1.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
2.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.
3.Effect of ELHLD peptide for stifle function recovery after tibial plateau leveling osteotomy in dogs
Journal of Veterinary Science 2025;26(1):e6-
Objective:
This study aimed to investigate the impact of intraoperative intra-articular injection of the ELHLD peptide (L-glutamyl-L-leucyl-L-histidyl-L-leucyl-L-aspartic acid) on postoperative stifle function in patients with medial patella luxation grade 3 and osteoarthritis grade 2 undergoing tibial plateau leveling osteotomy due to anterior cruciate ligament (ACL) rupture.
Methods:
A total of 12 dogs participated, with 6 dogs assigned to the control group and 6 to the ELHLD peptide treatment group. The ELHLD peptide was administered by intra-articular injection to patients, and the following aspects were compared with the control: hindlimb circumference, balance evaluation score (BES), muscle mass, and stifle function score (SFS).These assessments were conducted at 2, 4, 8, and 12 weeks after surgery.
Results:
In the treatment group, hindlimb circumference suggested an effect on the recovery stifle function at the 4th and 8th week (p < 0.05) after surgery, and the BES and muscle mass test were effective at 4th week (p < 0.05). In the SFS test, it was effective at 2nd week (p < 0.05).
Conclusions
and Relevance: The use of ELHLD injections is meaningful in that it helps rapid recovery of joint function in the early stages after surgery. This research might improve the satisfaction of the caregiver, and facilitate the overall recovery process in the patient.
4.Carnitine Metabolite as a Potential Circulating Biomarker for Sarcopenia in Men
Je Hyun SEO ; Jung-Min KOH ; Han Jin CHO ; Hanjun KIM ; Young‑Sun LEE ; Su Jung KIM ; Pil Whan YOON ; Won KIM ; Sung Jin BAE ; Hong-Kyu KIM ; Hyun Ju YOO ; Seung Hun LEE
Endocrinology and Metabolism 2025;40(1):93-102
Background:
Sarcopenia, a multifactorial disorder involving metabolic disturbance, suggests potential for metabolite biomarkers. Carnitine (CN), essential for skeletal muscle energy metabolism, may be a candidate biomarker. We investigated whether CN metabolites are biomarkers for sarcopenia.
Methods:
Associations between the CN metabolites identified from an animal model of sarcopenia and muscle cells and sarcopenia status were evaluated in men from an age-matched discovery (72 cases, 72 controls) and a validation (21 cases, 47 controls) cohort.
Results:
An association between CN metabolites and sarcopenia showed in mouse and cell studies. In the discovery cohort, plasma C5-CN levels were lower in sarcopenic men (P=0.005). C5-CN levels in men tended to be associated with handgrip strength (HGS) (P=0.098) and were significantly associated with skeletal muscle mass (P=0.003). Each standard deviation increase in C5-CN levels reduced the odds of low muscle mass (odd ratio, 0.61; 95% confidence interval [CI], 0.42 to 0.89). The area under the receiver operating characteristic curve (AUROC) of CN score using a regression equation of C5-CN levels, for sarcopenia was 0.635 (95% CI, 0.544 to 0.726). In the discovery cohort, addition of CN score to HGS significantly improved AUROC from 0.646 (95% CI, 0.575 to 0.717; HGS only) to 0.727 (95% CI, 0.643 to 0.810; P=0.006; HGS+CN score). The improvement was confirmed in the validation cohort (AUROC=0.563; 95% CI, 0.470 to 0.656 for HGS; and AUROC=0.712; 95% CI, 0.569 to 0.855 for HGS+CN score; P=0.027).
Conclusion
C5-CN, indicative of low muscle mass, is a potential circulating biomarker for sarcopenia in men. Further studies are required to confirm these results and explore sarcopenia-related metabolomic changes.
5.Atypical features of hepatic veno‑occlusive disease/sinusoidal obstruction syndrome after inotuzumab ozogamicin in adult patients with acute lymphoblastic leukemia
Kyung‑Hun SUNG ; Daehun KWAG ; Gi June MIN ; Sung‑Soo PARK ; Silvia PARK ; Sung‑Eun LEE ; Byung‑Sik CHO ; Ki‑Seong EOM ; Yoo‑Jin KIM ; Hee‑Je KIM ; Chang‑Ki MIN ; Seok‑Goo CHO ; Seok LEE ; Jae‑Ho YOON
Blood Research 2025;60():28-
Purpose:
Inotuzumab ozogamicin (INO) has demonstrated a safe bridging role to allogeneic hematopoietic stem cell transplantation (HSCT) in patients with relapsed or refractory B-cell acute lymphoblastic leukemia (R/R B-ALL). How‑ ever, hepatic veno-occlusive disease/sinusoidal obstruction syndrome (VOD/SOS) is frequently observed. This study aimed to identify significant features of INO-associated VOD/SOS.
Methods:
We reviewed seven cases of hepatic VOD/SOS that developed either during INO salvage or after alloge‑ neic HSCT following INO-induced complete remission (CR). Diagnosis and severity grading of VOD/SOS were based on the revised criteria from the European Society for Blood and Marrow Transplantation. Defibrotide was used to treat severe to very severe cases.
Results:
Four patients developed VOD/SOS during INO salvage therapy (at 21 and 36 days post-INO1, 77 days postINO3, and 21 days post-INO5), while three were diagnosed at 2, 5, and 10 days post-HSCT following INO-induced CR.Doppler ultrasonography revealed preserved portal vein flow (range 10.2–26.0 cm/sec) and normal hepatic artery resistive index (RI, range 0.56–0.74) in all but one patient (RI 0.83). Despite this, all patients presented with massive ascites and progressively elevated total bilirubin levels. All cases were classified as severe to very severe; six were treated with defibrotide and one underwent liver transplantation. Most patients ultimately died owing to VOD/SOS progression.
Conclusion
Post-INO VOD/SOS manifested as two different clinical settings and was characterized by preserved portal vein flow, which complicated diagnosis. Despite timely defibrotide administration, clinical outcomes were poor.These findings emphasize the need for vigilance and potential consideration of prophylactic strategies for prevention of INO-associated VOD/SOS.
6.Harnessing Institutionally Developed Clinical Targeted Sequencing to Improve Patient Survival in Breast Cancer: A Seven-Year Experience
Jiwon KOH ; Jinyong KIM ; Go-Un WOO ; Hanbaek YI ; So Yean KWON ; Jeongmin SEO ; Jeong Mo BAE ; Jung Ho KIM ; Jae Kyung WON ; Han Suk RYU ; Yoon Kyung JEON ; Dae-Won LEE ; Miso KIM ; Tae-Yong KIM ; Kyung-Hun LEE ; Tae-You KIM ; Jee-Soo LEE ; Moon-Woo SEONG ; Sheehyun KIM ; Sungyoung LEE ; Hongseok YUN ; Myung Geun SONG ; Jaeyong CHOI ; Jong-Il KIM ; Seock-Ah IM
Cancer Research and Treatment 2025;57(2):443-456
Purpose:
Considering the high disease burden and unique features of Asian patients with breast cancer (BC), it is essential to have a comprehensive view of genetic characteristics in this population. An institutional targeted sequencing platform was developed through the Korea Research-Driven Hospitals project and was incorporated into clinical practice. This study explores the use of targeted next-generation sequencing (NGS) and its outcomes in patients with advanced/metastatic BC in the real world.
Materials and Methods:
We reviewed the results of NGS tests administered to BC patients using a customized sequencing platform—FiRST Cancer Panel (FCP)—over 7 years. We systematically described clinical translation of FCP for precise diagnostics, personalized therapeutic strategies, and unraveling disease pathogenesis.
Results:
NGS tests were conducted on 548 samples from 522 patients with BC. Ninety-seven point six percentage of tested samples harbored at least one pathogenic alteration. The common alterations included mutations in TP53 (56.2%), PIK3CA (31.2%), GATA3 (13.8%), BRCA2 (10.2%), and amplifications of CCND1 (10.8%), FGF19 (10.0%), and ERBB2 (9.5%). NGS analysis of ERBB2 amplification correlated well with human epidermal growth factor receptor 2 immunohistochemistry and in situ hybridization. RNA panel analyses found potentially actionable and prognostic fusion genes. FCP effectively screened for potentially germline pathogenic/likely pathogenic mutation. Ten point three percent of BC patients received matched therapy guided by NGS, resulting in a significant overall survival advantage (p=0.022), especially for metastatic BCs.
Conclusion
Clinical NGS provided multifaceted benefits, deepening our understanding of the disease, improving diagnostic precision, and paving the way for targeted therapies. The concrete advantages of FCP highlight the importance of multi-gene testing for BC, especially for metastatic conditions.
7.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
8.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.
9.Establishment of Local Diagnostic Reference Levels for Pediatric Neck CT at Nine University Hospitals in South Korea
Jisun HWANG ; Hee Mang YOON ; Jae-Yeon HWANG ; Young Hun CHOI ; Yun Young LEE ; So Mi LEE ; Young Jin RYU ; Sun Kyoung YOU ; Ji Eun PARK ; Seok Kee LEE
Korean Journal of Radiology 2025;26(1):65-74
Objective:
To establish local diagnostic reference levels (DRLs) for pediatric neck CT based on age, weight, and water-equivalent diameter (WED) across multiple university hospitals in South Korea.
Materials and Methods:
This retrospective study analyzed pediatric neck CT examinations from nine university hospitals, involving patients aged 0–18 years. Data were categorized by age, weight, and WED, and radiation dose metrics, including volume CT dose index (CTDIvol) and dose length product, were recorded. Data retrieval and analysis were conducted using a commercially available dose-management system (Radimetrics, Bayer Healthcare). Local DRLs were established following the International Commission on Radiological Protection guidelines, using the 75th percentile as the reference value.
Results:
A total of 1159 CT examinations were analyzed, including 169 scans from Institution 1, 132 from Institution 2, 126 from Institution 3, 129 from Institution 4, 128 from Institution 5, 105 from Institution 6, 162 from Institution 7, 127 from Institution 8, and 81 from Institution 9. Radiation dose metrics increased with age, weight, and WED, showing significant variability both within and across institutions. For patients weighing less than 10 kg, the DRL for CTDIvol was 5.2 mGy. In the 10–19 kg group, the DRL was 5.8 mGy; in the 20–39 kg group, 7.6 mGy; in the 40–59 kg group, 11.0 mGy; and for patients weighing 60 kg or more, 16.2 mGy. DRLs for CTDIvol by age groups were as follows: 5.3 mGy for infants under 1 year, 5.7 mGy for children aged 1–4 years, 7.6 mGy for ages 5–9 years, 11.2 mGy for ages 10–14 years, and 15.6 mGy for patients 15 years or older.
Conclusion
Local DRLs for pediatric neck CT were established based on age, weight, and WED across nine university hospitals in South Korea.
10.Diagnostic Ability and Correlation of Digital 11C-Methionine PET/CT in Primary Hyperparathyroidism with Inconclusive Standard Imaging
Hee Beom JEONG ; Yong-il KIM ; Soyoon YOON ; Dong Yun LEE ; Beom-Jun KIM ; Seung Hun LEE ; Jin-Sook RYU
Nuclear Medicine and Molecular Imaging 2025;59(1):72-78
Purpose:
11C-Methionine PET/CT is a promising method for detecting parathyroid lesions in patients with primary hyperparathyroidism (PHPT). We aimed to determine the diagnostic ability and correlation of digital 11C-Methionine PET/CT for parathyroid lesions in patients with PHPT, particularly in cases where standard imaging methods yielded inconclusive results.
Methods:
This retrospective analysis was conducted on patients diagnosed with PHPT who underwent digital 11C-Methionine PET/CT imaging because of ambiguous results on standard imaging work-up ( 99m Tc-MIBI parathyroid scan and/or neck ultrasonography). Quantitative 11C-Methionine PET/CT parameters, including maximum standardized uptake value (SUVmax), mean SUV (SUVmean), peak SUV (SUVpeak), parathyroid methionine volume (PMV), and whole methionine uptake(WMU: PMV multiplied by SUVmean) were calculated with various thresholds, and their correlations with biochemical andpathologic parameters were investigated.
Results:
This study included 22 consecutive patients (10 men and 12 women) with a median age of 64.0 years. The lesion detection rate and sensitivity of digital 11C-Methionine PET/CT were 81.8% (18/22) and 100.0% (18/18), respectively.Quantitative analysis revealed that serum PTH (r = 0.490, P = 0.039) and serum calcium (r = 0.583, P = 0.011) were signifi-cantly correlated with PMV50%.
Conclusion
Digital 11C-Methionine PET/CT offers good performance in the detection of parathyroid lesions in PHPT patients with inconclusive standard imaging work-up. The volume parameter of PMV50% significantly correlated biochemi-cal parameters and can serve as a complementary diagnostic tool.

Result Analysis
Print
Save
E-mail