1.Deep Learning-Accelerated Non-Contrast Abbreviated Liver MRI for Detecting Malignant Focal Hepatic Lesions: Dual-Center Validation
So Hyun PARK ; Moon Hyung CHOI ; Bohyun KIM ; Hyun-Soo LEE ; Sungjin YOON ; Young Joon LEE ; Dominik NICKEL ; Thomas BENKERT
Korean Journal of Radiology 2025;26(4):333-345
Objective:
To compare a deep learning (DL)-accelerated non-enhanced abbreviated MRI (AMRI DL) protocol with standard AMRI (AMRI STD) of the liver in terms of image quality and malignant focal lesion detection.
Materials and Methods:
This retrospective study included 155 consecutive patients (110 male; mean age 62.4 ± 11 years) from two sites who underwent standard liver MRI and additional AMRIDL sequences, specifically DL-accelerated single-shot fast-spin echo (SSFSE DL) and DL-accelerated diffusion-weighted imaging (DWIDL). Additional MRI phantom experiments assessed signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) values. Three reviewers evaluated AMRIDL and AMRI STD protocols for image quality using a five-point Likert scale and identified malignant hepatic lesions. Image quality scores and per-lesion sensitivities were compared between AMRIDL and AMRI STD using the Wilcoxon signed-rank test and logistic regression with generalized estimating equations, respectively.
Results:
Phantom experiments demonstrated comparable SNR and higher CNR for SSFSE DL compared to SSFSE STD, with similar ADC values for DWIDL and DWI STD. Among the 155 patients, 130 (83.9%) had chronic liver disease or a history of intra- or extrahepatic malignancy. Of 104 malignant focal lesions in 64 patients, 58 (55.8%) were hepatocellular carcinomas (HCCs), 38 (36.5%) were metastases, four (3.8%) were cholangiocarcinomas, and four (3.8%) were lymphomas. The pooled per-lesion sensitivity across three readers was 97.6% for AMRIDL, comparable to 97.6% for AMRI STD. Compared with AMRI STD, AMRIDL demonstrated superior image quality regarding structural sharpness, artifacts, and noise (all P < 0.001) and reduced the average scan time by approximately 50% (2 min 29 sec vs. 4 min 11 sec). In patients with chronic liver disease, AMRIDL achieved a 96.6% per-lesion sensitivity for HCC detection, similar to 96.5% for AMRI STD (P > 0.05).
Conclusion
The AMRIDL protocol offers comparable sensitivity for detecting malignant focal lesions, including HCC while significantly enhancing image quality and reducing scan time by approximately 50% compared to AMRI STD.
2.Deep Learning-Accelerated Non-Contrast Abbreviated Liver MRI for Detecting Malignant Focal Hepatic Lesions: Dual-Center Validation
So Hyun PARK ; Moon Hyung CHOI ; Bohyun KIM ; Hyun-Soo LEE ; Sungjin YOON ; Young Joon LEE ; Dominik NICKEL ; Thomas BENKERT
Korean Journal of Radiology 2025;26(4):333-345
Objective:
To compare a deep learning (DL)-accelerated non-enhanced abbreviated MRI (AMRI DL) protocol with standard AMRI (AMRI STD) of the liver in terms of image quality and malignant focal lesion detection.
Materials and Methods:
This retrospective study included 155 consecutive patients (110 male; mean age 62.4 ± 11 years) from two sites who underwent standard liver MRI and additional AMRIDL sequences, specifically DL-accelerated single-shot fast-spin echo (SSFSE DL) and DL-accelerated diffusion-weighted imaging (DWIDL). Additional MRI phantom experiments assessed signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) values. Three reviewers evaluated AMRIDL and AMRI STD protocols for image quality using a five-point Likert scale and identified malignant hepatic lesions. Image quality scores and per-lesion sensitivities were compared between AMRIDL and AMRI STD using the Wilcoxon signed-rank test and logistic regression with generalized estimating equations, respectively.
Results:
Phantom experiments demonstrated comparable SNR and higher CNR for SSFSE DL compared to SSFSE STD, with similar ADC values for DWIDL and DWI STD. Among the 155 patients, 130 (83.9%) had chronic liver disease or a history of intra- or extrahepatic malignancy. Of 104 malignant focal lesions in 64 patients, 58 (55.8%) were hepatocellular carcinomas (HCCs), 38 (36.5%) were metastases, four (3.8%) were cholangiocarcinomas, and four (3.8%) were lymphomas. The pooled per-lesion sensitivity across three readers was 97.6% for AMRIDL, comparable to 97.6% for AMRI STD. Compared with AMRI STD, AMRIDL demonstrated superior image quality regarding structural sharpness, artifacts, and noise (all P < 0.001) and reduced the average scan time by approximately 50% (2 min 29 sec vs. 4 min 11 sec). In patients with chronic liver disease, AMRIDL achieved a 96.6% per-lesion sensitivity for HCC detection, similar to 96.5% for AMRI STD (P > 0.05).
Conclusion
The AMRIDL protocol offers comparable sensitivity for detecting malignant focal lesions, including HCC while significantly enhancing image quality and reducing scan time by approximately 50% compared to AMRI STD.
3.Deep Learning-Accelerated Non-Contrast Abbreviated Liver MRI for Detecting Malignant Focal Hepatic Lesions: Dual-Center Validation
So Hyun PARK ; Moon Hyung CHOI ; Bohyun KIM ; Hyun-Soo LEE ; Sungjin YOON ; Young Joon LEE ; Dominik NICKEL ; Thomas BENKERT
Korean Journal of Radiology 2025;26(4):333-345
Objective:
To compare a deep learning (DL)-accelerated non-enhanced abbreviated MRI (AMRI DL) protocol with standard AMRI (AMRI STD) of the liver in terms of image quality and malignant focal lesion detection.
Materials and Methods:
This retrospective study included 155 consecutive patients (110 male; mean age 62.4 ± 11 years) from two sites who underwent standard liver MRI and additional AMRIDL sequences, specifically DL-accelerated single-shot fast-spin echo (SSFSE DL) and DL-accelerated diffusion-weighted imaging (DWIDL). Additional MRI phantom experiments assessed signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) values. Three reviewers evaluated AMRIDL and AMRI STD protocols for image quality using a five-point Likert scale and identified malignant hepatic lesions. Image quality scores and per-lesion sensitivities were compared between AMRIDL and AMRI STD using the Wilcoxon signed-rank test and logistic regression with generalized estimating equations, respectively.
Results:
Phantom experiments demonstrated comparable SNR and higher CNR for SSFSE DL compared to SSFSE STD, with similar ADC values for DWIDL and DWI STD. Among the 155 patients, 130 (83.9%) had chronic liver disease or a history of intra- or extrahepatic malignancy. Of 104 malignant focal lesions in 64 patients, 58 (55.8%) were hepatocellular carcinomas (HCCs), 38 (36.5%) were metastases, four (3.8%) were cholangiocarcinomas, and four (3.8%) were lymphomas. The pooled per-lesion sensitivity across three readers was 97.6% for AMRIDL, comparable to 97.6% for AMRI STD. Compared with AMRI STD, AMRIDL demonstrated superior image quality regarding structural sharpness, artifacts, and noise (all P < 0.001) and reduced the average scan time by approximately 50% (2 min 29 sec vs. 4 min 11 sec). In patients with chronic liver disease, AMRIDL achieved a 96.6% per-lesion sensitivity for HCC detection, similar to 96.5% for AMRI STD (P > 0.05).
Conclusion
The AMRIDL protocol offers comparable sensitivity for detecting malignant focal lesions, including HCC while significantly enhancing image quality and reducing scan time by approximately 50% compared to AMRI STD.
4.Prospective Multicenter Observational Study on Postoperative Quality of Life According to Type of Gastrectomy for Gastric Cancer
Sung Eun OH ; Yun-Suhk SUH ; Ji Yeong AN ; Keun Won RYU ; In CHO ; Sung Geun KIM ; Ji-Ho PARK ; Hoon HUR ; Hyung-Ho KIM ; Sang-Hoon AHN ; Sun-Hwi HWANG ; Hong Man YOON ; Ki Bum PARK ; Hyoung-Il KIM ; In Gyu KWON ; Han-Kwang YANG ; Byoung-Jo SUH ; Sang-Ho JEONG ; Tae-Han KIM ; Oh Kyoung KWON ; Hye Seong AHN ; Ji Yeon PARK ; Ki Young YOON ; Myoung Won SON ; Seong-Ho KONG ; Young-Gil SON ; Geum Jong SONG ; Jong Hyuk YUN ; Jung-Min BAE ; Do Joong PARK ; Sol LEE ; Jun-Young YANG ; Kyung Won SEO ; You-Jin JANG ; So Hyun KANG ; Bang Wool EOM ; Joongyub LEE ; Hyuk-Joon LEE ;
Journal of Gastric Cancer 2025;25(2):382-399
Purpose:
This study evaluated the postoperative quality of life (QoL) after various types of gastrectomy for gastric cancer.
Materials and Methods:
A multicenter prospective observational study was conducted in Korea using the Korean Quality of Life in Stomach Cancer Patients Study (KOQUSS)-40, a new QoL assessment tool focusing on postgastrectomy syndrome. Overall, 496 patients with gastric cancer were enrolled, and QoL was assessed at 5 time points: preoperatively and at 1, 3, 6, and 12 months after surgery.
Results:
Distal gastrectomy (DG) and pylorus-preserving gastrectomy (PPG) showed significantly better outcomes than total gastrectomy (TG) and proximal gastrectomy (PG) with regard to total score, indigestion, and dysphagia. DG, PPG, and TG also showed significantly better outcomes than PG in terms of dumping syndrome and worry about cancer. Postoperative QoL did not differ significantly according to anastomosis type in DG, except for Billroth I anastomosis, which achieved better bowel habit change scores than the others. No domains differed significantly when comparing double tract reconstruction and esophagogastrostomy after PG. The total QoL score correlated significantly with postoperative body weight loss (more than 10%) and extent of resection (P<0.05 for both).Reflux as assessed by KOQUSS-40 did not correlate significantly with reflux observed on gastroscopy 1 year postoperatively (P=0.064).
Conclusions
Our prospective observation using KOQUSS-40 revealed that DG and PPG lead to better QoL than TG and PG. Further study is needed to compare postoperative QoL according to anastomosis type in DG and PG.
5.Prospective Multicenter Observational Study on Postoperative Quality of Life According to Type of Gastrectomy for Gastric Cancer
Sung Eun OH ; Yun-Suhk SUH ; Ji Yeong AN ; Keun Won RYU ; In CHO ; Sung Geun KIM ; Ji-Ho PARK ; Hoon HUR ; Hyung-Ho KIM ; Sang-Hoon AHN ; Sun-Hwi HWANG ; Hong Man YOON ; Ki Bum PARK ; Hyoung-Il KIM ; In Gyu KWON ; Han-Kwang YANG ; Byoung-Jo SUH ; Sang-Ho JEONG ; Tae-Han KIM ; Oh Kyoung KWON ; Hye Seong AHN ; Ji Yeon PARK ; Ki Young YOON ; Myoung Won SON ; Seong-Ho KONG ; Young-Gil SON ; Geum Jong SONG ; Jong Hyuk YUN ; Jung-Min BAE ; Do Joong PARK ; Sol LEE ; Jun-Young YANG ; Kyung Won SEO ; You-Jin JANG ; So Hyun KANG ; Bang Wool EOM ; Joongyub LEE ; Hyuk-Joon LEE ;
Journal of Gastric Cancer 2025;25(2):382-399
Purpose:
This study evaluated the postoperative quality of life (QoL) after various types of gastrectomy for gastric cancer.
Materials and Methods:
A multicenter prospective observational study was conducted in Korea using the Korean Quality of Life in Stomach Cancer Patients Study (KOQUSS)-40, a new QoL assessment tool focusing on postgastrectomy syndrome. Overall, 496 patients with gastric cancer were enrolled, and QoL was assessed at 5 time points: preoperatively and at 1, 3, 6, and 12 months after surgery.
Results:
Distal gastrectomy (DG) and pylorus-preserving gastrectomy (PPG) showed significantly better outcomes than total gastrectomy (TG) and proximal gastrectomy (PG) with regard to total score, indigestion, and dysphagia. DG, PPG, and TG also showed significantly better outcomes than PG in terms of dumping syndrome and worry about cancer. Postoperative QoL did not differ significantly according to anastomosis type in DG, except for Billroth I anastomosis, which achieved better bowel habit change scores than the others. No domains differed significantly when comparing double tract reconstruction and esophagogastrostomy after PG. The total QoL score correlated significantly with postoperative body weight loss (more than 10%) and extent of resection (P<0.05 for both).Reflux as assessed by KOQUSS-40 did not correlate significantly with reflux observed on gastroscopy 1 year postoperatively (P=0.064).
Conclusions
Our prospective observation using KOQUSS-40 revealed that DG and PPG lead to better QoL than TG and PG. Further study is needed to compare postoperative QoL according to anastomosis type in DG and PG.
6.Deep Learning-Accelerated Non-Contrast Abbreviated Liver MRI for Detecting Malignant Focal Hepatic Lesions: Dual-Center Validation
So Hyun PARK ; Moon Hyung CHOI ; Bohyun KIM ; Hyun-Soo LEE ; Sungjin YOON ; Young Joon LEE ; Dominik NICKEL ; Thomas BENKERT
Korean Journal of Radiology 2025;26(4):333-345
Objective:
To compare a deep learning (DL)-accelerated non-enhanced abbreviated MRI (AMRI DL) protocol with standard AMRI (AMRI STD) of the liver in terms of image quality and malignant focal lesion detection.
Materials and Methods:
This retrospective study included 155 consecutive patients (110 male; mean age 62.4 ± 11 years) from two sites who underwent standard liver MRI and additional AMRIDL sequences, specifically DL-accelerated single-shot fast-spin echo (SSFSE DL) and DL-accelerated diffusion-weighted imaging (DWIDL). Additional MRI phantom experiments assessed signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) values. Three reviewers evaluated AMRIDL and AMRI STD protocols for image quality using a five-point Likert scale and identified malignant hepatic lesions. Image quality scores and per-lesion sensitivities were compared between AMRIDL and AMRI STD using the Wilcoxon signed-rank test and logistic regression with generalized estimating equations, respectively.
Results:
Phantom experiments demonstrated comparable SNR and higher CNR for SSFSE DL compared to SSFSE STD, with similar ADC values for DWIDL and DWI STD. Among the 155 patients, 130 (83.9%) had chronic liver disease or a history of intra- or extrahepatic malignancy. Of 104 malignant focal lesions in 64 patients, 58 (55.8%) were hepatocellular carcinomas (HCCs), 38 (36.5%) were metastases, four (3.8%) were cholangiocarcinomas, and four (3.8%) were lymphomas. The pooled per-lesion sensitivity across three readers was 97.6% for AMRIDL, comparable to 97.6% for AMRI STD. Compared with AMRI STD, AMRIDL demonstrated superior image quality regarding structural sharpness, artifacts, and noise (all P < 0.001) and reduced the average scan time by approximately 50% (2 min 29 sec vs. 4 min 11 sec). In patients with chronic liver disease, AMRIDL achieved a 96.6% per-lesion sensitivity for HCC detection, similar to 96.5% for AMRI STD (P > 0.05).
Conclusion
The AMRIDL protocol offers comparable sensitivity for detecting malignant focal lesions, including HCC while significantly enhancing image quality and reducing scan time by approximately 50% compared to AMRI STD.
7.Prospective Multicenter Observational Study on Postoperative Quality of Life According to Type of Gastrectomy for Gastric Cancer
Sung Eun OH ; Yun-Suhk SUH ; Ji Yeong AN ; Keun Won RYU ; In CHO ; Sung Geun KIM ; Ji-Ho PARK ; Hoon HUR ; Hyung-Ho KIM ; Sang-Hoon AHN ; Sun-Hwi HWANG ; Hong Man YOON ; Ki Bum PARK ; Hyoung-Il KIM ; In Gyu KWON ; Han-Kwang YANG ; Byoung-Jo SUH ; Sang-Ho JEONG ; Tae-Han KIM ; Oh Kyoung KWON ; Hye Seong AHN ; Ji Yeon PARK ; Ki Young YOON ; Myoung Won SON ; Seong-Ho KONG ; Young-Gil SON ; Geum Jong SONG ; Jong Hyuk YUN ; Jung-Min BAE ; Do Joong PARK ; Sol LEE ; Jun-Young YANG ; Kyung Won SEO ; You-Jin JANG ; So Hyun KANG ; Bang Wool EOM ; Joongyub LEE ; Hyuk-Joon LEE ;
Journal of Gastric Cancer 2025;25(2):382-399
Purpose:
This study evaluated the postoperative quality of life (QoL) after various types of gastrectomy for gastric cancer.
Materials and Methods:
A multicenter prospective observational study was conducted in Korea using the Korean Quality of Life in Stomach Cancer Patients Study (KOQUSS)-40, a new QoL assessment tool focusing on postgastrectomy syndrome. Overall, 496 patients with gastric cancer were enrolled, and QoL was assessed at 5 time points: preoperatively and at 1, 3, 6, and 12 months after surgery.
Results:
Distal gastrectomy (DG) and pylorus-preserving gastrectomy (PPG) showed significantly better outcomes than total gastrectomy (TG) and proximal gastrectomy (PG) with regard to total score, indigestion, and dysphagia. DG, PPG, and TG also showed significantly better outcomes than PG in terms of dumping syndrome and worry about cancer. Postoperative QoL did not differ significantly according to anastomosis type in DG, except for Billroth I anastomosis, which achieved better bowel habit change scores than the others. No domains differed significantly when comparing double tract reconstruction and esophagogastrostomy after PG. The total QoL score correlated significantly with postoperative body weight loss (more than 10%) and extent of resection (P<0.05 for both).Reflux as assessed by KOQUSS-40 did not correlate significantly with reflux observed on gastroscopy 1 year postoperatively (P=0.064).
Conclusions
Our prospective observation using KOQUSS-40 revealed that DG and PPG lead to better QoL than TG and PG. Further study is needed to compare postoperative QoL according to anastomosis type in DG and PG.
8.Deep Learning-Accelerated Non-Contrast Abbreviated Liver MRI for Detecting Malignant Focal Hepatic Lesions: Dual-Center Validation
So Hyun PARK ; Moon Hyung CHOI ; Bohyun KIM ; Hyun-Soo LEE ; Sungjin YOON ; Young Joon LEE ; Dominik NICKEL ; Thomas BENKERT
Korean Journal of Radiology 2025;26(4):333-345
Objective:
To compare a deep learning (DL)-accelerated non-enhanced abbreviated MRI (AMRI DL) protocol with standard AMRI (AMRI STD) of the liver in terms of image quality and malignant focal lesion detection.
Materials and Methods:
This retrospective study included 155 consecutive patients (110 male; mean age 62.4 ± 11 years) from two sites who underwent standard liver MRI and additional AMRIDL sequences, specifically DL-accelerated single-shot fast-spin echo (SSFSE DL) and DL-accelerated diffusion-weighted imaging (DWIDL). Additional MRI phantom experiments assessed signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) values. Three reviewers evaluated AMRIDL and AMRI STD protocols for image quality using a five-point Likert scale and identified malignant hepatic lesions. Image quality scores and per-lesion sensitivities were compared between AMRIDL and AMRI STD using the Wilcoxon signed-rank test and logistic regression with generalized estimating equations, respectively.
Results:
Phantom experiments demonstrated comparable SNR and higher CNR for SSFSE DL compared to SSFSE STD, with similar ADC values for DWIDL and DWI STD. Among the 155 patients, 130 (83.9%) had chronic liver disease or a history of intra- or extrahepatic malignancy. Of 104 malignant focal lesions in 64 patients, 58 (55.8%) were hepatocellular carcinomas (HCCs), 38 (36.5%) were metastases, four (3.8%) were cholangiocarcinomas, and four (3.8%) were lymphomas. The pooled per-lesion sensitivity across three readers was 97.6% for AMRIDL, comparable to 97.6% for AMRI STD. Compared with AMRI STD, AMRIDL demonstrated superior image quality regarding structural sharpness, artifacts, and noise (all P < 0.001) and reduced the average scan time by approximately 50% (2 min 29 sec vs. 4 min 11 sec). In patients with chronic liver disease, AMRIDL achieved a 96.6% per-lesion sensitivity for HCC detection, similar to 96.5% for AMRI STD (P > 0.05).
Conclusion
The AMRIDL protocol offers comparable sensitivity for detecting malignant focal lesions, including HCC while significantly enhancing image quality and reducing scan time by approximately 50% compared to AMRI STD.
9.Radiologic Insertion of a Covered Esophageal Stent Using the Rendezvous Technique: A Case Report
Yoojin PARK ; Suyoung PARK ; Jung Han HWANG ; Jeong Ho KIM ; So Hyun PARK
Journal of the Korean Society of Radiology 2024;85(4):780-784
In this report, we present a case of a radiotherapy-induced tracheoesophageal fistula treated with the fluoroscopy-guided insertion of a covered stent through the gastrostomy route using both the antegrade and retrograde approaches. The initial antegrade endoscopic and fluoroscopic stent insertion procedure failed due to severe esophageal stricture. Compared to the endoscopic approaches, fluoroscopy-guided radiologic procedures are generally less invasive and more successful because they allow for a better understanding of the anatomy outside the lumen during the procedure and enable the use of devices with smaller diameters.
10.Advanced Abdominal MRI Techniques and Problem-Solving Strategies
Yoonhee LEE ; Sungjin YOON ; So Hyun PARK ; Marcel Dominik NICKEL
Journal of the Korean Society of Radiology 2024;85(2):345-362
MRI plays an important role in abdominal imaging because of its ability to detect and characterize focal lesions. However, MRI examinations have several challenges, such as comparatively long scan times and motion management through breath-holding maneuvers. Techniques for reducing scan time with acceptable image quality, such as parallel imaging, compressed sensing, and cutting-edge deep learning techniques, have been developed to enable problem-solving strategies. Additionally, free-breathing techniques for dynamic contrast-enhanced imaging, such as extra-dimensional-volumetric interpolated breath-hold examination, golden-angle radial sparse parallel, and liver acceleration volume acquisition Star, can help patients with severe dyspnea or those under sedation to undergo abdominal MRI. We aimed to present various advanced abdominal MRI techniques for reducing the scan time while maintaining image quality and free-breathing techniques for dynamic imaging and illustrate cases using the techniques mentioned above. A review of these advanced techniques can assist in the appropriate interpretation of sequences.

Result Analysis
Print
Save
E-mail