1.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
2.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
3.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
4.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
5.Expert consensus on difficulty assessment of endodontic therapy
Huang DINGMING ; Wang XIAOYAN ; Liang JINGPING ; Ling JUNQI ; Bian ZHUAN ; Yu QING ; Hou BENXIANG ; Chen XINMEI ; Li JIYAO ; Ye LING ; Cheng LEI ; Xu XIN ; Hu TAO ; Wu HONGKUN ; Guo BIN ; Su QIN ; Chen ZHI ; Qiu LIHONG ; Chen WENXIA ; Wei XI ; Huang ZHENGWEI ; Yu JINHUA ; Lin ZHENGMEI ; Zhang QI ; Yang DEQIN ; Zhao JIN ; Pan SHUANG ; Yang JIAN ; Wu JIAYUAN ; Pan YIHUAI ; Xie XIAOLI ; Deng SHULI ; Huang XIAOJING ; Zhang LAN ; Yue LIN ; Zhou XUEDONG
International Journal of Oral Science 2024;16(1):15-25
Endodontic diseases are a kind of chronic infectious oral disease.Common endodontic treatment concepts are based on the removal of inflamed or necrotic pulp tissue and the replacement by gutta-percha.However,it is very essential for endodontic treatment to debride the root canal system and prevent the root canal system from bacterial reinfection after root canal therapy(RCT).Recent research,encompassing bacterial etiology and advanced imaging techniques,contributes to our understanding of the root canal system's anatomy intricacies and the technique sensitivity of RCT.Success in RCT hinges on factors like patients,infection severity,root canal anatomy,and treatment techniques.Therefore,improving disease management is a key issue to combat endodontic diseases and cure periapical lesions.The clinical difficulty assessment system of RCT is established based on patient conditions,tooth conditions,root canal configuration,and root canal needing retreatment,and emphasizes pre-treatment risk assessment for optimal outcomes.The findings suggest that the presence of risk factors may correlate with the challenge of achieving the high standard required for RCT.These insights contribute not only to improve education but also aid practitioners in treatment planning and referral decision-making within the field of endodontics.
6.Treatment and follow-up of 82 children with propionic acidemia
Yuhui HU ; Lianshu HAN ; Jun YE ; Wenjuan QIU ; Huiwen ZHANG ; Lili LIANG ; Wenjun JI ; Feng XU ; Ting CHEN ; Shuli CHEN ; Xuefan GU
Chinese Journal of Perinatal Medicine 2021;24(2):105-112
Objective:To investigate the treatment and prognosis of children with propionic acidemia (PA).Methods:This study involved 82 children with PA treated in the Department of Pediatric Endocrinol-ogy and Genetic Metabolism, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine from December 2002 to June 2020. Clinical data, including manifestations, laboratory test results, treatment strategy, and follow-up data, were summarized and analyzed using t-test or Mann-Whitney U test. Results:(1) Among the 82 cases consisting of 50 (61.0%) boys and 32 (39.0%) girls, 59 (72.0%) were diagnosed after clinical onset; 22 (26.8%) were diagnosed by newborn screening, including eight asymptomatic ones; the other one (1.2%) was asymptomatic but confirmed after the diagnosis of PA in the patient's sibling. The average age at first onset was 4.5 months (2 d-5 years) in 73 subjects, of which 28 (38.4%) were early-onset PA (within three months after birth). (2) Cranial MRI was performed on 26 cases, and abnormality was identified in 19 (73.1%) cases. (3) Hyperlactatemia was found in 16 cases among 30(53.3%) who underwent relevant examination with the average lactic acid level of 3.5 (2.1-4.3) μmol/L, while 35 out of 40 patients (87.5%) had hyperammonemia with an average blood ammonia level of 105.4 (34-907) μmol/L. (4) Among the 28 early-onset PA cases, 16 (57.1%) died, and 12 (42.9%) survived. There was no significant difference in the serum propionylcarnitine level, propionylcarnitine to acetylcarnitine ratio, urine 3-hydroxypropionic acid, or methylcitrate level between the survival and death cases. (5) Genetic mutations were detected in 75 patients (91.5%), among which 26 (34.7%) carried PCCA gene mutations and 48 (64%) with PCCB gene mutations. One patient (1.3%) harbored one known pathogenic mutation in each of the PCCA and PCCB genes. All mutations were inherited from the parents. (6) Followed up to June 2020, 57 (69.5%) patients survived, and 25 (30.5%) died from multiple organ failure secondary to severe acidosis, including 16 early-onset and nine late-onset cases. Conclusions:The primary treatment of PA is dietary control. Most PA patients are diagnosed after clinical onset, but symptoms may recur and even have developmental retardation despite treatment. Some of those diagnosed through newborn screening are asymptomatic after treatment. Newborn screening using tandem mass spectrometry is recommended for early diagnosis and treatment of PA.
7.Agitated behaviors among institutionalized elderly with dementia in Guangzhou city
Fen YE ; 广州医科大学附属第一医院胃肠外科 ; Jing ZHENG ; Liming YOU ; Shuli LIAO ; Lu XIAO
Chinese Journal of Practical Nursing 2017;33(34):2660-2665
Objective To investigate the current status of agitated behaviors among institutionalized elderly with dementia. Methods The Cohen-Mansfield Agitation Inventory (CMAI) and General Information questionnaire were used to collect information of agitated behaviors among 141 institutionalized elderly with dementia in a long-term care facility in Guangzhou. Results Nearly 90.07%(127/141) of the elderly with dementia had the symptoms of agitation. Among the four categories of the agitated behaviors, the incidence for physically non-aggressive behaviors (82.27%, 116/141) was the highest, followed by physically aggressive behaviors (78.72% , 111/141), verbally non- aggressive behaviors (74.47%, 105/141) and verbally aggressive behaviors (64.54%, 91/141). Spitting, repetitive sentences or questions, complaining occurred frequently. Conclusions The incidence of the agitated behaviors was high and the manifestation and types of agitated behaviors were varied, which should be paid attention to by the institution. It is necessary to develop the personalized, systematic, standardized nursing intervention to provide the support for caregivers and help the elderly with dementia to cope with agitation.
8.Structural optimization and biological evaluation of 1,5-disubstituted pyrazole-3-carboxamines as potent inhibitors of human 5-lipoxygenase.
Yu ZHOU ; Jun LIU ; Mingyue ZHENG ; Shuli ZHENG ; Chunyi JIANG ; Xiaomei ZHOU ; Dong ZHANG ; Jihui ZHAO ; Deju YE ; Mingfang ZHENG ; Hualiang JIANG ; Dongxiang LIU ; Jian CHENG ; Hong LIU
Acta Pharmaceutica Sinica B 2016;6(1):32-45
Human 5-lipoxygenase (5-LOX) is a well-validated drug target and its inhibitors are potential drugs for treating leukotriene-related disorders. Our previous work on structural optimization of the hit compound 2 from our in-house collection identified two lead compounds, 3a and 3b, exhibiting a potent inhibitory profile against 5-LOX with IC50 values less than 1 µmol/L in cell-based assays. Here, we further optimized these compounds to prepare a class of novel pyrazole derivatives by opening the fused-ring system. Several new compounds exhibited more potent inhibitory activity than the lead compounds against 5-LOX. In particular, compound 4e not only suppressed lipopolysaccharide-induced inflammation in brain inflammatory cells and protected neurons from oxidative toxicity, but also significantly decreased infarct damage in a mouse model of cerebral ischemia. Molecular docking analysis further confirmed the consistency of our theoretical results and experimental data. In conclusion, the excellent in vitro and in vivo inhibitory activities of these compounds against 5-LOX suggested that these novel chemical structures have a promising therapeutic potential to treat leukotriene-related disorders.
9.COMMUNITY MANAGEMENT AND FAMILY CARE OF CHILDREN WITH INTELLECTUAL DISABILITIES
Modern Hospital 2014;(8):147-148,151
Objective To explore for mentally challenged children, their families after the implementation of com-munity-based management and care, the effect obtained performance.Methods Select mentally disabled children 150 ca-ses as the research object of this experiment, implement necessary community management intervention for children and to give the necessary family care, mainly include the children carry out health education, existence education and encourage children to participate in training activities, etc.Comparing the patient′s psychological state before and after the intervention and the quality of life scores.Results Before the intervention and post-intervention comparison found that children in ath-letic ability, the ability to understand the performance aspects of quality of life scores, and a very significant improvement (p<0.05).In terms of children with inner feelings, after giving intervention also received a significant effect, children with heart felt warm enough.Conclusion For the mentally challenged children, to give them the necessary community manage-ment and home care, improving the quality of life in children with intellectual disabilities and children with enhanced inner feelings, etc., have shown a very significant meaning, highlights the success of community management and family care Ap-plication significance.
10.Prenatal diagnosis and perinatal management of 30 cases of meconium peritonitis
Jidong MA ; Cuizhu FENG ; Ying WANG ; Yue ZHANG ; Zhenzhen YE ; Shuli LIU
Chinese Journal of Perinatal Medicine 2013;16(11):668-672
Objective To investigate the efficacy of standardized protocol,including prenatal diagnosis,perinatal management and treatment,on babies with meconium peritonitis.Methods A standardized protocol with prenatal diagnosis,perinatal management,treatment and follow-up on congenital anomaly was founded by Capital Institute of Pediatrics and several other obstetric hospitals.Thirty neonates diagnosed as meconium peritonitis prenatally from March 15,2006 to August 27,2012 were intervened according to this protoccl.The data of diagnosis,treatment after birth and prognosis were analyzed.Results (1) Prenatal diagnosis:Abnormal meconium peritonitis relative signs were found by ultrasound in all of these 30 cases.Among them,23 cases presented with intestine dilation,15 with polyhydromnios,nine with ascites,four with abdominal cystic mass and four calcification.(2)Diagnosis after birth (n=27):The most common imaging findings in abdominal X-ray were distention (27 cases),dilated intestine with air-fluid levels (22 cases) and calcification (11 cases).The most common imaging findings in ultrasound were obvious intestinal dilation (19 cases),cystic mass (7 cases) and calcification (7 cases).(3) Operation:Except for three cases without symptoms,the other 27 infants received operation at averagely 42 hours after birth (12 h-5 d).Besides the basic treatment as removal of the fuci and dissection of adhesion,peritoneal drainage was performed in one infant,two-stoma enterostomy in seven infants,inverted T-shape enterostomy in eight infants and primary intestinal anastomosis in 11 infants.Among these 27 cases,24 cases were cured,2 cases refused following treatment after surgery and one case was lost to follow up.Conclusions Standardized protocol with prenatal diagnosis,perinatal management and earlier intervention might improve the prognosis of meconium peritonitis.

Result Analysis
Print
Save
E-mail