1.Effects of acupoint catgut embedding on gut microbiota and fecal short-chain fatty acids in Parkinson's disease patients with constipation.
Xiaomei ZHANG ; Jie JIANG ; Wenying LI ; Juping CHEN ; Yin HUANG ; Wei REN ; Yafang SONG ; Jianhua SUN
Chinese Acupuncture & Moxibustion 2025;45(11):1533-1540
OBJECTIVE:
To observe the effects of acupoint catgut embedding (ACE) on gut microbiota and fecal short-chain fatty acids (SCFAs) levels in patients with Parkinson's disease (PD) with constipation.
METHODS:
A total of 80 PD patients with constipation were randomly divided into an observation group and a control group, 40 cases in each group. Additionally, 40 healthy individuals were recruited as a healthy control group. The control group received conventional Western medical treatment for PD combined with polyethylene glycol (PEG), once daily for eight weeks. The observation group received additional ACE treatment at bilateral Tianshu (ST25), Zusanli (ST36), and Shangjuxu (ST37), once every two weeks for eight weeks. The healthy control group received no intervention. The spontaneous bowel movements (SBMs) per week and patient assessment of constipation quality of life (PAC-QOL) scores were assessed at baseline and after treatment in the two groups. Fecal samples were collected at the end of treatment for the observation and the control groups and at baseline for the healthy control group. Gut microbiota composition and diversity were analyzed using 16S rRNA method, and SCFA levels were measured using high-performance liquid chromatography (HPLC).
RESULTS:
Compared before treatment, the observation group showed a significant increase in SBMs (P<0.01), and PAC-QOL scores including physical discomfort, psychosocial discomfort, worry and concern, and total score were significantly reduced (P<0.01) after treatment; the control group also showed a reduction in PAC-QOL total score after treatment (P<0.01). After treatment, the observation group had significantly more SBMs (P<0.01), and lower PAC-QOL physical discomfort, psychosocial discomfort, worry and concern scores, and total score (P<0.01), and higher PAC-QOL satisfaction score (P<0.01) than the control group. Compared with the healthy control group, the control group showed decreased Chao1 and Ace indices (P<0.01). Compared with the healthy control group, the relative abundance of Prevotella and Roseburia was increased (P<0.05), while that of Enterobacter and Ruminococcus torques (six species in total) was decreased (P<0.05) in the control group. Compared with the control group, the observation group had increased relative abundance of Dialister, Parabacteroides, and Ruminococcus torques (P<0.05), and decreased relative abundance of Prevotella and Eubacterium ruminantium (P<0.05). Compared with the healthy control group, the control group had increased fecal SCFA levels (P<0.05); compared with the control group, the observation group had reduced fecal SCFA levels (P<0.05). Compared with the healthy control group, acetic acid, propionic acid, and butyric acid levels were elevated in the control group (P<0.05); compared with the control group, acetic acid, propionic acid, and butyric acid levels were decreased in the observation group (P<0.05).
CONCLUSION
ACE could increase spontaneous bowel movements and improve the quality of life in PD patients with constipation, which may be related to the regulation of gut microbiota composition and SCFA levels.
Humans
;
Constipation/metabolism*
;
Male
;
Gastrointestinal Microbiome
;
Acupuncture Points
;
Female
;
Middle Aged
;
Parkinson Disease/complications*
;
Aged
;
Fatty Acids, Volatile/metabolism*
;
Catgut
;
Feces/microbiology*
;
Acupuncture Therapy
;
Quality of Life
;
Adult
2.Research on flow characteristics of dual-outlet centrifugal disk blood pumps.
Qilong LIAN ; Yuan XIAO ; Yiping XIAO ; Zhanshuo CAO ; Guomin CUI
Journal of Biomedical Engineering 2025;42(2):374-381
Tesla blood pumps demonstrate a reduced propensity for hemolysis and thrombosis compared with vane blood pumps. Considering the restricted driving force within the secondary flow channel of vane blood pumps, along with the low hydraulic efficiency of conventional Tesla blood pumps and their internal flow characteristics that significantly contribute to hemolysis and thrombosis, this study introduces a set of vanes atop the rotor of the Tesla blood pump. This forms a dual-fluid domain rotor, and an axial dual-outlet volute shell structure is adopted to realize the separation of the fluid domains. Through numerical simulations of the new structure, a comparative analysis was conducted in this study on the internal flow characteristics of double-outlet and single-outlet volute shells, and symmetric and asymmetric cross-sections of the same rotor. The results indicate that the flow field distribution is more uniform under the double-outlet volute shell structure, and overall energy dissipation is decreased. After implementing the double-outlet design, in the asymmetric cross-section, compared with the symmetric cross-section, the fluid velocity gradient and turbulent kinetic energy at the tongue of the septum are reduced, and the fluid velocity gradient at the convergence of the diffuser tube outlets are also decreased. The maximum scalar stress is lower, and the decline in head and efficiency is mitigated. Moreover, compared with the single-outlet volute shell, the hemolysis index in the asymmetric cross-section is reduced. In summary, this paper proposes a novel dual-outlet centrifugal disk blood pumps, which can provide a reference for the structural design and performance optimization of magnetically levitated centrifugal blood pumps.
Heart-Assist Devices
;
Humans
;
Equipment Design
;
Hemolysis
;
Computer Simulation
3.Feasibility study on biomechanical indicators as supplementary evaluation to Musculoskeletal Tumor Society Scoring System for amputee patients.
Lingjie ZENG ; Xuanhong HE ; Minxun LU ; Yong NIE ; Xiangdong ZHU ; Chongqi TU
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(6):729-734
OBJECTIVE:
To explore the feasibility of using biomechanical indicators as supplementary evaluation to the Musculoskeletal Tumor Society Scoring System (MSTS) for amputee patients.
METHODS:
Twenty-four patients who underwent hemipelvectomy between September 2018 and January 2025 were enrolled. There were 15 males and 9 females with an average age of 61.4 years (range, 45-76 years). Participants performed gait tests at self-selected speeds using three assistive devices (prosthesis, single crutch, and double crutches). Motion data were analyzed using a customized OpenSim model. Biomechanical indicators of the intact limb exhibiting common characteristics were screened through correlation and sensitivity analyses. Test-retest reliability [interclass correlation coefficient (ICC)] of selected parameters was assessed to evaluate their potential as MSTS score supplements.
RESULTS:
All biomechanical indicators showed significant positive correlations with MSTS scores across assistive devices ( P<0.05). Seven indicators demonstrated |Pearson correlation coefficients|>0.8, including walking speed, maximum hip angle, maximum hip moment, peak hip flexion moment, peak hip extension moment, hip flexion impulse, and hip extension impulse. Among these, maximum hip moment, hip flexion impulse, and hip extension impulse exhibited significant between-group differences in adjacent MSTS levels ( P<0.05), indicating high sensitivity, along with excellent test-retest reliability (ICC>0.74, P<0.01).
CONCLUSION
Biomechanical indicators statistically qualify as potential supplements to MSTS scoring. Maximum hip moment, hip flexion impulse, and hip extension impulse demonstrate particularly high sensitivity to MSTS score variations.
Humans
;
Male
;
Middle Aged
;
Female
;
Aged
;
Biomechanical Phenomena
;
Amputees/rehabilitation*
;
Feasibility Studies
;
Artificial Limbs
;
Reproducibility of Results
;
Amputation, Surgical
;
Crutches
;
Gait
4.Manual reduction combined with 3D printed small splint in treating humeral shaft fractures.
Qiang WANG ; Yan-Kui LENG ; Bo ZHAI ; Jia-Yi XU ; Geng-Sheng JI
China Journal of Orthopaedics and Traumatology 2025;38(4):364-370
OBJECTIVE:
To analyze the clinical efficacy of manual reduction combined with 3D printing small splint external fixation and synchronous manual reduction combined with traditional small splint external fixation in the treatment of humeral shaft.
METHODS:
Between January 2021 and December 2022, 40 patients with humeral shaft fractures were treated with 3D printing small splints and traditional small splints. They were divided into 3D group and traditional group according to different fixation methods. Among them, there were 15 males and 5 females in the 3D group, aged from 20 to 52 years old with an average of (36.3±15.6) years old. In the traditional group there were 17 males and 3 females, aged from16 to 51 years old with an average of (32.9±17.2) years old. The occurrence of complications, duration of fracture healing, rate of fracture healing, subjective evaluation scores for brace comfort at 1 week and 4 weeks, as well as the Constant-Murley shoulder function score and Mayo elbow function score at 8 weeks and 16 weeks were compared between the two groups.
RESULTS:
All patients were followed up for 16 weeks. The 3D group did not experience any complications, while there were two cases of complications in the traditional group. However, this difference was not found to be statistically significant (χ2=2.105, P=0.146). The fracture healing time of the 3D group (90.1±4.5) days was significantly shorter compared to that of the traditional group (93.3±3.8) days (P<0.05). The subjective evaluation scores for brace comfort in the 3D group (53.7±2.3) points and (62.8±1.1) points were significantly higher than those in the traditional group (45.6±2.4) points and (52.3±1.4) points at 1 and 4 weeks after reduction (P<0.05). After 8 weeks of reduction, the Constant-Murley shoulder function score in the 3D group was(68.1±5.3) points, which demonstrated a statistically significant improvement compared to the traditional group(54.3±4.9) points (P<0.05). However, at 16 weeks post-reduction, there were no significant differences observed between the two groups (P>0.05). The Mayo elbow function score of the 3D group (84.1±7.5) points was significantly superior to that of the traditional group (79.5±6.8) points at 8 weeks post-reduction (P<0.05). However, there was no statistically significant difference between the two groups at 16 weeks post-reduction (P>0.05).
CONCLUSION
For humeral shaft fractures with conservative treatment indications, manual reduction combined with 3D printed small splints is a good choice for treatment. The patient's comfort level is higher, which can not only reduce the occurrence of complications, but also improve the fracture healing rate and joint function to a certain extent, and improve the patient's quality of life.
Humans
;
Female
;
Male
;
Adult
;
Middle Aged
;
Humeral Fractures/physiopathology*
;
Printing, Three-Dimensional
;
Splints
;
Adolescent
;
Young Adult
;
Fracture Healing
5.Clinical observation on the efficacy of self-made anatomical tower-shaped pad combined with splint plaster fixation in the treatment of unstable the 2nd to 5th metacarpal fractures.
Xiao-Bao WU ; Xiao-Rong ZHENG ; Zhen-Sheng WANG ; Zhi-Qiang LIN
China Journal of Orthopaedics and Traumatology 2025;38(7):747-751
OBJECTIVE:
To evaluate the clinical efficacy of self-made anatomical tower-shaped pads combined with splint plaster fixation in the treatment of unstable 2nd to 5th metacarpal fractures and to provide a reference for clinical practice.
METHODS:
A retrospective analysis was conducted on 98 patients with unstable 2nd to 5th metacarpal fractures treated with self-made anatomical tower-shaped pads combined with splint plaster fixation between January 2019 and December 2022. There were 74 males and 24 females, aged from 19 to 63 years old with an average of (41.58±7.23) years old. The total active movement (TAM) score was used to evaluate the metacarpophalangeal joint function. Complications and fracture healing time were recorded.
RESULTS:
All patients were followed up for a period ranging from 1 to 5 months, with an average duration of (3.45±1.03) months. Among the 98 patients, anatomical alignment was achieved in 75 patients, with 68 patients still maintaining anatomical alignment after fixation removal. Functional alignment was achieved in 23 patients, with 20 patients maintaining functional alignment even after fixation removal. There were 10 patients with displacement after reduction. The average fracture healing time was (5.78±1.14) weeks, and the fracture healed well without any angular or rotational deformities. TAM score was utilized to assess the hand function of patients 3 months post-treatment. The extension range of motion (10.72±1.35)° and flexion range of motion (83.19±4.08)° of the metacarpophalangeal joint were significantly higher than the pre-treatment values of (8.25±0.68)° and (70.35±2.36)°, respectively. These differences were statistically significant (P<0.05). TAM outcomes were excellent in 92 cases, good in 5, fair in 1, and poor in none.
CONCLUSION
The implementation of self-made anatomical tower-shaped pad combined with splint plaster fixation is effective for the conservative management of unstable 2nd to 5th metacarpal fractures.
Humans
;
Male
;
Female
;
Adult
;
Middle Aged
;
Metacarpal Bones/surgery*
;
Splints
;
Retrospective Studies
;
Fractures, Bone/therapy*
;
Casts, Surgical
;
Young Adult
;
Fracture Fixation, Internal/instrumentation*
6.Application progress on functional insoles in the prevention and treatment of diabetic foot.
Heng-Yu LIU ; Zhen-de JIANG ; Yao-Kuan RUAN ; Qiu-Ju LI ; Si-Yuan CHEN ; Shun-Yu WEI ; Nan MEI ; Chou WU ; Fei CHANG
China Journal of Orthopaedics and Traumatology 2025;38(9):969-975
Diabetic foot (DF) is one of the most serious chronic complications of diabetes. The incidence rate among global diabetes patients is as high as 15% to 25%, and about 50% of patients will develop contralateral foot ulcers within 5 years after the first unilateral ulcer. As a non-invasive prevention and control solution, the application progress of functional insoles is mainly reflected in the following aspects:(1) Material innovation. The application of new composite materials and smart materials has significantly enhanced the pressure reduction effect and comfort. (2) Structural optimization. The development of multi-layer design and local pressure reduction structure has achieved more precise pressure distribution regulation. (3) Manufacturing process. 3D printing and parametric design have enabled the personalized customization of functional insoles. (4) Intelligent monitoring. It integrates functions such as pressure sensing and temperature monitoring, achieving real-time monitoring and early warning of foot conditions. Clinical research has confirmed that personalized functional insoles could reduce the incidence of foot ulcers and shorten the healing time of ulcers. At present, the research hotspots mainly focus on the development of smart materials, the construction of multi-functional integration and remote monitoring systems. However, in-depth research is still needed in the aspects of biomechanical mechanisms, standardized evaluation systems and long-term efficacy assessment. The development of future functional insoles should focus on the coordinated advancement of "personalization-intelligence-standardization", with the aim of providing more effective solutions for the prevention and treatment of DF.
Humans
;
Diabetic Foot/therapy*
;
Foot Orthoses
7.Application of dual chamber round tissue expander in immediate breast reconstruction.
Jianxun MA ; Xi BU ; Bi LI
Journal of Peking University(Health Sciences) 2025;57(1):166-171
OBJECTIVE:
To explore the application value of dual chamber round tissue expander in immediate breast reconstruction.
METHODS:
Sixteen patients, who had been provided immediate tissue expander/implant two-stage breast reconstruction using dual chamber round tissue expander in our hospital from March 2022 to October 2023, were involved in this study, and the relevant information was analyzed retrospectively. The overall design of the expander is a round shape, consisting of two equally divided semi-circular chambers. The two expansion chambers are connected by a silicone pad below and are respectively connected to their own water injection tubes. Both chambers are designed to expand unidirectionally towards the surface. The expansion principle, insertion process, and type of expander selection were investigated. The expansion effect and incidence of complications were summarized. The aesthetic effect of reconstructed breasts was evaluated from three aspects after stage Ⅱ surgery: the position of infra mammary fold, the breast protrusion, and the breast volume.
RESULTS:
Among sixteen patients in this study, three patients were selected with the type of 400 mL expander and thirteen patients were given the type of 600 mL expander. The median time of tissue expansion was 4.0 (2.0, 5.0) months, with an average volume of expansion of (538.8±111.7) mL. The average expansion ratio of upper/lower chamber was 45.4%±8.4%. The position of the infra mammary fold needed not to be adjusted during the prosthesis exchange process. All the patients were applied anatomical prostheses, and the median volume of the prosthesis was 395 (345, 410) mL. One patient developed seroma during expansion period, who got improved after local aspiration. The average follow-up time was (9.0±3.6) months. 81.3% (13/16) of the patients achieved an aesthetic evaluation of "Good" in breast reconstruction, and 75.0% (12/16) of the patients got a grade Ⅰ or grade Ⅱ capsule contracture of the prosthesis.
CONCLUSION
The application of dual chamber round tissue expander could effectively dilate the lower pole of the breast, personalize the expansion ratio of the upper and lower poles of the breast, and avoid the displacement of the expander during the expansion period. Therefore, it could provide a good foundation for subsequent prosthesis exchange.
Humans
;
Tissue Expansion Devices
;
Female
;
Mammaplasty/instrumentation*
;
Tissue Expansion/instrumentation*
;
Retrospective Studies
;
Adult
;
Middle Aged
;
Breast Neoplasms/surgery*
;
Breast Implants
;
Mastectomy
8.Optimization of flow rate and orientation of outflow graft at implantation for patients with left ventricular assist device.
Yongyi WANG ; Li SHI ; Shijun HU ; Xiao TAN ; Tianli ZHAO
Journal of Central South University(Medical Sciences) 2025;50(3):457-468
OBJECTIVES:
A ventricular assist device (VAD) is an electromechanical device used to assist cardiac blood circulation, which can be employed for the treatment of end-stage heart failure and is most commonly placed in the left ventricle. Despite enhancing perfusion performance, the implantation of left ventricular assist device (LVAD) transforms the local intraventricular flow and thus may increase the risk of thrombogenesis. This study aims to investigate fluid-particle interactions and thromboembolic risk under different LVAD configurations using three-dimensional (3D) reconstruction models, focusing on the effects of outflow tract orientation and blood flow rates.
METHODS:
A patient-specific end-diastolic 3D reconstruction model was initially constructed in stereo lithography (STL) format using Mimics software based on CT images. Transient numerical simulations were performed to analyze fluid-particle interactions and thromboembolic risks for LVAD with varying outflow tract orientations under 2 flow rates (4 L/min and 5 L/min), using particles of uniform size (2 mm), and a blood flow rate optimization protocol was implemented for this patient.
RESULTS:
When the LVAD flow rate was 5 L/min, helicity and flow stagnation of the blood flow increased the particle residence time (RT) and the risk of thrombogenesis of the aortic root. The percentage of particles traveling toward the brachiocephalic trunk was up to 20.33%. When the LVAD flow rate was 4 L/min, blood turbulence in the aorta was reduced, the RT of blood particles was shortened, and then the percentage of particles traveling toward the brachiocephalic trunk decreased to 10.54%. When the LVAD blood flow rate was 5 L/min and the direction of the outflow pipe was optimal, the RT of blood particles was shortened, and then the percentage of particles traveling toward the brachiocephalic trunk decreased to 11.22%. A 18-month follow-up observation of the patient revealed that the LVAD was in good working order and the patient had no complications related to the implantation of LVAD.
CONCLUSIONS
Implantation of LVAD results in a higher risk of cerebral infarction; When implanting LVAD with the same outflow tract direction, optimizing flow velocity and outflow tract can reduce the risk of cerebral infarction occurrence.
Heart-Assist Devices/adverse effects*
;
Humans
;
Heart Failure/physiopathology*
;
Blood Flow Velocity
;
Thromboembolism/prevention & control*
;
Models, Cardiovascular
;
Heart Ventricles/physiopathology*
;
Imaging, Three-Dimensional
9.Preliminary evaluation of modified anterior splint combined with anterior repositioning splint after successful mandibular manipulation in treatment of acute anterior disc displacement without reduction of temporomandibular joint.
Chao HUANG ; Xingsheng WU ; Zhen ZHAN ; Lin ZHANG ; Lianshui SHI
West China Journal of Stomatology 2025;43(2):262-268
OBJECTIVES:
Magnetic resonance imaging (MRI) was used to study the efficacy of modified anterior splint (MAS) combined with anterior repositioning splint (ARS) in maintaining the normal disk-condyle relationship.
METHODS:
We obtained clinical and imaging data of 10 patients with acute anterior disk displacement without reduction (ADDwoR) of the temporomandibular joint undergoing successful mandibular manipulation in the Affiliated Stomatological Hospital, Nanchang University from January to June 2024. The MAS and ARS were used for subsequent treatment. Maximum active mouth opening (MMO) and visual analogue score (VAS) were recorded before treatment and 2 weeks, 1 month, and 3 months after treatment. The changes in the disk-condyle relationship, disk-condyle angle, joint effusion, and double contour sign before and after treatment were analyzed through MRI.
RESULTS:
Three months after treatment, the MMO increased from 28.90 mm to 46.85 mm, VAS decreased from 4.68 to 0.61, and the disk-condyle angle decreased from 58.84° to 25.99°. MRI analysis found that 6 patients showed normal disk-condyle relationship, 2 patients exhibited displacement with reduction, and 2 patients exhibited ADDwoR. The disk-condyle angle was 58.84° before treatment and 25.99° after treatment.
CONCLUSIONS
The MAS combined with ARS could further stabilize the coordinated disk-condyle relationship and reduce the recurrence rate.
Humans
;
Male
;
Magnetic Resonance Imaging
;
Female
;
Adult
;
Temporomandibular Joint Disorders/diagnostic imaging*
;
Splints
;
Middle Aged
;
Mandible
;
Temporomandibular Joint Disc
;
Occlusal Splints
;
Temporomandibular Joint
;
Young Adult
;
Joint Dislocations/therapy*
10.Optimization of centrifugal artificial heart pump blade parameters based on back propagation neural network and grey wolf optimization algorithm.
Lulu MU ; Huanhuan DUAN ; Yuan XIAO ; Guomin CUI
Journal of Biomedical Engineering 2024;41(6):1221-1226
The impeller, as a key component of artificial heart pumps, experiences high shear stress due to its rapid rotation, which may lead to hemolysis. To enhance the hemolytic performance of artificial heart pumps and identify the optimal combination of blade parameters, an optimization design for existing pump blades is conducted. The number of blades, outlet angle, and blade thickness were selected as design variables, with the maximum shear stress within the pump serving as the optimization objective. A back propagation (BP) neural network prediction model was established using existing simulation data, and a grey wolf optimization algorithm was employed to optimize the blade parameters. The results indicated that the optimized blade parameters consisted of 7 impeller blades, an outlet angle of 25 °, and a blade thickness of 1.2 mm; this configuration achieved a maximum shear stress value of 377 Pa-representing a reduction of 16% compared to the original model. Simulation analysis revealed that in comparison to the original model, regions with high shear stress at locations such as the outer edge, root, and base significantly decreased following optimization efforts, thus leading to marked improvements in hemolytic performance. The coupling algorithm employed in this study has significantly reduced the workload associated with modeling and simulation, while also enhancing the performance of optimization objectives. Compared to traditional optimization algorithms, it demonstrates distinct advantages, thereby providing a novel approach for investigating parameter optimization issues related to centrifugal artificial heart pumps.
Neural Networks, Computer
;
Algorithms
;
Heart-Assist Devices
;
Hemolysis
;
Humans
;
Equipment Design
;
Stress, Mechanical
;
Computer Simulation

Result Analysis
Print
Save
E-mail