1.Gene Expression Alteration by Non-thermal Plasma-Activated Media Treatment in Radioresistant Head and Neck Squamous Cell Carcinoma
Sicong ZHENG ; Yudan PIAO ; Seung-Nam JUNG ; Chan OH ; Mi Ae LIM ; QuocKhanh NGUYEN ; Shan SHEN ; Se-Hee PARK ; Shengzhe CUI ; Shuyu PIAO ; Young Il KIM ; Ji Won KIM ; Ho-Ryun WON ; Jae Won CHANG ; Yujuan SHAN ; Lihua LIU ; Bon Seok KOO
Clinical and Experimental Otorhinolaryngology 2025;18(1):73-87
Objectives:
. Head and neck squamous cell carcinoma (HNSCC) exhibits high recurrence rates, particularly in cases of radioresistant HNSCC (RR-HNSCC). Non-thermal plasma (NTP) therapy effectively suppresses the progression of HNSCC. However, the therapeutic mechanisms of NTP therapy in treating RR-HNSCC are not well understood. In this study, we explored the regulatory role of NTP in the RR-HNSCC signaling pathway and identified its signature genes.
Methods:
. After constructing two RR-HNSCC cell lines, we prepared cell lysates from cells treated or not treated with NTP-activated media (NTPAM) and performed RNA sequencing to determine their mRNA expression profiles. Based on the RNA sequencing results, we identified differentially expressed genes (DEGs), followed by a bioinformatics analysis to identify candidate molecules potentially associated with NTPAM therapy for RR-HNSCC.
Results:
. NTPAM reduced RR-HNSCC cell viability in vitro. RNA sequencing results indicated that NTPAM treatment activated the reactive oxygen species (ROS) pathway and induced ferroptosis in RR-HNSCC cell lines. Among the 1,924 genes correlated with radiation treatment, eight showed statistical significance in both the cell lines and The Cancer Genome Atlas (TCGA) cohort. Only five genes—ABCC3, DUSP16, PDGFB, RAF1, and THBS1—showed consistent results between the NTPAM data sequencing and TCGA data. LASSO regression analysis revealed that five genes were associated with cancer prognosis, with a hazard ratio of 2.26. In RR-HNSCC cells, NTPAM affected DUSP16, PDGFB, and THBS1 as activated markers within 6 hours, and this effect persisted for 12 hours. Furthermore, enrichment analysis indicated that these three DEGs were associated with the extracellular matrix, transforming growth factor-beta, phosphoinositide 3-kinase/protein kinase B, and mesenchymal-epithelial transition factor pathways.
Conclusion
. NTPAM therapy exerts cytotoxic effects in RR-HNSCC cell lines by inducing specific ROS-mediated ferroptosis. DUSP16, PDGFB, and THBS1 were identified as crucial targets for reversing the radiation resistance induced by NTPAM therapy, providing insights into the mechanisms and clinical applications of NTPAM treatment in RR-HNSCC.
2.Gene Expression Alteration by Non-thermal Plasma-Activated Media Treatment in Radioresistant Head and Neck Squamous Cell Carcinoma
Sicong ZHENG ; Yudan PIAO ; Seung-Nam JUNG ; Chan OH ; Mi Ae LIM ; QuocKhanh NGUYEN ; Shan SHEN ; Se-Hee PARK ; Shengzhe CUI ; Shuyu PIAO ; Young Il KIM ; Ji Won KIM ; Ho-Ryun WON ; Jae Won CHANG ; Yujuan SHAN ; Lihua LIU ; Bon Seok KOO
Clinical and Experimental Otorhinolaryngology 2025;18(1):73-87
Objectives:
. Head and neck squamous cell carcinoma (HNSCC) exhibits high recurrence rates, particularly in cases of radioresistant HNSCC (RR-HNSCC). Non-thermal plasma (NTP) therapy effectively suppresses the progression of HNSCC. However, the therapeutic mechanisms of NTP therapy in treating RR-HNSCC are not well understood. In this study, we explored the regulatory role of NTP in the RR-HNSCC signaling pathway and identified its signature genes.
Methods:
. After constructing two RR-HNSCC cell lines, we prepared cell lysates from cells treated or not treated with NTP-activated media (NTPAM) and performed RNA sequencing to determine their mRNA expression profiles. Based on the RNA sequencing results, we identified differentially expressed genes (DEGs), followed by a bioinformatics analysis to identify candidate molecules potentially associated with NTPAM therapy for RR-HNSCC.
Results:
. NTPAM reduced RR-HNSCC cell viability in vitro. RNA sequencing results indicated that NTPAM treatment activated the reactive oxygen species (ROS) pathway and induced ferroptosis in RR-HNSCC cell lines. Among the 1,924 genes correlated with radiation treatment, eight showed statistical significance in both the cell lines and The Cancer Genome Atlas (TCGA) cohort. Only five genes—ABCC3, DUSP16, PDGFB, RAF1, and THBS1—showed consistent results between the NTPAM data sequencing and TCGA data. LASSO regression analysis revealed that five genes were associated with cancer prognosis, with a hazard ratio of 2.26. In RR-HNSCC cells, NTPAM affected DUSP16, PDGFB, and THBS1 as activated markers within 6 hours, and this effect persisted for 12 hours. Furthermore, enrichment analysis indicated that these three DEGs were associated with the extracellular matrix, transforming growth factor-beta, phosphoinositide 3-kinase/protein kinase B, and mesenchymal-epithelial transition factor pathways.
Conclusion
. NTPAM therapy exerts cytotoxic effects in RR-HNSCC cell lines by inducing specific ROS-mediated ferroptosis. DUSP16, PDGFB, and THBS1 were identified as crucial targets for reversing the radiation resistance induced by NTPAM therapy, providing insights into the mechanisms and clinical applications of NTPAM treatment in RR-HNSCC.
3.Gene Expression Alteration by Non-thermal Plasma-Activated Media Treatment in Radioresistant Head and Neck Squamous Cell Carcinoma
Sicong ZHENG ; Yudan PIAO ; Seung-Nam JUNG ; Chan OH ; Mi Ae LIM ; QuocKhanh NGUYEN ; Shan SHEN ; Se-Hee PARK ; Shengzhe CUI ; Shuyu PIAO ; Young Il KIM ; Ji Won KIM ; Ho-Ryun WON ; Jae Won CHANG ; Yujuan SHAN ; Lihua LIU ; Bon Seok KOO
Clinical and Experimental Otorhinolaryngology 2025;18(1):73-87
Objectives:
. Head and neck squamous cell carcinoma (HNSCC) exhibits high recurrence rates, particularly in cases of radioresistant HNSCC (RR-HNSCC). Non-thermal plasma (NTP) therapy effectively suppresses the progression of HNSCC. However, the therapeutic mechanisms of NTP therapy in treating RR-HNSCC are not well understood. In this study, we explored the regulatory role of NTP in the RR-HNSCC signaling pathway and identified its signature genes.
Methods:
. After constructing two RR-HNSCC cell lines, we prepared cell lysates from cells treated or not treated with NTP-activated media (NTPAM) and performed RNA sequencing to determine their mRNA expression profiles. Based on the RNA sequencing results, we identified differentially expressed genes (DEGs), followed by a bioinformatics analysis to identify candidate molecules potentially associated with NTPAM therapy for RR-HNSCC.
Results:
. NTPAM reduced RR-HNSCC cell viability in vitro. RNA sequencing results indicated that NTPAM treatment activated the reactive oxygen species (ROS) pathway and induced ferroptosis in RR-HNSCC cell lines. Among the 1,924 genes correlated with radiation treatment, eight showed statistical significance in both the cell lines and The Cancer Genome Atlas (TCGA) cohort. Only five genes—ABCC3, DUSP16, PDGFB, RAF1, and THBS1—showed consistent results between the NTPAM data sequencing and TCGA data. LASSO regression analysis revealed that five genes were associated with cancer prognosis, with a hazard ratio of 2.26. In RR-HNSCC cells, NTPAM affected DUSP16, PDGFB, and THBS1 as activated markers within 6 hours, and this effect persisted for 12 hours. Furthermore, enrichment analysis indicated that these three DEGs were associated with the extracellular matrix, transforming growth factor-beta, phosphoinositide 3-kinase/protein kinase B, and mesenchymal-epithelial transition factor pathways.
Conclusion
. NTPAM therapy exerts cytotoxic effects in RR-HNSCC cell lines by inducing specific ROS-mediated ferroptosis. DUSP16, PDGFB, and THBS1 were identified as crucial targets for reversing the radiation resistance induced by NTPAM therapy, providing insights into the mechanisms and clinical applications of NTPAM treatment in RR-HNSCC.
4.On-site calibration of measurement equipment in state-controlled atmosphere radiation environment automatic monitoring stations
Shaoting LI ; Lixiang XIAO ; Shuyu JIANG ; Chuanbo DAI ; Wenxiang ZHENG
Chinese Journal of Radiological Health 2025;34(3):402-407
Objective To perform on-site calibration of high-pressure ionization chambers and NaI(Tl) γ spectrometers in state-controlled atmospheric radiation environment automatic continuous monitoring stations and verify the reliability of the online radiation environment monitoring system. Methods 137Cs, 60Co, and 241Am were used as γ reference radiation sources to measure the metrological performance of high-pressure ionization chambers in nine state-controlled atmospheric radiation environment automatic monitoring stations in Hubei Province, China. The performance metrics included background radiation, response, and repeatability. Additionally, the correlation between dose rate and humidity was analyzed, and the energy resolution and activity response of NaI(Tl) γ spectrometers were measured. Results Among the nine state-controlled atmospheric radiation environment automatic monitoring stations, the background radiation of high-pressure ionization chambers ranged from 58.2 nGy/h to 82.6 nGy/h. The response of the high-pressure ionization chambers ranged from 0.94 to 1.08, fulfilling the requirement of 1.0 ± 0.2. The repeatability of high-pressure ionization chambers ranged from 0.43% to 3.80%, satisfying the requirement of not exceeding 10%. A significant correlation was observed between dose rate and humidity, with a correlation coefficient of 0.4476. For NaI(Tl) γ spectrometers, the energy resolution ranged from 6.8% to 7.9%, fulfilling the requirement of not exceeding 9% for the 661.7 keV energy peak of 137Cs. The NaI(Tl) γ spectrometers showed 1.4% to 1.8% s−1·Bq−1 activity response to 241Am and 6.6‰ to 8.4‰ s−1·Bq−1 activity response to 60Co. Conclusion The online monitoring systems in the nine state-controlled atmospheric radiation environment automatic monitoring stations are stable and reliable, providing accurate radiation environment monitoring data for public awareness.
5.Performance comparison of domestic and imported CD3/CD28 activation beads for CAR-T cell manufacturing
Xianzheng WEI ; Shuyu ZHANG ; Yuhang JIN ; Pu WANG ; Xu WANG ; Junnian ZHENG ; Dan LIU ; Ming SHI
Chinese Journal of Cancer Biotherapy 2025;32(5):492-497
Objective:To compare the performance differences of domestic and imported CD3/CD28 activation beads for manufacturing CAR-T cells,providing a backup or alternative for domestic CAR-T cell research and manufacture.Methods:A mature protocol using imported CD3/CD28 activation beads with a 1∶1 ratio for CD3+T cells was implemented as research control.Domestic beads were used with gradient ratios of 1∶2,1∶1,and 2∶1 to activate T cells.72 h after T cell activation,CAR-T cells were manufactured by CAR lentiviral infection and cell proliferation was monitored at 2-,4-,and 7-days post-infection.Flow Cytometry was used to detect CAR-T cell positivity 5 days after infection and to detectCD4/CD8 phenotype of CAR-T cells and PD1+TIM3+cell exhaustion ratio 8 days after infection.Results:CAR-T cells manufactured by domestic CD3/CD28 activation beads exhibited similar phenotype compared with those manufactured by imported CD4/CD8 beads.The positive rate of CAR-T cells prepared with domestic beads was slightly lower than that of imported beads(53.7%vs 57.9%).However,the proliferation of CAR-T cells manufactured by domestic beads was about twice that of cells manufactured by imported beads,and the exhaustion level was only half that of imported beads(4.21%vs 7.91%).Moreover,the use of domestic magnetic beads was lower than that of imported magnetic beads,which was advantageous for cutting the costs of CAR-T cells research and manufacture.Conclusion:Domestic CD3/CD28 activation beads used for CAR-T cells manufacturing demonstrate comparable overall performance to their imported counterparts,showing potential as a backup or alternative for imported beads.
6.Influence of implant depth and scanning rod length on accuracy of digital impression for mandibular posterior single-tooth implant restoration
Shuyu SUN ; Xinyan ZHENG ; Hongqin GAN ; Ruixue TIAN ; Xiaofei XIE
Journal of Southern Medical University 2024;44(11):2250-2255
Objective To study the influence of implant depth and scanning rod lengths on the accuracy of digital impression for single-tooth implant restoration of the mandibular posterior teeth.Methods Five standard dental cast models with missing right mandibular first molar(46)were prepared with the subgingival implant depths of 0,1,3,5 and 7 mm.ITI RC and ITI RC H11 scanning rods were connected to the replacement body and placed into the seating tract for scanning.The reference data were obtained using a 3D dental scanner,and the experimental data were obtained by 10 scans of each model using a digitized intraoral scanner.Geomagic Wrap 2021 was used to analyze the model data to test the trueness and precision of the models.Results The trueness did not differ significantly among the groups(P>0.05).The implant depth of 1 mm achieved the highest impression precision(66.81±2.45 μm),and the depth of 0 mm resulted in a significantly lower precision(95.60±3.04 μm)than the depth of 1 and 3 mm.Starting from the subgingival depth of 1 mm,the precision of the scan decreased progressively with the increase of the implant depth.At the subgingival implant depth of 5 or 7 mm,the use of an extended rod significantly improved the scan precision.Conclusion For single-tooth implant restoration of the mandibular posterior teeth,the implant depth can substantially affect the accuracy of digital impression,which decreases as the implant depth increases.For a deep implant,the use of a longer scanning rod can improve the scanning accuracy.
7.Influence of implant depth and scanning rod length on accuracy of digital impression for mandibular posterior single-tooth implant restoration
Shuyu SUN ; Xinyan ZHENG ; Hongqin GAN ; Ruixue TIAN ; Xiaofei XIE
Journal of Southern Medical University 2024;44(11):2250-2255
Objective To study the influence of implant depth and scanning rod lengths on the accuracy of digital impression for single-tooth implant restoration of the mandibular posterior teeth.Methods Five standard dental cast models with missing right mandibular first molar(46)were prepared with the subgingival implant depths of 0,1,3,5 and 7 mm.ITI RC and ITI RC H11 scanning rods were connected to the replacement body and placed into the seating tract for scanning.The reference data were obtained using a 3D dental scanner,and the experimental data were obtained by 10 scans of each model using a digitized intraoral scanner.Geomagic Wrap 2021 was used to analyze the model data to test the trueness and precision of the models.Results The trueness did not differ significantly among the groups(P>0.05).The implant depth of 1 mm achieved the highest impression precision(66.81±2.45 μm),and the depth of 0 mm resulted in a significantly lower precision(95.60±3.04 μm)than the depth of 1 and 3 mm.Starting from the subgingival depth of 1 mm,the precision of the scan decreased progressively with the increase of the implant depth.At the subgingival implant depth of 5 or 7 mm,the use of an extended rod significantly improved the scan precision.Conclusion For single-tooth implant restoration of the mandibular posterior teeth,the implant depth can substantially affect the accuracy of digital impression,which decreases as the implant depth increases.For a deep implant,the use of a longer scanning rod can improve the scanning accuracy.
8.Platycodin D inhibits angiogenic vascular mimicry in NSCLC by regulating the eIF4E-mediated RNA methylome.
Shuyu ZHENG ; Yanlin XIN ; Jiamin LIN ; Zejuan XIE ; Keyu CHENG ; Shanshan WANG ; Wenli LU ; Hao YANG ; Tianming LU ; Jun LI ; Ruogu QI ; Yuanyuan GUO
Journal of Pharmaceutical Analysis 2024;14(1):152-155
Image 1.
9.Application Status and Prospect of Artificial Intelligence Large Models in Medicine
Yanli ZHENG ; Fuhai HAN ; Shuyu LI ; Wenxing SU
Journal of Medical Informatics 2024;45(6):24-29
Purpose/Significance To sort out and analyze the application status of artificial intelligence(AI)large models in medi-cine,so as to provide new perspectives for research in this domain.Method/Process Based on a review of relevant literatures,the paper outlines the application scenarios and examples of AI large models in the fields of smart medical care,medical metaverse,medical re-search and development,etc.It also summarizes the risks and challenges in the application of AI large models in medicine.Result/Con-clusion AI large models have great development potential in medicine,and it is necessary to promote the core technologies of AI large models and improve relevant regulations and laws.
10.Clinical implications of the concentration of alveolar nitric oxide in non-small cell lung cancer.
Xiaodan CHANG ; Hua LIAO ; Lingyan XIE ; Yuehua CHEN ; Liying ZHENG ; Jianpeng LIANG ; Weiwei YU ; Yuexian WU ; Yanmei YE ; Shuyu HUANG ; Haijin ZHAO ; Shaoxi CAI ; Hangming DONG
Chinese Medical Journal 2023;136(18):2246-2248

Result Analysis
Print
Save
E-mail