1.Efficacy of endoscopy under general anesthesia for the detection of synchronous lesions in oro-hypopharyngeal cancer
Yoichiro ONO ; Kenshi YAO ; Yasuhiro TAKAKI ; Satoshi ISHIKAWA ; Kentaro IMAMURA ; Akihiro KOGA ; Kensei OHTSU ; Takao KANEMITSU ; Masaki MIYAOKA ; Takashi HISABE ; Toshiharu UEKI ; Atsuko OTA ; Hiroshi TANABE ; Seiji HARAOKA ; Satoshi NIMURA ; Akinori IWASHITA ; Susumu SATO ; Rumie WAKASAKI
Clinical Endoscopy 2023;56(3):315-324
Background/Aims:
Image-enhanced endoscopy can detect superficial oro-hypopharyngeal squamous cell carcinoma; however, reliable endoscopy of the pharyngeal region is challenging. Endoscopy under general anesthesia during transoral surgery occasionally reveals multiple synchronous lesions that remained undetected on preoperative endoscopy. Therefore, we aimed to determine the lesion detection capability of endoscopy under general anesthesia for superficial oro-hypopharyngeal squamous cell carcinoma.
Methods:
This retrospective study included 63 patients who underwent transoral surgery for superficial oropharyngeal squamous cell carcinoma between April 2005 and December 2020. The primary endpoint was to compare the lesion detection capabilities of preoperative endoscopy and endoscopy under general anesthesia. Other endpoints included the comparison of clinicopathological findings between lesions detected using preoperative endoscopy and those newly detected using endoscopy under general anesthesia.
Results:
Fifty-eight patients (85 lesions) were analyzed. The mean number of lesions per patient detected was 1.17 for preoperative endoscopy and 1.47 for endoscopy under general anesthesia. Endoscopy under general anesthesia helped detect more lesions than preoperative endoscopy did (p<0.001). The lesions that were newly detected on endoscopy under general anesthesia were small and characterized by few changes in color and surface ruggedness.
Conclusions
Endoscopy under general anesthesia for superficial squamous cell carcinoma is helpful for detecting multiple synchronous lesions.
2.Effects of elevation on shoulder joint motion: comparison of dynamic and static conditions
Takaki IMAI ; Takashi NAGAMATSU ; Junichi KAWAKAMI ; Masaki KARASUYAMA ; Nobuya HARADA ; Yu KUDO ; Kazuya MADOKORO
Clinics in Shoulder and Elbow 2023;26(2):148-155
Although visual examination and palpation are used to assess shoulder motion in clinical practice, there is no consensus on shoulder motion under dynamic and static conditions. This study aimed to compare shoulder joint motion under dynamic and static conditions. Methods: The dominant arm of 14 healthy adult males was investigated. Electromagnetic sensors attached to the scapular, thorax, and humerus were used to measure three-dimensional shoulder joint motion under dynamic and static elevation conditions and compare scapular upward rotation and glenohumeral joint elevation in different elevation planes and angles. Results: At 120° of elevation in the scapular and coronal planes, the scapular upward rotation angle was higher in the static condition and the glenohumeral joint elevation angle was higher in the dynamic condition (P<0.05). In scapular plane and coronal plane elevation 90°– 120°, the angular change in scapular upward rotation was higher in the static condition and the angular change in scapulohumeral joint elevation was higher in the dynamic condition (P<0.05). No differences were found in shoulder joint motion in the sagittal plane elevation between the dynamic and static conditions. No interaction effects were found between elevation condition and elevation angle in all elevation planes. Conclusions: Differences in shoulder joint motion should be noted when assessing shoulder joint motion in different dynamic and static conditions. Level of evidence: Level III, diagnostic cross-sectional study.
3.Recent advances in electron microscopy for the diagnosis and research of glomerular diseases
Kazuho HONDA ; Takashi TAKAKI ; Dedong KANG
Kidney Research and Clinical Practice 2023;42(2):155-165
Recent technical advances in the detection of backscattered electrons during scanning electron microscopy (SEM) have improved resolution and have provided several new technologies for research and clinical practice in kidney disease. The advances include three-dimensional (3D) electron microscopy (3D-EM), correlative light and electron microscopy (CLEM), low-vacuum SEM (LVSEM), and scanning transmission electron microscopy (STEM). 3D-EM analysis used to be laborious, but recently three different technologies, serial block-face SEM, focused ion beam SEM, and array tomography, have made 3D-EM easier by automating sectioning and the subsequent image acquisition in an SEM. CLEM is a method to correlate light microscopic images, especially immunofluorescent and electron microscopy images, providing detailed ultrastructure of the area of interest where the immunofluorescent marker is located. LVSEM enables the use of SEM on materials with poor electron conductivity. For example, LVSEM makes it possible for high resolution, 3D observation of paraffin sections. Finally, STEM is a method to observe ultrathin sections with improved resolution by using the focused electron beam scanning used in SEM and not the broad electron beam used in transmission electron microscopy. These technical advances in electron microscopy are promising to provide plenty of novel insights for understanding the pathogenesis and diagnosis of various glomerular diseases.
5.Utilization of desktop 3D printer-fabricated “Cost-Effective” 3D models in orthognathic surgery
Masato NARITA ; Takashi TAKAKI ; Takahiko SHIBAHARA ; Masashi IWAMOTO ; Takashi YAKUSHIJI ; Takashi KAMIO
Maxillofacial Plastic and Reconstructive Surgery 2020;42(1):24-
Background:
In daily practice, three-dimensional patient-specific jawbone models (3D models) are a useful tool in surgical planning and simulation, resident training, patient education, and communication between the physicians in charge. The progressive improvements of the hardware and software have made it easy to obtain 3D models. Recently, in the field of oral and maxillofacial surgery, there are many reports on the benefits of 3D models. We introduced a desktop 3D printer in our department, and after a prolonged struggle, we successfully constructed an environment for the “in-house” fabrication of the previously outsourced 3D models that were initially outsourced. Through various efforts, it is now possible to supply inexpensive 3D models stably, and thus ensure safety and precision in surgeries. We report the cases in which inexpensive 3D models were used for orthodontic surgical simulation and discuss the surgical outcomes.ReviewWe explained the specific CT scanning considerations for 3D printing, 3D printing failures, and how to deal with them. We also used 3D models fabricated in our system to determine the contribution to the surgery. Based on the surgical outcomes of the two operators, we compared the operating time and the amount of bleeding for 25 patients who underwent surgery using a 3D model in preoperative simulations and 20 patients without using a 3D model. There was a statistically significant difference in the operating time between the two groups.
Conclusions
In this article, we present, with surgical examples, our in-house practice of 3D simulation at low costs, the reality of 3D model fabrication, problems to be resolved, and some future prospects.
6.Utilization of desktop 3D printer-fabricated “Cost-Effective” 3D models in orthognathic surgery
Masato NARITA ; Takashi TAKAKI ; Takahiko SHIBAHARA ; Masashi IWAMOTO ; Takashi YAKUSHIJI ; Takashi KAMIO
Maxillofacial Plastic and Reconstructive Surgery 2020;42(1):24-
Background:
In daily practice, three-dimensional patient-specific jawbone models (3D models) are a useful tool in surgical planning and simulation, resident training, patient education, and communication between the physicians in charge. The progressive improvements of the hardware and software have made it easy to obtain 3D models. Recently, in the field of oral and maxillofacial surgery, there are many reports on the benefits of 3D models. We introduced a desktop 3D printer in our department, and after a prolonged struggle, we successfully constructed an environment for the “in-house” fabrication of the previously outsourced 3D models that were initially outsourced. Through various efforts, it is now possible to supply inexpensive 3D models stably, and thus ensure safety and precision in surgeries. We report the cases in which inexpensive 3D models were used for orthodontic surgical simulation and discuss the surgical outcomes.ReviewWe explained the specific CT scanning considerations for 3D printing, 3D printing failures, and how to deal with them. We also used 3D models fabricated in our system to determine the contribution to the surgery. Based on the surgical outcomes of the two operators, we compared the operating time and the amount of bleeding for 25 patients who underwent surgery using a 3D model in preoperative simulations and 20 patients without using a 3D model. There was a statistically significant difference in the operating time between the two groups.
Conclusions
In this article, we present, with surgical examples, our in-house practice of 3D simulation at low costs, the reality of 3D model fabrication, problems to be resolved, and some future prospects.
7.Clinical results of conservative management in patients with full-thickness rotator cuff tear: a meta-analysis
Masaki KARASUYAMA ; Masafumi GOTOH ; Keiji TAHARA ; Junichi KAWAKAMI ; Kazuya MADOKORO ; Takashi NAGAMATSU ; Takaki IMAI ; Nobuya HARADA ; Yu KUDO ; Naoto SHIBA
Clinics in Shoulder and Elbow 2020;23(2):86-93
Background:
Several systematic reviews have reported on the conservative treatment of full-thickness rotator cuff tears; however, clinical results of this treatment still remain determined.
Methods:
PubMed, Cochrane Library, PEDro, and CINAHL databases were systematically searched for randomized clinical trials and observational studies. Two independent researchers reviewed a total of 2,981 articles, 28 of which met the criteria for inclusion in the study. Clinical outcome measures included Constant score, visual analog scale score for pain, range of motion, and short-form 36. The meta-analysis used a linear mixed model weighted with the variance of the estimate.
Results:
The meta-analysis showed a significant improvement after surgery. Pain score is 26.2 mm (1 month) to 26.4 mm (3 months) and 24.8 mm (12 months) (P<0.05); active abduction: 153.2º (2 months), 159.0º (6 months), 168.1º (12 months) (P<0.05); Constant score: 67.8 points (2 months) to 77.2 points (12 months) (P<0.05); short-form 36 “vitality” section: 57.0 points (6 months) and 70.0 points (12 months) (P<0.05).
Conclusions
Our data confirmed the effectiveness of conservative treatment in patients with full-thickness rotator cuff tears 12 months post-intervention. The results suggest that conservative treatment for patients with full-thickness rotator cuff tears should be the first line of treatment before considering surgery.
8.Prognostic factors for maxillary sinus mucosal thickening following Le Fort I osteotomy: a retrospective analysis
Masashi IWAMOTO ; Miki WATANABE ; Masae YAMAMOTO ; Masato NARITA ; Takashi KAMIO ; Takashi TAKAKI ; Takahiko SHIBAHARA ; Akira KATAKURA
Maxillofacial Plastic and Reconstructive Surgery 2019;41(1):12-
BACKGROUND: Le Fort I osteotomy is one of the surgical procedures now routinely and safely performed. It is possible to move the maxilla in three dimensions, but it is necessary to separate the bones around the maxillary sinus. Therefore, with surgery, maxillary sinus mucosal thickening occurs. By knowing the changes in the sinus mucosa after surgery and the factors affecting it, it is possible to better predict the outcomes of surgery and contribute to safer surgery. In this study, thickening of maxillary sinus mucosa before and after surgery in Le Fort I osteotomy was evaluated using multidetector-row computed tomography (MDCT) images, and the changes in mucosal thickening and the related factors were examined. METHODS: Using MDCT images, the maxillary sinus mucosa of 125 patients who had undergone Le Fort I osteotomy was retrospectively evaluated before surgery, 1 month after surgery, and 1 year after surgery. On the MDCT images, the maxillary sinus was judged as mucosal thickening and classified into three grades according to the proportion occupying the maxillary sinus. In the evaluation of factors related to mucosal thickening, the following eight factors were examined: sex, age, diagnosis, operating time, amount of postoperative bleeding, with/without bone graft, with/without multisegmental osteotomy, and with/without macrolide therapy after surgery. RESULTS: The mean age at the time of surgery was 25.6 ± 8 years. Of all 125 patients, 66 had bilateral thickening, 19 had unilateral thickening, and 40 had no thickening. Factors that were significantly related to mucosal thickening were the operative time for the maxilla, bone grafts, and macrolide therapy after surgery. CONCLUSIONS: Operative time for the maxilla, bone grafts, and macrolide therapy after surgery were found to be related to mucosal thickening. In addition, MDCT scanning 1 month after surgery was considered to be appropriate for evaluation of maxillary sinus mucosal thickening.
Diagnosis
;
Hemorrhage
;
Humans
;
Maxilla
;
Maxillary Sinus
;
Mucous Membrane
;
Multidetector Computed Tomography
;
Operative Time
;
Orthognathic Surgery
;
Osteotomy
;
Retrospective Studies
;
Transplants
9.Trough level of infliximab is useful for assessing mucosal healing in Crohn's disease: a prospective cohort study.
Akihiro KOGA ; Toshiyuki MATSUI ; Noritaka TAKATSU ; Yasumichi TAKADA ; Masahiro KISHI ; Yutaka YANO ; Takahiro BEPPU ; Yoichiro ONO ; Kazeo NINOMIYA ; Fumihito HIRAI ; Takashi NAGAHAMA ; Takashi HISABE ; Yasuhiro TAKAKI ; Kenshi YAO ; Hirotsugu IMAEDA ; Akira ANDOH
Intestinal Research 2018;16(2):223-232
BACKGROUND/AIMS: Decreased trough levels of infliximab (TLI) and antibodies to infliximab (ATI) are associated with loss of response (LOR) in Crohn's disease. Two prospective studies were conducted to determine whether TLI or ATI better correlates with LOR (Study 1), and whether TLI could become a predictor of mucosal healing (MH) (Study 2). METHODS: Study 1 was conducted in 108 patients, including those with LOR and remission to compare ATI and TLI in discriminating the 2 conditions based on receiver operating characteristic (ROC) curve analyses. Study 2 involved 35 patients who were evaluated endoscopically. RESULTS: In Study 1, there were no differences between the 2 assays in ROC curve analyses; the TLI cutoff value for LOR was 2.6 µg/mL (sensitivity, 70.9%; specificity, 79.2%), and the ATI cutoff value was 4.9 µg/mL (sensitivity, 65.5%; specificity, 67.9%). The AUROC (area under the ROC curve) of TLI was greater than that of ATI. AUROC was useful for discriminating between the 2 conditions. In Study 2, the TLI was significantly higher in the colonic MH group than in the non-MH group (2.7 µg/mL vs. 0.5 µg/mL, P=0.032). CONCLUSIONS: TLI is better than ATI for clinically diagnosing LOR, and a correlation was observed between TLI and colonic MH.
Antibodies
;
Cohort Studies*
;
Colon
;
Crohn Disease*
;
Humans
;
Infliximab*
;
Prospective Studies*
;
ROC Curve
;
Sensitivity and Specificity
10.Successful Repair of a Traumatic Aortic Isthmus Pseudoaneurysm Concomitant with Right Diaphragmatic Hernia
Taisuke Nakayama ; Masashi Kano ; Shingo Isshiki ; Takashi Tominaga ; Hiroshi Ishitoya ; Katsuhiko Hiratani ; Takahiro Sawada ; Hirotsugu Kurobe ; Tetsuya Kitagawa ; Takaki Hori
Japanese Journal of Cardiovascular Surgery 2011;40(3):94-97
A 24-year-old woman underwent successful repair of a traumatic pseudoaneurysm of the aortic isthmus concomitant with right diaphragmatic hernia which developed after a traffic accident, and the steering wheel of the crashed car was considered responsible for both lesions. Due to the right diaphragmatic hernia, she could breathe mainly with the left lung only. The aortic isthmus aneurysm was considered to be a pseudoaneurysm, and because of the potential risk of rupture, we performed urgent aortic surgery. Prior to a left thoracotomy, we anastomosed an 8-mm prosthetic graft to the right axillary artery. When the left lung was collapsed in order to perform a femoro-femoral bypass, the SpO2 level of her right index finger and her cerebral rSO2 markedly decreased. Therefore, we administered additional perfusion via the right axillary artery, which provided sufficient oxygen to the upper body and brain. The patient underwent Marlex mesh reinforcement of the right diaphragmatic hernia 30 days after grafting, and is doing well 1 year postoperatively.


Result Analysis
Print
Save
E-mail