1.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
2.Measuring Medical Waste from Gastrointestinal Endoscopies in South Korea to Estimate Their Carbon Footprint
Da Hyun JUNG ; Hyun Jung LEE ; Tae Joo JEON ; Young Sin CHO ; Bo Ra KANG ; Nae Sun YOUN ; Jae Myung CHA
Gut and Liver 2025;19(1):43-49
Background/Aims:
Although gastrointestinal endoscopy (GIE) is a major contributor to the carbon footprint of national healthcare, the amount of medical waste generated by GIE procedures is not reported in South Korea. This study aimed to measure the amount of medical waste generated from GIE procedures in South Korea.
Methods:
We conducted a 5-day audit of medical waste generated during GIEs at seven hospitals. During the study period, medical waste in the endoscopy examination rooms was measured twice daily and documented as mass (kg). To calculate the mean mass of disposable waste generated during one esophagogastroduodenoscopy (EGD) and one colonoscopy, the mean mass of medical waste generated from seven examinations was calculated. The mean mass of medical waste generated during GIEs was calculated by dividing the total mass of medical waste generated by the number of GIE procedures.
Results:
Overall, 3,922 endoscopies were performed and 4,558 kg of waste was generated. The mean weight of medical waste generated per endoscopy was 1.34 kg. Each EGD and colonoscopy generated a mean of 0.24 kg and 0.43 kg of disposable waste, respectively. Applying the mean waste estimates from this study to annual GIE procedures performed in South Korea in 2022 showed that the total medical waste produced from GIE was 13,704,453 kg. In addition, the total masses of medical waste produced during EGD and colonoscopy procedures were 819,766 kg and 2,889,478 kg, respectively.
Conclusions
Our quantitative measurement showed that a large amount of medical waste is generated from GIE procedures. However, further research is warranted to reduce medical waste generated during GIE, which is an urgent unmet need.
3.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
4.Measuring Medical Waste from Gastrointestinal Endoscopies in South Korea to Estimate Their Carbon Footprint
Da Hyun JUNG ; Hyun Jung LEE ; Tae Joo JEON ; Young Sin CHO ; Bo Ra KANG ; Nae Sun YOUN ; Jae Myung CHA
Gut and Liver 2025;19(1):43-49
Background/Aims:
Although gastrointestinal endoscopy (GIE) is a major contributor to the carbon footprint of national healthcare, the amount of medical waste generated by GIE procedures is not reported in South Korea. This study aimed to measure the amount of medical waste generated from GIE procedures in South Korea.
Methods:
We conducted a 5-day audit of medical waste generated during GIEs at seven hospitals. During the study period, medical waste in the endoscopy examination rooms was measured twice daily and documented as mass (kg). To calculate the mean mass of disposable waste generated during one esophagogastroduodenoscopy (EGD) and one colonoscopy, the mean mass of medical waste generated from seven examinations was calculated. The mean mass of medical waste generated during GIEs was calculated by dividing the total mass of medical waste generated by the number of GIE procedures.
Results:
Overall, 3,922 endoscopies were performed and 4,558 kg of waste was generated. The mean weight of medical waste generated per endoscopy was 1.34 kg. Each EGD and colonoscopy generated a mean of 0.24 kg and 0.43 kg of disposable waste, respectively. Applying the mean waste estimates from this study to annual GIE procedures performed in South Korea in 2022 showed that the total medical waste produced from GIE was 13,704,453 kg. In addition, the total masses of medical waste produced during EGD and colonoscopy procedures were 819,766 kg and 2,889,478 kg, respectively.
Conclusions
Our quantitative measurement showed that a large amount of medical waste is generated from GIE procedures. However, further research is warranted to reduce medical waste generated during GIE, which is an urgent unmet need.
5.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
6.Measuring Medical Waste from Gastrointestinal Endoscopies in South Korea to Estimate Their Carbon Footprint
Da Hyun JUNG ; Hyun Jung LEE ; Tae Joo JEON ; Young Sin CHO ; Bo Ra KANG ; Nae Sun YOUN ; Jae Myung CHA
Gut and Liver 2025;19(1):43-49
Background/Aims:
Although gastrointestinal endoscopy (GIE) is a major contributor to the carbon footprint of national healthcare, the amount of medical waste generated by GIE procedures is not reported in South Korea. This study aimed to measure the amount of medical waste generated from GIE procedures in South Korea.
Methods:
We conducted a 5-day audit of medical waste generated during GIEs at seven hospitals. During the study period, medical waste in the endoscopy examination rooms was measured twice daily and documented as mass (kg). To calculate the mean mass of disposable waste generated during one esophagogastroduodenoscopy (EGD) and one colonoscopy, the mean mass of medical waste generated from seven examinations was calculated. The mean mass of medical waste generated during GIEs was calculated by dividing the total mass of medical waste generated by the number of GIE procedures.
Results:
Overall, 3,922 endoscopies were performed and 4,558 kg of waste was generated. The mean weight of medical waste generated per endoscopy was 1.34 kg. Each EGD and colonoscopy generated a mean of 0.24 kg and 0.43 kg of disposable waste, respectively. Applying the mean waste estimates from this study to annual GIE procedures performed in South Korea in 2022 showed that the total medical waste produced from GIE was 13,704,453 kg. In addition, the total masses of medical waste produced during EGD and colonoscopy procedures were 819,766 kg and 2,889,478 kg, respectively.
Conclusions
Our quantitative measurement showed that a large amount of medical waste is generated from GIE procedures. However, further research is warranted to reduce medical waste generated during GIE, which is an urgent unmet need.
7.Short-term Efficacy and Safety of Latanoprostene Bunod Therapy for Patients with Primary Open-angle Glaucoma
Journal of the Korean Ophthalmological Society 2025;66(2):114-119
Purpose:
To evaluate the short-term efficacy and safety of latanoprostene bunod 0.024% in patients with primary open-angle glaucoma.
Methods:
A retrospective study was conducted from September 2022 to September 2023, involving 29 eyes from patients diagnosed with primary open-angle glaucoma. The study analyzed the intraocular pressure (IOP)-lowering effects of latanoprostene bunod 0.024% at 1 and 3 months after administration. Additionally, adverse events reported by patients at each visit were documented.
Results:
The mean age of patients at the start of treatment was 64.46 years. The baseline IOP was 17.46 ± 4.03 mmHg, which significantly decreased to 15.07 ± 4.23 mmHg (p = 0.002) at 1 month (29 eyes) and 14.93 ± 3.86 mmHg (p = 0.002) at 3 months (28 eyes) after latanoprostene bunod administration. After 1 month, 9 patients reported adverse events, including conjunctival hyperemia (1 eye, 3.5%), itching (2 eyes, 6.9%), foreign body sensation (2 eyes, 6.9%), stinging (2 eyes, 6.9%), ocular pain (2 eyes, 6.9%), and deepening of the upper eyelid sulcus (1 eye, 3.5%). The patient who experienced deepening of the upper eyelid sulcus discontinued treatment. After 3 months, 2 eyes with itching discontinued treatment due to conjunctival allergy.
Conclusions
Latanoprostene bunod 0.024% demonstrated short-term efficacy in reducing IOP and a manageable safety profile in patients with primary open-angle glaucoma.
8.Short-term Efficacy and Safety of Latanoprostene Bunod Therapy for Patients with Primary Open-angle Glaucoma
Journal of the Korean Ophthalmological Society 2025;66(2):114-119
Purpose:
To evaluate the short-term efficacy and safety of latanoprostene bunod 0.024% in patients with primary open-angle glaucoma.
Methods:
A retrospective study was conducted from September 2022 to September 2023, involving 29 eyes from patients diagnosed with primary open-angle glaucoma. The study analyzed the intraocular pressure (IOP)-lowering effects of latanoprostene bunod 0.024% at 1 and 3 months after administration. Additionally, adverse events reported by patients at each visit were documented.
Results:
The mean age of patients at the start of treatment was 64.46 years. The baseline IOP was 17.46 ± 4.03 mmHg, which significantly decreased to 15.07 ± 4.23 mmHg (p = 0.002) at 1 month (29 eyes) and 14.93 ± 3.86 mmHg (p = 0.002) at 3 months (28 eyes) after latanoprostene bunod administration. After 1 month, 9 patients reported adverse events, including conjunctival hyperemia (1 eye, 3.5%), itching (2 eyes, 6.9%), foreign body sensation (2 eyes, 6.9%), stinging (2 eyes, 6.9%), ocular pain (2 eyes, 6.9%), and deepening of the upper eyelid sulcus (1 eye, 3.5%). The patient who experienced deepening of the upper eyelid sulcus discontinued treatment. After 3 months, 2 eyes with itching discontinued treatment due to conjunctival allergy.
Conclusions
Latanoprostene bunod 0.024% demonstrated short-term efficacy in reducing IOP and a manageable safety profile in patients with primary open-angle glaucoma.
9.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
10.Measuring Medical Waste from Gastrointestinal Endoscopies in South Korea to Estimate Their Carbon Footprint
Da Hyun JUNG ; Hyun Jung LEE ; Tae Joo JEON ; Young Sin CHO ; Bo Ra KANG ; Nae Sun YOUN ; Jae Myung CHA
Gut and Liver 2025;19(1):43-49
Background/Aims:
Although gastrointestinal endoscopy (GIE) is a major contributor to the carbon footprint of national healthcare, the amount of medical waste generated by GIE procedures is not reported in South Korea. This study aimed to measure the amount of medical waste generated from GIE procedures in South Korea.
Methods:
We conducted a 5-day audit of medical waste generated during GIEs at seven hospitals. During the study period, medical waste in the endoscopy examination rooms was measured twice daily and documented as mass (kg). To calculate the mean mass of disposable waste generated during one esophagogastroduodenoscopy (EGD) and one colonoscopy, the mean mass of medical waste generated from seven examinations was calculated. The mean mass of medical waste generated during GIEs was calculated by dividing the total mass of medical waste generated by the number of GIE procedures.
Results:
Overall, 3,922 endoscopies were performed and 4,558 kg of waste was generated. The mean weight of medical waste generated per endoscopy was 1.34 kg. Each EGD and colonoscopy generated a mean of 0.24 kg and 0.43 kg of disposable waste, respectively. Applying the mean waste estimates from this study to annual GIE procedures performed in South Korea in 2022 showed that the total medical waste produced from GIE was 13,704,453 kg. In addition, the total masses of medical waste produced during EGD and colonoscopy procedures were 819,766 kg and 2,889,478 kg, respectively.
Conclusions
Our quantitative measurement showed that a large amount of medical waste is generated from GIE procedures. However, further research is warranted to reduce medical waste generated during GIE, which is an urgent unmet need.

Result Analysis
Print
Save
E-mail