1.Effect of Occlusal and Margin Design on the Fracture Load of Zirconia-Lithium Disilicate Bi-layered Posterior Crowns: An in Vitro Study
Sung-Hoon KIM ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
Journal of Korean Dental Science 2025;18(1):1-11
Purpose:
The opacity of zirconia sometimes requires a veneering material; thus lithium disilicate, a veneer material with excellent strength, can be used. This study investigated the fracture resistance of zirconia–lithium disilicate (Zr-LS2) bi-layered crowns according to the design of the substructure.
Materials and Methods:
Five groups of posterior Zr-LS2 restorations (Zirtooth and Amber LiSi-POZ) were fabricated with different zirconia substructure coverage (control group, groups half occlusal zirconia coverage; 1/2OZ, and three-quarter occlusal zirconia coverage; 3/4OZ) and margin designs (control group, groups collar margin; C-M, and collarless margin; Cl-M). All restorations were cemented with self-adhesive resin cement followed by 24-h water storage and thermocycling (10,000 cycles, 5°C and 55°C). The fracture load was measured, and failure mode analysis, fractography, and elemental analysis were performed. The one-way analysis of variance and Fisher’s exact test were performed for statistical analyses (α=.05).
Results:
A significant difference was found in the fracture load of Zr-LS2 restorations according to the zirconia coverage of the occlusal area and margin design (P<.05). Group 3/4OZ was significantly larger than the control group C and 1/2OZ (P<.05). The C-M group had greater fracture loads based on margin design than the control group C and Cl-M (P<.05).
Conclusion
The fracture resistance of posterior Zr-LS2 restorations increased with the zirconia coverage, occlusal thickness, and collar margin.
2.Effect of Occlusal and Margin Design on the Fracture Load of Zirconia-Lithium Disilicate Bi-layered Posterior Crowns: An in Vitro Study
Sung-Hoon KIM ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
Journal of Korean Dental Science 2025;18(1):1-11
Purpose:
The opacity of zirconia sometimes requires a veneering material; thus lithium disilicate, a veneer material with excellent strength, can be used. This study investigated the fracture resistance of zirconia–lithium disilicate (Zr-LS2) bi-layered crowns according to the design of the substructure.
Materials and Methods:
Five groups of posterior Zr-LS2 restorations (Zirtooth and Amber LiSi-POZ) were fabricated with different zirconia substructure coverage (control group, groups half occlusal zirconia coverage; 1/2OZ, and three-quarter occlusal zirconia coverage; 3/4OZ) and margin designs (control group, groups collar margin; C-M, and collarless margin; Cl-M). All restorations were cemented with self-adhesive resin cement followed by 24-h water storage and thermocycling (10,000 cycles, 5°C and 55°C). The fracture load was measured, and failure mode analysis, fractography, and elemental analysis were performed. The one-way analysis of variance and Fisher’s exact test were performed for statistical analyses (α=.05).
Results:
A significant difference was found in the fracture load of Zr-LS2 restorations according to the zirconia coverage of the occlusal area and margin design (P<.05). Group 3/4OZ was significantly larger than the control group C and 1/2OZ (P<.05). The C-M group had greater fracture loads based on margin design than the control group C and Cl-M (P<.05).
Conclusion
The fracture resistance of posterior Zr-LS2 restorations increased with the zirconia coverage, occlusal thickness, and collar margin.
3.Effect of Occlusal and Margin Design on the Fracture Load of Zirconia-Lithium Disilicate Bi-layered Posterior Crowns: An in Vitro Study
Sung-Hoon KIM ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
Journal of Korean Dental Science 2025;18(1):1-11
Purpose:
The opacity of zirconia sometimes requires a veneering material; thus lithium disilicate, a veneer material with excellent strength, can be used. This study investigated the fracture resistance of zirconia–lithium disilicate (Zr-LS2) bi-layered crowns according to the design of the substructure.
Materials and Methods:
Five groups of posterior Zr-LS2 restorations (Zirtooth and Amber LiSi-POZ) were fabricated with different zirconia substructure coverage (control group, groups half occlusal zirconia coverage; 1/2OZ, and three-quarter occlusal zirconia coverage; 3/4OZ) and margin designs (control group, groups collar margin; C-M, and collarless margin; Cl-M). All restorations were cemented with self-adhesive resin cement followed by 24-h water storage and thermocycling (10,000 cycles, 5°C and 55°C). The fracture load was measured, and failure mode analysis, fractography, and elemental analysis were performed. The one-way analysis of variance and Fisher’s exact test were performed for statistical analyses (α=.05).
Results:
A significant difference was found in the fracture load of Zr-LS2 restorations according to the zirconia coverage of the occlusal area and margin design (P<.05). Group 3/4OZ was significantly larger than the control group C and 1/2OZ (P<.05). The C-M group had greater fracture loads based on margin design than the control group C and Cl-M (P<.05).
Conclusion
The fracture resistance of posterior Zr-LS2 restorations increased with the zirconia coverage, occlusal thickness, and collar margin.
4.Effect of Occlusal and Margin Design on the Fracture Load of Zirconia-Lithium Disilicate Bi-layered Posterior Crowns: An in Vitro Study
Sung-Hoon KIM ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
Journal of Korean Dental Science 2025;18(1):1-11
Purpose:
The opacity of zirconia sometimes requires a veneering material; thus lithium disilicate, a veneer material with excellent strength, can be used. This study investigated the fracture resistance of zirconia–lithium disilicate (Zr-LS2) bi-layered crowns according to the design of the substructure.
Materials and Methods:
Five groups of posterior Zr-LS2 restorations (Zirtooth and Amber LiSi-POZ) were fabricated with different zirconia substructure coverage (control group, groups half occlusal zirconia coverage; 1/2OZ, and three-quarter occlusal zirconia coverage; 3/4OZ) and margin designs (control group, groups collar margin; C-M, and collarless margin; Cl-M). All restorations were cemented with self-adhesive resin cement followed by 24-h water storage and thermocycling (10,000 cycles, 5°C and 55°C). The fracture load was measured, and failure mode analysis, fractography, and elemental analysis were performed. The one-way analysis of variance and Fisher’s exact test were performed for statistical analyses (α=.05).
Results:
A significant difference was found in the fracture load of Zr-LS2 restorations according to the zirconia coverage of the occlusal area and margin design (P<.05). Group 3/4OZ was significantly larger than the control group C and 1/2OZ (P<.05). The C-M group had greater fracture loads based on margin design than the control group C and Cl-M (P<.05).
Conclusion
The fracture resistance of posterior Zr-LS2 restorations increased with the zirconia coverage, occlusal thickness, and collar margin.
5.Restoration of IARPD in partially edentulous patients with bone defects due to osteomyelitis treatment
Se-Hyun PARK ; Han-Gyul SUNG ; Kyung-Ho KO ; Yoon-Hyuk HUH ; Chan-Jin PARK ; Lee-Ra CHO
The Journal of Korean Academy of Prosthodontics 2021;59(3):359-369
Implant prostheses and removable partial dentures are mainly used as treatment methods for partial edentulous patients who have lost a number of teeth. The implant-assisted removable partial denture (IARPD) is strategically selected. The defect in maxillofacial structure due to osteomyelitis, a type of facial bone infection, causes dysfunction such as mastication, swallowing, and pronunciation, as well as social and psychological effects, so a removable restoration is required to restore the supporting tissue. Design of abutment and partial dentures is an essential factor in the success of treatment. In this case, IARPD, which has superior retention and stability compared to traditional removable partial dentures, can have a good prognosis. In a partial edentulous patient with bone defects due to osteomyelitis treatment, the stability of the denture was secured with IARPD restoration. Moreover, maintenance problem that may occur in the future was minimized by providing an appropriate denture design and occlusal scheme through several provisional restorations. This case can be expected to have a favorable prognosis in the long term.
6.Restoration of IARPD in partially edentulous patients with bone defects due to osteomyelitis treatment
Se-Hyun PARK ; Han-Gyul SUNG ; Kyung-Ho KO ; Yoon-Hyuk HUH ; Chan-Jin PARK ; Lee-Ra CHO
The Journal of Korean Academy of Prosthodontics 2021;59(3):359-369
Implant prostheses and removable partial dentures are mainly used as treatment methods for partial edentulous patients who have lost a number of teeth. The implant-assisted removable partial denture (IARPD) is strategically selected. The defect in maxillofacial structure due to osteomyelitis, a type of facial bone infection, causes dysfunction such as mastication, swallowing, and pronunciation, as well as social and psychological effects, so a removable restoration is required to restore the supporting tissue. Design of abutment and partial dentures is an essential factor in the success of treatment. In this case, IARPD, which has superior retention and stability compared to traditional removable partial dentures, can have a good prognosis. In a partial edentulous patient with bone defects due to osteomyelitis treatment, the stability of the denture was secured with IARPD restoration. Moreover, maintenance problem that may occur in the future was minimized by providing an appropriate denture design and occlusal scheme through several provisional restorations. This case can be expected to have a favorable prognosis in the long term.
7.Clinical assessment after human adipose stem cell transplantation into dogs
Seok Hee LEE ; Erif M N SETYAWAN ; Yoo Bin CHOI ; Jeong Chan RA ; Sung Keun KANG ; Byeong Chun LEE ; Geon A KIM
Journal of Veterinary Science 2018;19(3):452-461
Adipose tissue-derived stem cell (ASCs) are an attractive source of stem cells with therapeutic applicability in various fields for regenerating damaged tissues because of their stemness characteristics. However, little has reported on evaluating adverse responses caused by human ASC therapy. Therefore, in the present study, a clinical assessment after human ASC transplantation into dogs was undertaken. A total of 12 healthy male dogs were selected and divided into four groups: saline infusion, saline bolus, ASC infusion, and ASC bolus groups. Physical assessment and blood analysis were performed following ASC transplantation, and the concentrations of angiogenic factors, and pro- and anti-inflammatory cytokines were measured by enzyme-linked immunosorbent assay (ELISA). There were no adverse vital sign responses among the dogs. Blood analyses revealed no remarkable complete blood count or serum chemistry results. ELISA results for angiogenic and anti-inflammatory factors including matrix metalloproteinase 9 (MMP9), vascular endothelial growth factor (VEGF), basic fibroblast growth factor (bFGF), hepatocyte growth factor (HGF), and interleukin-10 (IL-10) were significantly higher in the two ASCs groups than in the controls. In conclusion, this study demonstrated that transplantation of human ASCs produced no adverse effects and could be used safely in dogs. In addition, human ASCs could be involved in modulating secretions of angiogenic factors including MMP9, VEGF, bFGF, and HGF and anti-inflammatory factor IL-10.
Angiogenesis Inducing Agents
;
Animals
;
Blood Cell Count
;
Chemistry
;
Cytokines
;
Dogs
;
Enzyme-Linked Immunosorbent Assay
;
Fibroblast Growth Factor 2
;
Hepatocyte Growth Factor
;
Humans
;
Interleukin-10
;
Male
;
Matrix Metalloproteinase 9
;
Stem Cell Transplantation
;
Stem Cells
;
Transplantation
;
Vascular Endothelial Growth Factor A
;
Vital Signs
8.Literature review and case report of prosthetic rehabilitation with telescopic denture.
Han Gyul SUNG ; Eun Hye JO ; Kyung Ho KO ; Yoon Hyuk HUH ; Chan Jin PARK ; Lee Ra CHO
The Journal of Korean Academy of Prosthodontics 2018;56(4):308-316
Telescopic denture has advantages such as transfer the occlusal force to the long axis of the abutment, easiness of oral hygiene management, increase of retention and stability, splint effect due to secondary fixation between abutments and have been reported a higher success rates than conventional removable partial denture (RPD). However, there are disadvantages such as complex laboratory procedures, long treatment periods and high costs, and high incidence of complications. This clinical report describes two cases, a 4-point supported telescopic denture using telescopic crown and a 2-point supported telescopic denture using conical crown with functionally satisfactory results. Frequent complications of telescopic denture, which are reported in various literature were reviewed. Clinical and laboratory procedures were performed in consideration of complications that reported.
Bite Force
;
Crowns
;
Denture, Partial, Removable
;
Dentures*
;
Incidence
;
Oral Hygiene
;
Rehabilitation*
;
Splints
9.Dysphagia due to Upper Esophageal Sphincter Disorder after Suicide Attempts.
Myung Jin PARK ; Ah Ra JUNG ; Young Gyu EUN ; Dae Hyun KIM ; Sung Hoon CHUNG ; Young Chan LEE
Journal of Korean Medical Science 2017;32(8):1217-1219
No abstract available.
Deglutition Disorders*
;
Esophageal Sphincter, Upper*
;
Suicide*
10.Full-mouth rehabilitation of partial edentulism in a deep bite patient.
Sung Hoon KIM ; Ye Kyu RHEE ; Kyung Ho KO ; Yoon Hyuk HUH ; Lee Ra CHO ; Chan Jin PARK
The Journal of Korean Academy of Prosthodontics 2017;55(2):187-197
Deep overbite patients who do not have proper occlusal relationship may cause problems such as teeth wear and antagonist extrusion. These lead to the collapse of occlusal plane and esthetic problem. Increasing vertical dimension is frequently essential to resolve those problems. This case report demonstrates a full-mouth rehabilitation for a patient with severe deep bite that contacts surface to surface by increasing vertical dimension. Treatment procedures included diagnosis, treatment planning, implant surgery, and prosthodontic rehabilitation. Satisfactory results were obtained in functional and esthetic aspects.
Dental Occlusion
;
Diagnosis
;
Humans
;
Overbite*
;
Rehabilitation*
;
Tooth
;
Vertical Dimension

Result Analysis
Print
Save
E-mail