1.Establishment and Preliminary Analysis of an AG6 Mouse Encephalopathy Model Induced by Vaccinia Virus Tiantan Strain Infection
Lin YANG ; Meng JIN ; Hanqing WU ; Shun LI ; Xiaohui ZHOU
Laboratory Animal and Comparative Medicine 2026;46(1):3-10
ObjectiveA mouse model of vaccinia virus Tiantan strain (VTT)-induced encephalopathy was developed using AG6 mice. MethodsVTT was amplified by infecting Vero cells at a multiplicity of infection (MOI) of 0.01, followed by concentration and titration. After 72 h of incubation, virus-containing cells were collected and subjected to concentration. The concentrated viral suspension was serially diluted (10-fold dilutions) and added to 6-well plates containing confluent Vero cell monolayers for plaque assay. The number of plaques formed in each well was counted, and the virus titer was calculated based on the dilution factor. Fourteen 5-6-week-old AG6 mice (half male and half female, housed separately by sex) were randomly divided into a control group (n=3, PBS), a low-dose group (n=6, 1×10⁵ PFU), and a high-dose group (n=5, 5×10⁵ PFU). The mice were anesthetized by isoflurane inhalation and then infected via intranasal instillation. The mental state of the mice in each group was observed daily, and the body weight and mortality were recorded. On day 13 post-infection, 2% Evans Blue (4 mL/kg body weight) was administered via tail vein injection to assess blood-brain barrier (BBB) disruption. Subsequently, brain tissue samples were collected for immunofluorescence analysis to evaluate the activation of astrocytes and microglia. ResultsThe titer of purified VTT was 1×10⁷ PFU/mL. Compared with the control group, mice in the low-dose group showed no significant change in body weight, and no lethality was observed. In contrast, mice in the high-dose group exhibited significant weight loss starting on day 5 post-infection (P<0.05), accompanied by lethality. On day 13 post-infection, no Evans Blue extravasation was detected in the brain tissues of the low-dose group, while the olfactory bulb region of the high-dose group displayed distinct blue staining, indicating disruption of the BBB. Immunofluorescence analysis revealed no significant proliferation of astrocytes and microglia in the olfactory bulb region of the low-dose group on day 13 post-infection. In contrast, marked activation of glial cells was observable in the high-dose group. ConclusionAn animal model of VTT-induced encephalopathy in AG6 mice is successfully established, characterized by BBB disruption and reactive gliosis specifically localized to the olfactory bulb region, manifested as astrocytic and microglial proliferation.
2.Rapid quality control method for automated organ-at-risk contouring in head and neck radiotherapy
Xiaoyu YANG ; Kaining YAO ; Yichen PU ; Shun ZHOU ; Ruoxi WANG ; Haizhen YUE ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):193-199
Objective To address the need for rapid review of automated organ-at-risk (OAR) contouring for head-and-neck cancer in online adaptive radiotherapy, this study used dosimetric indices as the reference standard to evaluate the suitability of geometric similarity metrics and to develop a rapid screening model that balances the risk of missed errors with review efficiency. Methods This retrospective study included 29 patients with head-and-neck radiotherapy, yielding 243 pairs of OAR contours (auto-generated vs. manual). Geometric similarity metrics, including the Dice similarity coefficient (Dice), the 95th percentile Hausdorff distance (HD95), and the maximum Hausdorff distance (HD100), were computed between the two contour sets. Using the dose distributions from clinical treatment plans, dosimetric differences between the two contour sets were calculated for key indices, including mean dose (Dmean) and maximum dose (Dmax). Correlations between geometric metrics and dosimetric differences were analyzed. Dosimetric discrepancy events were defined as Y3Gy using a threshold of 3 Gy. Within a univariable logistic regression triage framework, each geometric metric was used as an independent variable to estimate the probability of Y3Gy. Discriminative performance was assessed using receiver operating characteristic (ROC) curves and precision-recall (PR) curves, with the area under the curve (AUC) including ROC-AUC and PR-AUC. Practical operating thresholds were determined via threshold sweeping. Results Geometric similarity metrics showed weak-to-moderate correlations with dosimetric differences; compared with maximum dose, correlations with mean dose differences were more consistent. Among the evaluated metrics, HD95 achieved the best classification performance for Y3Gy. Threshold sweeping suggested that an HD95 threshold in the range of 4-9 mm can balance the risk of missed discrepancies with the efficiency of automated contour quality assurance (QA). Conclusion Several geometric similarity metrics demonstrated only weak-to-moderate associations with dosimetric differences. For head-and-neck OAR contour QA in this study, HD95 provided the best discriminative performance and can support rapid triage of automated contours, with a practical operating threshold range of 4-9 mm, potentially improving the efficiency of adaptive radiotherapy workflows.
3.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
4.Rapid quality control method for automated organ-at-risk contouring in head and neck radiotherapy
Xiaoyu YANG ; Kaining YAO ; Yichen PU ; Shun ZHOU ; Ruoxi WANG ; Haizhen YUE ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):193-199
Objective To address the need for rapid review of automated organ-at-risk (OAR) contouring for head-and-neck cancer in online adaptive radiotherapy, this study used dosimetric indices as the reference standard to evaluate the suitability of geometric similarity metrics and to develop a rapid screening model that balances the risk of missed errors with review efficiency. Methods This retrospective study included 29 patients with head-and-neck radiotherapy, yielding 243 pairs of OAR contours (auto-generated vs. manual). Geometric similarity metrics, including the Dice similarity coefficient (Dice), the 95th percentile Hausdorff distance (HD95), and the maximum Hausdorff distance (HD100), were computed between the two contour sets. Using the dose distributions from clinical treatment plans, dosimetric differences between the two contour sets were calculated for key indices, including mean dose (Dmean) and maximum dose (Dmax). Correlations between geometric metrics and dosimetric differences were analyzed. Dosimetric discrepancy events were defined as Y3Gy using a threshold of 3 Gy. Within a univariable logistic regression triage framework, each geometric metric was used as an independent variable to estimate the probability of Y3Gy. Discriminative performance was assessed using receiver operating characteristic (ROC) curves and precision-recall (PR) curves, with the area under the curve (AUC) including ROC-AUC and PR-AUC. Practical operating thresholds were determined via threshold sweeping. Results Geometric similarity metrics showed weak-to-moderate correlations with dosimetric differences; compared with maximum dose, correlations with mean dose differences were more consistent. Among the evaluated metrics, HD95 achieved the best classification performance for Y3Gy. Threshold sweeping suggested that an HD95 threshold in the range of 4-9 mm can balance the risk of missed discrepancies with the efficiency of automated contour quality assurance (QA). Conclusion Several geometric similarity metrics demonstrated only weak-to-moderate associations with dosimetric differences. For head-and-neck OAR contour QA in this study, HD95 provided the best discriminative performance and can support rapid triage of automated contours, with a practical operating threshold range of 4-9 mm, potentially improving the efficiency of adaptive radiotherapy workflows.
5.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
6.Rapid quality control method for automated organ-at-risk contouring in head and neck radiotherapy
Xiaoyu YANG ; Kaining YAO ; Yichen PU ; Shun ZHOU ; Ruoxi WANG ; Haizhen YUE ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):193-199
Objective To address the need for rapid review of automated organ-at-risk (OAR) contouring for head-and-neck cancer in online adaptive radiotherapy, this study used dosimetric indices as the reference standard to evaluate the suitability of geometric similarity metrics and to develop a rapid screening model that balances the risk of missed errors with review efficiency. Methods This retrospective study included 29 patients with head-and-neck radiotherapy, yielding 243 pairs of OAR contours (auto-generated vs. manual). Geometric similarity metrics, including the Dice similarity coefficient (Dice), the 95th percentile Hausdorff distance (HD95), and the maximum Hausdorff distance (HD100), were computed between the two contour sets. Using the dose distributions from clinical treatment plans, dosimetric differences between the two contour sets were calculated for key indices, including mean dose (Dmean) and maximum dose (Dmax). Correlations between geometric metrics and dosimetric differences were analyzed. Dosimetric discrepancy events were defined as Y3Gy using a threshold of 3 Gy. Within a univariable logistic regression triage framework, each geometric metric was used as an independent variable to estimate the probability of Y3Gy. Discriminative performance was assessed using receiver operating characteristic (ROC) curves and precision-recall (PR) curves, with the area under the curve (AUC) including ROC-AUC and PR-AUC. Practical operating thresholds were determined via threshold sweeping. Results Geometric similarity metrics showed weak-to-moderate correlations with dosimetric differences; compared with maximum dose, correlations with mean dose differences were more consistent. Among the evaluated metrics, HD95 achieved the best classification performance for Y3Gy. Threshold sweeping suggested that an HD95 threshold in the range of 4-9 mm can balance the risk of missed discrepancies with the efficiency of automated contour quality assurance (QA). Conclusion Several geometric similarity metrics demonstrated only weak-to-moderate associations with dosimetric differences. For head-and-neck OAR contour QA in this study, HD95 provided the best discriminative performance and can support rapid triage of automated contours, with a practical operating threshold range of 4-9 mm, potentially improving the efficiency of adaptive radiotherapy workflows.
7.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
8.Optimal harvesting period of cultivated Notopterygium incisum based on HPLC specific chromatogram combined with chemometrics and entropy weight-gray correlation analysis.
Jing-Cheng WANG ; Hong-Bing SUN ; Teng LIU ; Wen-Tao ZHU ; Hong-Lan WANG ; Yi ZHOU ; Wei-Yan WANG ; Ping YANG ; Shun-Yuan JIANG
China Journal of Chinese Materia Medica 2025;50(14):3878-3886
To determine the optimal cultivation duration and harvest period for cultivated Notopterygium incisum and promote its industrial development, this study established a characteristic chromatographic profile of cultivated N. incisum and employed chemometrics combined with entropy-weighted grey correlation analysis to assess differences in agronomic traits and quality indicators across different cultivation years and harvest periods. By comparing with reference substances, ten common peaks were identified, including chlorogenic acid, p-coumaric acid, ferulic acid, marmesinin, nodakenin, isochlorogenic acid B, notopterol, phenethyl ferulate, isoimperatorin, and falcarindiol. The similarity between the characteristic chromatographic profiles of N. incisum at different cultivation years and the reference profile was all above 0.932. Principal component analysis(PCA) and orthogonal partial least squares discriminant analysis(OPLS-DA) revealed that the quality of 1-to 3-year-old cultivated N. incisum was highly dispersed and unstable, whereas the quality of 4-year-old cultivated N. incisum remained relatively stable across different harvest periods. This suggests that the accumulation of relevant compounds in the medicinal material had reached a plateau, confirming that the optimal cultivation period for N. incisum is four years. Entropy-weighted grey correlation analysis indicated that the quality of 4-year-old cultivated N. incisum across different harvest periods ranked from highest to lowest as follows: November, December, October, August, July, and September, demonstrating that November is the optimal harvest time. The findings of this study establish the suitable cultivation duration and optimal harvest period for N. incisum, providing a scientific basis for cultivation guidance and quality standardization.
Chromatography, High Pressure Liquid/methods*
;
Apiaceae/chemistry*
;
Entropy
;
Chemometrics/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Principal Component Analysis
;
Quality Control
9.Research progress on the manufacturing technology of hollow microneedles.
Shengshuo ZHOU ; Huajian ZHOU ; Xiaoyu DU ; Ziye YU ; Tongle XU ; Shun ZHAO ; Peiqiang SU ; Leian ZHANG ; Guangyang FU ; Xuelei LIU
Journal of Biomedical Engineering 2025;42(2):423-430
Drug administration via hollow microneedles (HMN) have the advantages of painlessness, avoidance of first-pass effect, capability of sustained infusion, and no need for professional personnel operation. In addition, HMN can also be applied in the fields of body fluid extraction and biosensors, showing broad application prospects. However, traditional manufacturing technologies cannot meet the demand for low-cost mass production of HMN, limiting its widespread application. This paper reviews the main manufacturing technologies used for HMN in recent years, which include photolithography and etching, laser etching, sputtering and electroplating, micro-molding, three-dimensional (3D) printing and drawing lithography. It further analyzes the characteristics and limitations of existing manufacturing technologies and points out that the combination of various manufacturing technologies can improve production efficiency to a certain extent. In addition, this paper looks forward to the future trends of HMN manufacturing technology and proposes possible directions for its development. In conclusion, it is expected that this review can provide new ideas and references for follow-up research.
Printing, Three-Dimensional
;
Needles
;
Humans
;
Drug Delivery Systems/methods*
;
Equipment Design
;
Microinjections/methods*
10.Mechanism of Congrong Zonggan Capsules in Improving Neuroinflammation and Cognitive Impairment in 5×FAD Mice Based on NF-κB/NLRP3 Signaling Pathway
Yanru ZHOU ; Xinru GU ; Yuru LIU ; Shun ZHANG ; Yaozhong LYU ; Zhenzhong WANG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(10):130-138
ObjectiveTo investigate the effects of Congrong Zonggan capsules (CRZG) on cognitive impairment in the Alzheimer's disease (AD) model of mice and its related mechanisms. MethodsSPF grade 4-week-old 5×FAD mice were divided into a model group, low-dose CRZG (0.819 g·kg-1) and high-dose CRZG (1.638 g·kg-1) groups, and Donepezilepezil hydrochloride group (2 mg·kg-1), with eight mice in each group. Eight C57 mice with the same background were set as the normal group. After one week of adaptive feeding, mice were orally administered continuously for six months. On the 5th month of drug administration, Y maze, new object recognition, and Morris water maze tests were conducted separately. After administration, mouse brain tissue was taken, and the levels of tumor necrosis factor-α (TNF-α) and interleukin-6 (IL-6) in brain tissue were detected by enzyme-linked immunosorbent assay (ELISA). Immunofluorescence (IF) was used to detect the expression of small glial cell markers Iba1, astrocyte markers GFAP, and amyloid protein 1-42 (Aβ1-42) in the hippocampus of the brain tissue. The hematoxylin-eosin (HE) staining was used to detect pathological changes in the hippocampus of brain tissue. Western blot was used to detect the expression of nuclear factor-κB (NF-κB) p65, NOD-like receptor protein 3 (NLRP3), cleaved Caspase-1, apoptosis-associated speck-like protein containing a CARD (ASC), and other proteins in the brain tissue. ResultsCompared with those in the normal group, the mice in the model group had obvious cognitive impairment. The spontaneous alternation rate of the Y maze was decreased, and the discrimination index of novel object recognition was decreased significantly (P<0.01). The escape latency in the water maze was shortened significantly (P<0.01). The contents of IL-6 and TNF-α in brain tissue were increased. The fluorescence levels of Iba1 and Aβ1-42 in the hippocampus were significantly increased (P<0.01). There was a significant increase in neuronal lesions, neuronal atrophy, loose arrangement of tissue structure, and abnormal erythrocyte aggregation in the hippocampus. The protein expressions of p-NF-κB p65/NF-κB p65, cleaved Caspase-1, ASC, IL-6, and IL-1β were significantly increased (P<0.05, P<0.01). Compared with the model group, the spontaneous alternation rate and discrimination index of the high-dose CRZG group were increased significantly (P<0.01), and the escape latency was shortened significantly (P<0.05, P<0.01). The content of IL-6 decreased in the brain, and that of TNF-α dropped significantly (P<0.01). The expression of Iba1 protein and Aβ1-42 in the hippocampus decreased significantly (P<0.05, P<0.01). The hippocampal neurons were densely arranged, and the pyramidal nuclei were clear and centered. The abnormal aggregation of red blood cells was alleviated. The value of p-NF-κB/NF-κB proteins and the expression of ASC, cleaved Caspase-1, IL-6, and IL-1β were significantly decreased (P<0.05, P<0.01). ConclusionCRZG can effectively improve cognitive impairment in 5×FAD mice with Alzheimer's disease, and its mechanism may be related to the regulation of the NF-κB/NLRP3 pathway to reduce the abnormal activation of microglia and inhibit neuroinflammation.

Result Analysis
Print
Save
E-mail