1.Korean Thyroid Association Guidelines on the Management of Differentiated Thyroid Cancers; Part II. Follow-up Surveillance after Initial Treatment 2026
Eun Kyung LEE ; Seung Heon KANG ; Bon Seok KOO ; Mijin KIM ; Min Joo KIM ; Bo Hyun KIM ; Ji Won KIM ; Dong Gyu NA ; Sohyun PARK ; Ji-In BANG ; Kyorim BACK ; Youngduk SEO ; Young-Ik SON ; Young Shin SONG ; Dong Yeob SHIN ; Jong-Hyuk AHN ; Hwa Young AHN ; So Won OH ; Ho-Ryun WON ; Won Sang YOO ; Min Kyoung LEE ; Sang-Woo LEE ; Jeongmin LEE ; Ji Ye LEE ; Dong-Jun LIM ; Ki-Wook CHUNG ; Ari CHONG ; Jin Hyang JUNG ; Sun Wook CHO ; Yoon Young CHO ; Chae Moon HONG ; Young Joo PARK ;
International Journal of Thyroidology 2026;19(1):1-40
In patients with differentiated thyroid cancer (DTC), initial recurrence risk stratification based on clinical, histopathological, and perioperative data remains the key determinant for guiding management strategies during the first 1-2 years post-treatment. However, the adoption of ongoing risk stratification (ORS), which dynamically reassesses risk by integrating longitudinal clinical data and treatment response, enables more precise long-term prognostic assessment and facilitates highly individualized management. Building upon recent guidelines, the 2026 KTA guideline has been further refined by incorporating robust evidence from large-scale national cohorts and comprehensive systematic reviews. These updated recommendations outline contemporary concepts of ORS, risk-adapted TSH suppression targets, optimized surveillance modalities for recurrence detection, and disease-specific long-term follow-up strategies. Reflecting the paradigm shift toward de-escalated treatment, this revision integrates evolved perspectives on TSH suppression intensity, the clinical interpretation of thyroglobulin levels, and tailored follow-up intervals. These evidence-based recommendations aim to minimize unnecessary treatment and excessive surveillance in the large proportion of patients with excellent prognosis after initial therapy, while ensuring that each patient receives appropriately tailored and effective long-term management.
7.Intra-Fractional Dose Evaluation for Patients with Breast Cancer Using Synthetic Computed Tomography
Sohyun AHN ; So Eun CHOI ; Jeong-Heon KIM ; Kwangwoo PARK ; Hai-Jeon YOON
Progress in Medical Physics 2024;35(4):145-154
Purpose:
This study investigated the use of synthetic computed tomography (CT) images derived from cone beam CT (CBCT) scans to analyze dose changes in breast cancer patients undergoing treatment and to evaluate the optimal timing for implementing adaptive radiotherapy.
Methods:
A retrospective analysis was conducted on five breast cancer patients treated with tomotherapy-based volumetric-modulated arc therapy at Yongin Severance Hospital. Each patient received 15 fractions, with doses of 320 centigray (cGy) to the high-dose planning target volume (PTV) and 267 cGy to the low-dose PTV. Planning CT images were acquired using the Aquilion scanner, andCBCT images were captured with the VersaHD linear accelerator’s on-board imager. These imageswere registered in RayStation using a hybrid deformable image registration method to generate synthetic CT images. Dose distributions were reanalyzed using the synthetic CT images, and dose-volume histogram parameters, including the dose to 95% of the volume (D95 ) and mean dose (Dmean ) for the PTV, as well as D95 , Dmean , the percentage of the volume receiving at least 5 Gy (V5 ) and 10 Gy (V10 )for organs-at-risk (OARs), were extracted using MATLAB to assess dose changes during treatment.
Results:
For the original plans, the mean D95 for PTV high across all patients was 287.13±31.32cGy, while for PTV low, it was 245.53±6.21 cGy. In contrast, the adaptive plans yielded a mean D95of 298.17±12.37 cGy for PTV High and 247.25±4.23 cGy for PTV low. The ART Plan may lead to increased dose exposure in certain structures, such as the spinal cord, while providing targeted improvements in reducing radiation exposure in specific OARs (e.g., contralateral breast and esophagus).
Conclusions
Synthetic CT images generated from CBCT scans provide a fast and efficient means of quantifying dose changes, supporting precise patient care through interfractional evaluation.Future studies will aim to apply this method to other organs and larger patient cohorts.
8.Intra-Fractional Dose Evaluation for Patients with Breast Cancer Using Synthetic Computed Tomography
Sohyun AHN ; So Eun CHOI ; Jeong-Heon KIM ; Kwangwoo PARK ; Hai-Jeon YOON
Progress in Medical Physics 2024;35(4):145-154
Purpose:
This study investigated the use of synthetic computed tomography (CT) images derived from cone beam CT (CBCT) scans to analyze dose changes in breast cancer patients undergoing treatment and to evaluate the optimal timing for implementing adaptive radiotherapy.
Methods:
A retrospective analysis was conducted on five breast cancer patients treated with tomotherapy-based volumetric-modulated arc therapy at Yongin Severance Hospital. Each patient received 15 fractions, with doses of 320 centigray (cGy) to the high-dose planning target volume (PTV) and 267 cGy to the low-dose PTV. Planning CT images were acquired using the Aquilion scanner, andCBCT images were captured with the VersaHD linear accelerator’s on-board imager. These imageswere registered in RayStation using a hybrid deformable image registration method to generate synthetic CT images. Dose distributions were reanalyzed using the synthetic CT images, and dose-volume histogram parameters, including the dose to 95% of the volume (D95 ) and mean dose (Dmean ) for the PTV, as well as D95 , Dmean , the percentage of the volume receiving at least 5 Gy (V5 ) and 10 Gy (V10 )for organs-at-risk (OARs), were extracted using MATLAB to assess dose changes during treatment.
Results:
For the original plans, the mean D95 for PTV high across all patients was 287.13±31.32cGy, while for PTV low, it was 245.53±6.21 cGy. In contrast, the adaptive plans yielded a mean D95of 298.17±12.37 cGy for PTV High and 247.25±4.23 cGy for PTV low. The ART Plan may lead to increased dose exposure in certain structures, such as the spinal cord, while providing targeted improvements in reducing radiation exposure in specific OARs (e.g., contralateral breast and esophagus).
Conclusions
Synthetic CT images generated from CBCT scans provide a fast and efficient means of quantifying dose changes, supporting precise patient care through interfractional evaluation.Future studies will aim to apply this method to other organs and larger patient cohorts.
9.Intra-Fractional Dose Evaluation for Patients with Breast Cancer Using Synthetic Computed Tomography
Sohyun AHN ; So Eun CHOI ; Jeong-Heon KIM ; Kwangwoo PARK ; Hai-Jeon YOON
Progress in Medical Physics 2024;35(4):145-154
Purpose:
This study investigated the use of synthetic computed tomography (CT) images derived from cone beam CT (CBCT) scans to analyze dose changes in breast cancer patients undergoing treatment and to evaluate the optimal timing for implementing adaptive radiotherapy.
Methods:
A retrospective analysis was conducted on five breast cancer patients treated with tomotherapy-based volumetric-modulated arc therapy at Yongin Severance Hospital. Each patient received 15 fractions, with doses of 320 centigray (cGy) to the high-dose planning target volume (PTV) and 267 cGy to the low-dose PTV. Planning CT images were acquired using the Aquilion scanner, andCBCT images were captured with the VersaHD linear accelerator’s on-board imager. These imageswere registered in RayStation using a hybrid deformable image registration method to generate synthetic CT images. Dose distributions were reanalyzed using the synthetic CT images, and dose-volume histogram parameters, including the dose to 95% of the volume (D95 ) and mean dose (Dmean ) for the PTV, as well as D95 , Dmean , the percentage of the volume receiving at least 5 Gy (V5 ) and 10 Gy (V10 )for organs-at-risk (OARs), were extracted using MATLAB to assess dose changes during treatment.
Results:
For the original plans, the mean D95 for PTV high across all patients was 287.13±31.32cGy, while for PTV low, it was 245.53±6.21 cGy. In contrast, the adaptive plans yielded a mean D95of 298.17±12.37 cGy for PTV High and 247.25±4.23 cGy for PTV low. The ART Plan may lead to increased dose exposure in certain structures, such as the spinal cord, while providing targeted improvements in reducing radiation exposure in specific OARs (e.g., contralateral breast and esophagus).
Conclusions
Synthetic CT images generated from CBCT scans provide a fast and efficient means of quantifying dose changes, supporting precise patient care through interfractional evaluation.Future studies will aim to apply this method to other organs and larger patient cohorts.
10.Intra-Fractional Dose Evaluation for Patients with Breast Cancer Using Synthetic Computed Tomography
Sohyun AHN ; So Eun CHOI ; Jeong-Heon KIM ; Kwangwoo PARK ; Hai-Jeon YOON
Progress in Medical Physics 2024;35(4):145-154
Purpose:
This study investigated the use of synthetic computed tomography (CT) images derived from cone beam CT (CBCT) scans to analyze dose changes in breast cancer patients undergoing treatment and to evaluate the optimal timing for implementing adaptive radiotherapy.
Methods:
A retrospective analysis was conducted on five breast cancer patients treated with tomotherapy-based volumetric-modulated arc therapy at Yongin Severance Hospital. Each patient received 15 fractions, with doses of 320 centigray (cGy) to the high-dose planning target volume (PTV) and 267 cGy to the low-dose PTV. Planning CT images were acquired using the Aquilion scanner, andCBCT images were captured with the VersaHD linear accelerator’s on-board imager. These imageswere registered in RayStation using a hybrid deformable image registration method to generate synthetic CT images. Dose distributions were reanalyzed using the synthetic CT images, and dose-volume histogram parameters, including the dose to 95% of the volume (D95 ) and mean dose (Dmean ) for the PTV, as well as D95 , Dmean , the percentage of the volume receiving at least 5 Gy (V5 ) and 10 Gy (V10 )for organs-at-risk (OARs), were extracted using MATLAB to assess dose changes during treatment.
Results:
For the original plans, the mean D95 for PTV high across all patients was 287.13±31.32cGy, while for PTV low, it was 245.53±6.21 cGy. In contrast, the adaptive plans yielded a mean D95of 298.17±12.37 cGy for PTV High and 247.25±4.23 cGy for PTV low. The ART Plan may lead to increased dose exposure in certain structures, such as the spinal cord, while providing targeted improvements in reducing radiation exposure in specific OARs (e.g., contralateral breast and esophagus).
Conclusions
Synthetic CT images generated from CBCT scans provide a fast and efficient means of quantifying dose changes, supporting precise patient care through interfractional evaluation.Future studies will aim to apply this method to other organs and larger patient cohorts.

Result Analysis
Print
Save
E-mail