1.Mosquito monitoring and influence of meteorological factors on mosquito density around Beijing Capital International Airport, 2016-2022
Ran FENG ; Tie-zheng MA ; Si-jie ZHU ; Bo TIAN ; Fei QUAN ; Zhi-lin WU ; Xiao-tao LIU ; Fu-yuan ZHANG ; Song-jian ZHANG
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):40-48
Objective To understand mosquito density, species composition, and seasonal variations around the Beijing Capital International Airport(BCIA)and provide scientific evidence for mosquito-borne disease prevention and control. Methods Meteorological data were collected from 2016 to 2022, and mosquito density was monitored at seven surveillance sites around the BCIA from May to October each year using CO2-baited mosquito traps to analyze the relationship between mosquito density and meteorological factors. Results In total,68 518 female mosquitoes were captured, with a mosquito density of 10.20 per light · hour. The dominant species was Culex pipiens pallens(73.90%), followed by Aedes albopictus(9.71%)and Ae. vexans(9.29%);the mosquito density was highest in 2016(14.8 per light·hour)and lowest in 2022(4.46 per light·hour). Significant statistical differences were observed in mosquito density among different species(F=18.118, P<0.05). The density of Cx. pipiens pallens and other mosquito species showed a mutually exclusive trend; the peak of mosquito density varied based on years and habitats, with significant statistical differences in mosquito density among different habitats(F=8.504, P<0.05). The highest mosquito density was observed near the Wenyu River(21.50 per light·hour), whereas the lowest was recorded at the BCIA construction site(2.44 per light· hour). The monthly average temperature(r=0.595), monthly average highest temperature(r=0.575), and monthly average lowest temperature(r=0.624)showed moderate positive correlations, whereas the monthly average air pressure(r=-0.484)showed a moderate negative correlation. The monthly average minimum temperature was included in the regression model(F=25.575, P<0.000), and the equation Y=1.029X4-8.181 was used. The monthly average air pressure 2 months prior(b=-2.418, β=-1.619, P<0.05)and the monthly average relative humidity(b=-0.739, β=-1.201, P<0.05)significantly negatively predicted the mosquito density. Notably, the regression equation used was y=2526.170+(-2.418)X9+(-0.739)X13. The exposure-response analysis revealed that the density of mosquitoes was not linearly related to the average monthly air pressure, rainfall, and duration of sunshine. Conclusions The dominant mosquito species around the BCIA was Cx. pipiens pallens, Ae. albopictus, and Ae. vexans. During the control of Cx. pipiens pallens, the impact on other mosquito species must also be considered. Environmental management, breeding sites, and scientific use of pesticides should be prioritized based on the activity periods of mosquitoes. Further studies on mosquitoes and meteorological factors should be conducted to provide references and novel avenues for mosquito control.
2.MADS-Net: a Multi-scale Attention and Dynamic Sparse Mask Fusion Network for Electrical Impedance Tomography Image Reconstruction in Breast Screening
Cheng-Tao YU ; Jia-Hui WANG ; Song-Pei HU ; Huai-Jin CHEN ; Li DING ; Xia YE ; Jia-Feng YAO
Progress in Biochemistry and Biophysics 2026;53(9):2480-2496
ObjectiveTo address the key challenges in breast electrical impedance tomography (EIT) reconstruction including the severe ill‑posedness of the inverse problem, limited measurement information from the electrodes, low contrast of small lesions, as well as the common drawbacks of traditional reconstruction methods such as boundary blurring, low spatial resolution, and weak small-target detection capability, and to overcome the limitations of existing deep learning approaches namely low training efficiency, insufficient physical consistency, and substantial information loss during the low‑to‑high dimensional mapping process, this study proposes a multi‑scale attention and dynamic sparse mask fusion network (MADS‑Net). The proposed method aims to enhance high‑resolution reconstruction accuracy, small-lesion detectability, noise robustness, and computational efficiency in breast‑screening-oriented EIT, thereby providing a feasible solution for the application of EIT in breast functional imaging. MethodsThe proposed network adopts a strategy of “locate first, reconstruct later”. It realizes adaptive allocation of computational resources through a dynamic mask module, alleviates information loss in the low-to-high dimensional mapping process via a multi-scale attention mechanism, and embeds physical constraints to improve the physical rationality of reconstruction results. The performance of the proposed method was validated through systematic numerical simulations, agar phantom experiments, and porcine tissue experiments. Comparisons were made with mainstream methods including the Gauss-Newton algorithm, convolutional neural networks, U-Net, and Deep D-Bar. The image correlation coefficient (ICC), root mean square error (RMSE), and peak signal-to-noise ratio (PSNR) were adopted as quantitative evaluation metrics. Furthermore, lesion‑level evaluation metrics were introduced to assess the capability of different methods in reconstructing abnormal target boundaries and small‑sized target regions. ResultsExperimental results demonstrate that MADS-Net outperforms all comparison methods across all test scenarios. In numerical simulations, it achieves higher accuracy in target morphology and spatial location recovery as well as better background suppression. In agar phantom experiments, its detection and imaging reliability for small targets is significantly superior to the comparison methods. In porcine tissue experiments, the model maintains good generalization performance and can adapt to complex biological tissue imaging scenarios. Quantitative results show that MADS-Net achieves an average ICC of 0.917 6±0.048 8, an RMSE as low as0.060 6±0.031 6, and a PSNR of (23.893 9±2.685 3) dB. It successfully detects tiny targets as small as 5 mm within a 100 mm diameter sensing field, reduces the total training duration by 23.5% compared with the baseline method, and maintains stable reconstruction performance even under strong noise interference. ConclusionThe results demonstrate that MADS-Net achieves favorable EIT reconstruction performance in numerical simulations, agar phantom experiments, and porcine tissue experiments, even under common practical imaging challenges including low signal-to-noise ratio and blurred tissue boundaries. This study provides a methodological reference for further research on EIT in breast-screening-related scenarios and other medical functional imaging tasks, and also offers a low-cost, radiation-free alternative for breast lesion screening that aligns with the clinical demand for non-invasive diagnostic tools. It should be noted that real clinical breast data have not yet been used for validation in this study, and the clinical applicability of the proposed method requires further investigation. Future work will prioritize collecting multi-center real clinical breast datasets, and further optimize the model’s generalization ability to adapt to individual differences in breast tissue composition to promote its clinical application.
3.Equivalence of SYN008 versus omalizumab in patients with refractory chronic spontaneous urticaria: A multicenter, randomized, double-blind, parallel-group, active-controlled phase III study.
Jingyi LI ; Yunsheng LIANG ; Wenli FENG ; Liehua DENG ; Hong FANG ; Chao JI ; Youkun LIN ; Furen ZHANG ; Rushan XIA ; Chunlei ZHANG ; Shuping GUO ; Mao LIN ; Yanling LI ; Shoumin ZHANG ; Xiaojing KANG ; Liuqing CHEN ; Zhiqiang SONG ; Xu YAO ; Chengxin LI ; Xiuping HAN ; Guoxiang GUO ; Qing GUO ; Xinsuo DUAN ; Jie LI ; Juan SU ; Shanshan LI ; Qing SUN ; Juan TAO ; Yangfeng DING ; Danqi DENG ; Fuqiu LI ; Haiyun SUO ; Shunquan WU ; Jingbo QIU ; Hongmei LUO ; Linfeng LI ; Ruoyu LI
Chinese Medical Journal 2025;138(16):2040-2042
4.Effect of measurement site on diagnostic performance of CT-derived fractional flow reserve
Yutao ZHOU ; Na ZHAO ; Yunqiang AN ; Lei SONG ; Chaowei MU ; Jingang CUI ; Tao JIANG ; Li XU ; Hongjie HU ; Lin LI ; Dumin LI ; Wenqiang CHEN ; Lijuan FAN ; Feng ZHANG ; Yang GAO ; Bin LYU
Chinese Journal of Radiology 2025;59(6):704-711
Objective:To investigate the effect of CT-derived fractional flow reserve (CT-FFR) measurement sites on the values and the diagnostic performance, and to determine the optimal measurement site for CT-FFR using invasive FFR as the reference standard.Methods:This study was part of the CT-FFR CHINA clinical trial. Patients with suspected coronary artery disease who were scheduled for invasive coronary angiography (ICA) were prospectively recruited from five clinical centers across the country from November 2018 to March 2020. Each enrolled patient underwent coronary CT angiography (CCTA), CT-FFR, ICA, and invasive pressure wire-based FFR assessments sequentially within one week. Four groups of CT-FFR values were obtained on each enrolled target vessels according to different CT-FFR measurement locations: 1, 2, 3 cm distal to the target lesion, and terminal vessel groups. Spearman and Bland-Altman analyses were used to explore the correlation and consistency of CT-FFR values and FFR values at different measurement sites. The measurement deviation of CT-FFR was also compared. Diagnostic accuracy and performance of CT-FFR, including sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve (AUC), in discriminating myocardial ischemia were analyzed across all measurement site groups on a per-vessel level, using FFR as the reference standard.Results:A total of 289 patients with 345 target lesion vessels were included. According to CCTA, there were 51 target vessels (14.8%) with<50% stenosis, 106 vessels (30.7%) with 50%-69% stenosis, and 188 vessels (54.5%) with stenosis≥70%. At per-vessel level, CT-FFR and FFR values at each measurement position group were highly positively correlated: 1 cm distal to target lesion group, r=0.734 ( P<0.001); 2 cm distal to target lesion group, r=0.732 ( P<0.001); 3 cm distal to target lesion group, r=0.737 ( P<0.001); terminal vessel group was 0.719 ( P<0.001). At per-vessel level, CT-FFR and FFR values of all measurement sites were in good agreement (Bland-Altman analysis results): 1 cm distal to target lesion group, 0.014 (95% LoA 0.002-0.026); 2 cm distal to target lesion group, 0.026 (95% LoA 0.015-0.038); 3 cm distal to target lesion group, 0.040 (95% LoA 0.039-0.051); terminal vessel group, 0.075 (95% LoA 0.064-0.087). And at per-vessel level, the accuracy of diagnosing myocardial ischemia with CT-FFR at 1 cm was highest [84.6% (95% CI 80.4%-88.3%)], and the lowest accuracy in the terminal vessel group [67.0% (95% CI 61.7%-72.0%)]. However, there was no significant difference in the diagnostic accuracy of CT-FFR at 1 cm, 2 cm [80.6% (95% CI 76.1%-84.6%)] and 3 cm [77.5% (95% CI 72.6%-81.7%)]. AUC of CT-FFR at 1 cm distal to the lesion were both highest for global level and moderately stenosis (50%-69%) lesions [0.85 (95% CI 0.81-0.89), 0.84 (95% CI 0.77-0.90)]. And the differences were statistically significant among the four measurement location groups (all P<0.05). Conclusions:The deviation of CT-FFR increases with measurement site distance distal to target lesions. One centimeter distal to the target lesion is the optimal measurement site, and the CT-FFR value here shows the highest diagnostic performance for myocardial ischemic lesions, especially for moderate stenosis.
5.Association between Per and Polyfluoroalkyl Substance and Abdominal Fat Distribution: A Trait Spectrum Exposure Pattern and Structure-Based Investigation.
Zhi LI ; Shi Lin SHAN ; Chen Yang SONG ; Cheng Zhe TAO ; Hong QIAN ; Qin YUAN ; Yan ZHANG ; Qiao Qiao XU ; Yu Feng QIN ; Yun FAN ; Chun Cheng LU
Biomedical and Environmental Sciences 2025;38(1):3-14
OBJECTIVE:
To investigate the associations between eight serum per- and polyfluoroalkyl substances (PFASs) and regional fat depots, we analyzed the data from the National Health and Nutrition Examination Survey (NHANES) 2011-2018 cycles.
METHODS:
Multiple linear regression models were developed to explore the associations between serum PFAS concentrations and six fat compositions along with a fat distribution score created by summing the concentrations of the six fat compositions. The associations between structurally grouped PFASs and fat distribution were assessed, and a prediction model was developed to estimate the ability of PFAS exposure to predict obesity risk.
RESULTS:
Among females aged 39-59 years, trunk fat mass was positively associated with perfluorooctane sulfonate (PFOS). Higher concentrations of PFOS, perfluorohexane sulfonate (PFHxS), perfluorodecanoate (PFDeA), perfluorononanoate (PFNA), and n-perfluorooctanoate (n-PFOA) were linked to greater visceral adipose tissue in this group. In men, exposure to total perfluoroalkane sulfonates (PFSAs) and long-chain PFSAs was associated with reductions in abdominal fat, while higher abdominal fat in women aged 39-59 years was associated with short-chain PFSAs. The prediction model demonstrated high accuracy, with an area under the curve (AUC) of 0.9925 for predicting obesity risk.
CONCLUSION
PFAS exposure is associated with regional fat distribution, with varying effects based on age, sex, and PFAS structure. The findings highlight the potential role of PFAS exposure in influencing fat depots and obesity risk, with significant implications for public health. The prediction model provides a highly accurate tool for assessing obesity risk related to PFAS exposure.
Humans
;
Fluorocarbons/blood*
;
Female
;
Adult
;
Middle Aged
;
Male
;
Environmental Pollutants/blood*
;
Abdominal Fat
;
Nutrition Surveys
;
Alkanesulfonic Acids/blood*
;
Obesity
;
Environmental Exposure
6.Multicenter randomized controlled trial of Yiqi Huoxue formula() for the treatment of ruptured lumbar disc herniation.
Yu ZHU ; Zhi-Qiang WANG ; Shun LIN ; Ying-Ying YAO ; Xue-Qiang SHEN ; Xiao-Chun LI ; Feng YU ; Xiao-Yang XIONG ; Yi SONG ; Meng-Fei CHEN ; Peng-Fei YU ; Hong JIANG ; Jin-Tao LIU
China Journal of Orthopaedics and Traumatology 2025;38(11):1112-1118
OBJECTIVE:
To observe the clinical symptoms and MRI outcomes of patients with ruptured lumbar disc herniation(LDH) through a multicenter randomized controlled study, and to evaluate the clinical efficacy and safety of Yiqi Huoxue formula() in the treatment of this disease.
METHODS:
A total of 160 outpatients and inpatients with ruptured LDH admitted to 4 medical centers from January 2023 to June 2023 were selected and randomly divided into the Yiqi Huoxue formula group and the control group, with 80 patients in each group. In the Yiqi Huoxue formula group, there were 43 males and 37 females, with an age of (41.03±9.56) years and a disease duration of (10.45±25.37) days, and the patients were treated with Yiqi Huoxue formula. In the control group, there were 34 males and 46 females, with an age of (42.14±8.73) years and a disease duration of (11.31±21.14) days;during the acute phase, patients in this group could take celecoxib capsules orally, and methylcobalamin orally at the same time. The Japanese Orthopaedic Association (JOA) score, Oswestry disability index (ODI), changes in the volume of herniated disc tissue on MRI, herniation rate, and absorption rate were recorded at the time of enrollment and during follow-ups at the 3rd, 6th, and 12th month after treatment.
RESULTS:
A total of 156 patients completed the clinical follow-up, and 4 patients withdrew midway. The clinical symptoms of all patients who completed the study were relieved to varying degrees, and reabsorption of herniated disc tissue was observed in all patients in the Yiqi Huoxue formula group after treatment. For the JOA score:in the Yiqi Huoxue formula group, it was (10.73±2.76) points before treatment and (24.65±2.19) points at the 12th month after treatment;in the control group, it was (11.01±1.20) points before treatment and (17.07±3.26) points at the 12th month after treatment. For the ODI score:in the Yiqi Huoxue formula group, it was (26.21±3.55) points before treatment and (5.65±2.19) points at the 12th month after treatment;in the control group, it was (27.92±2.51) points before treatment and (9.09±2.15) points at the 12th month after treatment. At the 12th month after treatment, the JOA and ODI scores of both groups were better than those before treatment, and the scores of the Yiqi Huoxue formula group were better than those of the control group, with statistically significant differences (P<0.05). In terms of the herniated disc volume and herniation rate on MRI, the Yiqi Huoxue formula group was superior to the control group, with statistically significant differences(P<0.05). Reabsorption occurred in 56.96%(45/79) of patients in the Yiqi Huoxue formula group, which was significantly higher than the 37.66%(29/77) in the control group.
CONCLUSION
After treatment with Yiqi Huoxue formula, patients with ruptured LDH show significant improvement in clinical symptoms and a marked reduction in the volume of herniated discs. During the follow-up period, no obvious adverse drug reactions are observed in patients, and no recurrence of symptoms is found at the last follow-up, indicating that the formula has safe and reliable efficacy.
Humans
;
Male
;
Female
;
Intervertebral Disc Displacement/drug therapy*
;
Adult
;
Drugs, Chinese Herbal/adverse effects*
;
Middle Aged
;
Lumbar Vertebrae
7.Analysis of the layout and shielding effectiveness of medical accelerator vaults
Yajing SONG ; Zengyun NIU ; Yongzhong MA ; Shihua TAO ; Zechen FENG
Chinese Journal of Radiological Health 2025;34(2):204-208
Objective To analyze the layout and shielding effectiveness of medical accelerator vaults, and to provide a reference for the layout, shielding design, and optimization of protection of medical accelerator vaults. Methods Four medical accelerator radiotherapy vaults were selected. The layouts of these vaults were compared with the layout requirements in the radiation therapy protection standards. For each vault, the dose rates at four points of interest outside the shielding were calculated, including the primary shielding area, secondary shielding area, maze outer wall, and lateral shielding area. These values were then compared with the actual measurements obtained using a dose rate meter. Results All four vaults were located on the ground floor of the building and included a maze, with the auxiliary rooms all placed outside the treatment rooms. However, one vault was not located at one end of the building, and in another vault, the control room was exposed to direct irradiation of the useful beam. The calculated dose rates outside the primary shielding area ranged from 0.04 μSv/h to 0.62 μSv/h, while the measured values ranged from 0.10 μSv/h to 0.66 μSv/h, with the measured values being higher than the calculated ones. The calculated dose rates outside the secondary shielding area ranged from
8.Application of boron-containing polyethylene as maze wall lining shielding for a 10 MV medical accelerator room
Yajing SONG ; Jing SU ; Shihua TAO ; Zechen FENG
Chinese Journal of Radiological Health 2025;34(1):73-76
Objective To evaluate the ambient dose equivalent rates of photons and neutrons inside and outside the door of a 10 MV accelerator room, and to report the shielding effect of boron-containing polyethylene as maze wall lining. Methods The ambient dose equivalent rates of photons and neutrons inside and outside the door of an accelerator room were taken as the research subject. The Kersey, Falcão, and modified Kersey methods were used to calculate the ambient dose equivalent rates of neutrons and neutron capture gamma rays inside and outside the door of the room before and after renovation. Measurements were made using an X-ray/γ-ray dose rate instrument and a neutron ambient dose equivalent rate meter. Calculated and measured results were compared. Results Before renovation, the measured neutron dose rate inside the door was 409 μSv/h, while the calculated values were 323 μSv/h (Kersey method), 428 μSv/h (Falcão method), and 219 μSv/h (modified Kersey method). The Falcão method yielded a value closest to the measured value, while the Kersey and the modified Kersey methods underestimated the value by 21% and 46%, respectively. After the installation of boron-containing polyethylene plates, the measured neutron dose rate inside the door was 190 μSv/h, with a 54% reduction. The neutron and photon ambient dose equivalent rates outside the door were 5.8 μSv/h and 6.0 μSv/h, respectively, before renovation, and 0.14 μSv/h and 1.6 μSv/h, respectively, after renovation. Conclusion For a 10 MV accelerator room, neutron shielding and protection measurements are necessary, especially for rooms with short mazes. The Falcão method provides the best estimate of neutron dose rates inside and outside the door. Using boron-containing polyethylene plates as maze wall lining is an economical and effective shielding method.
9.Multidisciplinary collaborative quality control management to improve the performance of biological safety cabinets in hospital
Tao SONG ; Yuanyuan WANG ; Yun TIAN ; Feng XU ; Jin TIAN
China Occupational Medicine 2025;52(3):349-352
Objective To evaluate the effect of a multidisciplinary collaborative quality control management (hereinafter referred to as "QC management") on improving the performance of biological safety cabinets in hospital. Methods A total of 63 ClassⅡbiological safety cabinets in active use at Peking University Third Hospital were selected as the study subjects using the before-after study mode. Conventional management was implemented on the biological safety cabinets from 2018 to 2021. QC management was used in 2022. The compliance of biological safety cabinets management norm and performance differences under the two models were compared. Results The median and the 25th and 75th percentiles [M(P25, P75)] of the service life among these 63 biological safety cabinets were 3 (1,6) years. The overall performance pass rate and inflow velocity pass rate of biological safety cabinets were higher in the QC management than that in the conventional management (90.5% vs 65.1%, 96.8% vs 84.1%, both P<0.05). However, there was no significant difference in downflow velocity, high-efficiency particulate air filter integrity, cleanliness, airflow smoke pattern, noise, and illumination pass rates of biosafety cabinets before and after the implementation of QC management (79.4% vs 88.9%, 90.5% vs 100.0%, 96.8% vs 100.0%, 85.7% vs 100.0%, 100.0% vs 100.0%, and 85.7% vs 96.8%, respectively; all P>0.05). Conclusion sQC management improves the standardization of biological safety cabinet management and key performance indicators in hospital.
10.Curcumin Ameliorates Cisplatin-Induced Cardiovascular Injuries by Upregulating ERK/p-ERK Expression in Rats.
Jun-Tao HAO ; Meng-Piao LIN ; Jin WANG ; Feng SONG ; Xiao-Jie BAI
Chinese journal of integrative medicine 2025;31(8):717-725
OBJECTIVE:
To investigate cisplatin-induced cardiovascular toxicity and explore the protective effects and potential mechanism of curcumin co-treatment.
METHODS:
Forty adult male Sprague-Dawley rats were numbered and randomly divided into control group, cisplatin group (7.5 mg/kg, once a week, for 2 weeks), curcumin group (200 mg/kg per day, for 2 weeks) and cisplatin+curcumin group (cisplatin 7.5 mg/kg, once a week, and curcumin 200 mg/kg per day for 2 weeks) by a random number table method, with 10 rats in each group. Cardiac and vascular morphology and functions were assessed using hematoxylin-eosin and Masson's trichrome staining, serum indexes detection, echocardiography, electrocardiogram (ECG), blood pressure monitoring, vascular ring isometric tension measurement, and left ventricular pressure evaluation. The expressions of extracellular signal-regulated kinases (ERK) and phosphorylated-ERK (p-ERK) were analyzed by immunohistochemical staining.
RESULTS:
Cisplatin treatment induced notable cardiac alteration, as evidenced by changes in cardiac morphology, elevated serum enzymes (P<0.05), ECG abnormalities, and increased left ventricular end-diastolic pressure (P<0.05). Meanwhile, cisplatin significantly increased arterial pulse pressure (P<0.01), primarily due to a decrease in diastolic blood pressure. Severe fibrosis was also observed in the thoracic aorta wall. In vascular ring experiments, cisplatin treatment led to a significant reduction in phenylephrine-induced contraction (P<0.05) and acetylcholine-induced relaxation (P<0.01). Notably, Curcumin co-administration significantly alleviated cisplatin-induced cardiovascular damages, as demonstrated by improvement in these parameters. Furthermore, ERK expression in the myocardium and p-ERK expression in vascular smooth muscle cells were significantly upregulated following curcumin co-treatment.
CONCLUSIONS
Curcumin protects the heart and vasculature from cisplatin-induced damages, likely by upregulating ERK/p-ERK expression. These findings suggest that curcumin may serve as a promising therapeutic strategy for mitigating cisplatin-associated cardiovascular toxicity during tumor chemotherapy. In vitro cell culture experiments are needed to clarify the underlying mechanism.
Animals
;
Curcumin/therapeutic use*
;
Cisplatin/adverse effects*
;
Rats, Sprague-Dawley
;
Male
;
Up-Regulation/drug effects*
;
Extracellular Signal-Regulated MAP Kinases/metabolism*
;
Phosphorylation/drug effects*
;
Electrocardiography
;
Blood Pressure/drug effects*
;
Rats
;
MAP Kinase Signaling System/drug effects*


Result Analysis
Print
Save
E-mail