of dexamethasone and different mass concentrations of Panax notoginseng saponins on Raw264.7 cell line.Tartrate resistant acid phosphatase staining and TUNEL assay were used to detect the effects of Panax notoginseng saponins on osteoclast inhibition and apoptosis.Exosomes were extracted from cultured osteoclasts with Panax notoginseng saponins intervention.Exosomes from different groups were sequenced to identify differentially expressed miRNAs.CytoScape 3.9.1 was used to construct and visualize the regulatory network between differentially expressed miRNAs and mRNAs.Candidate mRNAs were screened by GO analysis and KEGG analysis.Finally,the differential genes related to ferroptosis were screened out,and the regulatory network of ferroptosis-related genes was constructed. RESULTS AND CONCLUSION:(1)The concentration of dexamethasone(0.1 μmol/L)and Panax notoginseng saponins(1 736.85 μg/mL)suitable for intervention of Raw264.7 cells was determined by MTT assay.(2)Panax notoginseng saponins had an inhibitory effect on osteoclasts and could promote their apoptosis.(3)Totally 20 differentially expressed miRNAs were identified from osteoclast-derived exosome samples,and 11 differentially expressed miRNAs related to osteogenesis were predicted by target mRNAs.The regulatory networks of 4 up-regulated differentially expressed miRNAs corresponding to 155 down-regulated candidate mRNAs and 7 down-regulated differentially expressed miRNAs corresponding to 238 up-regulated candidate mRNAs were constructed.(4)Twenty-four genes related to ferroptosis were screened out from the differential genes.Finally,12 networks were constructed(miR-98-5p/PTGS2,miR-23b-3p/PTGS2,miR-425-5p/TFRC,miR-133a-3p/TFRC,miR-185-5p/TFRC,miR-23b-3p/NFE2L2,miR-23b-3p/LAMP2,miR-98-5p/LAMP2,miR-182-5p/LAMP2,miR-182-5p/TLR4,miR-23b-3p/ZFP36,and miR-182-5p/ZFP36).These results indicate that Panax notoginseng saponins may regulate osteoblast ferroptosis by regulating the expression of miRNAs derived from osteoclast exosomes,thus providing a new idea for the study of the mechanism of steroid-induced femoral head necrosis.

Result Analysis
Print
Save
E-mail