1.Rules on acupoint selection and treatment for epigastric pain based on the data mining of ancient acupuncture-moxibustion prescriptions.
Suyun LI ; Jianing WANG ; Zhongnan LI ; Qingyang CHAI ; Xianghong JING
Chinese Acupuncture & Moxibustion 2025;45(2):253-261
The rules of acupoint selection and treatment were identified and discovered from the collected ancient acupuncture-moxibustion prescriptions recorded the earliest for epigastric pain. The database of ancient acupuncture-moxibustion prescriptions for epigastric pain was set up using Excel2016 software. After the disease term, etiology, pathogenesis, symptoms and acupoints were normalized, the underlying multi-dimensional correlation among the elements of acupuncture-moxibustion was explored, using the frequency statistics and the association rule of Apriori algorithm. In the ancient time, in treatment with acupuncture-moxibustion therapy for epigastric pain, the acupoints of the high use frequency were sequenced as Zhongwan (CV12), Shangwan (CV13), Zusanli (ST36), Neiguan (PC6), Gongsun (SP4), Pishu (BL20) and Weishu (BL21). The common combinations of acupoints included the pairs of back-shu points, the combination of back-shu points and front-mu points, the combination of front-mu points and yuan-source points and the combination of back-shu points and the lower he-sea points. The highly involved acupoints were those from the conception vessel, pericardium meridian, spleen meridian, stomach meridian and bladder meridian; and they were commonly distributed on the abdomen, the yin parts of the foot and the arm, the yang part of the leg and on the back. Regarding the etiologies such as parasites, food retention, masses, qi stagnation and stomach cold, Zhongwan (CV12) and Shangwan (CV13) were coordinated; and Sanyinjiao (SP6) and Daling (PC7) were highly associated with masses. Besides cold injury, parasites and masses, for the epigastric pain caused by other factors of etiology (qi stagnation, stomach cold and food retention), moxibustion therapy was greatly applicable. For epigastric pain combined with qi reversion in the lower abdominal region, Qichong (ST30), Sanyinjiao (SP6), Tianshu (ST25) and Zusanli (ST36) must be selected. Dadu (SP2) and Taibai (SP3) must be used if the distention in the chest and abdomen accompanied; and Zhongzhu (TE3) be used if back pain involved. Zusanli (ST36) was commonly selected for hiccups. For the other accompanied symptoms, Zhongwan (CV12) was used, which is consistent with the acupoint selection of main symptoms. On the trunk, moxibustion was generally used at Weishu (BL21), Pishu (BL20), Geshu (BL17), Zhongwan (CV12), Juque (CV14) and Qihai (CV6), except Shangwan (CV13). Among the acupoints below the elbows and knees, moxibustion was commonly applicable at Zusanli (ST36), and acupuncture was often used at Gongsun (SP4) and Daling (PC7).
Acupuncture Points
;
Humans
;
Moxibustion/history*
;
History, Ancient
;
Acupuncture Therapy/history*
;
Data Mining
;
Abdominal Pain/history*
2.Repeatability of wavefront aberration measured by adaptive optics visual simulator and agreement of OPD-Scan Ⅲ
Yan WANG ; Xuan LIAO ; Changjun LAN ; Biao LI ; Zhuang MIAO ; Qingqing TAN ; Suyun QIN ; Huan HUANG
International Eye Science 2024;24(5):810-815
AIM: To assess the repeatability and agreement of higher-order aberration obtained by adaptive optics visual simulator(VAO)compared with OPD-Scan Ⅲ.METHODS: A cross-sectional study was conducted from August to September 2023, including a total of 204 patients(204 eyes)with myopia whose right eyes were measured. The examinations were performed by the same skilled examiner using both devices separately. The VAO device was used to measure higher order aberrations of orders 3 to 6 at a pupil diameter of 4.5 mm, while both the VAO and OPD-Scan Ⅲ devices were utilized to measure total higher-order aberration(tHOA), spherical aberration(SA), coma aberration(Coma), and trefoil aberration(Trefoil)of the entire eye at pupil diameters ranging from 3 to 6 mm. Furthermore, the repeatability of whole eye aberration measurements obtained with the VAO device was evaluated and the agreement of the two devices was assessed.RESULTS: The whole-eye higher-order aberrations measured by VAO demonstrated excellent repeatability(0.767≤ICC≤0.941, Sw<0.01 μm, TRT<0.1 μm). There was no statistically significant difference in Coma measured by VAO or OPD-Scan Ⅲ for pupil diameters ranging from 4 to 6 mm(P>0.05), while a statistically significant difference was observed in whole-eye tHOA of other pupil diameters(all P<0.05). The agreement of aberration measurements for each order between VAO and OPD-Scan Ⅲ for 3 mm pupil diameters, SA at 4 and 5 mm pupil diameter and Coma at 4 mm pupil diameter showed a 95% limit of agreement(LoA)<0.1, indicating good agreement; however, poor agreement was found for the remaining aberration measurements at different pupil diameters, with a 95%LoA>0.1, and there were significant differences in higher-order aberrations measured by two devices under a pupil diameter of 3 mm(r=0.218-0.317, P<0.01), 4 mm(r=0.406-0.672, P<0.01), 5 mm(r=0.538-0.839, P<0.01 and r=0.030-0.109, P>0.01)and 6 mm(r=0.369-0.766, P<0.01).CONCLUSION: The VAO demonstrates favorable repeatability when assessing whole-eye higher order aberration under pupil diameters of 3-6 mm. However, there is inadequate agreement and interchangeability in whole-eye higher order aberration at 3-6 mm pupil diameter between VAO and OPD-Scan Ⅲ for clinical purposes.
3.Current status of research on the diagnosis and specific treatment of glycogen storage disease type Ⅱ
Pan WANG ; Yingchao LIU ; Suyun QIAN
Chinese Journal of Applied Clinical Pediatrics 2024;39(1):65-68
Glycogen storage disease type Ⅱ (GSDⅡ) is a rare autosomal recessive disorder.Infant onset of GSDⅡ usually accompanies progressive cardiac hypertrophy and muscle weakness, and eventually dies of cardiopulmonary failure.GSDⅡ is mainly screened and diagnosed by enzymatic and genetic tests.Enzyme replacement therapy (ERT) is the only currently approved treatment of GSDⅡ, which can effectively improve the function of the affected organs and the survival.Gene therapy and substrate reduction therapy for GSDⅡ are also undergoing basic or clinical research.This review summarizes the current research status of the diagnosis and treatment of GSDⅡ at home and abroad, focusing on the influencing factors for the efficacy of specific treatment (especially ERT), dosing regimen, and ways to improve the efficacy.
4.Evaluation of optical performance of aspherical intraocular lens in vitro by optical bench
Lixuan XIE ; Xuan LIAO ; Changjun LAN ; Qingqing TAN ; Ruolin PAN ; Yuling TANG ; Suyun QIN ; Yan WANG
Chinese Journal of Experimental Ophthalmology 2024;42(3):240-247
Objective:To evaluate the optical performance of two aspheric intraocular lenses (IOL) AcrySof IQ SN60WF and Proming A1-UV with identical negative spherical aberration values, using the optical bench OptiSpheric IOL R&D through an in vitro study. Methods:The optical performance of + 20.0 D blue-light filtering SN60WF and monofocal high-order aspheric non blue-light filtering A1-UV IOL was evaluated through cornea models with the spherical aberration of 0 μm (ISO-1) and + 0.28 μm (ISO-2) under apertures of 3.0 mm and 4.5 mm via the optical bench OptiSpheric IOL R&D.The modulation transfer function (MTF) and USAF 1951 resolution test chart were employed to measure the IOL with centering, decentration of 0.3, 0.5, 0.7, 0.9 and 1.1 mm, as well as tilt of 3°, 5°, 7°, 9° and 11°.The spectral transmittance of IOL was measured with the UV-3300 UV-VIS spectrophotometer.Results:Compared with the A1-UV IOL, the spectral transmittance of SN60WF for blue light with wavelengths of 400-500 nm was significantly reduced, which effectively reduced the passage of blue light.At an aperture of 3.0 mm, the MTF values at 100 lp/mm spatial frequency for the centered SN60WF and A1-UV were 0.576 and 0.598 under ISO-1 corneal measurement conditions, 0.564 and 0.563 under ISO-2 conditions.At an aperture of 4.5 mm, the MTF values were 0.238 and 0.404 under ISO-1 corneal measurement conditions, and 0.438 and 0.339 under ISO-2 conditions.The MTF values of A1-UV and SN60WF at 3.0 mm aperture and 100 lp/mm spatial frequency under ISO-1 corneal measurement conditions were larger than those under ISO-2 corneal measurement conditions.Under ISO-1 corneal measurement conditions with a 3.0 mm aperture, A1-UV had a better optical quality compared to SN60WF, whereas under ISO-2 corneal measurement conditions, the optical quality of both IOLs was similar.Under the 3.0 mm aperture, the MTF values of SN60WF and A1-UV at a decentration of 0.3 mm and 100 lp/mm spatial frequency were 0.414 and 0.571 under ISO-1 corneal measurement conditions, 0.438 and 0.512 under ISO-2 corneal measurement conditions, respectively.The MTF values of SN60WF and A1-UV at a tilt of 3° were 0.522 and 0.597 under ISO-1 corneal measurement conditions, and 0.532 and 0.531 under ISO-2 corneal measurement conditions.The MTF values and USAF resolution test chart of A1-UV had no significant change between the two corneal measurement conditions.When subjected to equal degrees of decentration or tilting, except for the ISO-1 corneal measurement conditions at a 4.5 mm aperture, the MTF values of A1-UV showed a gradual decline across various spatial frequencies compared to SN60WF.With the increase in aperture size, the impact of IOL decentration or tilting on MTF values and USAF 1951 resolution test chart became more notable for A1-UV relative to SN60WF.Conclusions:The SN60WF IOL effectively filters blue light within the wavelength range of 400-500 nm.However, when both IOL experience decentration greater than 0.3 mm or tilting beyond 3°, the optical quality of the IOL will decline.A1-UV has a distinct advantage over SN60WF in terms of resistance to both decentration and tilting-induced optical performance degradation in vitro.
5.Development Status and Quality Evaluation on Clinical Practice Guidelines for the Treatment of Dominant Diseases with Chinese Patent Medicines
Jiang YANG ; Hulei ZHAO ; Yaolong CHEN ; Jianxin WANG ; Yang XIE ; Suyun LI ; Jiansheng LI ; Minghang WANG
Journal of Traditional Chinese Medicine 2024;65(6):636-644
ObjectiveTo analyze the development status and quality of clinical practice guidelines for the treatment of dominant diseases with Chinese patent medicines (CPMs). MethodsDatabases were searched from Jan. 2019 to Dec.2023 to collect the published clinical practice guidelines of CPMs for the treatment of dominant diseases. The information about the title, the participants, clinical problems, outcomes, evidence grade, recommendations, and recommendation strength in the included clinical practice guidelines were collected, for which the development status was analyzed, and the quality was evaluated with the Scientific, Transparent and Applicable Rankings (STAR) tool for clinical practice guidelines. ResultsTotally, 34 guidelines were included, involving 273 kinds of CPMs. One to ten (with the medium five) clinical problems were proposed from 29 clinical practice guidelines respectively. All the guidelines divided the evidence into four grades according to Grade of Recommendation Assessment, Deve-lopement an Evaluation. And 28 guidelines had five levels of recommendation strength. A total of 344 recommendations were extracted, including 86 strong-recommendations, 191 weak-recommendations (including 36 weak recommendations only based on expert consensus) and 67 recommendations with unclear recommendation strength. All guidelines had high scores in the three areas of “clinical questions (94.20%)”, “evidence (91.45%)” and “recommendations (89.06%)”, while the scores in the three areas of “registry (22.06%)”, “protocol (19.00%)” and “accessibility (31.51%)” were low. The STAR recommended stars of 8 guidelines were 5.0~4.0 stars, while that of 18 guidelines were 3.5~2.5 stars, and 8 guidelines were 2.0~1.0 stars. The three guidelines with the highest recommended stars were depressive disorder, community-acquired pneumonia, and influenza in adult. ConclusionThere is a certain gap in the quality of the published clinical practice guidelines of CPMs, and the quality of the guidelines could be further improved in registry, protocols, funds, and accessibility.
6.Optimization of 18F-FDG PET/CT semi-quantitative diagnostic model for children with autoimmune encephalitis with epilepsy and negative MRI
Ziyuan LI ; Jing WU ; Shuqi WU ; Mingming CAO ; Suyun CHEN ; Ling LI ; Hui WANG ; Yafu YIN
Chinese Journal of Nuclear Medicine and Molecular Imaging 2024;44(4):213-219
Objective:To investigate the value of 18F-FDG PET/CT imaging in the diagnosis of suspected autoimmune encephalitis (AE) in children with epilepsy and negative MRI. Methods:From May 2019 to August 2022, 94 suspected AE children (49 males, 45 females; age 1-15 years) with epilepsy and negative MRI who underwent brain 18F-FDG PET/CT imaging at Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine were retrospectively analyzed. All patients were divided into AE and non-AE groups based on clinical final diagnosis. The effectiveness of visual diagnosis was evaluated. The cortical lesion extent score (S), and SUV max, SUV mean and minimum of SUV (SUV min) of cortical lesions (L), basal ganglia (B) and thalamus (T) were measured and SUV ratios (SUVR) of L/B or L/T were obtained. Independent-sample t test or Mann-Whitney U test was used to analyze data. Binary logistic regression analysis was used to screen the diagnostic factors of AE, and a diagnostic model was established. The diagnostic efficiency was evaluated by ROC curve analysis and Delong test. Results:There were 53 cases in AE group and 41 cases in non-AE group. Based on visual analysis, the sensitivity, specificity and accuracy of 18F-FDG PET/CT for AE were 100%(53/53), 43.9%(18/41) and 75.5%(71/94), respectively. Differences of LSUV max, LSUV mean, LSUV min, L/BSUVR max, L/BSUVR mean, L/BSUVR min, L/TSUVR max, L/TSUVR mean, L/TSUVR min and S between AE and non-AE groups were statistically significant ( z=-6.74, t values: from -8.51 to -3.97, all P<0.001). ROC curve analysis showed that the AUC of L/BSUVR max was the highest (0.914) among visual analysis and semi-quantitative parameters. Logistic regression analysis showed that S (odds ratio ( OR)=11.40, 95% CI: 2.18-59.52, P=0.004), L/BSUVR max( OR=13.19, 95% CI: 2.11-82.51, P=0.006) and L/TSUVR max( OR=9.66, 95% CI: 1.57-59.55, P=0.015) were independent diagnostic factors for AE. Regression model was established: P=1/(1+ e - x), x=2.433×S+ 2.580×L/BSUVR max+ 2.267×L/TSUVR max-3.802. The AUC of this model was 0.948, with the sensitivity, specificity and accuracy of 98.1%(52/53), 90.2%(37/41) and 94.7%(89/94), respectively. The diagnostic efficacy of the optimized scoring system was consistent with the pre-optimization model, and were both superior to L/BSUVR max(both z=2.01, both P=0.040). Conclusion:The diagnostic model and scoring system based on the semi-quantitative analysis of 18F-FDG PET/CT have better diagnostic efficacy for AE and are superior to semi-quantitative parameters alone.
7.Construction of risk pre-control scheme for postoperative pulmonary infection in elderly patients with hip fracture
Xiaofeng LI ; Xiaoping ZHU ; Suyun WANG
Chinese Journal of Modern Nursing 2024;30(6):718-726
Objective:To build a risk pre-control scheme for postoperative pulmonary infection in elderly patients with hip fracture based on the evidence-based evidence, so as to provide reference for clinical practice.Methods:From March 2021 to March 2022, a draft pre-control plan for postoperative pulmonary infection risk in elderly patients with hip fracture was developed based on previously included evidence and clinical conditions. Using the expert meeting method, the preliminary draft plan was revised and improved, and the practical plan for pre-controlling the risk of postoperative pulmonary infection in elderly patients with hip fractures was ultimately determined.Results:The 105 pieces of evidence summarized in the previous study formed 31 review indicators, and the risk pre-control plan of pulmonary infection after hip fracture in the elderly was constructed, which included 11 perioperative risk factor assessment items and 35 perioperative risk pre-control measures.Conclusions:The risk pre-control scheme of postoperative pulmonary infection in elderly patients with hip fracture is scientific and feasible, which can provide a certain basis for optimizing clinical practice, reducing the incidence of postoperative pulmonary infection and promoting patient recovery.
8.Research progress on influencing factors and intervention program of sense of coherence in cancer patients
Suyun QUAN ; Laiyou LI ; Ziwen HE ; Yue LI ; Yurou WANG
Chinese Journal of Modern Nursing 2024;30(12):1676-1680
This article reviews the concept and current situation, assessment tools, influencing factors, intervention measures, shortcomings, and prospects of sense of coherence in cancer patients, so as to provide reference and direction for subsequent research on sense of coherence in cancer patients.
9.Research progress in the role of ferroptosis in sepsis-associated acute lung injury
Yanglin SHI ; Jianya YANG ; Qingqing CHANG ; Qianqian WANG ; Minghang WANG ; Suyun LI
Chinese Journal of Comparative Medicine 2024;34(6):127-134
Sepsis is defined as a life-threatening organ dysfunction caused by a dysregulated host response to infection with an extremely high mortality rate,and it is the main risk factor for acute lung injury(ALI).However,the pathophysiology and pathogenesis of sepsis-associated ALI are not fully understood,and effective drugs are extremely limited.Therefore,it is urgent that we explore the pathogenesis of sepsis-associated ALI and attempt to discover effective intervention measures to improve the prognosis of sepsis-associated ALI patients.In recent years,ferroptosis has been considered closely related to the pathological and physiological processes of sepsis-associated ALI,and inhibiting related cell ferroptosis can effectively slow down the occurrence and development of the disease.In this paper,therapeutic strategies targeting ferroptosis in related cells are reviewed to provide a reference for future research on ferroptosis in sepsis-associated ALI and provide a new perspective on potential treatments.
10.Clinical predictive value of 20-minute residual rate of diuretic renal scintigraphy in the timing of pyeloplasty
Xueli JI ; Jinyu GOU ; Suyun CHEN ; Hongliang FU ; Renjian ZOU ; Hui WANG
Journal of Shanghai Jiaotong University(Medical Science) 2024;44(7):899-906
Objective·To explore the predictive value of diuretic renal scintigraphy parameters such as 20-minute residual rate(R20)for pyeloplasty in children with congenital unilateral ureteropelvic junction obstruction(UPJO).Methods·The clinical data and diuretic renal scintigraphy results of 110 children with congenital unilateral UPJO who were first treated at the Department of Nuclear Medicine,Xinhua Hospital,Shanghai Jiao Tong University School of Medicine from August 2018 to August 2023 were retrospectively analyzed.The imaging results and the progress of hydronephrosis were followed up after the first diuretic renal scintigraphy.According to the outcome event of pyeloplasty due to the progression of hydronephrosis,the children were divided into operation group and non-operation group.Age,gender,side of hydronephrosis,and baseline diuretic renal scintigraphy parameters including blood perfusion rate(BPR),differential renal function(DRF),time to peak(Tmax),time to half(T1/2)and R20 were compared between the two groups.Logistic regression was used to analyze the effect of various parameters on the progression of hydronephrosis.The receiver operating characteristic(ROC)curve was used to analyze the predictive value of diuretic renal scintigraphy parameters for surgical intervention.Wilcoxon test was used to compare the examination parameters of two diuretic renal dynamic imaging.Results·During the follow-up,60 children underwent pyeloplasty after progression,and the other 50 children did not progress.The differences in DRF,Tmax,T1/2 and R20 between the two groups of children at baseline were statistically significant(all P<0.05).Univariate and multivariate Logistic regression analysis showed that only R20 was an independent predictor of pyeloplasty(OR=4.730,95%CI 1.009-1.178,P=0.030).R20 predicted pyeloplasty with a sensitivity of 88.3%,specificity of 56%,the area under the ROC curve of 0.758(95%CI 0.667-0.850,P=0.000),and the cut-off value of 90.08%.During the follow-up,38 children underwent the second diuretic renal scintigraphy,and the DRF was lower than before.The difference between the two DRFs was statistically significant(Z=-2.589,P=0.010),especially in children with R20≥90.08%(Z=-2.166,P=0.030).R20 in the non-operation group decreased significantly compared with the baseline(Z=-2.062,P=0.039).However,R20 in the operation group was higher than baseline,but the difference was not statistically significant(P>0.05).Conclusion·R20 plays an important role in the prediction of pyeloplasty in children with congenital unilateral UPJO.For children with R20≥90.08%,pyeloplasty should be performed as soon as possible to prevent further deterioration of renal function.

Result Analysis
Print
Save
E-mail