1.Pregnancy complicated with antithrombin Ⅲ deficiency: a case report and literature review
Taoying LI ; Saisai WANG ; Mingli ZHOU ; Ziran ZHANG ; Baoju ZHU
Chinese Journal of Hematology 2024;45(S1):40-46
Objective:To report the diagnosis and treatment of a pregnant woman with antithrombin (AT) Ⅲ deficiency in pregnancy, and combine the diagnosis and treatment ideas with the literature.Methods:The clinical diagnosis and treatment process of one pregnant woman with AT-Ⅲ deficiency admitted to the Second Affiliated Hospital of Zhengzhou University from October 2023 to June 2024 were retrospectively analyzed. Combined with relevant literature, the effect of pregnancy with AT-Ⅲ deficiency on pregnancy outcome was summarized, and reference was provided for the formulation of anticoagulant regimen.Results:The patient had 3 adverse pregnancy histories and a deep venous thrombosis of the lower limbs. The AT activity fluctuated between 34% and 50% during this pregnancy. The patient received 3 transfusions of fresh frozen plasma during pregnancy and was administered low molecular weight heparin from pre-pregnancy until 24 hours before delivery. Warfarin, hydroxychloroquine, cyclosporine and methylprednisolone were added in the second trimester. The pregnancy was terminated at 35 weeks of gestation. The infant was born with a weight of 2,330 g and was transferred to the pediatric department for treatment. After 14 days, the infant was discharged. Follow-up to date has not revealed any abnormalities.Conclusion:Precise treatment of pregnancy with AT-Ⅲ deficiency can effectively improve pregnancy outcomes.
2.Pregnancy complicated with antithrombin Ⅲ deficiency: a case report and literature review
Taoying LI ; Saisai WANG ; Mingli ZHOU ; Ziran ZHANG ; Baoju ZHU
Chinese Journal of Hematology 2024;45(S1):40-46
Objective:To report the diagnosis and treatment of a pregnant woman with antithrombin (AT) Ⅲ deficiency in pregnancy, and combine the diagnosis and treatment ideas with the literature.Methods:The clinical diagnosis and treatment process of one pregnant woman with AT-Ⅲ deficiency admitted to the Second Affiliated Hospital of Zhengzhou University from October 2023 to June 2024 were retrospectively analyzed. Combined with relevant literature, the effect of pregnancy with AT-Ⅲ deficiency on pregnancy outcome was summarized, and reference was provided for the formulation of anticoagulant regimen.Results:The patient had 3 adverse pregnancy histories and a deep venous thrombosis of the lower limbs. The AT activity fluctuated between 34% and 50% during this pregnancy. The patient received 3 transfusions of fresh frozen plasma during pregnancy and was administered low molecular weight heparin from pre-pregnancy until 24 hours before delivery. Warfarin, hydroxychloroquine, cyclosporine and methylprednisolone were added in the second trimester. The pregnancy was terminated at 35 weeks of gestation. The infant was born with a weight of 2,330 g and was transferred to the pediatric department for treatment. After 14 days, the infant was discharged. Follow-up to date has not revealed any abnormalities.Conclusion:Precise treatment of pregnancy with AT-Ⅲ deficiency can effectively improve pregnancy outcomes.
3.Application of wireless wearable intelligent body temperature monitoring system in temperature monitor-ing of patients with abdominal surgery
Qiling LV ; Min PAN ; Taoying WANG ; Cuiying WU ; Liyun ZHAO ; Fudi ZHAO
Modern Clinical Nursing 2018;17(4):53-56
Objective To evaluate the effect of wireless wearable intelligent body temperature monitoring system on temperature monitoring of perioperative patients. Method The body temprature of 572 patients with abdoiminal surgery who hospitalized in our hospital from June 2017 to Juanuary 2018 was measured by mercury thermometers and wireless intelligent body temprature monitoring system four times a day for three days with toally 6864 times after surgery.The measured time and data by both ways were compared and its relativity were analyzed. Results The measured data by mercury thermometers and wireless intelligent body temprature monitoring system was compared with no statistical significance (P>0.05), but the time measured by wireless intelligent body temprature monitoring system was shorter (P<0.05). The measured data of two ways was postively related (r=0.962,P<0.05). Conclusions The measurement results by the wireless wearable intelligent body temperature monitoring system are the same as by mercury thermometers. The accuracy of the system is well validated, and it can improve the working efficiency of nurses.

Result Analysis
Print
Save
E-mail