1.Real-world efficacy and safety of azvudine in hospitalized older patients with COVID-19 during the omicron wave in China: A retrospective cohort study.
Yuanchao ZHU ; Fei ZHAO ; Yubing ZHU ; Xingang LI ; Deshi DONG ; Bolin ZHU ; Jianchun LI ; Xin HU ; Zinan ZHAO ; Wenfeng XU ; Yang JV ; Dandan WANG ; Yingming ZHENG ; Yiwen DONG ; Lu LI ; Shilei YANG ; Zhiyuan TENG ; Ling LU ; Jingwei ZHU ; Linzhe DU ; Yunxin LIU ; Lechuan JIA ; Qiujv ZHANG ; Hui MA ; Ana ZHAO ; Hongliu JIANG ; Xin XU ; Jinli WANG ; Xuping QIAN ; Wei ZHANG ; Tingting ZHENG ; Chunxia YANG ; Xuguang CHEN ; Kun LIU ; Huanhuan JIANG ; Dongxiang QU ; Jia SONG ; Hua CHENG ; Wenfang SUN ; Hanqiu ZHAN ; Xiao LI ; Yafeng WANG ; Aixia WANG ; Li LIU ; Lihua YANG ; Nan ZHANG ; Shumin CHEN ; Jingjing MA ; Wei LIU ; Xiaoxiang DU ; Meiqin ZHENG ; Liyan WAN ; Guangqing DU ; Hangmei LIU ; Pengfei JIN
Acta Pharmaceutica Sinica B 2025;15(1):123-132
Debates persist regarding the efficacy and safety of azvudine, particularly its real-world outcomes. This study involved patients aged ≥60 years who were admitted to 25 hospitals in mainland China with confirmed SARS-CoV-2 infection between December 1, 2022, and February 28, 2023. Efficacy outcomes were all-cause mortality during hospitalization, the proportion of patients discharged with recovery, time to nucleic acid-negative conversion (T NANC), time to symptom improvement (T SI), and time of hospital stay (T HS). Safety was also assessed. Among the 5884 participants identified, 1999 received azvudine, and 1999 matched controls were included after exclusion and propensity score matching. Azvudine recipients exhibited lower all-cause mortality compared with controls in the overall population (13.3% vs. 17.1%, RR, 0.78; 95% CI, 0.67-0.90; P = 0.001) and in the severe subgroup (25.7% vs. 33.7%; RR, 0.76; 95% CI, 0.66-0.88; P < 0.001). A higher proportion of patients discharged with recovery, and a shorter T NANC were associated with azvudine recipients, especially in the severe subgroup. The incidence of adverse events in azvudine recipients was comparable to that in the control group (2.3% vs. 1.7%, P = 0.170). In conclusion, azvudine showed efficacy and safety in older patients hospitalized with COVID-19 during the SARS-CoV-2 omicron wave in China.
2.Different Tendon Reconstruction Techniques for Repairing Medial Meniscus Posterior Root Tears:A Biomechanical Study
Yian SUN ; Zhou ZHANG ; Qiang ZHAO ; Xindong ZHAO ; Ming ZHOU ; Liao SONG ; Fei TENG ; Daijun XIE ; Xu LI ; Meng WU ; Jin JIANG
Journal of Medical Biomechanics 2025;40(3):719-725
Objective Through in vitro experiments,biomechanical data of the transtibial pullout suture(TPS),tendon reconstruction(TR),and tendon reconstruction with suture augmentation(TRS)were collected,so as to evaluate the biomechanical effectiveness of tendon reconstruction for repairing medial meniscus posterior root tear(MMPRT).Methods Eighteen porcine knee joint models were divided into TPS,TR,and TRS groups.Sutures were used to fix the meniscal root in TPS group.Tendons were passed through an incision at the meniscal root in TR group.Tendons were passed through an incision at the meniscal root and secured at tendon-meniscus contact area with additional sutures in TRS group.The sutures and tendons were pulled out through tibial tunnels and fixed at the anteromedial tibia.All groups underwent failure load tests,and ultimate failure load,displacement at failure load,load at clinical failure,stiffness,and failure modes of the samples were recorded.Results The maximum failure load in TPS group was significantly higher than that in TR group(P<0.05),but there was no significant difference between TPS group and TRS group(P>0.05).The maximum failure load in TRS group was significantly higher than that in TR group(P<0.05).The displacement under failure load in TR group and TRS group was significantly lower than that in TPS group(P<0.05),but there was no significant difference between TR group and TRS group(P>0.05).There were no significant differences in the load under clinical failure among the 3 groups(P>0.05).The stiffness of TRS group was significantly greater than that of TPS group(P<0.05),but no significant difference was observed between TR group and TPS group,as well as between TR group and TRS group(P>0.05).All failures were caused by suture or tendon cutting through the meniscus.Conclusions The tendon reconstruction techniques is superior to the TPS in terms of failure displacement and stiffness,while the TRS further enhances the stability of the repair.
3.Polarity-extended Liquid Chromatography-Mass Spectrometry System for Prostate Cancer Biomarker Screening Based on Extracellular Vesicles
Lu-Lu XIAO ; Meng-Xuan CHEN ; Shan-Shan PAN ; Yi-Chen WANG ; Tao-Hong HUANG ; Qi-Sheng ZHONG ; Yong CHEN ; Teng-Fei XU ; Jia-Hui ZHAO ; Xue-Song LIU
Chinese Journal of Analytical Chemistry 2025;53(11):1848-1859,中插4-中插29
Integrated metabolomic and lipidomic profiling,utilizing liquid chromatography coupled with high-resolution mass spectrometry(LC-HRMS),has emerged as a pivotal strategy for biomarker discovery.However,the inherent polarity disparity between metabolites and lipids complicates simultaneous analysis.To address this,a dual-stationary phase polarity-extended liquid chromatography(PELC)system was developed,which surpassed conventional one-dimensional LC(1D-LC)by enabling comprehensive coverage of both polar and non-polar compounds within a single injection.This system enhanced chromatographic resolution,peak capacity,and throughput while minimizing analytical variability.Extracellular vesicles(EVs),lipid bilayer-enclosed nanoparticles ubiquitously present in biofluids,had gained prominence as reservoirs of cancer biomarkers due to their cargo stability and pathophysiological relevance.Herein,the application of PELC-HRMS for concurrent metabolome-lipidome profiling in EVs was pioneered.A total of 193 metabolites were identified using this technique coupled with MS-DIAL software and Human Metabolome Database.Subsequently,this technique was employed to explore potential biomarkers for prostate cancer(PCa).Multivariate analysis identified 17 differentially abundant metabolites in PCa,implicating dysregulated pathways including purine metabolism,starch and sucrose metabolism,galactose metabolism,cysteine and methionine metabolism,and biosynthesis of unsaturated fatty acids.Notably,creatine(AUC=0.92)and DG 42:5(AUC=0.80)demonstrated robust diagnostic efficacy,attributable to their broad polarity ranges and EV-specific enrichment.This study established PELC as a high-fidelity platform for multi-omics integration in complex biospecimens,advancing mechanistic insights into metabolic rewiring and disease pathophysiology.
4.Full free-breathing cardiac MR: feasibility and efficacy assessment
Fei TENG ; Wenli ZHOU ; Gang YIN ; Xinling YANG ; Jing AN ; Kai YANG ; Shihua ZHAO ; Minjie LU
Chinese Journal of Radiology 2025;59(10):1142-1148
Objective:To explore the feasibility and effectiveness of full free-breathing cardiac magnetic resonance (CMR) in clinical practice.Methods:The study prospectively included patients who underwent full free-breathing CMR and traditional breath-holding cine imaging between June 1 and June 30, 2024. An analysis and comparison were conducted on the image acquisition time, image quality, and left ventricular function parameters under two scanning methods, including left ventricular ejection fraction (LVEF), left ventricular cardiac output (LVCO),left ventricular end diastolic volume (LVEDV), left ventricular end diastolic volume index (LVEDVI), left ventricular end systolic volume (LVESV), left ventricular end systolic volume index (LVESVI), left ventricular stroke volume (LVSV), and left ventricular mass (LVM). In addition, the study conducted both quantitative and qualitative analyses of other sequences in full free-breathing CMR, including T 1 mapping, T 2 mapping, flow imaging, and late gadolinium enhancement (LGE). Group comparisons were performed using the Wilcoxon signed-rank test or paired t-test. Consistency assessments included Bland-Altman analysis, intraclass correlation coefficient ( ICC), and linear regression analysis. Results:Totally, 150 patients were recruited into the study. The average acquisition time of full free-breathing CMR was (22.1±3.1) min, with an average short axis cine sequence examination time of (2.7±0.4) min; The average acquisition time of short axis images in a breath-holding state was (4.9±1.4) min, which was significantly longer than the cine scan in the free-breathing state ( P0.001). The cine and LGE images quality scores obtained from full free-breathing CMR were 4 (4, 4) points and 5 (4, 5) points, respectively, while the cine image quality score obtained in a breath-holding state was 5 (4, 5) points. Compared with traditional breath-hold CMR, free-breathing CMR measurements showed slightly higher LVESV, and LVESVI, while LVEDV, LVEDVI, LVSV, LVCO, LVEF, and LVM were slightly lower, except for LVSV and LVCO, which showed no statistically significant difference, the differences in other cardiac function parameters were statistically significant ( P0.05). However, the two methods demonstrated good consistency( ICC0.947) and correlation (0.808 r0.993, P0.001). The Bland-Altman analysis showed that the bias for all cardiac function parameters was within 8.0%. The Native T 1 and T 2 values for free-breathing CMR were (1 277.5±57.0) ms and 40.1 (38.5, 41.4) ms, respectively, and the results of flow imaging and echocardiography were basically consistent. Conclusions:Free-breathing CMR is feasible and effective in clinical practice, showing a high level of consistency with left ventricular functional parameters obtained from traditional breath-hold scanning. It significantly shortens examination time and holds great clinical value for the promotion and widespread use of CMR.
5.Different Tendon Reconstruction Techniques for Repairing Medial Meniscus Posterior Root Tears:A Biomechanical Study
Yian SUN ; Zhou ZHANG ; Qiang ZHAO ; Xindong ZHAO ; Ming ZHOU ; Liao SONG ; Fei TENG ; Daijun XIE ; Xu LI ; Meng WU ; Jin JIANG
Journal of Medical Biomechanics 2025;40(3):719-725
Objective Through in vitro experiments,biomechanical data of the transtibial pullout suture(TPS),tendon reconstruction(TR),and tendon reconstruction with suture augmentation(TRS)were collected,so as to evaluate the biomechanical effectiveness of tendon reconstruction for repairing medial meniscus posterior root tear(MMPRT).Methods Eighteen porcine knee joint models were divided into TPS,TR,and TRS groups.Sutures were used to fix the meniscal root in TPS group.Tendons were passed through an incision at the meniscal root in TR group.Tendons were passed through an incision at the meniscal root and secured at tendon-meniscus contact area with additional sutures in TRS group.The sutures and tendons were pulled out through tibial tunnels and fixed at the anteromedial tibia.All groups underwent failure load tests,and ultimate failure load,displacement at failure load,load at clinical failure,stiffness,and failure modes of the samples were recorded.Results The maximum failure load in TPS group was significantly higher than that in TR group(P<0.05),but there was no significant difference between TPS group and TRS group(P>0.05).The maximum failure load in TRS group was significantly higher than that in TR group(P<0.05).The displacement under failure load in TR group and TRS group was significantly lower than that in TPS group(P<0.05),but there was no significant difference between TR group and TRS group(P>0.05).There were no significant differences in the load under clinical failure among the 3 groups(P>0.05).The stiffness of TRS group was significantly greater than that of TPS group(P<0.05),but no significant difference was observed between TR group and TPS group,as well as between TR group and TRS group(P>0.05).All failures were caused by suture or tendon cutting through the meniscus.Conclusions The tendon reconstruction techniques is superior to the TPS in terms of failure displacement and stiffness,while the TRS further enhances the stability of the repair.
6.Full free-breathing cardiac MR: feasibility and efficacy assessment
Fei TENG ; Wenli ZHOU ; Gang YIN ; Xinling YANG ; Jing AN ; Kai YANG ; Shihua ZHAO ; Minjie LU
Chinese Journal of Radiology 2025;59(10):1142-1148
Objective:To explore the feasibility and effectiveness of full free-breathing cardiac magnetic resonance (CMR) in clinical practice.Methods:The study prospectively included patients who underwent full free-breathing CMR and traditional breath-holding cine imaging between June 1 and June 30, 2024. An analysis and comparison were conducted on the image acquisition time, image quality, and left ventricular function parameters under two scanning methods, including left ventricular ejection fraction (LVEF), left ventricular cardiac output (LVCO),left ventricular end diastolic volume (LVEDV), left ventricular end diastolic volume index (LVEDVI), left ventricular end systolic volume (LVESV), left ventricular end systolic volume index (LVESVI), left ventricular stroke volume (LVSV), and left ventricular mass (LVM). In addition, the study conducted both quantitative and qualitative analyses of other sequences in full free-breathing CMR, including T 1 mapping, T 2 mapping, flow imaging, and late gadolinium enhancement (LGE). Group comparisons were performed using the Wilcoxon signed-rank test or paired t-test. Consistency assessments included Bland-Altman analysis, intraclass correlation coefficient ( ICC), and linear regression analysis. Results:Totally, 150 patients were recruited into the study. The average acquisition time of full free-breathing CMR was (22.1±3.1) min, with an average short axis cine sequence examination time of (2.7±0.4) min; The average acquisition time of short axis images in a breath-holding state was (4.9±1.4) min, which was significantly longer than the cine scan in the free-breathing state ( P0.001). The cine and LGE images quality scores obtained from full free-breathing CMR were 4 (4, 4) points and 5 (4, 5) points, respectively, while the cine image quality score obtained in a breath-holding state was 5 (4, 5) points. Compared with traditional breath-hold CMR, free-breathing CMR measurements showed slightly higher LVESV, and LVESVI, while LVEDV, LVEDVI, LVSV, LVCO, LVEF, and LVM were slightly lower, except for LVSV and LVCO, which showed no statistically significant difference, the differences in other cardiac function parameters were statistically significant ( P0.05). However, the two methods demonstrated good consistency( ICC0.947) and correlation (0.808 r0.993, P0.001). The Bland-Altman analysis showed that the bias for all cardiac function parameters was within 8.0%. The Native T 1 and T 2 values for free-breathing CMR were (1 277.5±57.0) ms and 40.1 (38.5, 41.4) ms, respectively, and the results of flow imaging and echocardiography were basically consistent. Conclusions:Free-breathing CMR is feasible and effective in clinical practice, showing a high level of consistency with left ventricular functional parameters obtained from traditional breath-hold scanning. It significantly shortens examination time and holds great clinical value for the promotion and widespread use of CMR.
7.Opportunities and challenges of marginal donor liver
Xinyi LU ; Fei TENG ; Hong FU ; Yuanyu ZHAO ; Liye ZHU ; Jiayong DONG ; Jiaxi MAO ; Wenyuan GUO
Organ Transplantation 2024;15(3):463-468
With persistent breakthrough and maturity of surgical procedures and postoperative immunosuppressive therapy, the survival rate of liver transplant recipients and grafts has been significantly increased. The shortage of donor liver has become the main obstacle for clinical development of liver transplantation. How to expand the source of donor liver has become an urgent issue. Groundbreaking progresses have been made in the use of common marginal donor livers in clinical liver transplantation, such as elderly donor liver, steatosis donor liver, viral hepatitis donor liver and liver from donation after cardiac death. Nevertheless, multiple restrictions still exist regarding the use of marginal donor liver. Consequently, the definition of marginal donor liver and research progress in the application of common marginal donor livers were reviewed, and the opportunities and challenges of mariginal donoor liver were illustrated, aiming to provide reference for expanding the donor pool for clinical liver transplantation and bringing benefits to more patients with end-stage liver disease.
8.Research progress in risk factors of post-transplantation diabetes mellitus
Junfeng DONG ; Qiang XUE ; Fei TENG ; Yuanyu ZHAO ; Hao YIN
Organ Transplantation 2024;15(1):145-150
Solid organ transplantation has significantly prolonged the survival of patients with end-stage diseases. However, long-term use of immunosuppressants will increase the risk of post-transplantation diabetes mellitus (PTDM) in the recipients, thereby elevating the risk of infection, cardiovascular disease and death. In recent years, with persistent improvement of diagnostic criteria of PTDM, clinicians have deepened the understanding of this disease. Compared with type 2 diabetes mellitus, PTDM significantly differs in pathophysiological characteristics and clinical progression. Hence, different treatment strategies should be adopted. Early identification of risk factors of organ transplant recipients, early diagnosis and intervention are of significance for improving the quality of life of recipients, prolonging the survival of grafts and reducing the fatality of recipients. Therefore, the diagnosis, incidence and risk factors of PTDM were reviewed in this article, aiming to provide reference for clinicians to deliver prompt diagnosis and intervention for PTDM.
9.Comparison of intracellular uptake and target protein binding characteristics of two BTK inhibitors with different selectivities
Teng ZHANG ; Ting-Fei TAN ; Ying-Li ZHAO ; Gong-Wei HAN ; Zi-Tong XIA ; Han-Bing SHI ; He-Ying LIU ; Jun-Ping WANG ; Quan XIA
Chinese Pharmacological Bulletin 2024;40(10):1899-1905
Aim To investigate the intracellular up-take and target protein binding characteristics of two Bruton's tyrosine kinase inhibitors(BTKi)with differ-ent selectivities to provide further insights into the mechanisms of drug off-target-related bleeding risk.Methods Ibrutinib(non-selective BTKi)and za-nubrutinib(selective BTKi)were used as study drugs.After incubation of MEC-1 cells and human platelets with drugs,the cellular thermal shift assay(CETSA)was combined with Western blot to obtain the melting curve and isothermal curve to analyze the binding char-acteristics of the two drugs with the target protein BTK.After incubation of MEC-1 cells and human platelets with drugs,the concentrations of the two drugs were detected by liquid chromatography-tandem mass spectrometry(LC-MS/MS)to analyze the intracellular uptake of the two drugs.Results CETSA analysis confirmed that zanubrutinib was more selective for the target protein BTK compared to ibrutinib.LC-MS/MS analysis showed that both drugs were uptaken intracel-lularly by MEC-1 cells and platelets in a concentration-dependent manner.Conclusions While BTKi targe-ting BTK to B lymphocytes exerts therapeutic effects,off-target effects on platelets due to differences in their intracellular uptake,and target-binding characteristics may be one of the reasons for the differences in bleed-ing risk across selective BTKi.
10.Investigation on vehicle occupant dummy applicability for under-foot impact loading conditions
Teng-Fei TIAN ; Fu-Hao MO ; Hao-Yang SU ; Can HUANG ; Hui ZHAO ; Jun LIU ; Bo SHANG ; Kui LI ; Jin-Long QIU
Chinese Journal of Traumatology 2024;27(4):235-241
Purpose::Under-foot impact loadings can cause serious lower limb injuries in many activities, such as automobile collisions and underbody explosions to military vehicles. The present study aims to compare the biomechanical responses of the mainstream vehicle occupant dummies with the human body lower limb model and analyze their robustness and applicability for assessing lower limb injury risk in underfoot impact loading environments.Methods::The Hybrid III model, the test device for human occupant restraint (THOR) model, and a hybrid human body model with the human active lower limb model were adopted for under-foot impact analysis regarding different impact velocities and initial lower limb postures.Results::The results show that the 2 dummy models have larger peak tibial axial force and higher sensitivity to the impact velocities and initial postures than the human lower limb model. In particular, the Hybrid III dummy model presented extremely larger peak tibial axial forces than the human lower limb model. In the case of minimal difference in tibial axial force, Hybrid III's tibial axial force (7.5 KN) is still 312.5% that of human active lower limb's (2.4 KN). Even with closer peak tibial axial force values, the biomechanical response curve shapes of the THOR model show significant differences from the human lower limb model.Conclusion::Based on the present results, the Hybrid III dummy cannot be used to evaluate the lower limb injury risk in under-foot loading environments. In contrast, potential improvement in ankle biofidelity and related soft tissues of the THOR dummy can be implemented in the future for better applicability.

Result Analysis
Print
Save
E-mail