1.Breast cancer implant reconstructive surgery and radiotherapy: a retrospective analysis of medical records
Ji Young YUN ; Ki Jung AHN ; Hyunjung KIM ; Hee Yeon KIM ; Tae Hyun KIM ; Kyung Do BYUN ; Ji Sun PARK ; Yunseon CHOI
Annals of Surgical Treatment and Research 2025;108(5):295-301
Purpose:
This study aimed to analyze whether the occurrence of complications increases if radiotherapy (RT) is administered after breast reconstructive surgery using implants.
Methods:
This retrospective study included 80 patients who underwent breast reconstruction using implants, of which 16 (20.0%) underwent RT. Most patients underwent conventional fractionated RT (n = 13), and hypofractionated RT was performed in 3 patients. Most patients (n = 51, 63.8%) underwent delayed reconstruction, which involved implant replacement after tissue expander insertion. Only 29 patients (36.3%) underwent immediate reconstruction simultaneously with breast cancer surgery.
Results:
The median postoperative follow-up was 39.9 months (range, 8.7–120.3 months). Complications occurred in 18 (22.5%); infectionecrosis (n = 8), leakage/rupture (n = 8), and capsular contracture (n = 2). Infectionecrosis is common in patients undergoing RT. Complications occurred in 4 patients (25.0%) who received RT and 14 (21.9%) who did not receive RT, and complications did not significantly increase with RT (P = 0.511). There was no overall difference in complications between the immediate (4 of 29) and delayed (14 of 51) reconstruction groups (P = 0.129). Nine patients underwent reoperation because of complications; 3 (18.8%) received RT and 6 (9.4%) did not receive RT. The reoperation rate did not increase significantly with RT (P = 0.254). There were 3 cases of recurrence, and patients who received RT had no recurrence.
Conclusion
RT did not significantly increase the complication or reoperation rates if reconstructive surgery was performed using implants. Therefore, RT should be performed in patients at a high risk of recurrence.
2.Prospective Evaluation of Accelerated Brain MRI Using Deep Learning-Based Reconstruction: Simultaneous Application to 2D Spin-Echo and 3D Gradient-Echo Sequences
Kyu Sung CHOI ; Chanrim PARK ; Ji Ye LEE ; Kyung Hoon LEE ; Young Hun JEON ; Inpyeong HWANG ; Roh Eul YOO ; Tae Jin YUN ; Mi Ji LEE ; Keun-Hwa JUNG ; Koung Mi KANG
Korean Journal of Radiology 2025;26(1):54-64
Objective:
To prospectively evaluate the effect of accelerated deep learning-based reconstruction (Accel-DL) on improving brain magnetic resonance imaging (MRI) quality and reducing scan time compared to that in conventional MRI.
Materials and Methods:
This study included 150 participants (51 male; mean age 57.3 ± 16.2 years). Each group of 50 participants was scanned using one of three 3T scanners from three different vendors. Conventional and Accel-DL MRI images were obtained from each participant and compared using 2D T1- and T2-weighted and 3D gradient-echo sequences. Accel-DL acquisition was achieved using optimized scan parameters to reduce the scan time, with the acquired images reconstructed using U-Net-based software to transform low-quality, undersampled k-space data into high-quality images. The scan times of Accel-DL and conventional MRI methods were compared. Four neuroradiologists assessed the overall image quality, structural delineation, and artifacts using Likert scale (5- and 3-point scales). Inter-reader agreement was assessed using Fleiss’ kappa coefficient. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated, and volumetric quantification of regional structures and white matter hyperintensities (WMHs) was performed.
Results:
Accel-DL showed a mean scan time reduction of 39.4% (range, 24.2%–51.3%). Accel-DL improved overall image quality (3.78 ± 0.71 vs. 3.36 ± 0.61, P < 0.001), structure delineation (2.47 ± 0.61 vs. 2.35 ± 0.62, P < 0.001), and artifacts (3.73 ± 0.72 vs. 3.71 ± 0.69, P = 0.016). Inter-reader agreement was fair to substantial (κ = 0.34–0.50). SNR and CNR increased in Accel-DL (82.0 ± 23.1 vs. 31.4 ± 10.8, P = 0.02; 12.4 ± 4.1 vs. 4.4 ± 11.2, P = 0.02). Bland-Altman plots revealed no significant differences in the volumetric measurements of 98.2% of the relevant regions, except in the deep gray matter, including the thalamus. Five of the six lesion categories showed no significant differences in WMH segmentation, except for leukocortical lesions (r = 0.64 ± 0.29).
Conclusion
Accel-DL substantially reduced the scan time and improved the quality of brain MRI in both spin-echo and gradientecho sequences without compromising volumetry, including lesion quantification.
3.Brain Injury and Short-Term Neurodevelopmental Outcomes in Neonates Treated with Respiratory Extracorporeal Membrane Oxygenation: A Single-Center Experience
Keon Hee SEOL ; Byong Sop LEE ; Kyusang YOO ; Joo Hyung ROH ; Jeong Min LEE ; Jung Il KWAK ; Tae-Gyeong KIM ; Juhee PARK ; Ha Na LEE ; Chae Young KIM ; Soo Hyun KIM ; Ji Yoon JEONG ; Euiseok JUNG
Neonatal Medicine 2025;32(1):39-48
Purpose:
This study aimed to characterize the clinical patterns and severity of brain injury in neonates who survived extracorporeal membrane oxygenation (ECMO) therapy for acute respiratory failure during the neonatal period, to evaluate their short-term neurodevelopmental outcomes, and to identify the factors associated with these outcomes.
Methods:
We retrospectively reviewed the medical records of neonates who survived ECMO between 2018 and 2024. Based on brain magnetic resonance imaging (MRI) findings, the patients were classified into two groups: no/mild and moderate/severe brain injury. Neurodevelopmental outcomes were assessed at 12–40 months of age using the Bayley Scale of Infant Development II/III and/or the Korean Developmental Screening Test.
Results:
Among the 19 neonates included in the study, 18 (94.7%) showed varying degrees of brain injury on MRI (mild: 12, moderate: 1, severe: 5). Neonates with moderate/severe brain injury had significantly longer durations of ECMO support and extended durations of mechanical ventilation and were more likely to receive continuous renal replacement therapy than those with no or mild injury. Developmental delay was identified in 36.8% of survivors and was significantly associated with prolonged mechanical ventilation, longer neonatal intensive care unit stays, and a higher incidence of seizures.
Conclusion
Brain injury is frequently observed on MRI in neonates treated with ECMO. However, its direct association with adverse neurodevelopmental outcomes is not definitive. Since MRI findings alone cannot predict developmental outcomes, clinical and environmental factors should be integrated into prognostic assessments.
4.Permanent Congenital Hypothyroidism in Very Low Birth Weight Infants: A Single Center’s Experience
Joo Hyung ROH ; Tae-Gyeong KIM ; Keon Hee SEOL ; Chae Young KIM ; Soo Hyun KIM ; Ji Yoon JEONG ; Ja Hye KIM ; Euiseok JUNG ; Jin-Ho CHOI ; Byong Sop LEE
Neonatal Medicine 2025;32(1):30-38
Purpose:
Congenital hypothyroidism (CH) is a major preventable cause of intellectual disability, particularly in very low birth weight (VLBW) infants, who are at increased risk due to hypothalamic-pituitary-thyroid axis immaturity. Early differentiation between transient CH (TCH) and permanent CH (PCH) is crucial to optimize L-thyroxine (LT4) treatment duration. This study aimed to determine the incidence of PCH among Korean VLBW infants and to identify clinical factors that may aid in distinguishing TCH from PCH.
Methods:
This retrospective cohort study included VLBW infants diagnosed with CH and treated with LT4 at a single tertiary neonatal intensive care unit between 2011 and 2020. Infants requiring LT4 beyond 3 years were classified as PCH, while those who discontinued earlier were considered TCH. Clinical characteristics, neonatal morbidities, and thyroid-related parameters were compared between the groups.
Results:
Among 1,292 VLBW infants, 122 (9.4%) were diagnosed with CH. After excluding deaths and those lost to follow-up, 73 infants were included in the final analysis (TCH, n=50; PCH, n=23). The PCH group had a significantly higher mean gestational age and greater LT4 requirements at both 12 and 36 months of age. Major anomalies were more frequently observed in PCH infants, including congenital heart defects. In multivariate analysis, higher gestational age, the presence of major anomalies, screening thyroid-stimulating hormone (TSH) >10 μIU/mL, and higher LT4 dose at 36 months were significantly associated with PCH.
Conclusion
The incidence of PCH in Korean VLBW infants was relatively higher than that reported in previous studies studies. Screening TSH level and LT4 dose requirements may support individualized follow-up and help distinguish PCH from TCH.
5.Triiodothyronine Is Associated with Incidence/Resolution of Steatotic Liver Disease: Longitudinal Study in Euthyroid Korean
Hye In KIM ; Jun Young KIM ; Jung Hwan CHO ; Ji Min HAN ; Sunghwan SUH ; Ji Cheol BAE ; Tae Hyuk KIM ; Sun Wook KIM ; Jong Ryeal HAHM ; Jae Hoon CHUNG
Endocrinology and Metabolism 2025;40(1):135-145
Background:
The positive relationship between triiodothyronine (T3) and steatotic liver disease (SLD) demonstrated only in crosssectional study. We aimed to evaluated whether total T3 (TT3) is associated with the development/resolution of SLD in longitudinal design.
Methods:
This retrospective, longitudinal, population-based cohort study included 1,665 South Korean euthyroid adults with ≥4 thyroid function test. We explored the impact of mean TT3 during follow-up on development/resolution of either SLD (diagnosed by ultrasound) or modified metabolic dysfunction-associated steatotic liver disease (MASLD) using Cox proportional hazards regression models.
Results:
During about median 5 years follow-up, 807/1,216 (66.3%) participants among participants without SLD at baseline developed SLD, and 253/318 (79.5%) participants among participants with SLD at baseline SLD resolved fatty liver. Mean TT3 rather than thyroid stimulating hormone or mean free thyroxine was significantly related with development (adjusted hazard ratio [HR], 1.01; 95% confidence interval [CI], 1.00 to 1.02; P=0.002) and resolution (adjusted HR, 0.97; 95% CI, 0.96 to 0.99; P=0.005) of SLD. Compared with low mean TT3 group, high mean TT3 group was positively associated with development of SLD (adjusted HR, 1.20; 95% CI, 1.05 to 1.38; P=0.008) and inversely associated with resolution of SLD (adjusted HR, 0.66; 95% CI, 0.51 to 0.85; P=0.001). The statistical significance remained for development (adjusted HR, 1.29; 95% CI, 1.10 to 1.51; P=0.001) and resolution (adjusted HR, 0.71; 95% CI, 0.54 to 0.94; P=0.018) of modified MASLD.
Conclusion
In Korean euthyroid adults, TT3 level was associated with development and resolution of either SLD or modified MASLD.
6.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
7.Measuring Medical Waste from Gastrointestinal Endoscopies in South Korea to Estimate Their Carbon Footprint
Da Hyun JUNG ; Hyun Jung LEE ; Tae Joo JEON ; Young Sin CHO ; Bo Ra KANG ; Nae Sun YOUN ; Jae Myung CHA
Gut and Liver 2025;19(1):43-49
Background/Aims:
Although gastrointestinal endoscopy (GIE) is a major contributor to the carbon footprint of national healthcare, the amount of medical waste generated by GIE procedures is not reported in South Korea. This study aimed to measure the amount of medical waste generated from GIE procedures in South Korea.
Methods:
We conducted a 5-day audit of medical waste generated during GIEs at seven hospitals. During the study period, medical waste in the endoscopy examination rooms was measured twice daily and documented as mass (kg). To calculate the mean mass of disposable waste generated during one esophagogastroduodenoscopy (EGD) and one colonoscopy, the mean mass of medical waste generated from seven examinations was calculated. The mean mass of medical waste generated during GIEs was calculated by dividing the total mass of medical waste generated by the number of GIE procedures.
Results:
Overall, 3,922 endoscopies were performed and 4,558 kg of waste was generated. The mean weight of medical waste generated per endoscopy was 1.34 kg. Each EGD and colonoscopy generated a mean of 0.24 kg and 0.43 kg of disposable waste, respectively. Applying the mean waste estimates from this study to annual GIE procedures performed in South Korea in 2022 showed that the total medical waste produced from GIE was 13,704,453 kg. In addition, the total masses of medical waste produced during EGD and colonoscopy procedures were 819,766 kg and 2,889,478 kg, respectively.
Conclusions
Our quantitative measurement showed that a large amount of medical waste is generated from GIE procedures. However, further research is warranted to reduce medical waste generated during GIE, which is an urgent unmet need.
8.Breast cancer implant reconstructive surgery and radiotherapy: a retrospective analysis of medical records
Ji Young YUN ; Ki Jung AHN ; Hyunjung KIM ; Hee Yeon KIM ; Tae Hyun KIM ; Kyung Do BYUN ; Ji Sun PARK ; Yunseon CHOI
Annals of Surgical Treatment and Research 2025;108(5):295-301
Purpose:
This study aimed to analyze whether the occurrence of complications increases if radiotherapy (RT) is administered after breast reconstructive surgery using implants.
Methods:
This retrospective study included 80 patients who underwent breast reconstruction using implants, of which 16 (20.0%) underwent RT. Most patients underwent conventional fractionated RT (n = 13), and hypofractionated RT was performed in 3 patients. Most patients (n = 51, 63.8%) underwent delayed reconstruction, which involved implant replacement after tissue expander insertion. Only 29 patients (36.3%) underwent immediate reconstruction simultaneously with breast cancer surgery.
Results:
The median postoperative follow-up was 39.9 months (range, 8.7–120.3 months). Complications occurred in 18 (22.5%); infectionecrosis (n = 8), leakage/rupture (n = 8), and capsular contracture (n = 2). Infectionecrosis is common in patients undergoing RT. Complications occurred in 4 patients (25.0%) who received RT and 14 (21.9%) who did not receive RT, and complications did not significantly increase with RT (P = 0.511). There was no overall difference in complications between the immediate (4 of 29) and delayed (14 of 51) reconstruction groups (P = 0.129). Nine patients underwent reoperation because of complications; 3 (18.8%) received RT and 6 (9.4%) did not receive RT. The reoperation rate did not increase significantly with RT (P = 0.254). There were 3 cases of recurrence, and patients who received RT had no recurrence.
Conclusion
RT did not significantly increase the complication or reoperation rates if reconstructive surgery was performed using implants. Therefore, RT should be performed in patients at a high risk of recurrence.
9.Stress Accelerates Depressive-Like Behavior through Increase of SPNS2 Expression in Tg2576 Mice
Seung Sik YOO ; Yuri KIM ; Dong Won LEE ; Hyeon Joo HAM ; Jung Ho PARK ; In Jun YEO ; Ju Young CHANG ; Jaesuk YUN ; Dong Ju SON ; Sang-Bae HAN ; Jin Tae HONG
Biomolecules & Therapeutics 2025;33(3):417-428
To investigate the relationship between depression and AD, water avoidance stress (WAS) was induced for 10 days in both Tg2576 mice and wild-type (WT) mice. After WAS, memory function and depressive-like behavior were investigated in Tg2576 mice. Tg2576 WAS mice exhibited more depressive-like behaviors than WT WAS and Tg2576 control (CON) mice. Strikingly, Tg2576 CON mice showed more depressive-like behaviors than WT mice. Moreover, corticosterone and phospho-glucocorticoid receptor (p-GR) levels were also higher in Tg2576 WAS mice in comparison to Tg2576 CON mice. Spinster homologue 2 (SPNS2) is a member of non-ATP-dependent transporter. The role of SPNS2 was widely known as a sphingosine-1-phosphate (S1P) transporter, which export intracellular S1P from cells. Using GEO database to analyze SPNS2 gene expression changes in patients with AD and depression, we show that SPNS2 gene expression correlates with AD and depression. Interestingly, Tg2576 WAS mice displayed significantly increased levels of SPNS2 w1hen compared to Tg2576 CON counterparts. SPNS2 levels were also higher in Tg2576 CON mice in comparison with WT CON mice. Remarkably, we found a decrease in S1P brain levels and an increase in S1P serum levels of Tg2576 WAS mice in comparison with Tg2576 CON mice. Accordingly, WAS induced group further decreased S1P levels in the brains. However, the level in the serum further increased in comparison with non-induced group. Therefore, these results suggest that AD and depression could be associated, and that Tg2576 transgenic mice are more susceptible to stress-induced depression through the release of S1P by SPNS2 up-regulation.
10.Target-Enhanced Whole-Genome Sequencing Shows Clinical Validity Equivalent to Commercially Available Targeted Oncology Panel
Sangmoon LEE ; Jin ROH ; Jun Sung PARK ; Islam Oguz TUNCAY ; Wonchul LEE ; Jung-Ah KIM ; Brian Baek-Lok OH ; Jong-Yeon SHIN ; Jeong Seok LEE ; Young Seok JU ; Ryul KIM ; Seongyeol PARK ; Jaemo KOO ; Hansol PARK ; Joonoh LIM ; Erin CONNOLLY-STRONG ; Tae-Hwan KIM ; Yong Won CHOI ; Mi Sun AHN ; Hyun Woo LEE ; Seokhwi KIM ; Jang-Hee KIM ; Minsuk KWON
Cancer Research and Treatment 2025;57(2):350-361
Purpose:
Cancer poses a significant global health challenge, demanding precise genomic testing for individualized treatment strategies. Targeted-panel sequencing (TPS) has improved personalized oncology but often lacks comprehensive coverage of crucial cancer alterations. Whole-genome sequencing (WGS) addresses this gap, offering extensive genomic testing. This study demonstrates the medical potential of WGS.
Materials and Methods:
This study evaluates target-enhanced WGS (TE-WGS), a clinical-grade WGS method sequencing both cancer and matched normal tissues. Forty-nine patients with various solid cancer types underwent both TE-WGS and TruSight Oncology 500 (TSO500), one of the mainstream TPS approaches.
Results:
TE-WGS detected all variants reported by TSO500 (100%, 498/498). A high correlation in variant allele fractions was observed between TE-WGS and TSO500 (r=0.978). Notably, 223 variants (44.8%) within the common set were discerned exclusively by TE-WGS in peripheral blood, suggesting their germline origin. Conversely, the remaining subset of 275 variants (55.2%) were not detected in peripheral blood using the TE-WGS, signifying them as bona fide somatic variants. Further, TE-WGS provided accurate copy number profiles, fusion genes, microsatellite instability, and homologous recombination deficiency scores, which were essential for clinical decision-making.
Conclusion
TE-WGS is a comprehensive approach in personalized oncology, matching TSO500’s key biomarker detection capabilities. It uniquely identifies germline variants and genomic instability markers, offering additional clinical actions. Its adaptability and cost-effectiveness underscore its clinical utility, making TE-WGS a valuable tool in personalized cancer treatment.

Result Analysis
Print
Save
E-mail