1.High frequency ultrasound combined with ultrasound-guided core needle biopsy for the diagnosis of primary thyroid lymphoma.
Li Long XU ; Shi Yan LI ; Jiang ZHU ; Jiang Hong LYU ; Ming Xuan ZHANG ; Li GAO ; Lei XIE ; Zhi Nong JIANG ; Guo Xiang FU
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2021;56(8):858-862
Objective: To investigate the sonographic features of primary thyroid lymphoma (PTL) and to evaluate the clinical significance of ultrasound-guided core needle biopsy (US-CNB) in PTL. Methods: A total of 24 patients with suspected PTL in Sir Run Run Shaw Hospital from January 2013 to June 2018 were analyzed retrospectively. All cases were confirmed by pathology, of them 23 patients received US-CNB and 1 patient chose operation without US-CNB, including 5 males and 19 females, aged from 39 to 75 years old. The effectiveness and safety of 23 patients with US-CNB were evaluated, and the sonographic features of 20 patients with PTL diagnosed by pathology were analyzed. Descriptive statistical methods were used in the study. Results: In the 23 patients with suspected PTL underwent US-CNB, 18 patients were diagnosed as PTL, 4 patients were respectively diagnosed as subacute thyroiditis, anaplastic carcinoma, Hashimoto's thyroiditis, and fibro thyroiditis, and the another patient was hard to diagnose by US-CNB and then was diagnosed as PTL by surgical biopsy. The success rate of US-CNB for diagnosis of PTL was 18/19, and no severe complications occurred in the patients with US-CNB. The other case was diagnosed as PTL by surgical biopsy without US-CNB. Sonographic features of 20 cases with PTL (18 cases diagnosed by US-CNB and 2 cases by surgery or surgery biopsy) were as follows: (1) Most nodules had irregular shapes and unsmooth margins; (2) Hypoechoic or markedly hypoechoic nodules with honeycombed or cord structures were observed in most cases; (3) Calcification was rare; (4) Multiple lesions were common; (5) Abundant intralesional vascularization was commonly observed; (6) Most cases had intensification of posterior acoustic enhancement; (7) Thyroid gland enlargement or with irregular shape; and (8) PTL often accompanied with lymph nodes enlargement in lateral neck or central region. Conclusion: PTL has certain sonographic features, with assistance of US-CNB, more accurate diagnosis of PTL can be obtained.
Adult
;
Aged
;
Biopsy, Large-Core Needle
;
Female
;
Humans
;
Image-Guided Biopsy
;
Lymphoma/diagnostic imaging*
;
Male
;
Middle Aged
;
Retrospective Studies
;
Thyroid Gland
;
Thyroid Neoplasms/diagnostic imaging*
;
Thyroid Nodule
;
Ultrasonography, Interventional
2.Feasibility of Adjustable Electrodes for Radiofrequency Ablation of Benign Thyroid Nodules
Jiyeong LEE ; Jung Hee SHIN ; Soo Yeon HAHN ; Ko Woon PARK ; Ji Soo CHOI
Korean Journal of Radiology 2020;21(3):377-383
OBJECTIVE: The purpose of this study was to evaluate a novel radiofrequency ablation (RFA) application utilizing an adjustable electrode for treatment of benign thyroid nodules.MATERIALS AND METHODS: From April 2011 to December 2018, 21 patients underwent RFA treatment on 21 thyroid nodules, utilizing an 18-gauge internally cooled electrode equipped with a size adjustable active tip. The peripheral nodule portions were ablated with the moving-shot technique and a shorter active tip, and the nodule centers were ablated with the fixed technique and a longer active tip. We assessed parameters including characteristics of the treated nodules, use of variablesized active tips, volume reduction rate, therapeutic success rate, and post-procedural complications. The therapeutic success rate was defined as a > 50% volume reduction of the initial nodule volume at the 6- or 12-month follow-up.RESULTS: The treated thyroid nodules were large enough to cause symptoms (mean volume, 29.6 mL). Two types of active tips per session were used for all nodules. The mean volume reduction rate at the last follow-up was 68.3 ± 4.4% and our therapeutic success rate was 90.5%. Both symptoms and cosmetic scores decreased significantly. Minor complications in three patients were recorded during and after the procedure.CONCLUSION: This initial study demonstrated that an adjustable electrode for RFA of benign thyroid nodules effectively and safely resulted in volume reduction.
Catheter Ablation
;
Electrodes
;
Follow-Up Studies
;
Humans
;
Thyroid Gland
;
Thyroid Nodule
;
Ultrasonography
3.Computer-Aided Diagnosis System for the Evaluation of Thyroid Nodules on Ultrasonography: Prospective Non-Inferiority Study according to the Experience Level of Radiologists
Sae Rom CHUNG ; Jung Hwan BAEK ; Min Kyoung LEE ; Yura AHN ; Young Jun CHOI ; Tae Yon SUNG ; Dong Eun SONG ; Tae Yong KIM ; Jeong Hyun LEE
Korean Journal of Radiology 2020;21(3):369-376
OBJECTIVE: To determine whether a computer-aided diagnosis (CAD) system for the evaluation of thyroid nodules is non-inferior to radiologists with different levels of experience.MATERIALS AND METHODS: Patients with thyroid nodules with a decisive diagnosis of benign or malignant nodule were consecutively enrolled from November 2017 to September 2018. Three radiologists with different levels of experience (1 month, 4 years, and 7 years) in thyroid ultrasound (US) reviewed the thyroid US with and without using the CAD system. Statistical analyses included non-inferiority testing of the diagnostic accuracy for malignant thyroid nodules between the CAD system and the three radiologists with a non-inferiority margin of 10%, comparison of the diagnostic performance, and the added value of the CAD system to the radiologists.RESULTS: Altogether, 197 patients were included in the study cohort. The diagnostic accuracy of the CAD system (88.48%, 95% confidence interval [CI] = 82.65–92.53) was non-inferior to that of the radiologists with less experience (1 month and 4 year) of thyroid US (83.03%, 95% CI = 76.52–88.02; p < 0.001), whereas it was inferior to that of the experienced radiologist (7 years) (95.76%, 95% CI = 91.37–97.96; p = 0.138). The sensitivity and negative predictive value of the CAD system were significantly higher than those of the less-experienced radiologists were, whereas no significant difference was found with those of the experienced radiologist. A combination of US and the CAD system significantly improved sensitivity and negative predictive value, although the specificity and positive predictive value deteriorated for the less-experienced radiologists.CONCLUSION: The CAD system may offer support for decision-making in the diagnosis of malignant thyroid nodules for operators who have less experience with thyroid US.
Cohort Studies
;
Diagnosis
;
Humans
;
Prospective Studies
;
Sensitivity and Specificity
;
Thyroid Gland
;
Thyroid Neoplasms
;
Thyroid Nodule
;
Ultrasonography
4.Ultrasonographic Demonstration of the Tissue Microvasculature in Children: Microvascular Ultrasonography Versus Conventional Color Doppler Ultrasonography
Joonghyun YOO ; Bo Kyung JE ; Ji Yung CHOO
Korean Journal of Radiology 2020;21(2):146-158
ultrasonography are its superiority in detection and visualization of the small blood vessels in tissues, providing radiologists with more information on the vascular structures. Therefore, it has shown particular value in the clinical fields. The aim of this study was to provide microvascular ultrasonographic images for the tissue microvasculature, including the brain, thyroid gland, kidney, urinary bladder, small bowel, ovary, testis, lymph node, and hemangiomas in children, focusing on the comparison with conventional color Doppler ultrasonographic images.]]>
Artifacts
;
Blood Vessels
;
Brain
;
Child
;
Female
;
Hemangioma
;
Humans
;
Kidney
;
Lymph Nodes
;
Microvessels
;
Ovary
;
Testis
;
Thyroid Gland
;
Ultrasonography
;
Ultrasonography, Doppler, Color
;
Urinary Bladder
5.Concordance of Three International Guidelines for Thyroid Nodules Classified by Ultrasonography and Diagnostic Performance of Biopsy Criteria
Younghee YIM ; Dong Gyu NA ; Eun Ju HA ; Jung Hwan BAEK ; Jin Yong SUNG ; Ji hoon KIM ; Won Jin MOON
Korean Journal of Radiology 2020;21(1):108-116
Thyroid Association/Korean Society of Thyroid Radiology, American Thyroid Association, and American College of Radiology for thyroid nodules classified by ultrasonography (US) and the diagnostic performance of simulated size criteria for malignant biopsies.MATERIALS AND METHODS: A total of 2586 thyroid nodules (≥ 1 cm) were collected from two multicenter study datasets. The classifications of the thyroid nodules were based on three different guidelines according to US categories for malignancy risk, and the concordance rate between the different guidelines was calculated for the classified nodules. In addition, the diagnostic performance of criteria related to four different simulated biopsy sizes was evaluated.RESULTS: The concordance rate of nodules classified as high- or intermediate-suspicion was high (84.1–100%), but low-suspicion or mildly-suspicious nodules exhibited relatively low concordance (63.8–83.8%) between the three guidelines. The differences in sensitivity, specificity, and accuracy between the guidelines were 0.7–19.8%, 0–40.9%, and 0.1–30.5%, respectively, when the original biopsy criteria were applied. The differences decreased to 0–5.9%, 0–10.9%, and 0.1–8.2%, respectively, when simulated, similar biopsy size criteria were applied. The unnecessary biopsy rate calculated with the original criteria (0–33.8%), decreased with the simulated biopsy size criteria (0–8.7%).CONCLUSION: We found a high concordance between the three guidelines for high- or intermediate-suspicion nodules, and the diagnostic performance of the biopsy criteria was approximately equivalent for each simulated size criterion. The difference in diagnostic performance between the three guidelines is mostly influenced by the various size thresholds for biopsies.]]>
Biopsy
;
Classification
;
Dataset
;
Sensitivity and Specificity
;
Thyroid Gland
;
Thyroid Neoplasms
;
Thyroid Nodule
;
Ultrasonography
6.Core-Needle Biopsy Does Not Show Superior Diagnostic Performance to Fine-Needle Aspiration for Diagnosing Thyroid Nodules
Ilah SHIN ; Eun Kyung KIM ; Hee Jung MOON ; Jung Hyun YOON ; Vivian Youngjean PARK ; Si Eun LEE ; Hye Sun LEE ; Jin Young KWAK
Yonsei Medical Journal 2020;61(2):161-168
thyroid nodules according to nodule size.MATERIALS AND METHODS: This retrospective study included 320 thyroid nodules from 320 patients who underwent both FNA and CNB at outside clinics and proceeded with surgery in our institution between July 2012 and May 2019. According to nodule size, the diagnostic performances of FNA and CNB were calculated using various combinations of test-negatives and test-positives defined by the Bethesda categories and were compared using the generalized estimated equation and the Delong method.RESULTS: There were 279 malignant nodules in 279 patients and 41 benign nodules in 41 patients. The diagnostic performance of FNA was mostly not different from CNB regardless of nodule size, except for negative predictive value, which was better for FNA than CNB when applying Criteria 1 and 2. When applying Criteria 3, the specificity and positive predictive value of FNA were superior to CNB regardless of size. When applying Criteria 4, diagnostic performance did not differ between FNA and CNB regardless of size. After applying Criteria 5, diagnostic performance did not differ between FNA and CNB in nodules ≥2 cm. However, in nodules ≥1 cm and all nodules, the sensitivity, accuracy, and negative predictive value of CNB were better than those of FNA.CONCLUSION: CNB did not show superior diagnostic performance to FNA for diagnosing thyroid nodules.]]>
Biopsy
;
Biopsy, Fine-Needle
;
Biopsy, Large-Core Needle
;
Humans
;
Methods
;
Retrospective Studies
;
Sensitivity and Specificity
;
Thyroid Gland
;
Thyroid Neoplasms
;
Thyroid Nodule
;
Ultrasonography
7.Concurrent Medullary Thyroid Carcinoma and Primary Thyroid Lymphoma (Diffuse Large B Cell Lymphoma): the First Case Report
Yeeun HAN ; Yon Hee KIM ; Hye Jeong KIM ; In Ho CHOI
International Journal of Thyroidology 2019;12(1):58-63
Cases of simultaneously occurring medullary thyroid carcinoma (MTC) and lymphoma are extremely rare. An 84-year-old woman visited the hospital due to dyspnea, resulting from rapidly aggravated enlarged neck mass. Ultrasonography revealed two lesions in the thyroid and they were diagnosed as concurrent medullary thyroid carcinoma and diffuse large B cell lymphoma after total thyroidectomy. A few cases simultaneously diagnosed with MTC and systemic lymphoma have been reported. However, the coexistence of MTC and primary thyroid lymphoma is extremely rare.
Aged, 80 and over
;
Carcinoma, Medullary
;
Dyspnea
;
Female
;
Humans
;
Lymphoma
;
Lymphoma, B-Cell
;
Neck
;
Thyroid Gland
;
Thyroid Neoplasms
;
Thyroidectomy
;
Ultrasonography
8.High Body Mass Index and Thyroid Stimulating Hormone Levels Do Not Affect Thyroid Nodule Selection for Fine-Needle Aspiration Biopsy after Ultrasound Evaluation
Hyun Gi KIM ; Hye Sun LEE ; Eun Kyung KIM ; Chung Mo NAM ; Hee Jung MOON ; Hae Kyoung JUNG ; Jin Young KWAK
International Journal of Thyroidology 2019;12(1):44-53
BACKGROUND AND OBJECTIVES: This study was to evaluate whether high body mass index (BMI) or thyroid stimulating hormone (TSH) level would affect selecting thyroid nodule for fine-needle aspiration biopsy (FNA) after ultrasound (US) evaluation. MATERIALS AND METHODS: A total of 3155 thyroid nodules (2159 benign and 996 malignant nodules) were included. Four grades of BMI and three levels of TSH were applied for grouping. US features of the thyroid nodules were divided into ‘probably benign’ and ‘suspicious for malignancy’ categories. Patients were grouped according to gender and univariate and multivariate logistic regression analysis were used to find the association between variables and malignancy. RESULTS: TSH levels were significantly higher in the malignant group (p<0.001). The grades of BMI did not show difference between the malignant and benign groups (females, p=0.074 and males, p=0.157). Younger age and ‘suspicious for malignancy’ US category were independent risk factors for malignancy in both genders. In females, a high TSH level (odds ratio=1.010, p<0.001) had significant association with malignancy. Except for younger age (odds ratio=0.998, p<0.001), no variable in nodules with ‘probably benign’ US category was significantly associated with malignancy. CONCLUSION: High TSH levels were more frequent in thyroid malignancy group, but neither high BMI nor high TSH level give additional information for FNA selection after US.
Biopsy, Fine-Needle
;
Body Mass Index
;
Female
;
Humans
;
Logistic Models
;
Male
;
Obesity
;
Risk Factors
;
Thyroid Gland
;
Thyroid Neoplasms
;
Thyroid Nodule
;
Thyrotropin
;
Ultrasonography
9.Ultrasonographic Characteristics of the Hyperfunctioning Thyroid Nodule and Predictive Factors for Thyroid Stimulating Hormone Suppression
International Journal of Thyroidology 2019;12(1):35-43
BACKGROUND AND OBJECTIVES: Thyroid scan is a good tool for diagnosis of hyperfunctioning thyroid nodules (HNs), however it has been limited in use in a primary clinical practice, because of its inconvenience and low accessibility. This study aimed to analyze ultrasonographic (US) characteristics of HNs and to predict HNs by US. MATERIALS AND METHODS: We included 114 patients who exhibited results of ‘hot’ nodule in the thyroid scan from 2008 to 2017. Analysis for US characteristics included 73 patients without unclear US images and other inevitable reasons. We compared US characteristics of HNs with cold nodules that showed “cold” in the thyroid scan. Additionally, we compared US characteristics of HNs between suppressed thyroid-stimulating hormone (TSH) (<0.25 uIU/mL) or normal TSH, and analysis receiver operating characteristics (ROC) curve for prediction of suppressed TSH among HNs. RESULTS: The HNs showed more partially cystic nodule, isoechoic echogenicity, hypervascularity and presence of halo in the US finding than the cold nodule. In subgroup analysis of nodules with TSH suppression among HNs, the TSH suppression nodules was lager in max size and volume than the normal TSH nodules. In ROC analyses for prediction of the TSH suppression among HNs, area under receiver operating characteristics curves was 0.736 in max size, 0.761 in volume. CONCLUSION: HNs showed more frequently partially cystic contents, isoechoic echogenicity, hypervascularity, and peripheral halo sign in US finding. Thyroid nodule size and volume were associated with suppressed TSH level of HNs, and optimal cutoff levels for prediction of TSH suppression among HNs were 2.6 cm and 1.13 cm3, respectively.
Diagnosis
;
Humans
;
ROC Curve
;
Thyroid Gland
;
Thyroid Nodule
;
Thyrotropin
;
Ultrasonography
10.Molecular Testing of Thyroid Indeterminate Nodules for Clinical Management Decision
Hyeung Kyoo KIM ; Euy Young SOH
International Journal of Thyroidology 2019;12(1):9-14
Thyroid nodules are the most common endocrine tumor. Ultrasonography and fine-needle aspiration (FNA) are currently accurate diagnostic tools for evaluating thyroid nodules. However, 10–30% of FNA specimens are cytologically indeterminate. Making an accurate diagnosis between benign and malignant nodules is important so that patients with malignant nodule receive proper treatment and patients with benign nodule can avoid unnecessary treatment. Several genetic changes such as point mutations of the BRAF or RAS and rearrangements of the RET/PTC1, RET/PTC3, PAX8/PPARY are used to adjust to indeterminate FNA. Such a mutational analysis has an excellent positive predictive value (PPV), but there is a weakness in the low negative predictive value (NPV). Gene-expression classifier (GEC) has been found helpful in identify nodules that are benign rather than malignant. GEC has an excellent NPV, but there is a weakness of low PPV. Multiplatform mutational and miRNA test (MPT) and next-generation sequencing assay (NGS) are being studied to compensate for these weaknesses. Molecular tests appear to be a good solution for improving the accuracy of indeterminate FNA cytology specimens and support the clinical management decisions in patients with indeterminate cytologic nodules, but further prospective multicenter trials are required for validation of reported findings and need evaluation of cost-effectiveness. This paper will review recently available molecular diagnostic tools of thyroid nodule.
Biopsy, Fine-Needle
;
Diagnosis
;
Humans
;
MicroRNAs
;
Multicenter Studies as Topic
;
Pathology, Molecular
;
Point Mutation
;
Prospective Studies
;
Thyroid Gland
;
Thyroid Neoplasms
;
Thyroid Nodule
;
Ultrasonography

Result Analysis
Print
Save
E-mail