1.Successful Non-Operative Management of Middle Colic Artery Injury Using Transcatheter Arterial Embolization Performed in a Hybrid Emergency Room System
Joo Hyun LEE ; So Ra AHN ; Sang Hyun SEO ; Chan Yong PARK
Journal of Acute Care Surgery 2025;15(1):30-33
Mesenteric injuries from blunt trauma are rare, but can result in life-threatening complications, including massive hemorrhage from mesenteric arterial disruption, bowel ischemia, necrosis, and perforation. Prompt diagnosis and treatment are critical, and surgical intervention is traditionally considered the gold standard intervention. Although transcatheter arterial embolization (TAE) is an established treatment for solid organ injuries following blunt abdominal trauma, its application to mesenteric injuries is less common. A 47-year-old male was admitted to our trauma center, which employes a hybrid emergency room system, after falling from a height of 3 meters. Abdominal computed tomography revealed active contrast extravasation from the middle colic artery which had a large hemoperitoneum, but no evidence of bowel injury. After initial resuscitation and stabilization, TAE was performed to control the hemorrhage. The patient was discharged 42 days after admission without significant complications. As a possible treatment option for mesenteric injuries without intestinal damage, we suggest TAE.
2.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
3.Epidemiology and Functional Outcome of Acute Stroke Patients in Korea Using Nationwide data
Seungmin SHIN ; Young Woo KIM ; Seung Hun SHEEN ; Sukh Que PARK ; Sung-Chul JIN ; Jin Pyeong JEON ; Ji Young LEE ; Boung Chul LEE ; Young Wha LIM ; Gui Ok KIM ; Youg Uk KWON ; Yu Ra LEE ; So Young HAN ; Jae Sang OH
Journal of Korean Neurosurgical Society 2025;68(2):159-176
Objective:
: Korea’s healthcare system and policy promotes early, actively stroke treatment to improve prognosis. This study represents stroke epidemiology and outcomes in Korea.
Methods:
: This study investigated data from the Acute Stroke Assessment Registry. The registry collects data from over 220 hospitals nationwide, focusing on quality stroke service management. Data analysis included patient demographics, stroke severity assessment, and discharge prognosis measurement using standardized scales.
Results:
: Eighty-six thousand five hundred sixty-eight acute stroke patients were collected with demographic and clinical characteristics during 18 months from 2016, 2018, and between 2020 to 2021, focusing on acute subarachnoid hemorrhage (SAH), acute intracerebral hemorrhage (ICH), and acute ischemic stroke. Of these 86568 patients, 8.3% was SAH, 16.3% ICH, and 74.9% ischemic stroke. Trends showed decreasing SAH and increasing ICH cases over the years. 68.3% stroke patients had the clear onset time. 49.6% stroke patients arrived within 4.5 hours of symptom onset, with more patients treated at general hospitals. Good functional outcomes at discharge was obtained with 58.3% of acute stroke patients, 55.9% of SAH patients, 34.6% of ICH patients, and 63.8% of ischemic stroke patients.
Conclusion
: The results showed that ischemic stroke was the most common subtype, followed by ICH and SAH. Prognosis differed among subtypes, with favorable outcomes more common in ischemic stroke and SAH compared to ICH.
4.Epidemiology and Functional Outcome of Acute Stroke Patients in Korea Using Nationwide data
Seungmin SHIN ; Young Woo KIM ; Seung Hun SHEEN ; Sukh Que PARK ; Sung-Chul JIN ; Jin Pyeong JEON ; Ji Young LEE ; Boung Chul LEE ; Young Wha LIM ; Gui Ok KIM ; Youg Uk KWON ; Yu Ra LEE ; So Young HAN ; Jae Sang OH
Journal of Korean Neurosurgical Society 2025;68(2):159-176
Objective:
: Korea’s healthcare system and policy promotes early, actively stroke treatment to improve prognosis. This study represents stroke epidemiology and outcomes in Korea.
Methods:
: This study investigated data from the Acute Stroke Assessment Registry. The registry collects data from over 220 hospitals nationwide, focusing on quality stroke service management. Data analysis included patient demographics, stroke severity assessment, and discharge prognosis measurement using standardized scales.
Results:
: Eighty-six thousand five hundred sixty-eight acute stroke patients were collected with demographic and clinical characteristics during 18 months from 2016, 2018, and between 2020 to 2021, focusing on acute subarachnoid hemorrhage (SAH), acute intracerebral hemorrhage (ICH), and acute ischemic stroke. Of these 86568 patients, 8.3% was SAH, 16.3% ICH, and 74.9% ischemic stroke. Trends showed decreasing SAH and increasing ICH cases over the years. 68.3% stroke patients had the clear onset time. 49.6% stroke patients arrived within 4.5 hours of symptom onset, with more patients treated at general hospitals. Good functional outcomes at discharge was obtained with 58.3% of acute stroke patients, 55.9% of SAH patients, 34.6% of ICH patients, and 63.8% of ischemic stroke patients.
Conclusion
: The results showed that ischemic stroke was the most common subtype, followed by ICH and SAH. Prognosis differed among subtypes, with favorable outcomes more common in ischemic stroke and SAH compared to ICH.
5.Successful Non-Operative Management of Middle Colic Artery Injury Using Transcatheter Arterial Embolization Performed in a Hybrid Emergency Room System
Joo Hyun LEE ; So Ra AHN ; Sang Hyun SEO ; Chan Yong PARK
Journal of Acute Care Surgery 2025;15(1):30-33
Mesenteric injuries from blunt trauma are rare, but can result in life-threatening complications, including massive hemorrhage from mesenteric arterial disruption, bowel ischemia, necrosis, and perforation. Prompt diagnosis and treatment are critical, and surgical intervention is traditionally considered the gold standard intervention. Although transcatheter arterial embolization (TAE) is an established treatment for solid organ injuries following blunt abdominal trauma, its application to mesenteric injuries is less common. A 47-year-old male was admitted to our trauma center, which employes a hybrid emergency room system, after falling from a height of 3 meters. Abdominal computed tomography revealed active contrast extravasation from the middle colic artery which had a large hemoperitoneum, but no evidence of bowel injury. After initial resuscitation and stabilization, TAE was performed to control the hemorrhage. The patient was discharged 42 days after admission without significant complications. As a possible treatment option for mesenteric injuries without intestinal damage, we suggest TAE.
6.Epidemiology and Functional Outcome of Acute Stroke Patients in Korea Using Nationwide data
Seungmin SHIN ; Young Woo KIM ; Seung Hun SHEEN ; Sukh Que PARK ; Sung-Chul JIN ; Jin Pyeong JEON ; Ji Young LEE ; Boung Chul LEE ; Young Wha LIM ; Gui Ok KIM ; Youg Uk KWON ; Yu Ra LEE ; So Young HAN ; Jae Sang OH
Journal of Korean Neurosurgical Society 2025;68(2):159-176
Objective:
: Korea’s healthcare system and policy promotes early, actively stroke treatment to improve prognosis. This study represents stroke epidemiology and outcomes in Korea.
Methods:
: This study investigated data from the Acute Stroke Assessment Registry. The registry collects data from over 220 hospitals nationwide, focusing on quality stroke service management. Data analysis included patient demographics, stroke severity assessment, and discharge prognosis measurement using standardized scales.
Results:
: Eighty-six thousand five hundred sixty-eight acute stroke patients were collected with demographic and clinical characteristics during 18 months from 2016, 2018, and between 2020 to 2021, focusing on acute subarachnoid hemorrhage (SAH), acute intracerebral hemorrhage (ICH), and acute ischemic stroke. Of these 86568 patients, 8.3% was SAH, 16.3% ICH, and 74.9% ischemic stroke. Trends showed decreasing SAH and increasing ICH cases over the years. 68.3% stroke patients had the clear onset time. 49.6% stroke patients arrived within 4.5 hours of symptom onset, with more patients treated at general hospitals. Good functional outcomes at discharge was obtained with 58.3% of acute stroke patients, 55.9% of SAH patients, 34.6% of ICH patients, and 63.8% of ischemic stroke patients.
Conclusion
: The results showed that ischemic stroke was the most common subtype, followed by ICH and SAH. Prognosis differed among subtypes, with favorable outcomes more common in ischemic stroke and SAH compared to ICH.
7.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.
8.Successful Non-Operative Management of Middle Colic Artery Injury Using Transcatheter Arterial Embolization Performed in a Hybrid Emergency Room System
Joo Hyun LEE ; So Ra AHN ; Sang Hyun SEO ; Chan Yong PARK
Journal of Acute Care Surgery 2025;15(1):30-33
Mesenteric injuries from blunt trauma are rare, but can result in life-threatening complications, including massive hemorrhage from mesenteric arterial disruption, bowel ischemia, necrosis, and perforation. Prompt diagnosis and treatment are critical, and surgical intervention is traditionally considered the gold standard intervention. Although transcatheter arterial embolization (TAE) is an established treatment for solid organ injuries following blunt abdominal trauma, its application to mesenteric injuries is less common. A 47-year-old male was admitted to our trauma center, which employes a hybrid emergency room system, after falling from a height of 3 meters. Abdominal computed tomography revealed active contrast extravasation from the middle colic artery which had a large hemoperitoneum, but no evidence of bowel injury. After initial resuscitation and stabilization, TAE was performed to control the hemorrhage. The patient was discharged 42 days after admission without significant complications. As a possible treatment option for mesenteric injuries without intestinal damage, we suggest TAE.
9.Epidemiology and Functional Outcome of Acute Stroke Patients in Korea Using Nationwide data
Seungmin SHIN ; Young Woo KIM ; Seung Hun SHEEN ; Sukh Que PARK ; Sung-Chul JIN ; Jin Pyeong JEON ; Ji Young LEE ; Boung Chul LEE ; Young Wha LIM ; Gui Ok KIM ; Youg Uk KWON ; Yu Ra LEE ; So Young HAN ; Jae Sang OH
Journal of Korean Neurosurgical Society 2025;68(2):159-176
Objective:
: Korea’s healthcare system and policy promotes early, actively stroke treatment to improve prognosis. This study represents stroke epidemiology and outcomes in Korea.
Methods:
: This study investigated data from the Acute Stroke Assessment Registry. The registry collects data from over 220 hospitals nationwide, focusing on quality stroke service management. Data analysis included patient demographics, stroke severity assessment, and discharge prognosis measurement using standardized scales.
Results:
: Eighty-six thousand five hundred sixty-eight acute stroke patients were collected with demographic and clinical characteristics during 18 months from 2016, 2018, and between 2020 to 2021, focusing on acute subarachnoid hemorrhage (SAH), acute intracerebral hemorrhage (ICH), and acute ischemic stroke. Of these 86568 patients, 8.3% was SAH, 16.3% ICH, and 74.9% ischemic stroke. Trends showed decreasing SAH and increasing ICH cases over the years. 68.3% stroke patients had the clear onset time. 49.6% stroke patients arrived within 4.5 hours of symptom onset, with more patients treated at general hospitals. Good functional outcomes at discharge was obtained with 58.3% of acute stroke patients, 55.9% of SAH patients, 34.6% of ICH patients, and 63.8% of ischemic stroke patients.
Conclusion
: The results showed that ischemic stroke was the most common subtype, followed by ICH and SAH. Prognosis differed among subtypes, with favorable outcomes more common in ischemic stroke and SAH compared to ICH.
10.A Comparison between Keratograph 5M® and IDRA® in Dry Eye Patients
Seo Woo PARK ; Ha-Rim SO ; Ji Won BAEK ; Ho Sik HWANG ; Kyung-Sun NA ; Ho RA ; Nam Yeo KANG ; Hyun Seung KIM ; Eun Chul KIM
Journal of the Korean Ophthalmological Society 2025;66(4):175-180
Purpose:
To evaluate the compatibility and usability of test results obtained from the IDRA and Keratograph 5M in clinical settings by comparing their performance in patients with dry eye disease.
Methods:
From December 27 to 30, 2022, a study was conducted on 30 patients diagnosed with dry eye utilizing both the Keratograph 5M and IDRA devices. The parameters compared and analyzed included lipid layer thickness, tear meniscus height, tear film break-up time, and meibography. A paired t-test was used for statistical comparison. The lipid layer thickness in the Keratograph 5M was graded on a scale from 0 to 4 based on thickness.
Results:
No significant differences were found between the two devices in tear film break-up time, tear meniscus height, and meibography (p = 0.148, 0.072, 0.124, respectively). However, the tear lipid layer thickness measured by IDRA showed a proportional relationship with the grade assigned by the Keratograph 5M (Kendall R = 0.217, p = 0.037; Spearman R = 0.260, p = 0.045).
Conclusions
The IDRA device offers the advantage of performing multiple dry eye tests; simultaneously, thereby saving time compared to the Keratograph 5M. Both devices can be used compatibly with IDRA particularly advantageous for providing a numerical value for tear lipid layer thickness which enhances the convenience of dry eye diagnosis and treatment.

Result Analysis
Print
Save