1.Establishment and Preliminary Analysis of an AG6 Mouse Encephalopathy Model Induced by Vaccinia Virus Tiantan Strain Infection
Lin YANG ; Meng JIN ; Hanqing WU ; Shun LI ; Xiaohui ZHOU
Laboratory Animal and Comparative Medicine 2026;46(1):3-10
ObjectiveA mouse model of vaccinia virus Tiantan strain (VTT)-induced encephalopathy was developed using AG6 mice. MethodsVTT was amplified by infecting Vero cells at a multiplicity of infection (MOI) of 0.01, followed by concentration and titration. After 72 h of incubation, virus-containing cells were collected and subjected to concentration. The concentrated viral suspension was serially diluted (10-fold dilutions) and added to 6-well plates containing confluent Vero cell monolayers for plaque assay. The number of plaques formed in each well was counted, and the virus titer was calculated based on the dilution factor. Fourteen 5-6-week-old AG6 mice (half male and half female, housed separately by sex) were randomly divided into a control group (n=3, PBS), a low-dose group (n=6, 1×10⁵ PFU), and a high-dose group (n=5, 5×10⁵ PFU). The mice were anesthetized by isoflurane inhalation and then infected via intranasal instillation. The mental state of the mice in each group was observed daily, and the body weight and mortality were recorded. On day 13 post-infection, 2% Evans Blue (4 mL/kg body weight) was administered via tail vein injection to assess blood-brain barrier (BBB) disruption. Subsequently, brain tissue samples were collected for immunofluorescence analysis to evaluate the activation of astrocytes and microglia. ResultsThe titer of purified VTT was 1×10⁷ PFU/mL. Compared with the control group, mice in the low-dose group showed no significant change in body weight, and no lethality was observed. In contrast, mice in the high-dose group exhibited significant weight loss starting on day 5 post-infection (P<0.05), accompanied by lethality. On day 13 post-infection, no Evans Blue extravasation was detected in the brain tissues of the low-dose group, while the olfactory bulb region of the high-dose group displayed distinct blue staining, indicating disruption of the BBB. Immunofluorescence analysis revealed no significant proliferation of astrocytes and microglia in the olfactory bulb region of the low-dose group on day 13 post-infection. In contrast, marked activation of glial cells was observable in the high-dose group. ConclusionAn animal model of VTT-induced encephalopathy in AG6 mice is successfully established, characterized by BBB disruption and reactive gliosis specifically localized to the olfactory bulb region, manifested as astrocytic and microglial proliferation.
2.Rapid quality control method for automated organ-at-risk contouring in head and neck radiotherapy
Xiaoyu YANG ; Kaining YAO ; Yichen PU ; Shun ZHOU ; Ruoxi WANG ; Haizhen YUE ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):193-199
Objective To address the need for rapid review of automated organ-at-risk (OAR) contouring for head-and-neck cancer in online adaptive radiotherapy, this study used dosimetric indices as the reference standard to evaluate the suitability of geometric similarity metrics and to develop a rapid screening model that balances the risk of missed errors with review efficiency. Methods This retrospective study included 29 patients with head-and-neck radiotherapy, yielding 243 pairs of OAR contours (auto-generated vs. manual). Geometric similarity metrics, including the Dice similarity coefficient (Dice), the 95th percentile Hausdorff distance (HD95), and the maximum Hausdorff distance (HD100), were computed between the two contour sets. Using the dose distributions from clinical treatment plans, dosimetric differences between the two contour sets were calculated for key indices, including mean dose (Dmean) and maximum dose (Dmax). Correlations between geometric metrics and dosimetric differences were analyzed. Dosimetric discrepancy events were defined as Y3Gy using a threshold of 3 Gy. Within a univariable logistic regression triage framework, each geometric metric was used as an independent variable to estimate the probability of Y3Gy. Discriminative performance was assessed using receiver operating characteristic (ROC) curves and precision-recall (PR) curves, with the area under the curve (AUC) including ROC-AUC and PR-AUC. Practical operating thresholds were determined via threshold sweeping. Results Geometric similarity metrics showed weak-to-moderate correlations with dosimetric differences; compared with maximum dose, correlations with mean dose differences were more consistent. Among the evaluated metrics, HD95 achieved the best classification performance for Y3Gy. Threshold sweeping suggested that an HD95 threshold in the range of 4-9 mm can balance the risk of missed discrepancies with the efficiency of automated contour quality assurance (QA). Conclusion Several geometric similarity metrics demonstrated only weak-to-moderate associations with dosimetric differences. For head-and-neck OAR contour QA in this study, HD95 provided the best discriminative performance and can support rapid triage of automated contours, with a practical operating threshold range of 4-9 mm, potentially improving the efficiency of adaptive radiotherapy workflows.
3.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
4.Rapid quality control method for automated organ-at-risk contouring in head and neck radiotherapy
Xiaoyu YANG ; Kaining YAO ; Yichen PU ; Shun ZHOU ; Ruoxi WANG ; Haizhen YUE ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):193-199
Objective To address the need for rapid review of automated organ-at-risk (OAR) contouring for head-and-neck cancer in online adaptive radiotherapy, this study used dosimetric indices as the reference standard to evaluate the suitability of geometric similarity metrics and to develop a rapid screening model that balances the risk of missed errors with review efficiency. Methods This retrospective study included 29 patients with head-and-neck radiotherapy, yielding 243 pairs of OAR contours (auto-generated vs. manual). Geometric similarity metrics, including the Dice similarity coefficient (Dice), the 95th percentile Hausdorff distance (HD95), and the maximum Hausdorff distance (HD100), were computed between the two contour sets. Using the dose distributions from clinical treatment plans, dosimetric differences between the two contour sets were calculated for key indices, including mean dose (Dmean) and maximum dose (Dmax). Correlations between geometric metrics and dosimetric differences were analyzed. Dosimetric discrepancy events were defined as Y3Gy using a threshold of 3 Gy. Within a univariable logistic regression triage framework, each geometric metric was used as an independent variable to estimate the probability of Y3Gy. Discriminative performance was assessed using receiver operating characteristic (ROC) curves and precision-recall (PR) curves, with the area under the curve (AUC) including ROC-AUC and PR-AUC. Practical operating thresholds were determined via threshold sweeping. Results Geometric similarity metrics showed weak-to-moderate correlations with dosimetric differences; compared with maximum dose, correlations with mean dose differences were more consistent. Among the evaluated metrics, HD95 achieved the best classification performance for Y3Gy. Threshold sweeping suggested that an HD95 threshold in the range of 4-9 mm can balance the risk of missed discrepancies with the efficiency of automated contour quality assurance (QA). Conclusion Several geometric similarity metrics demonstrated only weak-to-moderate associations with dosimetric differences. For head-and-neck OAR contour QA in this study, HD95 provided the best discriminative performance and can support rapid triage of automated contours, with a practical operating threshold range of 4-9 mm, potentially improving the efficiency of adaptive radiotherapy workflows.
5.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
6.Rapid quality control method for automated organ-at-risk contouring in head and neck radiotherapy
Xiaoyu YANG ; Kaining YAO ; Yichen PU ; Shun ZHOU ; Ruoxi WANG ; Haizhen YUE ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):193-199
Objective To address the need for rapid review of automated organ-at-risk (OAR) contouring for head-and-neck cancer in online adaptive radiotherapy, this study used dosimetric indices as the reference standard to evaluate the suitability of geometric similarity metrics and to develop a rapid screening model that balances the risk of missed errors with review efficiency. Methods This retrospective study included 29 patients with head-and-neck radiotherapy, yielding 243 pairs of OAR contours (auto-generated vs. manual). Geometric similarity metrics, including the Dice similarity coefficient (Dice), the 95th percentile Hausdorff distance (HD95), and the maximum Hausdorff distance (HD100), were computed between the two contour sets. Using the dose distributions from clinical treatment plans, dosimetric differences between the two contour sets were calculated for key indices, including mean dose (Dmean) and maximum dose (Dmax). Correlations between geometric metrics and dosimetric differences were analyzed. Dosimetric discrepancy events were defined as Y3Gy using a threshold of 3 Gy. Within a univariable logistic regression triage framework, each geometric metric was used as an independent variable to estimate the probability of Y3Gy. Discriminative performance was assessed using receiver operating characteristic (ROC) curves and precision-recall (PR) curves, with the area under the curve (AUC) including ROC-AUC and PR-AUC. Practical operating thresholds were determined via threshold sweeping. Results Geometric similarity metrics showed weak-to-moderate correlations with dosimetric differences; compared with maximum dose, correlations with mean dose differences were more consistent. Among the evaluated metrics, HD95 achieved the best classification performance for Y3Gy. Threshold sweeping suggested that an HD95 threshold in the range of 4-9 mm can balance the risk of missed discrepancies with the efficiency of automated contour quality assurance (QA). Conclusion Several geometric similarity metrics demonstrated only weak-to-moderate associations with dosimetric differences. For head-and-neck OAR contour QA in this study, HD95 provided the best discriminative performance and can support rapid triage of automated contours, with a practical operating threshold range of 4-9 mm, potentially improving the efficiency of adaptive radiotherapy workflows.
7.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
8.Guidelines for the perioperative diagnosis and treatment of oncogene-driven non-small cell lung cancer (2026)
Weidong WANG ; Yongbin LIN ; Hui TIAN ; Gaofeng LI ; Shun XU ; Yongde LIAO ; Haitao MA ; Junfeng LIU ; Chundong GU ; Xiaolong YAN ; Shumin WANG ; Daqiang SUN ; Jianyang LIU ; Tao XUE ; Shaohua MA ; Zhigang LI ; Shuanghu YUAN ; Gen LIN ; Ling CAI ; Jianping ZHOU ; Wenzhao ZHONG ; Naixin LIANG ; Yi HAN ; Junfeng WANG ; Weidong ZHANG ; Xin WANG ; Lianjuan CHEN ; Lunxu LIU ; Xiuyi ZHI ; Lanjun ZHANG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(09):1337-1353
Lung cancer constitutes the most prevalent and lethal malignant tumor in China. Approximately 85% of lung cancer diagnoses correspond to the non-small cell histological subtype [non-small cell lung cancer (NSCLC)]. Despite surgery being the mainstay for early-stage disease, postoperative recurrence remains high and adjuvant chemotherapy offers limited benefit. In recent years, targeted therapy has demonstrated substantial advantages in driver mutation-positive NSCLC. To this end, the Lung Cancer Medical Education Committee of the Chinese Medical Education Association developed guidelines based on a systematic review of evidence through November 2025, using the Grading of Recommendations, Assessment, Development and Evaluations (GRADE) approach and a modified Delphi method. Focusing on epidermal growth factor receptor (EGFR) and anaplastic lymphoma kinase (ALK), and addressing ROS proto-oncogene 1 (ROS1), B-Raf proto-oncogene serine/threonine kinase (BRAF) V600E mutation, and mesenchymal-epithelial transition factor (MET) exon 14 (METex14) skipping, the guideline covers molecular testing, neoadjuvant/adjuvant therapy, perioperative strategies, minimal residual disease monitoring, and postoperative surveillance. It defines testing requirements, specifies stage-directed and subtype-specific treatments, and standardizes minimal residual disease monitoring. These recommendations emphasize precision and feasibility to improve survival and quality of life.
9.Optimal harvesting period of cultivated Notopterygium incisum based on HPLC specific chromatogram combined with chemometrics and entropy weight-gray correlation analysis.
Jing-Cheng WANG ; Hong-Bing SUN ; Teng LIU ; Wen-Tao ZHU ; Hong-Lan WANG ; Yi ZHOU ; Wei-Yan WANG ; Ping YANG ; Shun-Yuan JIANG
China Journal of Chinese Materia Medica 2025;50(14):3878-3886
To determine the optimal cultivation duration and harvest period for cultivated Notopterygium incisum and promote its industrial development, this study established a characteristic chromatographic profile of cultivated N. incisum and employed chemometrics combined with entropy-weighted grey correlation analysis to assess differences in agronomic traits and quality indicators across different cultivation years and harvest periods. By comparing with reference substances, ten common peaks were identified, including chlorogenic acid, p-coumaric acid, ferulic acid, marmesinin, nodakenin, isochlorogenic acid B, notopterol, phenethyl ferulate, isoimperatorin, and falcarindiol. The similarity between the characteristic chromatographic profiles of N. incisum at different cultivation years and the reference profile was all above 0.932. Principal component analysis(PCA) and orthogonal partial least squares discriminant analysis(OPLS-DA) revealed that the quality of 1-to 3-year-old cultivated N. incisum was highly dispersed and unstable, whereas the quality of 4-year-old cultivated N. incisum remained relatively stable across different harvest periods. This suggests that the accumulation of relevant compounds in the medicinal material had reached a plateau, confirming that the optimal cultivation period for N. incisum is four years. Entropy-weighted grey correlation analysis indicated that the quality of 4-year-old cultivated N. incisum across different harvest periods ranked from highest to lowest as follows: November, December, October, August, July, and September, demonstrating that November is the optimal harvest time. The findings of this study establish the suitable cultivation duration and optimal harvest period for N. incisum, providing a scientific basis for cultivation guidance and quality standardization.
Chromatography, High Pressure Liquid/methods*
;
Apiaceae/chemistry*
;
Entropy
;
Chemometrics/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Principal Component Analysis
;
Quality Control
10.Effect of Xiongcan Yishen Formula on ferroptosis in testicular tissue of male rats with late-onset hypogonadism
Ajian PENG ; Haoyu WANG ; Chun YANG ; Wei LIU ; Gang NING ; Hui WU ; Xing ZHOU ; Shun ZENG
National Journal of Andrology 2025;31(11):1014-1020
Objective To explore the effect of Xiongcan Yishen Formula on ferroptosis in testicular tissue of male rats with late-onset hypogonadism(LOH).Methods A total of 48 male Sprague-Dawley rats aged 6 months were randomly divided into model group,low-dose and high-dose Xiongcan Yishen Formula groups and propionate testosterone group,with 12 rats in each group.An additional 6 male Sprague-Dawley rats aged 8 weeks were set as the normal group.Except for the normal group,the rats were intraperitoneally injected with Cyclophosphamide at a dose of 20 mg/(kg·d)for 5 consecutive days to establish the LOH model,while the normal group received an equal volume of physiological saline for 5 days.The normal group and model group were given equal volumes of distilled water by gavage,while the low-dose and high-dose Xiongcan Yishen Formula groups were administered concentrated decoction at doses of 10.4 g and 41.6 g/kg/d respectively,and the propionate testosterone group received intramuscular injections of 5.21 mg/kg/d propionate testosterone,all for 28 consecutive days.ELISA was used to detect serum testosterone levels in rats,HE staining and transmission electron microscopy were used to observe the gross morphology of testicular tissue and the ultrastructure of Leydig cells,and RT-qPCR and Western blotting were used to detect the expression of ferroptosis-related genes and proteins in testicular tissue.Results The LOH model rats exhibited pathological changes such as atrophy of seminiferous tubules,structural disorder,and reduced spermatocytes in the lumen,as well as ultrastructural changes in Leydig cells including altered nuclear morphology,increased mitochondrial density,and reduced cristae.After intervention with Xiongcan Yishen Formula and propionate testosterone,the pathological changes in testis and the ultrastructure of Leydig cells were improved.Compared with the normal group,serum testosterone levels in the model group were significantly decreased(P<0.05),the expression of ROS,ACSL4 mRNA and protein in testicular tissue was significantly increased,while the expression of FTH1,GPX4,and SLC7A11 mRNA and protein was significantly decreased(P<0.05).Compared with the model group,ser-um testosterone levels in the low-dose and high-dose Xiongcan Yishen Formula groups and the propionate testosterone group were significantly increased(P<0.05),and the expression of ROS,ACSL4 mRNA and protein was significantly decreased(P<0.05);the high-dose Xiongcan Yishen Formula group showed significantly increased expression of FTH1,GPX4,and SLC7A11 mRNA and protein(P<0.05).Conclusion Ferroptosis in testicular tissue is increased in LOH rats,and Xiongcan Yishen For-mula can elevate serum testosterone levels and improve pathological changes and ultrastructure in testicular tissue of LOH rats,possibly related to the inhibition of ferroptosis in testicular tissue of LOH rats.

Result Analysis
Print
Save
E-mail