1.Intra-Articular Injection of Stem Cells for the Regeneration of Knee Joint Cartilage: a Therapeutic Option for Knee Osteoarthritis — a Narrative Review
Hyun Jae LEE ; Rajib HOSSAIN ; Chang-Heon BAEK ; Choong Jae LEE ; Sun-Chul HWANG
Biomolecules & Therapeutics 2025;33(1):86-94
Current approaches to regulating osteoarthritis primarily focus on symptom management; however, these methods often have significant side effects and may not be suitable for long-term care. As an alternative to conventional treatments, injecting stem cells into knee joint cartilage is a promising option for repairing damaged cartilage. In this review, we outline the general procedure for stem cell treatment of knee joint cartilage regeneration, emphasizing the potential of intra-articular stem cell injections as a therapeutic option for osteoarthritis. We examined and summarized patient evaluation and preparation for knee joint stem cell therapy, stem cell harvesting, stem cell preparation, injection procedures for stem cell therapy, post-injection care and monitoring, potential outcomes of stem cell therapy, and considerations and risks associated with stem cell therapy. Overall, stem cell injections for knee joint cartilage damage represent a promising frontier in orthopedic care. They offer potential benefits such as pain and inflammation reduction, promotion of cartilage repair and regeneration, and the possibility of avoiding more invasive treatments such as knee surgery. Ongoing collaboration among researchers, clinicians, and regulatory organizations is crucial for advancing this field and translating scientific discoveries into effective clinical applications.
2.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
3.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
4.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
5.Intra-Articular Injection of Stem Cells for the Regeneration of Knee Joint Cartilage: a Therapeutic Option for Knee Osteoarthritis — a Narrative Review
Hyun Jae LEE ; Rajib HOSSAIN ; Chang-Heon BAEK ; Choong Jae LEE ; Sun-Chul HWANG
Biomolecules & Therapeutics 2025;33(1):86-94
Current approaches to regulating osteoarthritis primarily focus on symptom management; however, these methods often have significant side effects and may not be suitable for long-term care. As an alternative to conventional treatments, injecting stem cells into knee joint cartilage is a promising option for repairing damaged cartilage. In this review, we outline the general procedure for stem cell treatment of knee joint cartilage regeneration, emphasizing the potential of intra-articular stem cell injections as a therapeutic option for osteoarthritis. We examined and summarized patient evaluation and preparation for knee joint stem cell therapy, stem cell harvesting, stem cell preparation, injection procedures for stem cell therapy, post-injection care and monitoring, potential outcomes of stem cell therapy, and considerations and risks associated with stem cell therapy. Overall, stem cell injections for knee joint cartilage damage represent a promising frontier in orthopedic care. They offer potential benefits such as pain and inflammation reduction, promotion of cartilage repair and regeneration, and the possibility of avoiding more invasive treatments such as knee surgery. Ongoing collaboration among researchers, clinicians, and regulatory organizations is crucial for advancing this field and translating scientific discoveries into effective clinical applications.
6.Intra-Articular Injection of Stem Cells for the Regeneration of Knee Joint Cartilage: a Therapeutic Option for Knee Osteoarthritis — a Narrative Review
Hyun Jae LEE ; Rajib HOSSAIN ; Chang-Heon BAEK ; Choong Jae LEE ; Sun-Chul HWANG
Biomolecules & Therapeutics 2025;33(1):86-94
Current approaches to regulating osteoarthritis primarily focus on symptom management; however, these methods often have significant side effects and may not be suitable for long-term care. As an alternative to conventional treatments, injecting stem cells into knee joint cartilage is a promising option for repairing damaged cartilage. In this review, we outline the general procedure for stem cell treatment of knee joint cartilage regeneration, emphasizing the potential of intra-articular stem cell injections as a therapeutic option for osteoarthritis. We examined and summarized patient evaluation and preparation for knee joint stem cell therapy, stem cell harvesting, stem cell preparation, injection procedures for stem cell therapy, post-injection care and monitoring, potential outcomes of stem cell therapy, and considerations and risks associated with stem cell therapy. Overall, stem cell injections for knee joint cartilage damage represent a promising frontier in orthopedic care. They offer potential benefits such as pain and inflammation reduction, promotion of cartilage repair and regeneration, and the possibility of avoiding more invasive treatments such as knee surgery. Ongoing collaboration among researchers, clinicians, and regulatory organizations is crucial for advancing this field and translating scientific discoveries into effective clinical applications.
7.Emodin Inhibited MUC5AC Mucin Gene Expression via Affecting EGFR-MAPK-Sp1 Signaling Pathway in Human Airway Epithelial Cells
Rajib HOSSAIN ; Hyun Jae LEE ; Chang-Heon BAEK ; Sun-Chul HWANG ; Choong Jae LEE
Biomolecules & Therapeutics 2024;32(6):736-743
The aim of this study was to evaluate emodin, a natural trihydroxyanthraquinone compound found in the roots and barks of several plants including rhubarb and buckthorn, might attenuate epidermal growth factor (EGF)-induced airway MUC5AC mucin gene expression. The human pulmonary mucoepidermoid NCI-H292 cells were pretreated with for 30 min and then stimulated with EGF for the following 24 h. The effect of emodin on EGF-induced mitogen-activated protein kinase (MAPK) signaling pathway was examined. As a result, emodin blocked the expression of MUC5AC mucin mRNA and production of mucous glycoprotein via suppressing the phosphorylation of EGF receptor (EGFR), phosphorylation of mitogen-activated protein kinase (MAPK)/extracellular signal-regulated kinase (ERK) 1 and 2 (MEK1/2), phosphorylation of p38 MAPK, phosphorylation of ERK 1/2 (p44/42), and the nuclear expression of specificity protein-1 (Sp1). These findings imply that emodin has a potential to mitigate EGF-stimulated mucin gene expression by inhibiting the EGFR-MAPK-Sp1 signaling pathway, in NCI-H292 cells.
8.Impacts of Tocolytics on Maternal and Neonatal Glucose Levels in Women With Gestational Diabetes Mellitus
Subeen HONG ; Hyun-Joo SEOL ; JoonHo LEE ; Han Sung HWANG ; Ji-Hee SUNG ; Ji Young KWON ; Seung Mi LEE ; Won Joon SEONG ; Soo Ran CHOI ; Seung Chul KIM ; Hee-Sun KIM ; Se Jin LEE ; Sae-Kyung CHOI ; Kyung A LEE ; Hyun Sun KO ; Hyun Soo PARK ;
Journal of Korean Medical Science 2024;39(34):e236-
Background:
We investigated the impacts of tocolytic agents on maternal and neonatal blood glucose levels in women with gestational diabetes mellitus (GDM) who used tocolytics for preterm labor.
Methods:
This multi-center, retrospective cohort study included women with GDM who were admitted for preterm labor from twelve hospitals in South Korea. We excluded women with multiple pregnancies, anomalies, overt DM diagnosed before pregnancy or 23 weeks of gestation, and women who received multiple tocolytics. The patients were divided according to the types of tocolytics; atosiban, ritodrine, and nifedipine group. We collected baseline maternal characteristics, pregnancy outcomes, maternal glucose levels during hospitalization, and neonatal glucose levels. We compared the frequency of maternal hyperglycemia and neonatal hypoglycemia among three groups. A multivariate logistic regression analysis was performed to evaluate the contributing factors to the occurrence of maternal hyperglycemia and neonatal hypoglycemia. Results: A total of 128 women were included: 44 (34.4%), 51 (39.8%), and 33 (25.8%) women received atosiban, ritodrine, and nifedipine, respectively. Mean fasting blood glucose (FBG) (112.3, 109.6, and 89.5 mg/dL, P < 0.001) and 2-hour postprandial glucose (PPG2) levels (145.4, 148.3, and 116.5 mg/dL, P = 0.004) were significantly higher in atosiban and ritodrine group than those in nifedipine group. Even after adjusting for covariates including antenatal steroid use, gestational age at admission, and pre-pregnancy body mass index, there was an increased risk of high maternal mean FBG (≥ 95 mg/dL) and PPG2 (≥ 120 mg/dL) levels in the atosiban and ritodrine group than in nifedipine group. The atosiban and ritodrine groups are also at increased risk of neonatal hypoglycemia (< 47 mg/dL) compared to the nifedipine group with the odds ratio of 4.58 and 4.67, respectively (P < 0.05).
Conclusion
There is an increased risk of maternal hyperglycemia and neonatal hypoglycemia in women with GDM using atosiban and ritodrine tocolytics for preterm labor compared to those using nifedipine.
9.Surgical treatment and recurrence of chronic subdural hematoma
Journal of the Korean Medical Association 2024;67(6):389-395
The incidence of chronic subdural hematoma (CSDH) is increasing owing to the rapid growth of the elderly population. CSDH causes various neurological symptoms such as cognitive impairment and motor dysfunction, which can improve with appropriate surgical management.Current Concepts: CSDH usually comprises a hemorrhagic fluid that accumulates within the subdural space and compresses the brain. Surgery is indicated if CSDH is associated with neurological symptoms and is aimed at safe and sufficient drainage of the hematoma. Currently, the recommended primary surgical method involves insertion of a draining catheter after burr hole or twist-drill trephination to facilitate drainage of the hematoma over a couple of days. Craniotomy is limited to cases of organized or calcified hematoma. The postoperative recurrence rate is approximately 10% to 20%. The same treatment method is attempted in cases of recurrence.Discussion and Conclusion: Surgical methods aim for rapid symptom relief and minimal invasiveness. Trephination and indwelling subdural catheter placement can enable immediate drainage of the hematoma and can be performed under local anesthesia. Preoperatively, it is necessary to obtain an accurate medical and medication history of elderly patients. Except in cases of emergencies, it is preferable to select the timing of the surgery only after reversal of the effects of drugs to prevent surgical complications in patients who receive anticoagulants or antiplatelet agents. Close postoperative follow-up is necessary in elderly patients because insufficient brain expansion leads to maintenance of the subdural space and is associated with a high risk of recurrence.
10.Development of an Instrument for Slit-lamp Examination of Donor Corneas in Preservation Medium
Ga Hee NAM ; Da Ran KIM ; Young Chae YOON ; Soon Won YANG ; Woong Joo WHANG ; Yong-Soo BYUN ; Hyung Bin HWANG ; Kyung Sun NA ; Hyun Soo LEE ; So Hyang CHUNG ; Eun Chul KIM ; Yang Kyung CHO ; Hyun Seung KIM ; Ho Sik HWANG
Journal of the Korean Ophthalmological Society 2024;65(2):108-116
Purpose:
To evaluate the effectiveness of an instrument devised for slit-lamp examination of donor corneas suspended in preservation medium.
Methods:
The study examined two donor corneas received at Yeouido St. Mary's Hospital in February 2023 and March 2023. The instrument has three main components: a plastic holder to hold the preservation medium bottle, a cube with a mirror for reflecting the slit beam, and a stand to attach the device to the slit-lamp. Using the instrument, the donor corneas were examined via slit-lamp: microscopy with the endothelium facing upward and downward. Specular microscopy and anterior segment optical coherence tomography (OCT) were also performed on the preserved donor corneas.
Results:
Slit-lamp examination of donor corneas in preservation medium using the instrument showed overall corneal buttoning and optical sections of the donor cornea. Using specular reflection and retroillumination, the endothelial layer was partially visible. However, specular microscopy and anterior segment OCT could not examine the donor cornea in preservation medium using the instrument.
Conclusions
The devised instrument facilitates slit-lamp examination of donor corneas in preservation medium, enabling a qualitative assessment of donor corneas before corneal transplantation surgery.

Result Analysis
Print
Save
E-mail