1.Effect of decentration and tilt on in vitro optical quality of intraocular lenses with different focus designs
Ruolin PAN ; Xuan LIAO ; Changjun LAN ; Lixuan XIE ; Qingqing TAN ; Suyun QIN ; Huan HUANG ; Yan WANG
Chinese Journal of Experimental Ophthalmology 2025;43(3):211-218
Objective:To observe the effect of different degrees of decentration and tilt on the optical quality of the intraocular lenses (IOLs) with different focus designs.Methods:The UV 3300 PC UV-visible spectrophotometer was employed to measure the spectral transmittance of the monofocal IOL CT ASPHINA 509M (509M), bifocal IOL AT LISA 809M (809M), and trifocal IOL AT LISA Tri 839MP (839MP) within Zeiss MICS platform with a refractive power of + 20 D. The modulation transfer function (MTF) values at a spatial frequency of 50 lp/mm along with MTF curves and United States Air Force (USAF) resolution test charts for each IOL at the focal point were measured at apertures of 3.0 mm and 4.5 mm using the in vitro optical quality testing system OptiSpheric IOL R&D under centered, decentered (0.3, 0.5, 0.7, 0.9 and 1.1 mm) and tilted (3°, 5°, 7°, 9° and 11°) conditions. Results:All three IOLs filtrated the ultraviolet (UV) spectrum below 400 nm.When each IOL was in the centered position, at the 3.0 mm aperture, the MTF values were 0.772 at the far focus of the monofocal IOL 509M, 0.467 and 0.282 at the far and near focus of the bifocal IOL 809M, and 0.416, 0.147, and 0.229 at the far, intermediate, and near focus of the trifocal IOL 839MP, respectively.Whereas at the 4.5 mm aperture, the monofocal IOL 509M MTF value at the far focus was 0.664, the bifocal IOL 809M MTF values at the far and near focus were 0.506 and 0.264, and the trifocal IOL 839MP MTF values at the far, intermediate, and near focus were 0.392, 0.107, and 0.210, respectively.Among the three centered IOLs, the 509M demonstrated the highest MTF value at the far focus, followed by the 809M and then the 839MP; at the near focus, the MTF value of the 809M surpassed that of the 839MP.For decentration and tilt, the difference in MTF values of the three IOLs at the far and near focus was consistent with the differences observed when they were centered.At the same degree of decentration and tilt, all three IOLs exhibited superior optical quality at the 3.0 mm aperture compared to the 4.5 mm aperture.The optical quality of all three IOLs exhibited an overall decline as decentration and tilt increased.All three IOLs demonstrated a decrease in optical quality at the decentration of 0.3 mm or the tilt of 5°.Conclusions:The IOLs within the Zeiss MICS platform design exhibits identical spectral transmittance and UV filtering properties.Among the three IOLs, when centered, the 509M, the 839MP, and the 809M exhibit superior optical quality at the far, intermediate, and near focal points, respectively.Under decentered and tilted conditions, the 509M and the 809M demonstrate better resistance against decentration and tilt, respectively, at both far and near focuses.Additionally, all three IOLs demonstrate better optical quality at smaller apertures, given equivalent degrees of decentration or tilt.However, the optical quality at each focal point of the three IOLs decreases compared to the centered position when subjected to a decentration of 0.3 mm or a tilt of 5°.
2.Effect of decentration and tilt on in vitro optical quality of intraocular lenses with different focus designs
Ruolin PAN ; Xuan LIAO ; Changjun LAN ; Lixuan XIE ; Qingqing TAN ; Suyun QIN ; Huan HUANG ; Yan WANG
Chinese Journal of Experimental Ophthalmology 2025;43(3):211-218
Objective:To observe the effect of different degrees of decentration and tilt on the optical quality of the intraocular lenses (IOLs) with different focus designs.Methods:The UV 3300 PC UV-visible spectrophotometer was employed to measure the spectral transmittance of the monofocal IOL CT ASPHINA 509M (509M), bifocal IOL AT LISA 809M (809M), and trifocal IOL AT LISA Tri 839MP (839MP) within Zeiss MICS platform with a refractive power of + 20 D. The modulation transfer function (MTF) values at a spatial frequency of 50 lp/mm along with MTF curves and United States Air Force (USAF) resolution test charts for each IOL at the focal point were measured at apertures of 3.0 mm and 4.5 mm using the in vitro optical quality testing system OptiSpheric IOL R&D under centered, decentered (0.3, 0.5, 0.7, 0.9 and 1.1 mm) and tilted (3°, 5°, 7°, 9° and 11°) conditions. Results:All three IOLs filtrated the ultraviolet (UV) spectrum below 400 nm.When each IOL was in the centered position, at the 3.0 mm aperture, the MTF values were 0.772 at the far focus of the monofocal IOL 509M, 0.467 and 0.282 at the far and near focus of the bifocal IOL 809M, and 0.416, 0.147, and 0.229 at the far, intermediate, and near focus of the trifocal IOL 839MP, respectively.Whereas at the 4.5 mm aperture, the monofocal IOL 509M MTF value at the far focus was 0.664, the bifocal IOL 809M MTF values at the far and near focus were 0.506 and 0.264, and the trifocal IOL 839MP MTF values at the far, intermediate, and near focus were 0.392, 0.107, and 0.210, respectively.Among the three centered IOLs, the 509M demonstrated the highest MTF value at the far focus, followed by the 809M and then the 839MP; at the near focus, the MTF value of the 809M surpassed that of the 839MP.For decentration and tilt, the difference in MTF values of the three IOLs at the far and near focus was consistent with the differences observed when they were centered.At the same degree of decentration and tilt, all three IOLs exhibited superior optical quality at the 3.0 mm aperture compared to the 4.5 mm aperture.The optical quality of all three IOLs exhibited an overall decline as decentration and tilt increased.All three IOLs demonstrated a decrease in optical quality at the decentration of 0.3 mm or the tilt of 5°.Conclusions:The IOLs within the Zeiss MICS platform design exhibits identical spectral transmittance and UV filtering properties.Among the three IOLs, when centered, the 509M, the 839MP, and the 809M exhibit superior optical quality at the far, intermediate, and near focal points, respectively.Under decentered and tilted conditions, the 509M and the 809M demonstrate better resistance against decentration and tilt, respectively, at both far and near focuses.Additionally, all three IOLs demonstrate better optical quality at smaller apertures, given equivalent degrees of decentration or tilt.However, the optical quality at each focal point of the three IOLs decreases compared to the centered position when subjected to a decentration of 0.3 mm or a tilt of 5°.
3.Guideline for the prevention of intraoperative acquired pressure injury in paraplegic patients with spinal cord injury (version 2025)
Aijun XU ; Shuixia LI ; Bo CHEN ; Mengyuan YE ; Lejiao LANG ; Ning NING ; Lin ZHANG ; Changqing LIU ; Zhonglan CHEN ; Weihu MA ; Weishi LI ; Xiaoning WANG ; Dongmei BIAN ; Jiancheng ZENG ; Xin WANG ; Yuan GAO ; Yaping CHEN ; Jiali CHEN ; Yun HAN ; Xiuting LI ; Yang ZHOU ; Xiaojing SU ; Qiong ZHANG ; Tianwen HUANG ; Ping ZHANG ; Hua LIN ; Xingling XIAO ; Ruifeng XU ; Fanghui DONG ; Bing HAN ; Luo FAN ; Yanling PEI ; Suyun LI ; Xiaoju TAN ; Rongchen GUO ; Yefang ZOU ; Xiaoyun HAN ; Junqin DING ; Yi WANG ; Shuhua DENG ; Jinli GUO ; Yinhua LIANG ; Yuan CEN ; Xiaoqin LIU ; Junru CHEN ; Haiyang YU ; Lunlan LI ; Ying REN ; Yunxia LI ; Jianli LU ; Ying YING ; Lan WEI ; Yin WANG ; Qinhong XU ; Yanqin ZHANG ; Yang LYU ; Shijun ZHANG ; Sui WENJIE ; Sanlian HU ; Shuhong YANG ; Guoqing LI ; Jingjing AN ; Baorong HE ; Leling FENG
Chinese Journal of Trauma 2025;41(6):530-541
Paraplegia caused by spinal cord injury is a serious neurological complication, for which surgery is currently the main treatment method. Due to different surgical approaches, patients are usually expected to maintain a passive prone position for a long time or switch between the supine and prone positions. Affected by multiple factors such as neurogenic sensory disorders, pathological changes in muscle tone and operative duration, the risk of intraoperative acquired pressure injury (IAPI) is significantly increased. Current clinical prevention strategies for IAPI in these patients predominantly focus on localized pressure relief during positioning, lacking systematic, standardized comprehensive prevention protocols or evidence-based guidelines. To address it, Department of Nursing, Orthopedics Branch, China International Exchange and Promotive Association for Medical and Health Care, Spinal Trauma Professional Committee, Orthopedics Branch, Chinese Medical Doctor Association, Nursing Group of Spine and Spinal Cord Professional Committee of Chinese Association of Rehabilitation Medicine organized experts in relevant fields to formulate Guideline for the prevention of intraoperative acquired pressure injury in paraplegic patients with spinal cord injury ( version 2025), based on evidence-based medical evidence and latest research results and clinical practice at home and abroad. Eleven recommendations were put forward from the aspects of preoperative risk assessment, intraoperative prevention strategies, postoperative handover and monitoring, and supportive mechanisms for IAPI prevention, aiming to standardize the prevention measures and management strategies of IAPI in paraplegic patients with spinal cord injury and accelerate the recovery of patients and improve the therapeutic effect.
4.Guideline for the prevention of intraoperative acquired pressure injury in paraplegic patients with spinal cord injury (version 2025)
Aijun XU ; Shuixia LI ; Bo CHEN ; Mengyuan YE ; Lejiao LANG ; Ning NING ; Lin ZHANG ; Changqing LIU ; Zhonglan CHEN ; Weihu MA ; Weishi LI ; Xiaoning WANG ; Dongmei BIAN ; Jiancheng ZENG ; Xin WANG ; Yuan GAO ; Yaping CHEN ; Jiali CHEN ; Yun HAN ; Xiuting LI ; Yang ZHOU ; Xiaojing SU ; Qiong ZHANG ; Tianwen HUANG ; Ping ZHANG ; Hua LIN ; Xingling XIAO ; Ruifeng XU ; Fanghui DONG ; Bing HAN ; Luo FAN ; Yanling PEI ; Suyun LI ; Xiaoju TAN ; Rongchen GUO ; Yefang ZOU ; Xiaoyun HAN ; Junqin DING ; Yi WANG ; Shuhua DENG ; Jinli GUO ; Yinhua LIANG ; Yuan CEN ; Xiaoqin LIU ; Junru CHEN ; Haiyang YU ; Lunlan LI ; Ying REN ; Yunxia LI ; Jianli LU ; Ying YING ; Lan WEI ; Yin WANG ; Qinhong XU ; Yanqin ZHANG ; Yang LYU ; Shijun ZHANG ; Sui WENJIE ; Sanlian HU ; Shuhong YANG ; Guoqing LI ; Jingjing AN ; Baorong HE ; Leling FENG
Chinese Journal of Trauma 2025;41(6):530-541
Paraplegia caused by spinal cord injury is a serious neurological complication, for which surgery is currently the main treatment method. Due to different surgical approaches, patients are usually expected to maintain a passive prone position for a long time or switch between the supine and prone positions. Affected by multiple factors such as neurogenic sensory disorders, pathological changes in muscle tone and operative duration, the risk of intraoperative acquired pressure injury (IAPI) is significantly increased. Current clinical prevention strategies for IAPI in these patients predominantly focus on localized pressure relief during positioning, lacking systematic, standardized comprehensive prevention protocols or evidence-based guidelines. To address it, Department of Nursing, Orthopedics Branch, China International Exchange and Promotive Association for Medical and Health Care, Spinal Trauma Professional Committee, Orthopedics Branch, Chinese Medical Doctor Association, Nursing Group of Spine and Spinal Cord Professional Committee of Chinese Association of Rehabilitation Medicine organized experts in relevant fields to formulate Guideline for the prevention of intraoperative acquired pressure injury in paraplegic patients with spinal cord injury ( version 2025), based on evidence-based medical evidence and latest research results and clinical practice at home and abroad. Eleven recommendations were put forward from the aspects of preoperative risk assessment, intraoperative prevention strategies, postoperative handover and monitoring, and supportive mechanisms for IAPI prevention, aiming to standardize the prevention measures and management strategies of IAPI in paraplegic patients with spinal cord injury and accelerate the recovery of patients and improve the therapeutic effect.
5.Repeatability of wavefront aberration measured by adaptive optics visual simulator and agreement of OPD-Scan Ⅲ
Yan WANG ; Xuan LIAO ; Changjun LAN ; Biao LI ; Zhuang MIAO ; Qingqing TAN ; Suyun QIN ; Huan HUANG
International Eye Science 2024;24(5):810-815
AIM: To assess the repeatability and agreement of higher-order aberration obtained by adaptive optics visual simulator(VAO)compared with OPD-Scan Ⅲ.METHODS: A cross-sectional study was conducted from August to September 2023, including a total of 204 patients(204 eyes)with myopia whose right eyes were measured. The examinations were performed by the same skilled examiner using both devices separately. The VAO device was used to measure higher order aberrations of orders 3 to 6 at a pupil diameter of 4.5 mm, while both the VAO and OPD-Scan Ⅲ devices were utilized to measure total higher-order aberration(tHOA), spherical aberration(SA), coma aberration(Coma), and trefoil aberration(Trefoil)of the entire eye at pupil diameters ranging from 3 to 6 mm. Furthermore, the repeatability of whole eye aberration measurements obtained with the VAO device was evaluated and the agreement of the two devices was assessed.RESULTS: The whole-eye higher-order aberrations measured by VAO demonstrated excellent repeatability(0.767≤ICC≤0.941, Sw<0.01 μm, TRT<0.1 μm). There was no statistically significant difference in Coma measured by VAO or OPD-Scan Ⅲ for pupil diameters ranging from 4 to 6 mm(P>0.05), while a statistically significant difference was observed in whole-eye tHOA of other pupil diameters(all P<0.05). The agreement of aberration measurements for each order between VAO and OPD-Scan Ⅲ for 3 mm pupil diameters, SA at 4 and 5 mm pupil diameter and Coma at 4 mm pupil diameter showed a 95% limit of agreement(LoA)<0.1, indicating good agreement; however, poor agreement was found for the remaining aberration measurements at different pupil diameters, with a 95%LoA>0.1, and there were significant differences in higher-order aberrations measured by two devices under a pupil diameter of 3 mm(r=0.218-0.317, P<0.01), 4 mm(r=0.406-0.672, P<0.01), 5 mm(r=0.538-0.839, P<0.01 and r=0.030-0.109, P>0.01)and 6 mm(r=0.369-0.766, P<0.01).CONCLUSION: The VAO demonstrates favorable repeatability when assessing whole-eye higher order aberration under pupil diameters of 3-6 mm. However, there is inadequate agreement and interchangeability in whole-eye higher order aberration at 3-6 mm pupil diameter between VAO and OPD-Scan Ⅲ for clinical purposes.
6.Evaluation of optical performance of aspherical intraocular lens in vitro by optical bench
Lixuan XIE ; Xuan LIAO ; Changjun LAN ; Qingqing TAN ; Ruolin PAN ; Yuling TANG ; Suyun QIN ; Yan WANG
Chinese Journal of Experimental Ophthalmology 2024;42(3):240-247
Objective:To evaluate the optical performance of two aspheric intraocular lenses (IOL) AcrySof IQ SN60WF and Proming A1-UV with identical negative spherical aberration values, using the optical bench OptiSpheric IOL R&D through an in vitro study. Methods:The optical performance of + 20.0 D blue-light filtering SN60WF and monofocal high-order aspheric non blue-light filtering A1-UV IOL was evaluated through cornea models with the spherical aberration of 0 μm (ISO-1) and + 0.28 μm (ISO-2) under apertures of 3.0 mm and 4.5 mm via the optical bench OptiSpheric IOL R&D.The modulation transfer function (MTF) and USAF 1951 resolution test chart were employed to measure the IOL with centering, decentration of 0.3, 0.5, 0.7, 0.9 and 1.1 mm, as well as tilt of 3°, 5°, 7°, 9° and 11°.The spectral transmittance of IOL was measured with the UV-3300 UV-VIS spectrophotometer.Results:Compared with the A1-UV IOL, the spectral transmittance of SN60WF for blue light with wavelengths of 400-500 nm was significantly reduced, which effectively reduced the passage of blue light.At an aperture of 3.0 mm, the MTF values at 100 lp/mm spatial frequency for the centered SN60WF and A1-UV were 0.576 and 0.598 under ISO-1 corneal measurement conditions, 0.564 and 0.563 under ISO-2 conditions.At an aperture of 4.5 mm, the MTF values were 0.238 and 0.404 under ISO-1 corneal measurement conditions, and 0.438 and 0.339 under ISO-2 conditions.The MTF values of A1-UV and SN60WF at 3.0 mm aperture and 100 lp/mm spatial frequency under ISO-1 corneal measurement conditions were larger than those under ISO-2 corneal measurement conditions.Under ISO-1 corneal measurement conditions with a 3.0 mm aperture, A1-UV had a better optical quality compared to SN60WF, whereas under ISO-2 corneal measurement conditions, the optical quality of both IOLs was similar.Under the 3.0 mm aperture, the MTF values of SN60WF and A1-UV at a decentration of 0.3 mm and 100 lp/mm spatial frequency were 0.414 and 0.571 under ISO-1 corneal measurement conditions, 0.438 and 0.512 under ISO-2 corneal measurement conditions, respectively.The MTF values of SN60WF and A1-UV at a tilt of 3° were 0.522 and 0.597 under ISO-1 corneal measurement conditions, and 0.532 and 0.531 under ISO-2 corneal measurement conditions.The MTF values and USAF resolution test chart of A1-UV had no significant change between the two corneal measurement conditions.When subjected to equal degrees of decentration or tilting, except for the ISO-1 corneal measurement conditions at a 4.5 mm aperture, the MTF values of A1-UV showed a gradual decline across various spatial frequencies compared to SN60WF.With the increase in aperture size, the impact of IOL decentration or tilting on MTF values and USAF 1951 resolution test chart became more notable for A1-UV relative to SN60WF.Conclusions:The SN60WF IOL effectively filters blue light within the wavelength range of 400-500 nm.However, when both IOL experience decentration greater than 0.3 mm or tilting beyond 3°, the optical quality of the IOL will decline.A1-UV has a distinct advantage over SN60WF in terms of resistance to both decentration and tilting-induced optical performance degradation in vitro.
7.Antiphospholipid and other autoantibodies in COVID-19 patients: A Singapore series.
Khai Pang LEONG ; Carol Yee Leng NG ; Bingwen Eugene FAN ; Chien Mei LOH ; Lok To WONG ; Valerie Hui Hian GOH ; Gwen Li Xuan TAN ; Chong Rui CHUA ; Janet Suyun TAN ; Samuel Shang Ming LEE ; Xin Rong LIM ; Teck Choon TAN
Annals of the Academy of Medicine, Singapore 2022;51(9):586-588
8.Effect of combined use of different dose of exmedetomidine and ultra-low dose naloxoneon postoperative hyperalgesia induced by remifentanil
Suyun TAN ; Shenghua XIAO ; Zhijun WANG ; Quanguo HAN ; Yonghong LIU ; Zhijian QIU ; Zhaokai LU
The Journal of Practical Medicine 2015;31(15):2486-2489
Obejective To explore the effect of combined use of dexmedetomidine and ultra-low dose naloxone on postoperative hyperalgesia induced by remifentanil. Method 80 ASA gradeⅠ-Ⅱ female patients who were scheduled to perform endoscopic sinus surgery (ESS) were randomly divided into four groups: purely remifentanil group (group R) and remifentanil plus different dosage dexmedetomidine and ultra-low dose naloxone group (group RDN1 ~ RDN3). Then the postoperative VAS on 30 min, 1 h, 2 h, 4 h, 8 h, 12 h and 24 h together with the firstpostoperative pain time , PCA press numbers , fentanyl usage and adverse reaction rate were recorded and evaluated. Results Average VAS of group R are higher than other groups in all 7 time points at the adjusted significant level of 0.0083, and group R > group RDN1 > group RDN2 > group RDN3, while differences between group RDN2 and RDN3 in all time points are not statistical significant.There is no difference between group RDN1 and group RDN2 inthe first postoperative pain time and the PCA press time at 1h after operation. Difference between group RDN2 and group RDN3 in the PCA press time at 24 h after operation was not significant, and the fentanyl usage of RDN groups are significantly less than group R. Conclusions Combined use of dexmedetomidine and ultra-low dose naloxone induced by remifentanil can improving patients′postoperative hyperalgesia , effect increase with the dose of dexmedetomidine increas , and the increasement is more sensitive in acute pain.
9.Impact of sulfentanyl on ropivacaine epidural block during abdominal panhysterectomy
Zhaokai LU ; Jianzhong HUANG ; Ziyi FU ; Quanguo HAN ; Yonghong LIU ; Zhijun WANG ; Suyun TAN
The Journal of Practical Medicine 2014;(6):956-958
Objective To explore the impact of sulfentanyl on sufentanil epidural block during abdominal panhysterectomy. Methods 90 patients scheduled for panhysterectomy were randomly divided into three groups. Tthe control group received epidural administration of 1% ropivacaine of 0.2 mL/kg after 2% idocaine of 3 mL , while the study group 1 received 10μg sufentanil and the study group 2 received 20μg sufentanil in addition to the medications used in the control group. The anesthetic effect, changes in vital signs, and incidence of adverse reactions were compared among the three groups. Results In group S1 and group S2, the onset of epidural anesthesia was faster , time to the highest plane of sensory blockade and time to degree 3 in the Bromag scores were faster , duration of sensory blockade was longer , and OAA/S score was better , as compared with group D , with significant statistical significances (P<0.01);and the effect was better in group S2 than in group S1. There was no difference among the three groups in adverse reactions. MAP , HR and SPO2 were lower in groups S1 and S2 than in group D during the procedure, with a statistical difference (P<0.05). Conclusions Proper dose of sufentanil plays a positive role in ropivacaine epidural block during panhysterectomy , not only increases the onset of anesthesia, but also makes the anesthestic effect better, and has higher safety It is worth popularizing clinically.
10.X-ray evaluation of intestinal malrotafion in adults
Zhiqing ZHAO ; Maohong YANG ; Chaoxuan XU ; Yongliang TAN ; Suyun CHEN ; Qianhong WU ; Dong WU ; Min ZHANG ; Keguo ZHENG
Chinese Journal of Postgraduates of Medicine 2010;33(35):5-7
Objective To evaluate the X-ray diagnosis value of intestinal malrotation in adults.Methods The X-ray findings of 16 cases with intestinal malrotation confirmed by surgery were analyzed retrospectively. All of them were taken X-ray plain films, 11 cases were taken alimentary tract barium meal,and 5 cases were taken barium enema. Results Eight cases were found incomplete obstruction of the duodenum, and 2 cases were found low small intestine obstruction on the X-ray plain films. The alimentary tract barium meal showed 4 cases with dilatation and incomplete obstruction of the duodenal bulb to horizontal segment,and the distal end of narrowing intestine appeared as a rat tail,7 cases showed the abnormal duodenal location and shape,called "strip" sign. Four cases were found abnormal duodenojejunal flexure by barium enema examination. Conclusion The alimentary tract barium meal and barium enema examination has great diagnosis value for intestinal malrotation in adults.

Result Analysis