1.Part 1. Current Status of Hearing Loss Patients in Korea Using National Data: National Health Insurance Service- Database, 2010 to 2020
Junhun LEE ; Chul Young YOON ; Jiwon KIM ; In-Ki JIN ; Michelle J. SUH ; Wan-Ho CHO ; Hyo-Jeong LEE ; Seong Jun CHOI ; Dongchul CHA ; Kyung Ho PARK ; Soo Hee OH ; Young Joon SEO ; Tae Hoon KONG
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(1):7-18
Background and Objectives:
Hearing loss significantly affects communication, psychosocial well-being, and quality of life. This study analyzes the National Health Insurance Service database to assess the trends and characteristics of hearing loss in South Korea from 2010 to 2020.Subjects and Method The database encompasses 97% of the Korean population, providing comprehensive data on medical history, prescriptions, and health examinations. The analysis used the World Health Organization’s ICD-10 definitions to categorize hearing loss types and examine their prevalence and incidence across various demographics over 11 years.
Results:
There was an overall annual increase of 4.62% in diagnosed cases of hearing loss, with the most significant rise among the elderly. The rate of increase accelerated from 3.32% between 2010 and 2014 to 6.49% between 2014 and 2020, corresponding with the improved hearing aid access facilitated by policy changes. Women showed a slightly higher increase than men. The data also indicated a consistent rise in abnormal hearing test results during health examinations, especially in older adults.
Conclusion
The study highlights an increasing trend in hearing loss diagnoses, driven by an aging population and enhanced detection facilitated by policy changes. These findings emphasize the need for continuous monitoring and targeted health policies to manage hearing loss effectively, offering valuable insights for global health management and policy development.
2.Part 2. Current Status of Hearing Disability and Hearing Rehabilitation Devices in Korea Using National Data: NHIS-Database, 2010 to 2020
Junhun LEE ; Chul Young YOON ; Jiwon KIM ; In-Ki JIN ; Michelle J. SUH ; Wan-Ho CHO ; Hyo-Jeong LEE ; Seong Jun CHOI ; Dongchul CHA ; Kyung Ho PARK ; Soo Hee OH ; Young Joon SEO ; Tae Hoon KONG
Korean Journal of Otolaryngology - Head and Neck Surgery 2025;68(3):94-104
Background and Objectives:
This study aims to analyze trends in hearing disability and the use of hearing rehabilitation devices (hearing aids and cochlear implants) in South Korea over the past 11 years (2010-2020) using data from the National Health Insurance Service (NHIS).Subjects and Method Data were extracted from the NHIS database, covering approximately 97% of the South Korean population. Patients diagnosed with hearing loss were classified using ICD-10 codes. The data were analyzed to determine trends in hearing disability, hearing aid prescriptions, and cochlear implant usage by age, gender, and types and causes of hearing loss.
Results:
The number of hearing disability patients increased from 170900 in 2010 to 362738 in 2020, with an annual growth rate of 7.95%. The highest increase was observed in the ≥60 age group, with an annual growth rate of 11.04%. Hearing aid prescriptions rose from 4966 in 2010 to 11974 in 2020, showing a 10.45% annual increase. Females showed a higher growth rate in both hearing disability and hearing aid prescriptions compared to males. Cochlear implant prescriptions also increased, particularly among older adults.
Conclusion
The study highlights a significant rise in hearing disability and the use of hearing aids and cochlear implants in South Korea, especially among the elderly. The findings underscore the importance of early diagnosis and intervention for hearing loss and the need for policy improvements to enhance accessibility and affordability of hearing rehabilitation services. Additional strategies are needed to ensure appropriate hearing rehabilitation for those not yet receiving adequate care.
4.Two Cases of Pancreatobiliary Disease Complications Treated Using Over-the-Scope Clip
Byung Soo KWAN ; Bo Ram SUNG ; Kwang Min KIM
Korean Journal of Pancreas and Biliary Tract 2025;30(1):26-30
The over-the-scope clip (OTSC) system is a powerful full-thickness suturing device used for closing refractory bleeding, perforations, and fistulas in gastrointestinal diseases, offering greater force than conventional clips. Here, we report two cases of pancreatobiliary disease treated using OTSC. The first case involved the successful OTSC ligation of a colonic fistula caused by necrotizing pancreatitis, and the second was a duodenal perforation due to stent migration, which was also successfully treated with OTSC. These cases indicate that OTSC can be beneficial for pancreatobiliary diseases, potentially eliminating the need for surgery when endoscopic treatment is successful.
5.Eosinophilic Cholangitis Diagnosed in a Patient with Abnormal Liver Enzymes: A Case Report
Sung Hoon CHANG ; Jun Yeol KIM ; Yong Soo SONG ; Tae Seung LEE ; Jin Ho CHOI ; Woo Hyun PAIK ; Sang Hyub LEE ; Ji Kon RYU ; In Rae CHO
Korean Journal of Pancreas and Biliary Tract 2025;30(1):19-25
It is difficult to determine a cause of bile duct stricture and dilatation. Eosinophilic cholangitis, a rare benign condition, may be one cause of bile duct stricture and dilatation. It can be evaluated using various methods of histopathology, radiographs, endoscopy, and hematologic findings. Treatment generally involves steroid therapy which can lead to improvement. This case report will discuss eosinophilic cholangitis, emphasizing that while it can easily be overlooked but should be considered in differential diagnoses.
6.Deep Learning-Accelerated Non-Contrast Abbreviated Liver MRI for Detecting Malignant Focal Hepatic Lesions: Dual-Center Validation
So Hyun PARK ; Moon Hyung CHOI ; Bohyun KIM ; Hyun-Soo LEE ; Sungjin YOON ; Young Joon LEE ; Dominik NICKEL ; Thomas BENKERT
Korean Journal of Radiology 2025;26(4):333-345
Objective:
To compare a deep learning (DL)-accelerated non-enhanced abbreviated MRI (AMRI DL) protocol with standard AMRI (AMRI STD) of the liver in terms of image quality and malignant focal lesion detection.
Materials and Methods:
This retrospective study included 155 consecutive patients (110 male; mean age 62.4 ± 11 years) from two sites who underwent standard liver MRI and additional AMRIDL sequences, specifically DL-accelerated single-shot fast-spin echo (SSFSE DL) and DL-accelerated diffusion-weighted imaging (DWIDL). Additional MRI phantom experiments assessed signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) values. Three reviewers evaluated AMRIDL and AMRI STD protocols for image quality using a five-point Likert scale and identified malignant hepatic lesions. Image quality scores and per-lesion sensitivities were compared between AMRIDL and AMRI STD using the Wilcoxon signed-rank test and logistic regression with generalized estimating equations, respectively.
Results:
Phantom experiments demonstrated comparable SNR and higher CNR for SSFSE DL compared to SSFSE STD, with similar ADC values for DWIDL and DWI STD. Among the 155 patients, 130 (83.9%) had chronic liver disease or a history of intra- or extrahepatic malignancy. Of 104 malignant focal lesions in 64 patients, 58 (55.8%) were hepatocellular carcinomas (HCCs), 38 (36.5%) were metastases, four (3.8%) were cholangiocarcinomas, and four (3.8%) were lymphomas. The pooled per-lesion sensitivity across three readers was 97.6% for AMRIDL, comparable to 97.6% for AMRI STD. Compared with AMRI STD, AMRIDL demonstrated superior image quality regarding structural sharpness, artifacts, and noise (all P < 0.001) and reduced the average scan time by approximately 50% (2 min 29 sec vs. 4 min 11 sec). In patients with chronic liver disease, AMRIDL achieved a 96.6% per-lesion sensitivity for HCC detection, similar to 96.5% for AMRI STD (P > 0.05).
Conclusion
The AMRIDL protocol offers comparable sensitivity for detecting malignant focal lesions, including HCC while significantly enhancing image quality and reducing scan time by approximately 50% compared to AMRI STD.
7.Radiofrequency Ablation for Recurrent Thyroid Cancers:2025 Korean Society of Thyroid Radiology Guideline
Eun Ju HA ; Min Kyoung LEE ; Jung Hwan BAEK ; Hyun Kyung LIM ; Hye Shin AHN ; Seon Mi BAEK ; Yoon Jung CHOI ; Sae Rom CHUNG ; Ji-hoon KIM ; Jae Ho SHIN ; Ji Ye LEE ; Min Ji HONG ; Hyun Jin KIM ; Leehi JOO ; Soo Yeon HAHN ; So Lyung JUNG ; Chang Yoon LEE ; Jeong Hyun LEE ; Young Hen LEE ; Jeong Seon PARK ; Jung Hee SHIN ; Jin Yong SUNG ; Miyoung CHOI ; Dong Gyu NA ;
Korean Journal of Radiology 2025;26(1):10-28
Radiofrequency ablation (RFA) is a minimally invasive treatment modality used as an alternative to surgery in patients with benign thyroid nodules, recurrent thyroid cancers (RTCs), and primary thyroid microcarcinomas. The Korean Society of Thyroid Radiology (KSThR) initially developed recommendations for the optimal use of RFA for thyroid tumors in 2009 and revised them in 2012 and 2017. As new meaningful evidence has accumulated since 2017 and in response to a growing global interest in the use of RFA for treating malignant thyroid lesions, the task force committee members of the KSThR decided to update the guidelines on the use of RFA for the management of RTCs based on a comprehensive analysis of current literature and expert consensus.
8.Safety and Efficacy of Venous Coil-Embolization of Type IIa Pelvic Arteriovenous Malformations
Lyo Min KWON ; Sang Yub LEE ; Young Soo DO ; Kwang Bo PARK ; Jun Gon KIM ; Shin-Seok YANG ; Dong-Ik KIM
Korean Journal of Radiology 2025;26(3):239-245
Objective:
To evaluate the safety and efficacy of coil embolization of venous segments in patients with Type IIa pelvic arteriovenous malformations (AVMs).
Materials and Methods:
A retrospective study was performed on 13 patients (median age, 43 years, range 20–62 years, 7 males) who underwent transvenous coil embolization for Type IIa pelvic AVM (characterized by multiple arterioles shunting to focal venous segments of a single draining vein) without the use of additional liquid embolic agents from March 2017 to February 2023. Treatment outcomes were analyzed based on clinical evaluations, post angiography findings, and follow-up CT.
Results:
Fourteen procedures were performed on 13 patients. Except in one patient, all treatments were completed in a single session. Transvenous access was employed in 10 procedures, whereas direct puncture was used in four sessions. The embolization procedures used an average of 55.7 ± 58.5 coils (range, 7–238) and lasted an average of 127.3 ± 39.5 minutes.The technical success rate was 92.9% (of 13/14). All patients reported symptom improvement. Follow-up CT scans showed complete occlusion of the AVM without recurrence in ten of the 13 patients. There was one minor adverse event: a small retroperitoneal hemorrhage, likely related to direct puncture, which resolved spontaneously. No other adverse events were observed.
Conclusion
Coil embolization of the draining vein segment, without the use of additional liquid embolic agents is a safe and effective method for managing Type IIa pelvic AVM.
9.Performance of Digital Mammography-Based Artificial Intelligence Computer-Aided Diagnosis on Synthetic Mammography From Digital Breast Tomosynthesis
Kyung Eun LEE ; Sung Eun SONG ; Kyu Ran CHO ; Min Sun BAE ; Bo Kyoung SEO ; Soo-Yeon KIM ; Ok Hee WOO
Korean Journal of Radiology 2025;26(3):217-229
Objective:
To test the performance of an artificial intelligence-based computer-aided diagnosis (AI-CAD) designed for fullfield digital mammography (FFDM) when applied to synthetic mammography (SM).
Materials and Methods:
We analyzed 501 women (mean age, 57 ± 11 years) who underwent preoperative mammography and breast cancer surgery. This cohort consisted of 1002 breasts, comprising 517 with cancer and 485 without. All patients underwent digital breast tomosynthesis (DBT) and FFDM during the preoperative workup. The SM is routinely reconstructed using DBT. Commercial AI-CAD (Lunit Insight MMG, version 1.1.7.2) was retrospectively applied to SM and FFDM to calculate the abnormality scores for each breast. The median abnormality scores were compared for the 517 breasts with cancer using the Wilcoxon signed-rank test. Calibration curves of abnormality scores were evaluated. The discrimination performance was analyzed using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity using a 10% preset threshold. Sensitivity and specificity were further analyzed according to the mammographic and pathological characteristics.The results of SM and FFDM were compared.
Results:
AI-CAD demonstrated a significantly lower median abnormality score (71% vs. 96%, P < 0.001) and poorer calibration performance for SM than for FFDM. SM exhibited lower sensitivity (76.2% vs. 82.8%, P < 0.001), higher specificity (95.5% vs.91.8%, P < 0.001), and comparable AUC (0.86 vs. 0.87, P = 0.127) than FFDM. SM showed lower sensitivity than FFDM in asymptomatic breasts, dense breasts, ductal carcinoma in situ, T1, N0, and hormone receptor-positive/human epidermal growth factor receptor 2-negative cancers but showed higher specificity in non-cancerous dense breasts.
Conclusion
AI-CAD showed lower abnormality scores and reduced calibration performance for SM than for FFDM.Furthermore, the 10% preset threshold resulted in different discrimination performances for the SM. Given these limitations, off-label application of the current AI-CAD to SM should be avoided.
10.Effects of Deep Learning-Based Reconstruction on the Quality of Accelerated Contrast-Enhanced Neck MRI
Minkook SEO ; Kook-Jin AHN ; Hyun-Soo LEE ; Marcel Dominik NICKEL ; Jinhee JANG ; Yeon Jong HUH ; Ilah SHIN ; Ji Young LEE ; Bum-soo KIM
Korean Journal of Radiology 2025;26(5):446-459
Objective:
To compare the quality of deep learning-reconstructed turbo spin-echo (DL-TSE) and conventionally interpolated turbo spin-echo (Conv-TSE) techniques in contrast-enhanced MRI of the neck.
Materials and Methods:
Contrast-enhanced T1-weighted DL-TSE and Conv-TSE images were acquired using 3T scanners from 106 patients. DL-TSE employed a closed-source, ‘work-in-progress’ (WIP No. 1062, iTSE, version 10; Siemens Healthineers) algorithm for interpolation and denoising to achieve the same in-plane resolution (axial: 0.26 x 0.26 mm 2 ; coronal: 0.29 x 0.29 mm 2 ) while reducing scan times by 15.9% and 52.6% for axial and coronal scans, respectively. The full width at half maximum (FWHM) and percent signal ghosting were measured using stationary and flow phantom scans, respectively. In patient images, non-uniformity (NU), contrast-to-noise ratio (CNR), and regional mucosal FWHM were evaluated. Two neuroradiologists visually rated the patient images for overall quality, sharpness, regional mucosal conspicuity, artifacts, and lesions using a 5-point Likert scale.
Results:
FWHM in the stationary phantom scan was consistently sharper in DL-TSE. The percent signal ghosting outside the flow phantom was lower in DL-TSE (0.06% vs. 0.14%) but higher within the phantom (8.92% vs. 1.75%) compared to ConvTSE. In patient scans, DL-TSE showed non-inferior NU and higher CNR. Regional mucosal FWHM was significantly better in DL-TSE, particularly in the oropharynx (coronal: 1.08 ± 0.31 vs. 1.52 ± 0.46 mm) and hypopharynx (coronal: 1.26 ± 0.35 vs. 1.91 ± 0.56 mm) (both P < 0.001). DL-TSE demonstrated higher overall image quality (axial: 4.61 ± 0.49 vs. 3.32 ± 0.54) and sharpness (axial: 4.40 ± 0.56 vs. 3.11 ± 0.53) (both P < 0.001). In addition, mucosal conspicuity was improved, especially in the oropharynx (axial: 4.41 ± 0.67 vs. 3.40 ± 0.69) and hypopharynx (axial: 4.45 ± 0.58 vs. 3.58 ± 0.63) (both P < 0.001).Extracorporeal ghost artifacts were reduced in DL-TSE (axial: 4.32 ± 0.60 vs. 3.90 ± 0.71, P < 0.001) but artifacts overlapping anatomical structures were slightly more pronounced (axial: 3.78 ± 0.74 vs. 3.95 ± 0.72, P < 0.001). Lesions were detected with higher confidence in DL-TSE.
Conclusion
DL-based reconstruction applied to accelerated neck MRI improves overall image quality, sharpness, mucosal conspicuity in motion-prone regions, and lesion detection confidence. Despite more pronounced ghost artifacts overlapping anatomical structures, DL-TSE enables substantial scan time reduction while enhancing diagnostic performance.

Result Analysis
Print
Save
E-mail