1.Catheter detection by transthoracic echocardiography during placement of peripherally inserted central catheters: a real-time method for eliminating misplacement
Yong Chae JUNG ; Man-shik SHIM ; Hee Sun PARK ; Min-Woong KANG
Acute and Critical Care 2024;39(2):266-274
Although guidelines and protocols are available for central venous access, existing methods lack specificity and sensitivity, especially when placing peripherally inserted central catheters (PICCs). We evaluated the feasibility of catheter detection in the right atrial cavity using transthoracic echocardiography (TTE) during PICC placement. Methods: This single-center, retrospective study included consecutive patients who underwent PICC placement between January 2022 and March 2023. TTE was performed to detect the arrival of the catheter in the right atrial cavity. Catheter misplacement was defined as an aberrant catheter position on chest x-ray (CXR). The primary endpoint was predicting catheter misplacement based on catheter detection in the right atrial cavity. The secondary endpoint was optimizing catheter placement and examining catheter-associated complications. Results: Of the 110 patients identified, 10 were excluded because of poor echogenicity and vein access failure. The remaining 100 patients underwent PICC placement with TTE. The catheter was visualized in the right atrial cavity in 90 patients. CXR exams revealed catheter misplacement in seven cases. Eight patients with catheter misplacement underwent the same procedure in the other arm. In two patients, PICC placement failed due to anatomical reasons. Catheter misplacement was detected using TTE with sensitivity, specificity, positive predictive value, and negative predictive value of 97% confidence interval (CI; 91.31%–99.36%), 90% CI (55.50%–99.75%), 99%, and 75%, respectively. Conclusions: TTE is a reliable tool for detecting catheter misplacement and optimizing catheter tip positioning during PICC placement.
2.Catheter detection by transthoracic echocardiography during placement of peripherally inserted central catheters: a real-time method for eliminating misplacement
Yong Chae JUNG ; Man-shik SHIM ; Hee Sun PARK ; Min-Woong KANG
Acute and Critical Care 2024;39(2):266-274
Although guidelines and protocols are available for central venous access, existing methods lack specificity and sensitivity, especially when placing peripherally inserted central catheters (PICCs). We evaluated the feasibility of catheter detection in the right atrial cavity using transthoracic echocardiography (TTE) during PICC placement. Methods: This single-center, retrospective study included consecutive patients who underwent PICC placement between January 2022 and March 2023. TTE was performed to detect the arrival of the catheter in the right atrial cavity. Catheter misplacement was defined as an aberrant catheter position on chest x-ray (CXR). The primary endpoint was predicting catheter misplacement based on catheter detection in the right atrial cavity. The secondary endpoint was optimizing catheter placement and examining catheter-associated complications. Results: Of the 110 patients identified, 10 were excluded because of poor echogenicity and vein access failure. The remaining 100 patients underwent PICC placement with TTE. The catheter was visualized in the right atrial cavity in 90 patients. CXR exams revealed catheter misplacement in seven cases. Eight patients with catheter misplacement underwent the same procedure in the other arm. In two patients, PICC placement failed due to anatomical reasons. Catheter misplacement was detected using TTE with sensitivity, specificity, positive predictive value, and negative predictive value of 97% confidence interval (CI; 91.31%–99.36%), 90% CI (55.50%–99.75%), 99%, and 75%, respectively. Conclusions: TTE is a reliable tool for detecting catheter misplacement and optimizing catheter tip positioning during PICC placement.
3.Catheter detection by transthoracic echocardiography during placement of peripherally inserted central catheters: a real-time method for eliminating misplacement
Yong Chae JUNG ; Man-shik SHIM ; Hee Sun PARK ; Min-Woong KANG
Acute and Critical Care 2024;39(2):266-274
Although guidelines and protocols are available for central venous access, existing methods lack specificity and sensitivity, especially when placing peripherally inserted central catheters (PICCs). We evaluated the feasibility of catheter detection in the right atrial cavity using transthoracic echocardiography (TTE) during PICC placement. Methods: This single-center, retrospective study included consecutive patients who underwent PICC placement between January 2022 and March 2023. TTE was performed to detect the arrival of the catheter in the right atrial cavity. Catheter misplacement was defined as an aberrant catheter position on chest x-ray (CXR). The primary endpoint was predicting catheter misplacement based on catheter detection in the right atrial cavity. The secondary endpoint was optimizing catheter placement and examining catheter-associated complications. Results: Of the 110 patients identified, 10 were excluded because of poor echogenicity and vein access failure. The remaining 100 patients underwent PICC placement with TTE. The catheter was visualized in the right atrial cavity in 90 patients. CXR exams revealed catheter misplacement in seven cases. Eight patients with catheter misplacement underwent the same procedure in the other arm. In two patients, PICC placement failed due to anatomical reasons. Catheter misplacement was detected using TTE with sensitivity, specificity, positive predictive value, and negative predictive value of 97% confidence interval (CI; 91.31%–99.36%), 90% CI (55.50%–99.75%), 99%, and 75%, respectively. Conclusions: TTE is a reliable tool for detecting catheter misplacement and optimizing catheter tip positioning during PICC placement.
4.Catheter detection by transthoracic echocardiography during placement of peripherally inserted central catheters: a real-time method for eliminating misplacement
Yong Chae JUNG ; Man-shik SHIM ; Hee Sun PARK ; Min-Woong KANG
Acute and Critical Care 2024;39(2):266-274
Although guidelines and protocols are available for central venous access, existing methods lack specificity and sensitivity, especially when placing peripherally inserted central catheters (PICCs). We evaluated the feasibility of catheter detection in the right atrial cavity using transthoracic echocardiography (TTE) during PICC placement. Methods: This single-center, retrospective study included consecutive patients who underwent PICC placement between January 2022 and March 2023. TTE was performed to detect the arrival of the catheter in the right atrial cavity. Catheter misplacement was defined as an aberrant catheter position on chest x-ray (CXR). The primary endpoint was predicting catheter misplacement based on catheter detection in the right atrial cavity. The secondary endpoint was optimizing catheter placement and examining catheter-associated complications. Results: Of the 110 patients identified, 10 were excluded because of poor echogenicity and vein access failure. The remaining 100 patients underwent PICC placement with TTE. The catheter was visualized in the right atrial cavity in 90 patients. CXR exams revealed catheter misplacement in seven cases. Eight patients with catheter misplacement underwent the same procedure in the other arm. In two patients, PICC placement failed due to anatomical reasons. Catheter misplacement was detected using TTE with sensitivity, specificity, positive predictive value, and negative predictive value of 97% confidence interval (CI; 91.31%–99.36%), 90% CI (55.50%–99.75%), 99%, and 75%, respectively. Conclusions: TTE is a reliable tool for detecting catheter misplacement and optimizing catheter tip positioning during PICC placement.
5.Treatment Outcomes after Discontinuation of Ethambutol due to Adverse Events in Mycobacterium avium Complex Lung Disease
Yong Shik KWON ; Byoung Soo KWON ; Ock hwa KIM ; Yea Eun PARK ; Tae Sun SHIM ; Yong Pil CHONG ; Kyung Wook JO
Journal of Korean Medical Science 2020;35(9):e59-
BACKGROUND:
Long-term administration of ethambutol (EMB) for Mycobacterium avium complex lung disease (MAC-LD) sometimes leads to permanent discontinuation of EMB due to various adverse events. This study aimed to investigate treatment outcomes after discontinuation of EMB.
METHODS:
Among patients diagnosed with MAC-LD between January 2001 and December 2014, 508 patients whose treatment was initiated with standard regimen until May 2018 were enrolled at a tertiary referral center in Korea. Of these 508 patients, 60 (11.8%) discontinued EMB due to various adverse effects. Among these 60 patients, treatment outcomes were analyzed for 44 patients by comparing their outcomes with those of matched subjects who received the standard treatment regimen without EMB discontinuation.
RESULTS:
The mean age of the 60 patients who discontinued EMB was 64.4 years. Ocular toxicity was the most common cause of discontinuation of EMB (75.0%, 45/60). The mean duration of EMB administration before its discontinuation was 7.0 ± 4.6 months. The treatment failure rate of the 44 patients with EMB discontinuation analyzed for treatment outcome was 29.6%, which was higher than that of the matched patients who received the standard regimen (18.3%), although the difference was not significant (P = 0.095). Of these 44 patients, EMB was substituted with later-generation fluoroquinolone in 23 patients, and the treatment failure rate of these 23 patients was significantly higher than that of the matched patients who received the standard regimen (39.1% vs. 19.3%, P = 0.045).
CONCLUSION
These findings suggest that treatment outcomes are unsatisfactory in patients with MAC-LD who discontinue EMB owing to adverse events. Notably, there was a statistically significant high failure rate in patients who were prescribed fluoroquinolone to replace EMB.
6.Treatment Outcomes after Discontinuation of Ethambutol due to Adverse Events in Mycobacterium avium Complex Lung Disease
Yong Shik KWON ; Byoung Soo KWON ; Ock hwa KIM ; Yea Eun PARK ; Tae Sun SHIM ; Yong Pil CHONG ; Kyung Wook JO
Journal of Korean Medical Science 2020;35(9):59-
BACKGROUND: Long-term administration of ethambutol (EMB) for Mycobacterium avium complex lung disease (MAC-LD) sometimes leads to permanent discontinuation of EMB due to various adverse events. This study aimed to investigate treatment outcomes after discontinuation of EMB.METHODS: Among patients diagnosed with MAC-LD between January 2001 and December 2014, 508 patients whose treatment was initiated with standard regimen until May 2018 were enrolled at a tertiary referral center in Korea. Of these 508 patients, 60 (11.8%) discontinued EMB due to various adverse effects. Among these 60 patients, treatment outcomes were analyzed for 44 patients by comparing their outcomes with those of matched subjects who received the standard treatment regimen without EMB discontinuation.RESULTS: The mean age of the 60 patients who discontinued EMB was 64.4 years. Ocular toxicity was the most common cause of discontinuation of EMB (75.0%, 45/60). The mean duration of EMB administration before its discontinuation was 7.0 ± 4.6 months. The treatment failure rate of the 44 patients with EMB discontinuation analyzed for treatment outcome was 29.6%, which was higher than that of the matched patients who received the standard regimen (18.3%), although the difference was not significant (P = 0.095). Of these 44 patients, EMB was substituted with later-generation fluoroquinolone in 23 patients, and the treatment failure rate of these 23 patients was significantly higher than that of the matched patients who received the standard regimen (39.1% vs. 19.3%, P = 0.045).CONCLUSION: These findings suggest that treatment outcomes are unsatisfactory in patients with MAC-LD who discontinue EMB owing to adverse events. Notably, there was a statistically significant high failure rate in patients who were prescribed fluoroquinolone to replace EMB.
Ethambutol
;
Fluoroquinolones
;
Humans
;
Korea
;
Lung Diseases
;
Mycobacterium avium Complex
;
Mycobacterium avium
;
Mycobacterium
;
Tertiary Care Centers
;
Treatment Failure
;
Treatment Outcome
7.Current Awareness and Use of the Strain Echocardiography in Routine Clinical Practices: Result of a Nationwide Survey in Korea.
Ju Hee LEE ; Jae Hyeong PARK ; Seung Woo PARK ; Woo Shik KIM ; Il Suk SOHN ; Jung Yeon CHIN ; Jung Sun CHO ; Ho Joong YOUN ; Hae Ok JUNG ; Sun Hwa LEE ; Seong Hwan KIM ; Wook Jin CHUNG ; Chi Young SHIM ; Jin Won JEONG ; Eui Young CHOI ; Se Joong RIM ; Jang Young KIM ; Kye Hun KIM ; Joon Han SHIN ; Dae Hee KIM ; Ung JEON ; Jung Hyun CHOI ; Yong Jin KIM ; Seung Jae JOO ; Ki Hong KIM ; Kyoung Im CHO ; Goo Yeong CHO
Journal of Cardiovascular Ultrasound 2017;25(3):91-97
BACKGROUND: Because conventional echocardiographic parameters have several limitations, strain echocardiography has often been introduced in clinical practice. However, there are also obstacles in using it in clinical practice. Therefore, we wanted to find the current status of awareness on using strain echocardiography in Korea. METHODS: We conducted a nationwide survey to evaluate current use and awareness of strain echocardiography from the members of the Korean Society of Echocardiography. RESULTS: We gathered total 321 questionnaires from 25 cardiology centers in Korea. All participants were able to perform or interpret echocardiographic examinations. All participating institutions performed strain echocardiography. Most of our study participants (97%) were aware of speckle tracking echocardiography and 185 (58%) performed it for clinical and research purposes. Two-dimensional strain echocardiography was the most commonly used modality and left ventricle (LV) was the most commonly used cardiac chamber (99%) for clinical purposes. Most of the participants (89%) did not think LV strain can replace LV ejection fraction (LVEF) in their clinical practice. The common reasons for not performing routine use of strain echocardiography was diversity of strain measurements and lack of normal reference value. Many participants had a favorable view of the future of strain echocardiography. CONCLUSION: Most of our study participants were aware of strain echocardiography, and all institutions performed strain echocardiography for clinical and research purposes. However, they did not think the LV strain values could replace LVEF. The diversity of strain measurements and lack of normal reference values were common reasons for not using strain echocardiography in clinical practice.
Cardiology
;
Echocardiography*
;
Heart Ventricles
;
Korea*
;
Reference Values
8.Normal 2-Dimensional Strain Values of the Left Ventricle: A Substudy of the Normal Echocardiographic Measurements in Korean Population Study.
Jae Hyeong PARK ; Ju Hee LEE ; Sang Yeub LEE ; Jin Oh CHOI ; Mi Seung SHIN ; Mi Jeong KIM ; Hae Ok JUNG ; Jeong Rang PARK ; Il Suk SOHN ; Hyungseop KIM ; Seong Mi PARK ; Nam Jin YOO ; Jung Hyun CHOI ; Hyung Kwan KIM ; Goo Yeong CHO ; Mi Rae LEE ; Jin Sun PARK ; Chi Young SHIM ; Dae Hee KIM ; Dae Hee SHIN ; Gil Ja SHIN ; Sung Hee SHIN ; Kye Hun KIM ; Woo Shik KIM ; Seung Woo PARK
Journal of Cardiovascular Ultrasound 2016;24(4):285-293
BACKGROUND: It is important to understand the distribution of 2-dimensional strain values in normal population. We performed a multicenter trial to measure normal echocardiographic values in the Korean population. METHODS: This was a substudy of the Normal echOcardiogRaphic Measurements in KoreAn popuLation (NORMAL) study. Echocardiographic specialists measured frequently used echocardiographic indices in healthy people according to a standardized method at 23 different university hospitals. The strain values were analyzed from digitally stored images. RESULTS: Of a total of 1003 healthy participants in NORMAL study, 2-dimensional strain values were measured in 501 subjects (265 females, mean age 47 ± 15 years old) with echocardiographic images only by GE echocardiographic machines. Interventricular septal thickness, left ventricular (LV) posterior wall thickness, systolic and diastolic LV dimensions, and LV ejection fraction were 7.5 ± 1.0 mm, 7.4 ± 1.0 mm, 29.9 ± 2.8 mm, 48.9 ± 3.6 mm, and 62 ± 4%, respectively. LV longitudinal systolic strain (LS) values of apical 4-chamber (A4C) view, apical 3-chamber (A3C) view, apical 2-chamber (A2C) view, and LV global LS (LVGLS) were −20.1 ± 2.3, −19.9 ± 2.7, −21.2 ± 2.6, and −20.4 ± 2.2%, respectively. LV longitudinal systolic strain rate (LVLSR) values of the A4C view, A3C view, A2C view, and LV global LSR (LVGLSR) were −1.18 ± 0.18, −1.20 ± 0.21, −1.25 ± 0.21, and −1.21 ± 0.21(−s), respectively. Females had lower LVGLS (−21.2 ± 2.2% vs. −19.5 ± 1.9%, p < 0.001) and LVGLSR (−1.25 ± 0.18(−s) vs. −1.17 ± 0.15(−s), p < 0.001) values than males. CONCLUSION: We measured LV longitudinal strain and strain rate values in the normal Korean population. Since considerable gender differences were observed, normal echocardiographic cutoff values should be differentially applied based on sex.
Echocardiography*
;
Female
;
Healthy Volunteers
;
Heart Ventricles*
;
Hospitals, University
;
Humans
;
Male
;
Methods
;
Multicenter Studies as Topic
;
Reference Values
;
Specialization
9.Normal Echocardiographic Measurements in a Korean Population Study: Part II. Doppler and Tissue Doppler Imaging.
Jin Oh CHOI ; Mi Seung SHIN ; Mi Jeong KIM ; Hae Ok JUNG ; Jeong Rang PARK ; Il Suk SOHN ; Hyungseop KIM ; Seong Mi PARK ; Nam Jin YOO ; Jung Hyun CHOI ; Hyung Kwan KIM ; Goo Yeong CHO ; Mi Rae LEE ; Jin Sun PARK ; Chi Young SHIM ; Dae Hee KIM ; Dae Hee SHIN ; Gil Ja SHIN ; Sung Hee SHIN ; Kye Hun KIM ; Jae Hyeong PARK ; Sang Yeub LEE ; Woo Shik KIM ; Seung Woo PARK
Journal of Cardiovascular Ultrasound 2016;24(2):144-152
BACKGROUND: Hemodynamic and functional evaluation with Doppler and tissue Doppler study as a part of comprehensive echocardiography is essential but normal reference values have never been reported from Korean normal population especially according to age and sex. METHODS: Using Normal echOcaRdiographic Measurements in a KoreAn popuLation study subjects, we obtained normal reference values for Doppler and tissue Doppler echocardiography including tricuspid annular velocities according to current guidelines and compared values according to gender and age groups. RESULTS: Mitral early diastolic (E) and late diastolic (A) velocity as well as E/A ratio were significantly higher in women compared to those in men. Conversely, mitral peak systolic and late diastolic annular velocity in both septal and lateral mitral annulus were significantly lower in women compared to those in men. However, there were no significant differences in both septal and lateral mitral early diastolic annular (e') velocity between men and women. In both men and women, mitral E velocity and its deceleration time as well as both E/A and E/e' ratio considerably increased with age. There were no significant differences in tricuspid inflow velocities and tricuspid lateral annular velocities between men and women except e' velocity, which was significantly higher in women compared to that in men. However, changes in both tricuspid inflow and lateral annular velocities according to age were similar to those in mitral velocities. CONCLUSION: Since there were significant differences in Doppler and tissue Doppler echocardiographic variables between men and women and changes according to age were even more considerable in both gender groups, normal Doppler echocardiographic values should be differentially applied based on age and sex.
Deceleration
;
Echocardiography*
;
Echocardiography, Doppler
;
Female
;
Hemodynamics
;
Humans
;
Male
;
Reference Values
10.Normal Echocardiographic Measurements in a Korean Population Study: Part I. Cardiac Chamber and Great Artery Evaluation.
Jin Oh CHOI ; Mi Seung SHIN ; Mi Jeong KIM ; Hae Ok JUNG ; Jeong Rang PARK ; Il Suk SOHN ; Hyungseop KIM ; Seong Mi PARK ; Nam Jin YOO ; Jung Hyun CHOI ; Hyung Kwan KIM ; Goo Yeong CHO ; Mi Rae LEE ; Jin Sun PARK ; Chi Young SHIM ; Dae Hee KIM ; Dae Hee SHIN ; Gil Ja SHIN ; Sung Hee SHIN ; Kye Hun KIM ; Jae Hyeong PARK ; Sang Yeub LEE ; Woo Shik KIM ; Seung Woo PARK
Journal of Cardiovascular Ultrasound 2015;23(3):158-172
BACKGROUND: Measurement of the cardiac chamber is essential, and current guidelines recommend measuring and reporting values for both sides of the cardiac chamber during echocardiographic evaluation. Normal echocardiographic reference values have been suggested previously, but detailed information about right-sided chambers and values according to gender was not included. METHODS: This is a prospective multicenter (23 centers) study evaluating normal Korean adult subjects using comprehensive echocardiography. We included normal adult subjects (age; 20-79 years old) who had no significant cardiac disorders or illnesses, such as hypertension or diabetes, which could affect cardiac structure and function. We measured the cardiac chamber including both right and left ventricles as well as atria according to current echocardiography guidelines and compared values according to gender and age groups. RESULTS: A total of 1003 subjects were evaluated and the mean age was 48 +/- 16 years. Left ventricular (LV) dimensions increased, but LV volume decreased in older subjects. Right ventricular (RV) area decreased in women and older subjects, and the RV long-axis dimension showed a similar trend. Left atrial (LA) volume increased in men but there were no differences in LA volume index between men and women. The dimension of great arteries increased in men and older subjects. CONCLUSION: Since there were considerable differences between men and women and in the different age groups, and the trends differed significantly between different echo variables, normal echocardiographic cutoff values should be differentially applied based on age and gender.
Adult
;
Arteries*
;
Echocardiography*
;
Female
;
Heart Ventricles
;
Humans
;
Hypertension
;
Male
;
Prospective Studies
;
Reference Values

Result Analysis