1.Association of Intensive Endoscopic Burden with Esophageal Cancer Detection: A Nationwide Cohort Study
Yeunji LEE ; Eunyoung LEE ; Bumhee PARK ; Gil Ho LEE ; Sun Gyo LIM ; Sung Jae SHIN ; Choong-Kyun NOH ; Kee Myung LEE
Gut and Liver 2025;19(1):59-68
Background/Aims:
Early diagnosis of esophageal cancer (EC) remains challenging despite the increasing frequency of endoscopic screenings globally. The rapidly increasing number of endoscopic screenings performed over a certain period might influence diagnostic performance. This study evaluated the association between the number of endoscopic screenings and EC detection rates in a nationwide cohort.
Methods:
This retrospective population-based study used the Korean National Cancer Screening Program database, comprising 32,774,742 males and females aged ≥40 years between 2015and 2019. Negative binomial regression model and least-squares mean evaluation were used to assess the association between month of the year and EC detection rates.
Results:
This study enrolled 28,032,590 participants who underwent upper endoscopy. The number of participants in the fourth quarter (October to December: 10,923,142 [39.0%]) was 2.1 times higher than that in the first quarter (January to March: 5,085,087 [18.1%]); this trend continued for all 5 years. Contrarily, detection rates for EC in the fourth quarter (0.08/1,000 person) were half that in the first quarter (0.15/1,000 person). The odds of detecting EC were lowest in November; in 2015 the odds were 0.57 (95% confidence interval, 0.41 to 0.79; p=0.001) times lower and in 2016, they were 0.51 (95% confidence interval, 0.37 to 0.68; p<0.001) times lower compared to January. The predicted detection rates showed a decreasing trend toward the end of the year (p>0.05 for all).
Conclusions
The workload of endoscopists increased excessively with the rising number of endoscopies toward the end of the year, which was reflected by the decreased EC detection rates during this period.
2.The Potential Role of the Rapid Urease Test with the Sweeping Method in the Gray Zone of the Urea Breath Test after Helicobacter pylori Eradication
Ji Hyun KIM ; Ji Min KIM ; Bumhee PARK ; Sun Gyo LIM ; Sung Jae SHIN ; Kee Myung LEE ; Gil Ho LEE ; Choong-Kyun NOH
Gut and Liver 2025;19(3):355-363
Background/Aims:
Although the urea breath test (UBT) is widely used as a representative monitoring test after Helicobacter pylori eradication, false-negative results can occur because of the gray zone related to its cutoff value. This study aimed to compare the diagnostic performances of the rapid urease test (RUT), the RUT with sweeping method, and the UBT, and to investigate the role of the sweeping method in the gray zone of UBT values.
Methods:
We retrospectively reviewed 216 patients who received standard first-line H. pylori eradication treatments (n=216). All participants underwent to testing using the sweeping method and UBT on the same day. The sensitivity, specificity, and accuracy were analyzed to compare the two methods.
Results:
The sensitivity (0.537 vs 0.806, p=0.002) and accuracy (0.843 vs 0.870, p=0.026) of the UBT were inferior to those of the sweeping method. A total of 31 individuals tested positive for H. pylori according to the UBT, whereas 54 individuals tested positive according to the sweeping method. In the group for which the gold standard definition indicated H. pylori positivity but UBT results were negative (n=31), all individuals had a UBT value under 2.5‰. In the multivariate logistic regression model, a UBT value of 1.4‰ to 2.5‰ increased the risk of false-negative results by 6.5 times (odds ratio, 6.5; 95% confidence interval, 2.077 to 20.288; p=0.001).
Conclusions
After H. pylori eradication, false-negative results can occur for individuals undergoing the UBT, primarily for values below the UBT cutoff. The RUT with the sweeping method can potentially help detect H. pylori in the gray zone of the UBT, improving diagnostic accuracy.
3.Association of Intensive Endoscopic Burden with Esophageal Cancer Detection: A Nationwide Cohort Study
Yeunji LEE ; Eunyoung LEE ; Bumhee PARK ; Gil Ho LEE ; Sun Gyo LIM ; Sung Jae SHIN ; Choong-Kyun NOH ; Kee Myung LEE
Gut and Liver 2025;19(1):59-68
Background/Aims:
Early diagnosis of esophageal cancer (EC) remains challenging despite the increasing frequency of endoscopic screenings globally. The rapidly increasing number of endoscopic screenings performed over a certain period might influence diagnostic performance. This study evaluated the association between the number of endoscopic screenings and EC detection rates in a nationwide cohort.
Methods:
This retrospective population-based study used the Korean National Cancer Screening Program database, comprising 32,774,742 males and females aged ≥40 years between 2015and 2019. Negative binomial regression model and least-squares mean evaluation were used to assess the association between month of the year and EC detection rates.
Results:
This study enrolled 28,032,590 participants who underwent upper endoscopy. The number of participants in the fourth quarter (October to December: 10,923,142 [39.0%]) was 2.1 times higher than that in the first quarter (January to March: 5,085,087 [18.1%]); this trend continued for all 5 years. Contrarily, detection rates for EC in the fourth quarter (0.08/1,000 person) were half that in the first quarter (0.15/1,000 person). The odds of detecting EC were lowest in November; in 2015 the odds were 0.57 (95% confidence interval, 0.41 to 0.79; p=0.001) times lower and in 2016, they were 0.51 (95% confidence interval, 0.37 to 0.68; p<0.001) times lower compared to January. The predicted detection rates showed a decreasing trend toward the end of the year (p>0.05 for all).
Conclusions
The workload of endoscopists increased excessively with the rising number of endoscopies toward the end of the year, which was reflected by the decreased EC detection rates during this period.
4.The Potential Role of the Rapid Urease Test with the Sweeping Method in the Gray Zone of the Urea Breath Test after Helicobacter pylori Eradication
Ji Hyun KIM ; Ji Min KIM ; Bumhee PARK ; Sun Gyo LIM ; Sung Jae SHIN ; Kee Myung LEE ; Gil Ho LEE ; Choong-Kyun NOH
Gut and Liver 2025;19(3):355-363
Background/Aims:
Although the urea breath test (UBT) is widely used as a representative monitoring test after Helicobacter pylori eradication, false-negative results can occur because of the gray zone related to its cutoff value. This study aimed to compare the diagnostic performances of the rapid urease test (RUT), the RUT with sweeping method, and the UBT, and to investigate the role of the sweeping method in the gray zone of UBT values.
Methods:
We retrospectively reviewed 216 patients who received standard first-line H. pylori eradication treatments (n=216). All participants underwent to testing using the sweeping method and UBT on the same day. The sensitivity, specificity, and accuracy were analyzed to compare the two methods.
Results:
The sensitivity (0.537 vs 0.806, p=0.002) and accuracy (0.843 vs 0.870, p=0.026) of the UBT were inferior to those of the sweeping method. A total of 31 individuals tested positive for H. pylori according to the UBT, whereas 54 individuals tested positive according to the sweeping method. In the group for which the gold standard definition indicated H. pylori positivity but UBT results were negative (n=31), all individuals had a UBT value under 2.5‰. In the multivariate logistic regression model, a UBT value of 1.4‰ to 2.5‰ increased the risk of false-negative results by 6.5 times (odds ratio, 6.5; 95% confidence interval, 2.077 to 20.288; p=0.001).
Conclusions
After H. pylori eradication, false-negative results can occur for individuals undergoing the UBT, primarily for values below the UBT cutoff. The RUT with the sweeping method can potentially help detect H. pylori in the gray zone of the UBT, improving diagnostic accuracy.
5.Association of Intensive Endoscopic Burden with Esophageal Cancer Detection: A Nationwide Cohort Study
Yeunji LEE ; Eunyoung LEE ; Bumhee PARK ; Gil Ho LEE ; Sun Gyo LIM ; Sung Jae SHIN ; Choong-Kyun NOH ; Kee Myung LEE
Gut and Liver 2025;19(1):59-68
Background/Aims:
Early diagnosis of esophageal cancer (EC) remains challenging despite the increasing frequency of endoscopic screenings globally. The rapidly increasing number of endoscopic screenings performed over a certain period might influence diagnostic performance. This study evaluated the association between the number of endoscopic screenings and EC detection rates in a nationwide cohort.
Methods:
This retrospective population-based study used the Korean National Cancer Screening Program database, comprising 32,774,742 males and females aged ≥40 years between 2015and 2019. Negative binomial regression model and least-squares mean evaluation were used to assess the association between month of the year and EC detection rates.
Results:
This study enrolled 28,032,590 participants who underwent upper endoscopy. The number of participants in the fourth quarter (October to December: 10,923,142 [39.0%]) was 2.1 times higher than that in the first quarter (January to March: 5,085,087 [18.1%]); this trend continued for all 5 years. Contrarily, detection rates for EC in the fourth quarter (0.08/1,000 person) were half that in the first quarter (0.15/1,000 person). The odds of detecting EC were lowest in November; in 2015 the odds were 0.57 (95% confidence interval, 0.41 to 0.79; p=0.001) times lower and in 2016, they were 0.51 (95% confidence interval, 0.37 to 0.68; p<0.001) times lower compared to January. The predicted detection rates showed a decreasing trend toward the end of the year (p>0.05 for all).
Conclusions
The workload of endoscopists increased excessively with the rising number of endoscopies toward the end of the year, which was reflected by the decreased EC detection rates during this period.
6.The Potential Role of the Rapid Urease Test with the Sweeping Method in the Gray Zone of the Urea Breath Test after Helicobacter pylori Eradication
Ji Hyun KIM ; Ji Min KIM ; Bumhee PARK ; Sun Gyo LIM ; Sung Jae SHIN ; Kee Myung LEE ; Gil Ho LEE ; Choong-Kyun NOH
Gut and Liver 2025;19(3):355-363
Background/Aims:
Although the urea breath test (UBT) is widely used as a representative monitoring test after Helicobacter pylori eradication, false-negative results can occur because of the gray zone related to its cutoff value. This study aimed to compare the diagnostic performances of the rapid urease test (RUT), the RUT with sweeping method, and the UBT, and to investigate the role of the sweeping method in the gray zone of UBT values.
Methods:
We retrospectively reviewed 216 patients who received standard first-line H. pylori eradication treatments (n=216). All participants underwent to testing using the sweeping method and UBT on the same day. The sensitivity, specificity, and accuracy were analyzed to compare the two methods.
Results:
The sensitivity (0.537 vs 0.806, p=0.002) and accuracy (0.843 vs 0.870, p=0.026) of the UBT were inferior to those of the sweeping method. A total of 31 individuals tested positive for H. pylori according to the UBT, whereas 54 individuals tested positive according to the sweeping method. In the group for which the gold standard definition indicated H. pylori positivity but UBT results were negative (n=31), all individuals had a UBT value under 2.5‰. In the multivariate logistic regression model, a UBT value of 1.4‰ to 2.5‰ increased the risk of false-negative results by 6.5 times (odds ratio, 6.5; 95% confidence interval, 2.077 to 20.288; p=0.001).
Conclusions
After H. pylori eradication, false-negative results can occur for individuals undergoing the UBT, primarily for values below the UBT cutoff. The RUT with the sweeping method can potentially help detect H. pylori in the gray zone of the UBT, improving diagnostic accuracy.
7.Association of Intensive Endoscopic Burden with Esophageal Cancer Detection: A Nationwide Cohort Study
Yeunji LEE ; Eunyoung LEE ; Bumhee PARK ; Gil Ho LEE ; Sun Gyo LIM ; Sung Jae SHIN ; Choong-Kyun NOH ; Kee Myung LEE
Gut and Liver 2025;19(1):59-68
Background/Aims:
Early diagnosis of esophageal cancer (EC) remains challenging despite the increasing frequency of endoscopic screenings globally. The rapidly increasing number of endoscopic screenings performed over a certain period might influence diagnostic performance. This study evaluated the association between the number of endoscopic screenings and EC detection rates in a nationwide cohort.
Methods:
This retrospective population-based study used the Korean National Cancer Screening Program database, comprising 32,774,742 males and females aged ≥40 years between 2015and 2019. Negative binomial regression model and least-squares mean evaluation were used to assess the association between month of the year and EC detection rates.
Results:
This study enrolled 28,032,590 participants who underwent upper endoscopy. The number of participants in the fourth quarter (October to December: 10,923,142 [39.0%]) was 2.1 times higher than that in the first quarter (January to March: 5,085,087 [18.1%]); this trend continued for all 5 years. Contrarily, detection rates for EC in the fourth quarter (0.08/1,000 person) were half that in the first quarter (0.15/1,000 person). The odds of detecting EC were lowest in November; in 2015 the odds were 0.57 (95% confidence interval, 0.41 to 0.79; p=0.001) times lower and in 2016, they were 0.51 (95% confidence interval, 0.37 to 0.68; p<0.001) times lower compared to January. The predicted detection rates showed a decreasing trend toward the end of the year (p>0.05 for all).
Conclusions
The workload of endoscopists increased excessively with the rising number of endoscopies toward the end of the year, which was reflected by the decreased EC detection rates during this period.
8.The Potential Role of the Rapid Urease Test with the Sweeping Method in the Gray Zone of the Urea Breath Test after Helicobacter pylori Eradication
Ji Hyun KIM ; Ji Min KIM ; Bumhee PARK ; Sun Gyo LIM ; Sung Jae SHIN ; Kee Myung LEE ; Gil Ho LEE ; Choong-Kyun NOH
Gut and Liver 2025;19(3):355-363
Background/Aims:
Although the urea breath test (UBT) is widely used as a representative monitoring test after Helicobacter pylori eradication, false-negative results can occur because of the gray zone related to its cutoff value. This study aimed to compare the diagnostic performances of the rapid urease test (RUT), the RUT with sweeping method, and the UBT, and to investigate the role of the sweeping method in the gray zone of UBT values.
Methods:
We retrospectively reviewed 216 patients who received standard first-line H. pylori eradication treatments (n=216). All participants underwent to testing using the sweeping method and UBT on the same day. The sensitivity, specificity, and accuracy were analyzed to compare the two methods.
Results:
The sensitivity (0.537 vs 0.806, p=0.002) and accuracy (0.843 vs 0.870, p=0.026) of the UBT were inferior to those of the sweeping method. A total of 31 individuals tested positive for H. pylori according to the UBT, whereas 54 individuals tested positive according to the sweeping method. In the group for which the gold standard definition indicated H. pylori positivity but UBT results were negative (n=31), all individuals had a UBT value under 2.5‰. In the multivariate logistic regression model, a UBT value of 1.4‰ to 2.5‰ increased the risk of false-negative results by 6.5 times (odds ratio, 6.5; 95% confidence interval, 2.077 to 20.288; p=0.001).
Conclusions
After H. pylori eradication, false-negative results can occur for individuals undergoing the UBT, primarily for values below the UBT cutoff. The RUT with the sweeping method can potentially help detect H. pylori in the gray zone of the UBT, improving diagnostic accuracy.
9.A Study of the Molecular Characteristics of the Serologic D-- Blood Type in Korean Blood Donors
Insoon JANG ; A Hyun LIM ; An Gyo LEE ; Sun-Mi SHIN ; Kyoung Won YOUN ; Jaehyun KIM ; Hwang Min KIM ; Yeongbin KIM
Korean Journal of Blood Transfusion 2023;34(2):92-107
Background:
The Korean Red Cross has conducted serologic tests for C, c, E, e antigens and found 18 D-- donors.In this study, we performed RHCE genotyping to identify the molecular characteristics of the serologic D-- blood type in Korean blood donors.
Methods:
We performed RHCE-specific PCR-based electrophoresis to check the amplification pattern of each exon.Sanger sequencing was conducted to find the variants in the nucleotide sequence. We determined the RHCE genotype based on the electrophoresis and Sanger sequencing results.
Results:
Total eight out of 18 D-- donors were participated in this research. In the PCR-based electrophoresis tests, RHCE exons 3, 4, and 6 were not amplified in samples #4, #6, and #8. Also, sample #2 showed an abnormal band pattern of RHCE exon 9. The Sanger sequencing results showed that the nucleotide sequences of the RHCE exons 5, 7, and 8 in samples #4, #6 and #8 corresponded to the nucleotide sequences of RHD exons 5, 7, and 8, respectively, suggesting the possibility of a RHCE-RHD(3-8)-RHCE hybrid allele. The nucleotide sequences of RHCE exons 7 and 8 in sample #2 were the same as the nucleotide sequences of RHD exons 7 and 8, respectively.In samples #1, #3, #5, and #7, no specific variants known to cause D-- phenotype were found.
Conclusion
RHCE genes partially replaced by the RHD genes were found in four out of eight participants and three of them were identified as ?RHCE*02N.07, which is known as the RHCE null allele. A further study with complete RHCE sequencing could be helpful for an understanding of the molecular mechanisms of samples in which no significant variants were identified.
10.Elucidating the characteristics of Mx1 and resistance to influenza A virus subtype H1N1 in the newly developed KWM/Hym mice
Hajin NAM ; Boyoung KIM ; Avishekh GAUTAM ; Yoo Yeon KIM ; Eun Sun PARK ; Jong Sun LEE ; Hyung-Joo KWON ; Je Kyung SEONG ; Jun Gyo SUH
Laboratory Animal Research 2022;38(3):219-225
Background:
Inbred mice have several advantages, including genetic similarity to humans, a well-established gene manipulation system, and strong tolerance to inbreeding. However, inbred mice derived from a limited genetic pool have a small genetic diversity. Thus, the development of new inbred strains from wild mice is needed to overcome this limitation. Hence, in this study, we used a new strain of inbred mice called KWM/Hym. We sequenced the Mx1 gene to elucidate the genetic diversities of KWM/Hym mice and observed the biological alterations of the Mx1 protein upon influenza A infection.
Results:
The Mx1 gene in KWM/Hym mice had 2, 4, and 38 nucleotide substitutions compared to those in the Mx1 gene in A2G, CAST/EiJ, and Mus spretus mice, respectively. Moreover, the Mx1 protein in KWM/Hym mice had 2 and 25 amino acid substitutions compared to those in the Mx1 protein in CAST/EiJ and M. spretus mice, respectively. To elucidate the function of the Mx1 protein, we inoculated the influenza A virus (A/WSN/1933) in KWM/Hym mice. Nine days after infection, all infected KWM/Hym mice survived without any weight loss. Four days after infection, the lungs of the infected KWM/Hym mice showed mild alveolitis and loss of bronchiolar epithelium; however, the pulmonary viral titers of the infected KWM/Hym mice were significantly lower than that in the infected BALB/c mice (2.17 × plaqueforming units mL −1 ).
Conclusions
Our results demonstrate that the KWM/Hym mice are resistant to influenza A virus infection. Further, these mice can be used as a model organism to understand the mechanism of influenza A virus susceptibility.

Result Analysis
Print
Save
E-mail