1.Five-year outcomes of metabolic surgery in Chinese subjects with type 2 diabetes.
Yuqian BAO ; Hui LIANG ; Pin ZHANG ; Cunchuan WANG ; Tao JIANG ; Nengwei ZHANG ; Jiangfan ZHU ; Haoyong YU ; Junfeng HAN ; Yinfang TU ; Shibo LIN ; Hongwei ZHANG ; Wah YANG ; Jingge YANG ; Shu CHEN ; Qing FAN ; Yingzhang MA ; Chiye MA ; Jason R WAGGONER ; Allison L TOKARSKI ; Linda LIN ; Natalie C EDWARDS ; Tengfei YANG ; Rongrong ZHANG ; Weiping JIA
Chinese Medical Journal 2025;138(4):493-495
2.Application of functional perforator flap transplantation with chimeric iliac bone flap in reconstruction of composite tissue defects of hand or foot.
Junjie LI ; Huihui GUO ; Bin LUO ; Huihai YAN ; Mingming MA ; Tengfei LI ; Tao NING ; Wei JIAO
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(9):1098-1105
OBJECTIVE:
To evaluate the effectiveness of functional perforator flaps utilizing the superficial circumflex iliac artery as a vascular pedicle, as well as chimeric iliac bone flaps, in the reconstruction of composite tissue defects in the hand and foot.
METHODS:
A retrospective review of the clinical data from 13 patients suffering from severe hand or foot injuries, treated between May 2019 and January 2025, was conducted. The cohort comprised 8 males and 5 females, with ages ranging from 31 to 67 years (mean, 48.5 years). The injuries caused by mechanical crush incidents (n=9) and traffic accidents (n=4). The distribution of injury sites included 8 cases involving the hand and 5 cases involving the foot. Preoperatively, all patients exhibited bone defects ranging from 2.0 to 6.5 cm and soft tissue defects ranging from 10 to 210 cm2. Reconstruction was performed using functional perforator flaps based on the superficial circumflex iliac artery and chimeric iliac bone flaps. The size of iliac bone flaps ranged from 2.5 cm×1.0 cm×1.0 cm to 7.0 cm×2.0 cm×1.5 cm, while the size of the soft tissue flaps ranged from 4 cm×3 cm to 15 cm×8 cm. In 1 case with a significant hand defect, a posterior interosseous artery perforator flap measuring 10.0 cm×4.5 cm was utilized as an adjunct. Likewise, an anterolateral thigh perforator flap measuring 25 cm×7 cm was combined in 1 case involving a foot defect. All donor sites were primarily closed. Postoperative flap survival was monitored, and bone healing was evaluated through imaging examination. Functional outcomes were assessed based on the location of the defects: for hand injuries, grip strength, pinch strength, and flap two-point discrimination were measured; for foot injuries, the American Orthopaedic Foot & Ankle Society (AOFAS) score, visual analogue scale (VAS) score, Maryland Foot Score, plantar pressure distribution and gait symmetry index (GSI) were evaluated.
RESULTS:
All flaps survived completely, with primary healing observed at both donor and recipient sites. All patients were followed up 6-18 months (mean, 12.2 months). No significant flap swelling or deformity was observed. Imaging examination showed a bone callus crossing rate of 92.3% (12/13) at 3 months after operation, and bone density recovered to more than 80% of the healthy side at 6 months. The time required for bone flap integration ranged from 2 to 6 months (mean, 3.2 months). One patient with a foot injury exhibited hypertrophic scarring at the donor site; however, no major complication, such as infection or bone nonunion, was noted. At 6 months after operation, grip strength in 8 patients involving the hand recovered to 75%-90% of the healthy side (mean, 83.2%), while pinch strength recovered to 70%-85% (mean, 80%). Flap two-point discrimination ranged from 8 to 12 mm, approaching the sensory capacity of the healthy side (5-8 mm). Among the 5 patients involving the foot, the AOFAS score at 8 months was 80.5±7.3, VAS score was 5.2±1.6. According to the Maryland Foot Score, 2 cases were rated as excellent and 3 as good. Gait analysis at 6 months after operation showed GSI above 90%, with plantar pressure distribution closely resembling that of the contralateral foot.
CONCLUSION
The use of functional perforator flaps based on the superficial circumflex iliac artery, combined with chimeric iliac bone flaps, provides a reliable vascular supply and effective functional restoration for the simultaneous repair of composite bone and soft tissue defects in the hand or foot. This technique represents a viable and effective reconstructive option for composite tissue defects in these anatomical regions.
Humans
;
Male
;
Middle Aged
;
Female
;
Perforator Flap/transplantation*
;
Adult
;
Plastic Surgery Procedures/methods*
;
Hand Injuries/surgery*
;
Aged
;
Retrospective Studies
;
Foot Injuries/surgery*
;
Ilium/transplantation*
;
Iliac Artery/surgery*
;
Soft Tissue Injuries/surgery*
;
Bone Transplantation/methods*
;
Treatment Outcome
3.Evaluation of the accuracy of three-dimensional data acquisition from liquid- interference surfaces assisted by a scanner head with a compressed airflow system.
Xinkai XU ; Jianjiang ZHAO ; Sukun TIAN ; Zhongning LIU ; Xiaoyi ZHAO ; Xiaobo ZHAO ; Tengfei JIANG ; Xiaojun CHEN ; Chao MA ; Yuchun SUN
Journal of Peking University(Health Sciences) 2025;57(1):121-127
OBJECTIVE:
To quantitatively evaluate the accuracy of data obtained from liquid-interference surfaces using an intraoral 3D scanner (IOS) integrated with a compressed airflow system, so as to provide clinical proof of accuracy for the application of the compressed airflow system-based scanning head in improving data quality on liquid-interference surfaces.
METHODS:
The study selected a standard model as the scanning object, adhering to the "YY/T 1818-2022 Dental Science Intraoral Digital Impression Scanner" guidelines, a standard that defined parameters for intraoral scanning. To establish a baseline for accuracy, the ATOS Q 12M scanner, known for its high precision, was used to generate true reference values. These true values served as the benchmark for evaluating the IOS performance. Building on the design of an existing scanner, a new scanning head was developed to integrate with a compressed airflow system. This new design aimed to help the IOS capture high-precision data on surfaces where liquid-interference, such as saliva, might otherwise degrade scanning accuracy. The traditional scanning method, without airflow assistance, was employed as a control group for comparison. The study included five groups in total, one control group and four experimental groups, to investigate the effects of scanning lens obstruction, airflow presence, liquid media, and the use of the new scanning head on scanning process and accuracy. Each group underwent 15 scans, generating ample data for a robust statistical comparison. By evaluating trueness and precision in each group, the study assessed the impact of the compressed airflow system on the accuracy of IOS data collected from liquid-interference surfaces. Additionally, we selected Elite and Primescan scanners as references for numerical accuracy values.
RESULTS:
The scanning accuracy on liquid-interference surfaces was significantly reduced in terms of both trueness and precision [Trueness: 18.5 (6.5) vs. 38.0 (6.7), P < 0.05; Precision: 19.1 (8.5) vs. 31.7 (15.0), P < 0.05]. The use of the new scanning head assisted by the compressed airflow system significantly improved the scanning accuracy [Trueness: 22.3(7.6) vs. 38.0 (6.7), P < 0.05; Precision: 25.8 (9.6) vs. 31.7 (15.0), P < 0.05].
CONCLUSION
The scanning head based on the compressed airflow system can assist in improving the accuracy of data obtained from liquid-interference surfaces by the IOS.
Imaging, Three-Dimensional/methods*
;
Humans
;
Dental Impression Technique/instrumentation*
4.Vascular suture, closure and occlusion devices at femoral artery puncture hemostasis after neuro-intervention: a clinical comparative study
Shuailong SHI ; Shuhai LONG ; Sun YU ; Chengcheng SHI ; Ji MA ; Renying MIAO ; Yan SONG ; Xinwei HAN ; Tengfei LI
Chinese Journal of Radiology 2024;58(1):71-78
Methods:From February 2018 to January 2022, the clinical data of 1 123 patients who underwent Starclose vascular closure device, Angio-Seal and Exoseal vascular occlusion devices and Perclose ProGlide vascular suture device at femoral artery puncture hemostasis after neuro-intervention, in the Department of Interventional Radiology (Eastern District), The First Affiliated Hospital of Zhengzhou University, were retrospectively analyzed. The patients were divided into three groups based on the intervention method: the closure group (Starclose, n=271), the occlusion group (Angio-Seal, n=327 and Exoseal, n=352) and the suture group (ProGlide, n=173). Next, the hemostatic efficacy and complications associated with the three devices were analyzed and compared. Additionally, regression analysis was conducted to identify any relevant factors that may contribute to complications. Results:Three vascular hemostatic devices demonstrated effective hemostasis and the success rate were 92.6% in the closure group (Starclose), 93.4% in the occlusion group (Angio-Seal 93.0% and Exoseal 93.8%) and 89.6% in the suture group (ProGlide). There was no statistically significant difference( χ2=3.026, P=0.388). Single or multiple complications were observed in 102 patients (9.1%), including local oozing (16 cases in the closure group, 39 cases in the occlusion group, 13 cases in the suture group), local hematoma (14 cases in the closure group, 31 cases in the occlusion group, 11 cases in the suture group), pseudoaneurysm (13 cases in the closure group, 35 cases in the occlusion group, 10 cases in the suture group), local infection (2 cases in the closure group, 3 cases in the occlusion group, 1 case in the suture group). There were no statistically significant differences ( P>0.05). Moreover, serious complications such as femoral artery occlusion, embolus shedding and permanent nerve injury weren′t observed in the three groups. Multivariate logistic regression analysis revealed that overweight ( OR=1.562,95% CI 1.023—2.385, P=0.039), femoral artery with calcified plaque ( OR=1.934,95% CI 1.172-3.189, P=0.010), combined use of multiple antiplatelet drugs ( OR=1.769,95% CI 1.103—2.839, P=0.018), use of an 8F sheath( OR=2.824,95% CI 1.406—5.671, P=0.004) and the operator′s proficiency ( OR=0.508,95% CI 0.328—0.788, P=0.002) were the independent factors influencing complications, of which the first four were identified as risk-promoting factors for complications while the operator′s rich experience and high proficiency were the protective factors. Conclusions:Three hemostatic devices demonstrate effective hemostasis and comparable rates of complications at femoral artery puncture hemostasis after neuro-intervention. Overweight, femoral artery with calcified plaque, combined use of multiple antiplatelet drugs, use of an 8 F sheath and the operator′s proficiency were independent factors influencing complications.Ojective:To investigate the efficacy and complications associated with vascular suture, closure and occlusion devices at femoral artery puncture hemostasis after neuro-intervention.
5.Advances and Challenges in the Research of Integration Methods of Animal Experimental Evidence
Qingyong ZHENG ; Tengfei LI ; Jianguo XU ; Yongjia ZHOU ; Zhichao MA ; Na WANG ; Molan LI ; Wenjing YANG ; Peirun WU ; Haidong WANG ; Jinhui TIAN
Laboratory Animal and Comparative Medicine 2024;44(5):567-576
Integrating evidence from animal experiments is a critical component of biomedical research, providing essential prior information for in-depth investigations of disease mechanisms and new drug development. Animal models have played an irreplaceable role in simulating human diseases. However, the integration of evidence from animal experiments has faced numerous challenges, including insufficient emphasis, significant heterogeneity in study designs, high publication bias, and discrepancies with clinical research practices. This paper first identifies existing issues in the original research evidence from animal experiments, such as the selection and applicability of animal models, considerations in the design of experimental studies, and factors influencing the translation of animal experimental evidence. It then discusses various methods for integrating this evidence, including systematic review and meta-analysis, overview of systematic review/umbrella review, scoping review, and evidence mapping, while highlighting recent advancements in their application. Finally, the paper addresses the main challenges currently encountered in the integration of evidence from animal experiments and proposes targeted improvement strategies aimed at enhancing the efficiency of translating research outcomes into clinical practice and promoting the advancement of evidence-based medicine. By continuously optimizing original experimental research protocols and evidence integration practices, this work aims to establish a more efficient and scientific environment for the synthesis of evidence from animal experiments, ultimately contributing to clinical trials and human health.
6.Imaging features of severe unilateral transverse sinus and sigmoid sinus thromboses and efficacy and safety of intravascular interventional therapy in them
Tengfei LI ; Qi TIAN ; Shuailong SHI ; Jie YANG ; Ye WANG ; Zhen CHEN ; Yuncai RAN ; Baohong WEN ; Dong GUO ; Shaofeng SHUI ; Xinwei HAN ; Xiao LI ; Ji MA
Chinese Journal of Neuromedicine 2024;23(1):42-47
Objective:To summarize the imaging features of severe unilateral transverse sinus and sigmoid sinus thromboses, and evaluate the efficacy and safety of intravascular interventional therapy in them.Methods:Thirty-seven patients with severe unilateral transverse sinus and sigmoid sinus thromboses clinically mainly manifested as intracranial hypertension and accepted endovascular intervention in Department of Interventional Radiology, First Affiliated Hospital of Zhengzhou University from June 2012 to September 2022 were chosen; their clinical data were retrospectively analyzed and imaging features were summarized. Short-term efficacy was evaluated according to blood flow restoration degrees and pressure gradient reduction in the occlusive sinus and modified neurological symptoms before and after endovascular intervention. Hospitalized complications were observed; safety and long-term efficacy were evaluated according to postoperative clinical follow-up and imaging results 6-12 months after endovascular intervention.Results:(1) Preoperative brain MRI and (or) CT showed different degrees of swelling of the brain tissues, with the affected side as the target; mixed signals/density shadow could be seen in the blocked transverse sinus and sigmoid sinus; venous cerebral infarction or post-infarction cerebral hemorrhage could be combined in some patients. MRV, CTV and DSA showed poor or completely occluded transverse sinus and sigmoid sinus while normal in the contralateral side; obvious thrombus filling-defect was observed in the occluded venous sinus after mechanical thrombolysis. (2) Occlusive sinus blood flow was restored in all patients after endovascular intervention, and pressure gradient of the occlusive segment decreased from (16.6±3.3) mmHg before to (2.8±0.8) mmHg after endovascular intervention. Before discharge, clinical symptoms of all patients were significantly improved (modified Rankin scale [mRS] scores of 0 in 30 patients, 1 in 5 patients, 2 in 1 patient and 3 in 1 patient), and 2 patients had unilateral limb movement disorder (muscle strength grading III and IV, respectively). All patients received clinical follow-up for (9.6±3.0) months. At the last follow-up, neurological function obviously improved compared with that before endovascular intervention, without new neurosystem-related symptoms (mRS scores of 0 in 30 patients, 1 in 6, and 2 in 1 patient). In 34 patients received MRV or DSA follow-up, 28 had complete recanalization of occlusive sinus and 6 had partial recanalization, without obvious stenosis or recurrent occlusion.Conclusions:Severe unilateral transverse sinus and sigmoid sinus thrombosis can cause local intracranial venous blood stasis, and then cause "increased regional venous sinus pressure", which is manifested as unilateral brain tissue swelling and even venous cerebral infarction or post-infarction cerebral hemorrhage. Early diagnosis and endovascular intervention can obviously improve the prognosis of these patients, enjoying good safety.
7.OCT and IVUS evaluating stent apposition and endothelialization after FD implantation in aneurysm animal models
Ji MA ; Shuhai LONG ; Jie YANG ; Zhen LI ; Haiqiang SANG ; Yi TANG ; Yuncai RAN ; Yong ZHANG ; Baohong WEN ; Shanshan XIE ; Ke CHEN ; Enjie LIU ; Xinwei HAN ; Tengfei LI
Chinese Journal of Neuromedicine 2024;23(3):256-262
Objective:To investigate the application value of optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in evaluating flow diverter (FD) apposition and endothelialization in aneurysm animal models, and analyze the effect of incomplete stent apposition (ISA) on aneurysm lumen healing and stent endothelialization.Methods:Lateral common carotid artery aneurysm models in swines were established by surgical method and then FD was implanted. Immediately after surgery, OCT and IVUS were used to evaluate the locations and degrees of ISA, and difference between these 2 methods in evaluating FD apposition was compared. DSA was performed at 12 weeks after surgery to evaluate the aneurysm occlusion (Kamran grading) and stent patency. OCT and IVUS were used again to observe the stent endothelial situation; by comparing with histopathologic results, effect of ISA on aneurysm healing and stent endothelialization was analyzed.Results:Lateral common carotid artery aneurysm models in 6 swines were established, and 6 Tubridge FDs were successfully implanted. Compared with IVUS (3 stents, 4 locus), OCT could detect more ISA (6 stents, 14 locus); and the vascular diameter change area (7 locus), aneurysm neck area (4 locus) and the head and tail of FD (3 locus) were the main sites of FD malapposition; average distance between stent wire and vessel wall was (560.14±101.48) μm. At 12 weeks after surgery, DSA showed that 1 patient had a little residual contrast agent at the aneurysm neck (Kamran grading 3), and the remaining 5 had complete aneurysm occlusion (Kamran grading 4). One FD had moderate lumen stenosis, and the other 5 FDs had lumen patency. OCT indicated mostly disappeared acute ISA; ISA proportion decreased to 21.4 % (3/14), including 2 in the aneurysm neck and 1 in the partial stent. Histopathological results showed bare stent woven silk, without obvious endothelial coverage; in one FD with luminal stenosis, intimal hyperplasia was mainly composed of vascular smooth muscle cells.Conclusion:In carotid artery aneurysm model with FD implantation, OCT can detect more ISA than IVUS; most acute ISA have good outcome at 12 th week of follow-up, while severe ISA can cause delayed FD endothelialization and delayed aneurysm occlusion.
8.Analysis of molecular epidemic characteristics of H3N2 influenza viruses in Guangzhou City during the COVID-19 pandemic
Lan CAO ; Tengfei ZHOU ; Yiyun CHEN ; Mengmeng MA ; Dan XIA ; Yanhui LIU ; Kuibiao LI ; Biao DI ; Pengzhe QIN ; Zhoubin ZHANG
Chinese Journal of Preventive Medicine 2024;58(3):351-357
To monitor and analyze the molecular variation of the H3N2 influenza virus in Guangzhou during the COVID-19 pandemic, respiratory samples of influenza-like cases from influenza monitoring sentinel hospitals were collected from influenza monitoring sentinel hospitals for virus isolation and whole genome sequencing. The results showed that during COVID-19, there was only one peak of H3N2 influenza in the second quarter of 2022 in Guangzhou (the positive rate was 52.23%), and the epidemic intensity and duration were both higher than those in 2019. The HA gene and NA gene of the epidemic strain in Guangzhou in 2022 belonged to the 3C.2a1b. 2a. 1a. 1 branch, which had a good antigenic site matching with the vaccine strain (A/Cambodia/e0826360/2020) from 2021 to 2022 and had no antigen drift. In 2022 strains, the variation of antigen determinant mainly occurred in the I48T of C region, while no variation occurred in the A, B, D, and E regions. The binding site of the HA protein receptor was consistent with the vaccine strain (A/Cambodia/e0826360/2020). Most of the strains in 2022 carried 13 glycosylation sites on the HA protein, but an outbreak of strains caused a loss of glycosylation sites at 24-NST. In conclusion, the strains that caused the epidemic of H3N2 influenza in Guangzhou in 2022 were not evolved or transmitted from the local strains in 2019 during the COVID-19 pandemic.
9.Analysis of molecular epidemic characteristics of H3N2 influenza viruses in Guangzhou City during the COVID-19 pandemic
Lan CAO ; Tengfei ZHOU ; Yiyun CHEN ; Mengmeng MA ; Dan XIA ; Yanhui LIU ; Kuibiao LI ; Biao DI ; Pengzhe QIN ; Zhoubin ZHANG
Chinese Journal of Preventive Medicine 2024;58(3):351-357
To monitor and analyze the molecular variation of the H3N2 influenza virus in Guangzhou during the COVID-19 pandemic, respiratory samples of influenza-like cases from influenza monitoring sentinel hospitals were collected from influenza monitoring sentinel hospitals for virus isolation and whole genome sequencing. The results showed that during COVID-19, there was only one peak of H3N2 influenza in the second quarter of 2022 in Guangzhou (the positive rate was 52.23%), and the epidemic intensity and duration were both higher than those in 2019. The HA gene and NA gene of the epidemic strain in Guangzhou in 2022 belonged to the 3C.2a1b. 2a. 1a. 1 branch, which had a good antigenic site matching with the vaccine strain (A/Cambodia/e0826360/2020) from 2021 to 2022 and had no antigen drift. In 2022 strains, the variation of antigen determinant mainly occurred in the I48T of C region, while no variation occurred in the A, B, D, and E regions. The binding site of the HA protein receptor was consistent with the vaccine strain (A/Cambodia/e0826360/2020). Most of the strains in 2022 carried 13 glycosylation sites on the HA protein, but an outbreak of strains caused a loss of glycosylation sites at 24-NST. In conclusion, the strains that caused the epidemic of H3N2 influenza in Guangzhou in 2022 were not evolved or transmitted from the local strains in 2019 during the COVID-19 pandemic.
10.New intraoral digital impression with pneumatic gingival retraction used in the restoration of crown for posterior teeth: a case report
Xinkai XU ; Meizi ZHANG ; Zhongning LIU ; Yuchun SUN ; Hu CHEN ; Weiwei LI ; Xiaoyi ZHAO ; Yongjie JIA ; Shujuan XIAO ; Chao MA ; Xiaojun CHEN ; Tengfei JIANG ; Xiaobo ZHAO ; Sukun TIAN
Chinese Journal of Stomatology 2024;59(10):1044-1048
In fixed prosthodontics, clear exposure of the preparation margin is the prerequisite for obtaining accurate digital impressions and improving the marginal fit of restorations. To resolve the issues associated with the cord retraction technique, such as pain, acute injury, and prolonged procedural time, this study proposes a new technology for intraoral digital impression taking with pneumatic gingival retraction. The new scanning head blows a high-speed airflow that instantaneously separates the free gingiva, locally exposing the subgingival preparation margin. Combined with the farthest point preservation stitching algorithm based on the distance from the normal vector and high-speed laser scanning photography, it achieves global preparation edge data and gingival reconstruction, realizing painless, non-invasive, and efficient precise acquisition of the preparation margin. Using this new technique, a patient with a full porcelain crown restoration on a posterior tooth was treated. The digital impression revealed a clear margin of the preparation, and the crown made from this data has a good marginal fit.

Result Analysis
Print
Save
E-mail