1.Current status and outlooks of acupuncture research driven by machine learning.
Sixian WU ; Linna WU ; Yi HU ; Zhijie XU ; Fan XU ; Hanbo YU ; Guiping LI
Chinese Acupuncture & Moxibustion 2025;45(4):421-427
The machine learning is used increasingly and widely in acupuncture prescription optimization, intelligent treatment and precision medicine, and has obtained a certain achievement. But, there are still some problems remained to be solved such as the poor interpretability of the model, the inconsistency of data quality of acupuncture research, and the clinical application of constructed models. Researches in future should focus on the acquisition of high-quality clinical and experimental data sets, take various machine learning algorithms as the basis, and construct professional models to solve various problems, so as to drive the high-quality development of acupuncture research.
Acupuncture Therapy/trends*
;
Machine Learning
;
Humans
;
Algorithms
2.Comparison of Acute Hemodynamics,Left Ventricular Fluid and Energy Losses Between Different Pacing Sites of the Cardiac Conduction System in Beagles
Yiran HU ; Han JIN ; Hui LI ; Sijing CHENG ; Sixian WENG ; Hao HUANG ; Juwei YANG ; Yu YU ; Ligang DING ; Min GU ; Hongxia NIU ; Wei HUA
Chinese Circulation Journal 2025;40(1):82-89
Objectives:Comparative analysis of the beagles acute-phase electrocardiographic,hemodynamic,left ventricular flow field status,and energy consumption characteristics of pacing at different sites of conduction system may help to elucidate the scientific mechanism of left bundle branch pacing(LBBP)as a option of physiological pacing therapy.Methods:Eight healthy adult beagles were used in this study.Initially,an active fixation lead was implanted in the right atrial appendage,followed by implantation of another active fixation lead at the right ventricular apex,distal His bundle,and left bundle septal branch,respectively.After connecting a dual-chamber pacemaker,electrocardiographic and acute phase hemodynamic parameters under sinus rhythm,right ventricular apex pacing(RVAP),distal His bundle pacing(DHBP),and LBBP states were collected and analyzed.Three complete cardiac cycles of standard apical three-chamber color Doppler dynamic images were acquired under vector flow mapping(VFM)mode.Offline analysis was performed on obtained parameters including isovolumic contraction period,rapid ejection period,isovolumic relaxation period,rapid filling period,atrial contraction period,and left ventricular intracavitary energy consumption.These parameters were compared under pacing at different sites and the linear correlations of major parameters were analyzed.Results:The QRS duration of baseline intrinsic sinus rhythm,RVAP,DHBP and LBBP were(45.0±4.0)ms,(98.4±6.2)ms,(50.0±4.5)ms and(62.0±4.7)ms,respectively.The LBBP-QRS duration was significantly wider than intrinsic sinus rhythm and DHBP,but significantly narrower than RVAP(all P<0.01).Compared with baseline AOO mode(the pacing rate was performed at 10 beats/min above the intrinsic heart rate),the change of acute phase maximum left ventricular pressure rise rate(LVdP/dtmax)in RVAP,DHBP and LBBP was([-7.89±5.67]% ),([0.74±2.05]% )and([-0.14±3.59]% ),respectively.There was no significant difference in LVdP/dtmax changes between DHBP and LBBP(P=0.667),but both pacing modalities were significantly better than RVAP(all P<0.01).The average energy consumption of the left ventricle under RVAP was significantly higher than that of intrinsic sinus rhythm,DHBP,and LBBP in isovolumic contraction period,rapid ejection period,isovolumic relaxation period,rapid filling period,and atrial contraction period(all P<0.01).However,there was no statistically significant difference in energy consumption among intrinsic sinus rhythm,DHBP,and LBBP during the above five phases(all P>0.05).DHBP and LBBP did not show a significant increase in the number of left ventricular vortices,vortex area,and circulation intensity compared to intrinsic sinus rhythm,and LBBP did not show a significant increase in vortex area and circulation intensity compared to DHBP.Conclusions:Although LBBP canines significantly prolonged the paced QRS duration,it showed no significant differences in acute phase left ventricular hemodynamics,left ventricular flow field status,and energy consumption compared to intrinsic sinus rhythm and DHBP.Performance of LBBP was superior to RVAP.This study may contribute to revealing the theoretical basis of LBBP as a feasible physiological pacing therapy.
3.Comparison of Acute Hemodynamics,Left Ventricular Fluid and Energy Losses Between Different Pacing Sites of the Cardiac Conduction System in Beagles
Yiran HU ; Han JIN ; Hui LI ; Sijing CHENG ; Sixian WENG ; Hao HUANG ; Juwei YANG ; Yu YU ; Ligang DING ; Min GU ; Hongxia NIU ; Wei HUA
Chinese Circulation Journal 2025;40(1):82-89
Objectives:Comparative analysis of the beagles acute-phase electrocardiographic,hemodynamic,left ventricular flow field status,and energy consumption characteristics of pacing at different sites of conduction system may help to elucidate the scientific mechanism of left bundle branch pacing(LBBP)as a option of physiological pacing therapy.Methods:Eight healthy adult beagles were used in this study.Initially,an active fixation lead was implanted in the right atrial appendage,followed by implantation of another active fixation lead at the right ventricular apex,distal His bundle,and left bundle septal branch,respectively.After connecting a dual-chamber pacemaker,electrocardiographic and acute phase hemodynamic parameters under sinus rhythm,right ventricular apex pacing(RVAP),distal His bundle pacing(DHBP),and LBBP states were collected and analyzed.Three complete cardiac cycles of standard apical three-chamber color Doppler dynamic images were acquired under vector flow mapping(VFM)mode.Offline analysis was performed on obtained parameters including isovolumic contraction period,rapid ejection period,isovolumic relaxation period,rapid filling period,atrial contraction period,and left ventricular intracavitary energy consumption.These parameters were compared under pacing at different sites and the linear correlations of major parameters were analyzed.Results:The QRS duration of baseline intrinsic sinus rhythm,RVAP,DHBP and LBBP were(45.0±4.0)ms,(98.4±6.2)ms,(50.0±4.5)ms and(62.0±4.7)ms,respectively.The LBBP-QRS duration was significantly wider than intrinsic sinus rhythm and DHBP,but significantly narrower than RVAP(all P<0.01).Compared with baseline AOO mode(the pacing rate was performed at 10 beats/min above the intrinsic heart rate),the change of acute phase maximum left ventricular pressure rise rate(LVdP/dtmax)in RVAP,DHBP and LBBP was([-7.89±5.67]% ),([0.74±2.05]% )and([-0.14±3.59]% ),respectively.There was no significant difference in LVdP/dtmax changes between DHBP and LBBP(P=0.667),but both pacing modalities were significantly better than RVAP(all P<0.01).The average energy consumption of the left ventricle under RVAP was significantly higher than that of intrinsic sinus rhythm,DHBP,and LBBP in isovolumic contraction period,rapid ejection period,isovolumic relaxation period,rapid filling period,and atrial contraction period(all P<0.01).However,there was no statistically significant difference in energy consumption among intrinsic sinus rhythm,DHBP,and LBBP during the above five phases(all P>0.05).DHBP and LBBP did not show a significant increase in the number of left ventricular vortices,vortex area,and circulation intensity compared to intrinsic sinus rhythm,and LBBP did not show a significant increase in vortex area and circulation intensity compared to DHBP.Conclusions:Although LBBP canines significantly prolonged the paced QRS duration,it showed no significant differences in acute phase left ventricular hemodynamics,left ventricular flow field status,and energy consumption compared to intrinsic sinus rhythm and DHBP.Performance of LBBP was superior to RVAP.This study may contribute to revealing the theoretical basis of LBBP as a feasible physiological pacing therapy.
4.Research on the application of artificial intelligence compressed sensing technology in three-dimensional proton density weighted imaging of the unilateral hip joint
Daoen ZHANG ; Xu XU ; Hanyu LI ; Sixian HU ; Ye YUAN ; Gaofeng ZHANG ; Xiaoyong ZHANG ; Chunchao XIA ; Zhenlin LI
Chinese Journal of Radiology 2024;58(12):1431-1436
Objective:To explore the impact of artificial intelligence compressed sensing technology (CS-AI) on image quality in three-dimensional proton density weighted imaging (3D PDWI) of the unilateral hip joint.Methods:High-resolution unilateral hip imaging was conducted on 67 healthy volunteers at West China Hospital of Sichuan University from January to July 2023. Imaging was performed by using CS-AI 3D PDWI sequence with acceleration factors (AF) of 4, 6, 8, and 10, respectively. According to the AF, all subjects were divided into 4 groups: CS-AI 4, CS-AI 6, CS-AI 8 and CS-AI 10, with CS-AI 4 serving as a reference. Recording the scan time, the signal and noise intensity of the femoral head, muscle, and subcutaneous fat were measured by a senior radiologist and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were then calculated. Additionally, two observers provided ratings for overall image quality and artifacts in the 4 groups, and statistical analysis was performed using the Friedman rank-sum test.Results:The acquisition times for CS-AI 4, CS-AI 6, CS-AI 8, and CS-AI 10 were 5 min 49 s, 3 min 54 s, 2 min 56 s and 2 min 22 s, respectively. Compared to CS-AI 4, the scanning time for CS-AI 6, CS-AI 8, CS-AI 10 were reduced by 32.95%, 50.14%, 59.31%, respectively. The objective evaluation revealed that the SNR and CNR of the femoral head and muscle in groups CS-AI 6, CS-AI 8, and CS-AI 10 were slightly lower than those in group CS-AI 4 ( P<0.05), and the differences were statistically significant. However, no statistically significant differences were found among the 3 groups ( P>0.05). The subjective evaluation indicated that the overall image quality scores of group CS-AI 8 [3 (3,4)] did not significantly differ from those of group CS-AI 4 and CS-AI 6( P>0.05); The mean scores of group CS-AI 4 and CS-AI 6 were 4 (4, 4); Scores of group CS-AI 10 was 3(3, 3), which statistically significant differ from those of the other groups ( P<0.05). The artifacts rating for groups CS-AI 4, CS-AI 6, CS-AI 8 and CS-AI 10 were 4 (4, 4), 4 (4, 4), 3 (3, 4), and 2 (2, 3) respectively. When AF was set to 10, the images exhibited the most severe artifacts ( P<0.05). For other AF values, artifact ratings did not differ significantly ( P>0.05). Conclusion:The CS-AI 3D-PDWI sequence with acceleration factor 8 can acquire high-resolution images of the unilateral hip joint that meet clinical diagnostic requirements while reducing scanning time.
5.Development and application of the Adolescent Mental Health Literacy Assessment Questionnaire among medical undergraduates
Chinese Journal of School Health 2021;42(7):1038-1041
Objective:
To develop the Adolescent Mental Health Literacy Assessment Questionnaire (AMHLAQ), and to evaluate its reliability and validity among undergraduates.
Methods:
On the basis of the definition of mental health literacy (MHL) and the Knowledge, Attitudes and Practices (KAP) theory, this study constructed a total of 36 items consisting of four dimensions, and scores were measured according to a five point Likert type scale. Using a cluster sampling method, a questionnaire survey was conducted among 3 826 freshmen and sophomore students from two medical schools in Anhui Province. The items were screened by performing t tests, Pearson s correlation coefficient analysis and factor analysis. The reliability and validity of the questionnaire were evaluated using indicators including homogeneity reliability, the split half reliability coefficient, and construct validity.
Results:
Factor analysis revealed that the AMHLAQ consisted of 22 questions grouped into four domains. The variance cumulative contribution rate was 62.213%. The reliability result showed that the Cronbach s alpha coefficient of the total questionnaire was 0.897, the split half reliability was 0.800, the Cronbach s coefficient of each dimension was 0.796 to 0.885, the split half reliability of each dimension was 0.725 to 0.846, and the indicators had a high level of reliability. Confirmatory factor analysis showed that the model fit was good ( χ 2/df =19.319, P <0.01; RMSEA=0.069).
Conclusion
AMHLAQ is consistent with the evaluation standard of psychometrics, has good reliability and validity, and can be used to estimate the level of MHL among undergraduates.
6.Application of dual-source CT combined with intelligent modulation and iterative reconstruction in aortic dissection imaging
Jin PU ; Chunchao XIA ; Fei ZHAO ; Lei LI ; Kai ZHANG ; Yuming LI ; Wanlin PENG ; Jinge ZHANG ; Keling LIU ; Xu XU ; Sixian HU ; Zhenlin LI
Chinese Journal of Radiological Medicine and Protection 2019;39(1):6-10
Objective To explore the clinical application value of second-generation dual-source CT combined with intelligent modulation and iterative reconstruction in emergency aortic dissection imaging.Methods A total of 40 emergency patients with clinical suspected aortic dissection were included in this study.Conventional scanning was performed in the control group,and large-pitch intelligent modulation and iterative reconstruction were performed in the test group.The mean CT value,mean noise,signal noise ratio(SNR),contrast noise ratio(CNR),effective dose,image quality and aortic root image quality were evaluated and analyzed.Results Totally 40 patients successfully completed CT aortic dissection imaging.There was no difference in image quality between the two groups (P> 0.05).The quality of aortic root images in the test group was better than that in the control group,and the difference was statistically significant(x2=22.556,P<0.05).The mean CT value and mean noise of aorta in the control group were slightly higher than those in the test group.However,SNR and CNR in the test group were higher than those in the control group,and the difference was statistically significant (t =-21.042,-15.924,8.530,11.495,P<0.05).The effective dose of the control group [(10.59±3.89)mSv] was significantly higher than that [(6.39±0.81) mSv] of the test group,the difference was statistically significant (t =-12.327,P<0.05).Conclusions The combined intelligent modulation technique and iterative reconstruction technique with dual-source CT large pitch scanning can meet the requirements of image quality and reduce the effective dose,and can be used as a conventional imaging method for emergency CT of aortic dissection.


Result Analysis
Print
Save
E-mail