1.Clinical Characteristics and Early Outcomes of Stroke Revascularization in Cognitively Impaired Patients on Anti-dementia Medication
Ji Hye YANG ; Sung Jin PARK ; Min Hwan LEE ; Han-Bin LEE ; Ja Seong KOO ; Sang-Mi NOH ; Si-Ryung HAN ; Taewon KIM ; Hyun-Ji CHO ; Hae-Eun SHIN ; Sang Bong LEE ; Si Baek LEE ; A-Hyun CHO
Journal of Neurosonology and Neuroimaging 2025;17(2):31-36
Background:
Poor outcomes after acute ischemic stroke (AIS) revascularization are anticipated in patients with dementia due to advanced age, comorbidities, and reduced disease awareness. This study investigated clinical characteristics and short-term outcomes of AIS revascularization in patients undergoing dementia treatment.
Methods:
We retrospectively reviewed patients who underwent AIS revascularization therapy at eight centers of the Catholic University of Korea. Patients receiving anti-dementia medication for cognitive impairment before stroke onset were analyzed. Clinical characteristics and outcomes, including the modified Rankin Scale (mRS) score, hemorrhagic transformation, and mortality, were collected.
Results:
Among 1,379 patients who received AIS revascularization over 5 years, 13 (0.94%; mean age 83 years; 8 females) had a preexisting diagnosis of dementia (Alzheimer’s disease in 11, mild cognitive impairment in 2) and were on anti-dementia medication. Two patients underwent intravenous thrombolysis combined with endovascular therapy, whereas 11 underwent endovascular therapy alone. Most patients (11/13, 84.6%) presented with an unclear onset time. Stroke lesions were located in the right middle cerebral artery (MCA) in seven cases, left MCA in three, bilateral MCAs in one, and posterior circulation in two. Hemorrhagic transformation occurred in six patients (46%), of whom three (23%) were symptomatic. The mRS scores at discharge were 6 in two patients, 5 in one patient, 4 in nine patients, and 3 in one patient. Four patients died within 3 months of stroke onset.
Conclusion
The proportion of patients with cognitive impairment receiving anti-dementia medication among those undergoing stroke revascularization therapy was very small. The rates of hemorrhagic transformation and mortality were high. None of the patients achieved favorable outcomes at discharge.
2.Comparison of micro-flow imaging and contrast-enhanced ultrasonography in assessing segmental congestion after right living donor liver transplantation
Taewon HAN ; Woo Kyoung JEONG ; Jaeseung SHIN ; Dong Ik CHA ; Kyowon GU ; Jinsoo RHU ; Jong Man KIM ; Gyu-Seong CHOI
Ultrasonography 2024;43(6):469-477
Purpose:
This study aimed to determine whether micro-flow imaging (MFI) offers diagnostic performance comparable to that of contrast-enhanced ultrasonography (CEUS) in detecting segmental congestion among patients undergoing living donor liver transplantation (LDLT).
Methods:
Data from 63 patients who underwent LDLT between May and December 2022 were retrospectively analyzed. MFI and CEUS data collected on the first postoperative day were quantified. Segmental congestion was assessed based on imaging findings and laboratory data, including liver enzymes and total bilirubin levels. The reference standard was a postoperative contrast-enhanced computed tomography scan performed within 2 weeks of surgery. Additionally, a subgroup analysis examined patients who underwent reconstruction of the middle hepatic vein territory.
Results:
The sensitivity and specificity of MFI were 73.9% and 67.5%, respectively. In comparison, CEUS demonstrated a sensitivity of 78.3% and a specificity of 75.0%. These findings suggest comparable diagnostic performance, with no significant differences in sensitivity (P=0.655) or specificity (P=0.257) between the two modalities. Additionally, early postoperative laboratory values did not show significant differences between patients with and without congestion. The subgroup analysis also indicated similar diagnostic performance between MFI and CEUS.
Conclusion
MFI without contrast enhancement yielded results comparable to those of CEUS in detecting segmental congestion after LDLT. Therefore, MFI may be considered a viable alternative to CEUS.
3.Comparison of micro-flow imaging and contrast-enhanced ultrasonography in assessing segmental congestion after right living donor liver transplantation
Taewon HAN ; Woo Kyoung JEONG ; Jaeseung SHIN ; Dong Ik CHA ; Kyowon GU ; Jinsoo RHU ; Jong Man KIM ; Gyu-Seong CHOI
Ultrasonography 2024;43(6):469-477
Purpose:
This study aimed to determine whether micro-flow imaging (MFI) offers diagnostic performance comparable to that of contrast-enhanced ultrasonography (CEUS) in detecting segmental congestion among patients undergoing living donor liver transplantation (LDLT).
Methods:
Data from 63 patients who underwent LDLT between May and December 2022 were retrospectively analyzed. MFI and CEUS data collected on the first postoperative day were quantified. Segmental congestion was assessed based on imaging findings and laboratory data, including liver enzymes and total bilirubin levels. The reference standard was a postoperative contrast-enhanced computed tomography scan performed within 2 weeks of surgery. Additionally, a subgroup analysis examined patients who underwent reconstruction of the middle hepatic vein territory.
Results:
The sensitivity and specificity of MFI were 73.9% and 67.5%, respectively. In comparison, CEUS demonstrated a sensitivity of 78.3% and a specificity of 75.0%. These findings suggest comparable diagnostic performance, with no significant differences in sensitivity (P=0.655) or specificity (P=0.257) between the two modalities. Additionally, early postoperative laboratory values did not show significant differences between patients with and without congestion. The subgroup analysis also indicated similar diagnostic performance between MFI and CEUS.
Conclusion
MFI without contrast enhancement yielded results comparable to those of CEUS in detecting segmental congestion after LDLT. Therefore, MFI may be considered a viable alternative to CEUS.
4.Comparison of micro-flow imaging and contrast-enhanced ultrasonography in assessing segmental congestion after right living donor liver transplantation
Taewon HAN ; Woo Kyoung JEONG ; Jaeseung SHIN ; Dong Ik CHA ; Kyowon GU ; Jinsoo RHU ; Jong Man KIM ; Gyu-Seong CHOI
Ultrasonography 2024;43(6):469-477
Purpose:
This study aimed to determine whether micro-flow imaging (MFI) offers diagnostic performance comparable to that of contrast-enhanced ultrasonography (CEUS) in detecting segmental congestion among patients undergoing living donor liver transplantation (LDLT).
Methods:
Data from 63 patients who underwent LDLT between May and December 2022 were retrospectively analyzed. MFI and CEUS data collected on the first postoperative day were quantified. Segmental congestion was assessed based on imaging findings and laboratory data, including liver enzymes and total bilirubin levels. The reference standard was a postoperative contrast-enhanced computed tomography scan performed within 2 weeks of surgery. Additionally, a subgroup analysis examined patients who underwent reconstruction of the middle hepatic vein territory.
Results:
The sensitivity and specificity of MFI were 73.9% and 67.5%, respectively. In comparison, CEUS demonstrated a sensitivity of 78.3% and a specificity of 75.0%. These findings suggest comparable diagnostic performance, with no significant differences in sensitivity (P=0.655) or specificity (P=0.257) between the two modalities. Additionally, early postoperative laboratory values did not show significant differences between patients with and without congestion. The subgroup analysis also indicated similar diagnostic performance between MFI and CEUS.
Conclusion
MFI without contrast enhancement yielded results comparable to those of CEUS in detecting segmental congestion after LDLT. Therefore, MFI may be considered a viable alternative to CEUS.
5.Comparison of micro-flow imaging and contrast-enhanced ultrasonography in assessing segmental congestion after right living donor liver transplantation
Taewon HAN ; Woo Kyoung JEONG ; Jaeseung SHIN ; Dong Ik CHA ; Kyowon GU ; Jinsoo RHU ; Jong Man KIM ; Gyu-Seong CHOI
Ultrasonography 2024;43(6):469-477
Purpose:
This study aimed to determine whether micro-flow imaging (MFI) offers diagnostic performance comparable to that of contrast-enhanced ultrasonography (CEUS) in detecting segmental congestion among patients undergoing living donor liver transplantation (LDLT).
Methods:
Data from 63 patients who underwent LDLT between May and December 2022 were retrospectively analyzed. MFI and CEUS data collected on the first postoperative day were quantified. Segmental congestion was assessed based on imaging findings and laboratory data, including liver enzymes and total bilirubin levels. The reference standard was a postoperative contrast-enhanced computed tomography scan performed within 2 weeks of surgery. Additionally, a subgroup analysis examined patients who underwent reconstruction of the middle hepatic vein territory.
Results:
The sensitivity and specificity of MFI were 73.9% and 67.5%, respectively. In comparison, CEUS demonstrated a sensitivity of 78.3% and a specificity of 75.0%. These findings suggest comparable diagnostic performance, with no significant differences in sensitivity (P=0.655) or specificity (P=0.257) between the two modalities. Additionally, early postoperative laboratory values did not show significant differences between patients with and without congestion. The subgroup analysis also indicated similar diagnostic performance between MFI and CEUS.
Conclusion
MFI without contrast enhancement yielded results comparable to those of CEUS in detecting segmental congestion after LDLT. Therefore, MFI may be considered a viable alternative to CEUS.
6.Comparison of micro-flow imaging and contrast-enhanced ultrasonography in assessing segmental congestion after right living donor liver transplantation
Taewon HAN ; Woo Kyoung JEONG ; Jaeseung SHIN ; Dong Ik CHA ; Kyowon GU ; Jinsoo RHU ; Jong Man KIM ; Gyu-Seong CHOI
Ultrasonography 2024;43(6):469-477
Purpose:
This study aimed to determine whether micro-flow imaging (MFI) offers diagnostic performance comparable to that of contrast-enhanced ultrasonography (CEUS) in detecting segmental congestion among patients undergoing living donor liver transplantation (LDLT).
Methods:
Data from 63 patients who underwent LDLT between May and December 2022 were retrospectively analyzed. MFI and CEUS data collected on the first postoperative day were quantified. Segmental congestion was assessed based on imaging findings and laboratory data, including liver enzymes and total bilirubin levels. The reference standard was a postoperative contrast-enhanced computed tomography scan performed within 2 weeks of surgery. Additionally, a subgroup analysis examined patients who underwent reconstruction of the middle hepatic vein territory.
Results:
The sensitivity and specificity of MFI were 73.9% and 67.5%, respectively. In comparison, CEUS demonstrated a sensitivity of 78.3% and a specificity of 75.0%. These findings suggest comparable diagnostic performance, with no significant differences in sensitivity (P=0.655) or specificity (P=0.257) between the two modalities. Additionally, early postoperative laboratory values did not show significant differences between patients with and without congestion. The subgroup analysis also indicated similar diagnostic performance between MFI and CEUS.
Conclusion
MFI without contrast enhancement yielded results comparable to those of CEUS in detecting segmental congestion after LDLT. Therefore, MFI may be considered a viable alternative to CEUS.
7.Indirect Method for Estimation of Reference Intervals of Inflammatory Markers
Taewon KANG ; Jeaeun YOO ; Dong Wook JEKARL ; Hyojin CHAE ; Myungshin KIM ; Yeon-Joon PARK ; Eun-Jee OH ; Yonggoo KIM
Annals of Laboratory Medicine 2023;43(1):55-63
Background:
The direct method for reference interval (RI) estimating is limited due to the requirement of resources, difficulties in defining a non-diseased population, or ethical problems in obtaining samples. We estimated the RI for inflammatory biomarkers using an indirect method (RII).
Methods:
C-reactive protein (CRP), erythrocyte sedimentation rate (ESR) and presepsin (PSEP) data of patients visiting a single hospital were retrieved from April 2009 to April 2021. Right-skewed data were transformed using the Box-Cox transformation method. A mixed population of non-diseased and diseased distributions was assumed, followed by latent profile analysis for the two classes. The intersection point of the distribution curve was estimated as the RI. The influence of measurement size was evaluated as the ratio of abnormal values and adjustment (n×bandwidth) of the distribution curve.
Results:
The RIs estimated by the proposed RII method (existing method) were as follows: CRP, 0–4.1 (0–4.7) mg/L; ESR, 0–10.2 (0–15) mm/hr and PSEP, 0–411 (0–300) pg/mL. Measurement sizes ≥2,500 showed stable results. An abnormal-to-normal value ratio of 0.5 showed the most accurate result for CRP. Adjustment values ≤5 or >5 were applicable for a measurement size <25,000 or ≥25,000, respectively.
Conclusions
The proposed RII method could provide additional information for RI verification or estimation with some limitations.
8.An Autoimmune Encephalitis Case Associated with Pembrolizumab Use
Jung Yon YUM ; Joonho KIM ; Taewon KIM ; Woo Hyun PARK ; Min Kyung CHU
Journal of the Korean Neurological Association 2022;40(2):137-140
Immune checkpoint inhibitors may be associated with various adverse events, including encephalitis. Here, we report a case of encephalopathy associated with pembrolizumab therapy. A 60-year-old male diagnosed with cholangiocarcinoma with peritoneal seeding presented altered mentality and cognitive function after using pembrolizumab. Electroencephalogram showed mild diffuse cerebral dysfunction. Cerebrospinal fluid (CSF) study showed no evidence of infection or autoimmune disease and no paraneoplastic antibody was detected from CSF and serum. After high-dose methylprednisolone intravenous infusion, patient’s mentality was fully recovered.

Result Analysis
Print
Save
E-mail