1.Acute Heart Failure Across the Ejection Fraction Spectrum: Phenotypes, Management, and Outcomes From Nationwide KorHF III Registry
Huijin LEE ; Eung Ju KIM ; Seong Woo HAN ; Seong-Mi PARK ; Hyung-Seop KIM ; Myung-Chan CHO ; Hyo-Suk AHN ; Mi-Seung SHIN ; Seok-Jae HWANG ; Jin-Ok JEONG ; Dong Heon YANG ; Junho HYUN ; Jin Oh CHOI ; Hae-Young LEE ; Byung-Su YOO ; Seok-Min KANG ; Dong-Ju CHOI ; Hyun-Jai CHO ;
International Journal of Heart Failure 2026;8(1):43-55
Background and Objectives:
Clinical characteristics and outcomes in acute heart failure (AHF) vary by phenotype. We assessed phenotype-specific features, treatment patterns, and outcomes in a nationwide Korean cohort.
Methods:
The Korean Heart Failure III registry prospectively enrolled 7,351 AHF admissions at 47 hospitals. Among 6,777 patients with available left ventricular ejection fraction (EF), phenotypes were defined as heart failure with reduced EF (HFrEF, ≤40%), mildly reduced EF (HFmrEF,41–49%), or preserved EF (HFpEF, ≥50%). The primary endpoint was a 12-month composite of all-cause death or heart transplantation, evaluated from index admission and, among hospital survivors, from discharge. We used inverse probability weighting (multinomial generalized boosted models with stabilized, trimmed weights) and weighted Cox proportional-hazards models to estimate hazard ratios (HRs).
Results:
Phenotype distribution was 58.9% HFrEF, 13.6% HFmrEF, and 27.5% HFpEF. Crude 12-month composite rates from index admission were 13.4% (HFrEF), 12.7% (HFmrEF), and 16.8% (HFpEF). After weighting, from index admission, HFmrEF (HR, 0.892; 95% confidence interval [CI], 0.731–1.088) and HFpEF (HR, 1.101; 95% CI, 0.939–1.291) did not differ from HFrEF; from discharge, HFpEF had modestly higher risk (HR, 1.207; 95% CI, 1.008–1.445) whereas HFmrEF did not (HR, 1.039; 95% CI, 0.844–1.279). Hyponatremia and chronic kidney disease were consistent adverse markers, while angiotensin-converting enzyme inhibitor/ angiotensin II receptor blocker use at discharge was protective.
Conclusions
Across the EF spectrum, phenotypes showed distinct profiles and risk. Postdischarge risk was modestly higher in HFpEF, supporting phenotype-tailored care and systematic discharge optimization in Korean patients with AHF.
2.Biomimetic Architectural Cover Accelerates `Osseointegration of Titanium Implants
Su-Jin KIM ; Eun Chae KIM ; Weon-Young CHOI ; Seung-Jae LEE ; Je-Hwang RYU
Journal of Bone Metabolism 2026;33(1):30-39
Background:
Although various surface modifications enhance titanium (Ti) implant osseointegration, achieving rapid bone formation comparable to native healing remains challenging. Current strategies primarily focus on micro-scale topography, often overlooking the critical role of macroscopic three-dimensional (3D) architecture in osteoconduction.
Methods:
We hypothesized that mimicking native bone’s porous architecture is key to accelerating osseointegration. First, we verified the impact of structural continuity by comparing standard Ti implants with decellularized bone grafts in a mouse calvaria defect model. Subsequently, we developed a biomimetic polycaprolactone (PCL)-based 3D architectural cover (Cover-type) and evaluated its osseointegration efficacy in a rat femur model against conventional Ti implants.
Results:
The mouse study confirmed that decellularized bone integrated significantly faster than Ti, highlighting the necessity of 3D continuity. In the rat model, micro-computed tomography analysis indicated a clear trend of increased bone formation in the Cover-type group, though statistical significance was limited by sample size. However, histological analysis confirmed a statistically significant enhancement in bone-to-implant contact compared to controls (P<0.05). The PCL structure served as a scaffold for cell migration, effectively bridging the implant-bone gap.
Conclusions
These findings suggest that providing a bone-like 3D environment via a PCL cover may enhance histological osseointegration, rather than relying solely on surface chemistry.
3.Development of a machine learning–based sepsis prediction model for real-world clinical settings in South Korea: a single-center retrospective study
Hye Eun HWANG ; Jungmin YOU ; Min Su KIM ; Da Young KIM ; Jun-Kyu CHOI ; Hyangkyu LEE
Journal of Korean Biological Nursing Science 2026;28(1):191-205
This study aimed to develop a predictive model for the early identification of patients at risk of sepsis, using routinely available clinical information and laboratory test results collected during the initial phase of patient care. Methods: This retrospective analysis included electronic medical records of 22,400 adult patients who presented with suspected infection to a tertiary care university hospital in Korea between January 2013 and May 2024. Patients were classified according to Systemic Inflammatory Response Syndrome (score ≥ 2) or Quick Sequential Organ Failure Assessment (score ≥ 2), in combination with sepsis-related International Classification of Diseases, 10th revision codes. Four different machine learning models were trained and validated using five-fold cross-validation. In addition, Shapley additive explanations analysis was performed to interpret the contribution and clinical relevance of key predictive variables. Results: Among the evaluated models, CatBoost demonstrated the strongest predictive performance. Notably, platelet distribution width, alveolar–arterial oxygen difference, procalcitonin, and the arterial/alveolar oxygen ratio consistently emerged as major predictors. Importantly, several variables that did not reach statistical significance in univariate analysis nevertheless contributed substantially to overall model performance, highlighting the importance of complex, multidimensional interactions among clinical factors. Conclusion: These findings indicate that a model based on simple, routinely collected clinical data can achieve high predictive accuracy and strong generalizability. Such a tool may support early clinical decision-making by multidisciplinary teams, including nurses, across diverse real-world care settings. Further prospective studies are warranted to validate its clinical utility and to assess its potential effects on patient outcomes.
4.Feasibility and Preliminary Efficacy of Digital Cognitive Training in Parkinson’s Disease With Mild Cognitive Impairment: A Pilot Study
Dongje LEE ; Hang-Rai KIM ; Yu Jeong PARK ; Yisuh AHN ; Daeho LEE ; Jungyeun LEE ; Su Jin CHUNG ; Seung Yeon KIM ; Yeji HWANG ; Ji Young YUN ; Jin Whan CHO ; Kyum-Yil KWON ; Seong-Beom KOH ; Sung Hoon KANG
Journal of Movement Disorders 2026;19(1):76-80
Objective:
Cognitive impairment is common in patients with Parkinson’s disease (PD), and few pharmacological options are available for treating this condition. We evaluated the effects of a digital cognitive training program (SUPERBRAIN), which was previously shown to be effective in populations at risk of Alzheimer’s disease, on cognitive function in individuals with PD.
Methods:
Twenty-three individuals with PD and mild cognitive impairment (PD-MCI) from four clinics were randomized to the intervention (n=16) or control (n=7) groups. The intervention group completed a 12-week, home-based, tablet-based cognitive training program (25–30 min/day, 7 days/week). Cognitive outcomes were assessed using the Seoul Neuropsychological Screening Battery pre- and post-intervention.
Results:
The adherence rate was 79.36%. The intervention group showed significant improvements in the Seoul Verbal Learning Test (SVLT) delayed recall and the Controlled Oral Word Association Test, while no changes were observed in the control group. Analysis of covariance confirmed greater SVLT improvement in the intervention group (F statistic=7.15, p=0.015, partial η2=0.28).
Conclusion
SUPERBRAIN is feasible and can improve cognitive function in individuals with PD-MCI.
5.Comparison of tissue-based and plasma-based testing for EGFR mutation in non–small cell lung cancer patients
Yoon Kyung KANG ; Dong Hoon SHIN ; Joon Young PARK ; Chung Su HWANG ; Hyun Jung LEE ; Jung Hee LEE ; Jee Yeon KIM ; JooYoung NA
Journal of Pathology and Translational Medicine 2025;59(1):60-67
Background:
Epidermal growth factor receptor (EGFR) gene mutation testing is crucial for the administration of tyrosine kinase inhibitors to treat non–small cell lung cancer. In addition to traditional tissue-based tests, liquid biopsies using plasma are increasingly utilized, particularly for detecting T790M mutations. This study compared tissue- and plasma-based EGFR testing methods.
Methods:
A total of 248 patients were tested for EGFR mutations using tissue and plasma samples from 2018 to 2023 at Pusan National University Yangsan Hospital. Tissue tests were performed using PANAmutyper, and plasma tests were performed using the Cobas EGFR Mutation Test v2.
Results:
All 248 patients underwent tissue-based EGFR testing, and 245 (98.8%) showed positive results. Of the 408 plasma tests, 237 (58.1%) were positive. For the T790M mutation, tissue biopsies were performed 87 times in 69 patients, and 30 positive cases (38.6%) were detected. Plasma testing for the T790M mutation was conducted 333 times in 207 patients, yielding 62 positive results (18.6%). Of these, 57 (27.5%) were confirmed to have the mutation via plasma testing. Combined tissue and plasma tests for the T790M mutation were positive in nine patients (13.4%), while 17 (25.4%) were positive in tissue only and 12 (17.9%) in plasma only. This mutation was not detected in 28 patients (43.3%).
Conclusions
Although the tissue- and plasma-based tests showed a sensitivity of 37.3% and 32.8%, respectively, combined testing increased the detection rate to 56.7%. Thus, neither test demonstrated superiority, rather, they were complementary.
6.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
7.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
8.Constitutional Chromosome 21 Abnormality in B-ALL with iAMP21 in a Patient Developing Treatment-Related Myelodysplastic Syndrome
Inhwa KIM ; Su Hyun YOON ; Sunghan KANG ; Kyung-Nam KOH ; Mi Young KIM ; Young-Uk CHO ; Sang-Hyun HWANG ; Seongsoo JANG ; Eul-Ju SEO ; Beom Hee LEE ; Sunghee MIN ; Hyunwoo BAE ; Ho Joon IM ; Hyery KIM
Clinical Pediatric Hematology-Oncology 2025;32(1):23-28
The initial molecular cytogenetic characteristics of blasts plays a significant role in determining the treatment course of B-cell acute lymphoblastic leukemia (B-ALL).B-ALL with intrachromosomal amplification of chromosome 21 (iAMP21) has been well known to have unfavorable prognosis. Also, there are previously recognized germline mutations that increase the risk of ALL, such as trisomy 21, Down syndrome. This case report is about a 16-year-old girl who presented with lymphadenitis, purpura, and fever followed by initial lab of elevated white blood cell with blasts.She had some notable facial features, but no typical Down syndrome related one.Bone marrow biopsy and fluorescence in situ hybridization finalized the diagnosis as B-ALL with iAMP21, high-risk group. The minimal residual disease-negative complete remission was achieved after the induction chemotherapy with Korean multicenter high-risk protocol. However, abnormal karyotype was sustained in bone marrow. Microarrays with her buccal swab raised the possibility that the abnormal karyotype was not from the leukemic blasts but rather from the germline. Although she underwent scheduled chemotherapy uneventfully as slow early responder type, thrombocytopenia and abnormal karyotype persisted, leading to the diagnosis of acute myeloid leukemia. Additional chemotherapy and peripheral blood stem cell transplantation was performed which resulted in engraftment. This case highlights the discovery of a constitutional genetic aberration, which played like a silent yet critical background factor for B-ALL with iAMP21. As the number of reported cases are limited, the role of germline chromosome 21 mutation as the indicator for prognosis of B-ALL should be studied further.
9.Validation of the Korean Version of the Huntington’s Disease Quality of Life Battery for Carers
Hee Jin CHANG ; Eungseok OH ; Won Tae YOON ; Chan Young LEE ; Kyum-Yil KWON ; Yun Su HWANG ; Chaewon SHIN ; Jee-Young LEE
Journal of Movement Disorders 2025;18(2):160-164
Objective:
The Huntington’s Disease Quality of Life Battery for Carers (HDQoL-C) is used to evaluate caregiver quality of life. This study aimed to develop and validate the Korean version of the HDQoL-C (K-HDQoL-C) to assess the burden on Korean caregivers of Huntington’s disease (HD) patients.
Methods:
A total of 19 HD caregivers (7 females, mean age 55.4±14.6 years) participated in this study. The K-HDQoL-C, a translation of the English version, consisted of demographic information, caring aspects, life satisfaction, and feelings about life. It was administered twice, 2 weeks apart. Internal consistency was evaluated using Cronbach’s α, and test-retest reliability was assessed with intraclass correlation coefficients. The relationship with the Zarit Burden Interview-12 (ZBI-12) was analyzed.
Results:
The internal consistencies of the K-HDQoL-C were 0.771 (part 2), 0.938 (part 3), and 0.891 (part 4). The test-retest reliability ranged from 0.908 to 0.936. Part 3 was negatively correlated with the ZBI-12, and part 4 was positively correlated with the ZBI-12 (r=-0.780, 0.923; p<0.001).
Conclusion
The K-HDQoL-C effectively evaluates the challenges faced by HD caregivers, particularly in terms of care aspects and life satisfaction.
10.Comparison of tissue-based and plasma-based testing for EGFR mutation in non–small cell lung cancer patients
Yoon Kyung KANG ; Dong Hoon SHIN ; Joon Young PARK ; Chung Su HWANG ; Hyun Jung LEE ; Jung Hee LEE ; Jee Yeon KIM ; JooYoung NA
Journal of Pathology and Translational Medicine 2025;59(1):60-67
Background:
Epidermal growth factor receptor (EGFR) gene mutation testing is crucial for the administration of tyrosine kinase inhibitors to treat non–small cell lung cancer. In addition to traditional tissue-based tests, liquid biopsies using plasma are increasingly utilized, particularly for detecting T790M mutations. This study compared tissue- and plasma-based EGFR testing methods.
Methods:
A total of 248 patients were tested for EGFR mutations using tissue and plasma samples from 2018 to 2023 at Pusan National University Yangsan Hospital. Tissue tests were performed using PANAmutyper, and plasma tests were performed using the Cobas EGFR Mutation Test v2.
Results:
All 248 patients underwent tissue-based EGFR testing, and 245 (98.8%) showed positive results. Of the 408 plasma tests, 237 (58.1%) were positive. For the T790M mutation, tissue biopsies were performed 87 times in 69 patients, and 30 positive cases (38.6%) were detected. Plasma testing for the T790M mutation was conducted 333 times in 207 patients, yielding 62 positive results (18.6%). Of these, 57 (27.5%) were confirmed to have the mutation via plasma testing. Combined tissue and plasma tests for the T790M mutation were positive in nine patients (13.4%), while 17 (25.4%) were positive in tissue only and 12 (17.9%) in plasma only. This mutation was not detected in 28 patients (43.3%).
Conclusions
Although the tissue- and plasma-based tests showed a sensitivity of 37.3% and 32.8%, respectively, combined testing increased the detection rate to 56.7%. Thus, neither test demonstrated superiority, rather, they were complementary.

Result Analysis
Print
Save
E-mail