1.Reassessment of non-acute occlusion in intracranial flow diverter implantation: an animal experimental study based on optical coherence tomography, intravascular ultrasound, and pathological correlation
Zhuangzhuang WEI ; Qi TIAN ; Shuailong SHI ; Jie YANG ; Ji MA ; Zhen LI ; Haiqiang SANG ; Yi TANG ; Yuncai RAN ; Yong ZHANG ; Baohong WEN ; Shanshan XIE ; Jinjuan CHEN ; Enjie LIU ; Xinwei HAN ; Tengfei LI
Chinese Journal of Neurology 2025;58(6):607-614
Objective:To investigate and summarize the imaging and pathological features of non-acute occlusion following flow diverter (FD) implantation in animal models.Methods:Four experimental pigs (experimental group) that experienced non-acute occlusion (occlusion time exceeding 24 hours) within the FD stent implanted in the common carotid artery, and 19 pigs (control group) that did not experience stent occlusion during the same period were involved. Using an interventional approach under digital subtraction angiography (DSA), the 4 occluded FD lumens were mechanically opened. Optical coherence tomography (OCT), intravascular ultrasound (IVUS) and histopathological examinations were performed to evaluate the intraluminal composition and characteristics of the occlusive tissues. These findings were compared with non-occluded FD stents to summarize the imaging and pathological changes within the occluded FD lumen.Results:The occlusion times of the FD stents in the 4 experimental pigs were 16 weeks, 20 weeks, 20 weeks, and 24 weeks postoperatively. All occluded stents were successfully recanalized under DSA, with a technical success rate of 4/4. Among the 19 non-occluded FD stents, OCT and IVUS revealed uniform (16 stents) or non-uniform (3 stents) neointimal coverage of the stent struts, presenting as homogeneous high/slightly high signal intensity or medium echogenicity. Histopathological examination indicated that the neointima was primarily composed of smooth muscle cells and a small amount of fibrous connective tissues. In contrast, the 4 occluded FD stents demonstrated excessive neointimal proliferation and plaque formation, leading to luminal loss, as shown by OCT and IVUS. The occlusion tissues predominantly presented as homogeneous high signal intensity with weak attenuation (fibrous plaques) on OCT, with some regions showing blurred low signal intensity and strong attenuation (lipid plaques). IVUS presented homogeneous echogenicity (fibrous plaques) and hypoechogenic zones (lipid plaques). Histopathological examination showed that the occlusion tissues mainly consisted of smooth muscle cells, fibrous connective tissues, and lipids, accompanied by numerous foam cells and a minor presence of inflammatory cells.Conclusions:Histopathological examinations confirm that non-acute occlusion of FD is mainly caused by excessive hyperplasia of intima along with the formation of fibrous plaques and lipid plaques. OCT and IVUS have typical finding in imaging that can assist in determining the cause of stent occlusion as well as the lesion's nature, thereby providing crucial guidance for subsequent clinical treatment and drug selection.
2.Impact of flow diverter malapposition at the aneurysm neck on clinical outcomes and complications of intracranial aneurysms
Jie YANG ; Shuhai LONG ; Shuailong SHI ; Yukun HOU ; Ji MA ; Ye WANG ; Sheng GUAN ; Tengfei LI
Chinese Journal of Neuromedicine 2025;24(6):599-608
Objective:To investigate the impact of flow diverter (FD) malapposition at the aneurysm neck on clinical outcomes and complications of intracranial aneurysms, and identify the influencing factors for intraoperative FD malapposition.Methods:A retrospective study was performed; 153 patients with unruptured saccular aneurysms at the C4-C7 segments of the internal carotid artery accepted single FD implantation at Department of Interventional Radiology, First Affiliated Hospital of Zhengzhou University from June 2022 to March 2024 were chosen. Intraoperative high-resolution C-arm CT was utilized to assess FD apposition at the aneurysm neck. (1) Based on FD apposition at the aneurysm neck as shown, these 153 patients were divided into a malapposition group ( n=23, including 16 patients with malapposition being identified as residual malapposition after intraoperative corrective measures such as microwire massage and 7 patients with malapposition being newly detected in this study) and a complete apposition group ( n=130). Perioperative and follow-up complications were recorded. Clinical outcomes were assessed using modified Rankin Scale (mRS) at the final follow-up (mRS score of 0-2 as favorable outcome), and angiographic outcomes were evaluated by DSA at the final follow-up. Differences in clinical and angiographic outcomes and complication rate were compared between the malapposition group and complete apposition group. (2) Based on FD apposition at the aneurysm neck as shown, these 153 patients were divided into an intraoperative malapposition group ( n=74, including 67 patients with malapposition being detected during surgery and 7 patients with malapposition being newly detected in this study) and an intraoperative complete apposition group ( n=79). Univariate analysis was performed to compare the clinical variables between the intraoperative malapposition group and intraoperative complete apposition group; multivariate Logistic regression was further employed to identify the independent influencing factors for FD malapposition at the aneurysm neck. Results:(1) Four patients (all from the malapposition group) developed perioperative acute in-stent thrombosis. Nine patients experienced ischemic or hemorrhagic stroke during the follow-up, including 6 from the malapposition group and 3 from the complete apposition group; the complication rate in the malapposition group (6/23, 26.1%) was significantly higher than that in the complete apposition group (3/130, 2.3%) during the follow-up ( P<0.05). At the final follow-up, 2 patients (both from the malapposition group) had poor clinical outcome, while the remaining 151 patients had favorable outcome. Proportion of patients with favorable outcome between the two groups was statistically different (91.3%[21/23] vs. 100.0%[130/130], P<0.05). Delayed occlusion was detected in 46 patients (12 from the malapposition group and 34 from the complete apposition group) at the final angiographic follow-up. FD restenosis/re-occlusion was noted in 10 patients, including 6 from the malapposition group and 4 from the complete apposition group. Significant difference in delayed occlusion rate (52.2%[12/23] vs. 26.2%[34/130]) and long-term in-stent stenosis/occlusion rate (26.1%[6/23] vs. 3.1%[4/130]) was observed between the two groups ( P<0.05). (2) Significant difference in aneurysm neck diameter, FD angulation, parent artery stenosis, parent artery diameter ratio>1.2, and presence of branching vessels at the FD implantation site was noted between the intraoperative complete apposition group and intraoperative malapposition group ( P<0.05). Multivariate Logistic regression indicated that aneurysm neck diameter ( OR=1.431, 95% CI: 1.096-1.868, P=0.008), parent artery diameter ratio>1.2 ( OR=2.199, 95% CI: 1.083-4.463, P=0.029), and FD angulation ( OR=1.019, 95% CI: 1.002-1.036, P=0.027) were independent influencing factors for FD malapposition at the aneurysm neck. Conclusion:In FD implantation for intracranial aneurysms, FD malapposition at the aneurysm neck adversely affects delayed occlusion rate and complication rate; aneurysms with wider aneurysm neck diameter, parent artery diameter ratio>1.2, and greater FD angulation are trend to have FD malapposition at the aneurysm neck.
3.Reassessment of non-acute occlusion in intracranial flow diverter implantation: an animal experimental study based on optical coherence tomography, intravascular ultrasound, and pathological correlation
Zhuangzhuang WEI ; Qi TIAN ; Shuailong SHI ; Jie YANG ; Ji MA ; Zhen LI ; Haiqiang SANG ; Yi TANG ; Yuncai RAN ; Yong ZHANG ; Baohong WEN ; Shanshan XIE ; Jinjuan CHEN ; Enjie LIU ; Xinwei HAN ; Tengfei LI
Chinese Journal of Neurology 2025;58(6):607-614
Objective:To investigate and summarize the imaging and pathological features of non-acute occlusion following flow diverter (FD) implantation in animal models.Methods:Four experimental pigs (experimental group) that experienced non-acute occlusion (occlusion time exceeding 24 hours) within the FD stent implanted in the common carotid artery, and 19 pigs (control group) that did not experience stent occlusion during the same period were involved. Using an interventional approach under digital subtraction angiography (DSA), the 4 occluded FD lumens were mechanically opened. Optical coherence tomography (OCT), intravascular ultrasound (IVUS) and histopathological examinations were performed to evaluate the intraluminal composition and characteristics of the occlusive tissues. These findings were compared with non-occluded FD stents to summarize the imaging and pathological changes within the occluded FD lumen.Results:The occlusion times of the FD stents in the 4 experimental pigs were 16 weeks, 20 weeks, 20 weeks, and 24 weeks postoperatively. All occluded stents were successfully recanalized under DSA, with a technical success rate of 4/4. Among the 19 non-occluded FD stents, OCT and IVUS revealed uniform (16 stents) or non-uniform (3 stents) neointimal coverage of the stent struts, presenting as homogeneous high/slightly high signal intensity or medium echogenicity. Histopathological examination indicated that the neointima was primarily composed of smooth muscle cells and a small amount of fibrous connective tissues. In contrast, the 4 occluded FD stents demonstrated excessive neointimal proliferation and plaque formation, leading to luminal loss, as shown by OCT and IVUS. The occlusion tissues predominantly presented as homogeneous high signal intensity with weak attenuation (fibrous plaques) on OCT, with some regions showing blurred low signal intensity and strong attenuation (lipid plaques). IVUS presented homogeneous echogenicity (fibrous plaques) and hypoechogenic zones (lipid plaques). Histopathological examination showed that the occlusion tissues mainly consisted of smooth muscle cells, fibrous connective tissues, and lipids, accompanied by numerous foam cells and a minor presence of inflammatory cells.Conclusions:Histopathological examinations confirm that non-acute occlusion of FD is mainly caused by excessive hyperplasia of intima along with the formation of fibrous plaques and lipid plaques. OCT and IVUS have typical finding in imaging that can assist in determining the cause of stent occlusion as well as the lesion's nature, thereby providing crucial guidance for subsequent clinical treatment and drug selection.
4.Impact of flow diverter malapposition at the aneurysm neck on clinical outcomes and complications of intracranial aneurysms
Jie YANG ; Shuhai LONG ; Shuailong SHI ; Yukun HOU ; Ji MA ; Ye WANG ; Sheng GUAN ; Tengfei LI
Chinese Journal of Neuromedicine 2025;24(6):599-608
Objective:To investigate the impact of flow diverter (FD) malapposition at the aneurysm neck on clinical outcomes and complications of intracranial aneurysms, and identify the influencing factors for intraoperative FD malapposition.Methods:A retrospective study was performed; 153 patients with unruptured saccular aneurysms at the C4-C7 segments of the internal carotid artery accepted single FD implantation at Department of Interventional Radiology, First Affiliated Hospital of Zhengzhou University from June 2022 to March 2024 were chosen. Intraoperative high-resolution C-arm CT was utilized to assess FD apposition at the aneurysm neck. (1) Based on FD apposition at the aneurysm neck as shown, these 153 patients were divided into a malapposition group ( n=23, including 16 patients with malapposition being identified as residual malapposition after intraoperative corrective measures such as microwire massage and 7 patients with malapposition being newly detected in this study) and a complete apposition group ( n=130). Perioperative and follow-up complications were recorded. Clinical outcomes were assessed using modified Rankin Scale (mRS) at the final follow-up (mRS score of 0-2 as favorable outcome), and angiographic outcomes were evaluated by DSA at the final follow-up. Differences in clinical and angiographic outcomes and complication rate were compared between the malapposition group and complete apposition group. (2) Based on FD apposition at the aneurysm neck as shown, these 153 patients were divided into an intraoperative malapposition group ( n=74, including 67 patients with malapposition being detected during surgery and 7 patients with malapposition being newly detected in this study) and an intraoperative complete apposition group ( n=79). Univariate analysis was performed to compare the clinical variables between the intraoperative malapposition group and intraoperative complete apposition group; multivariate Logistic regression was further employed to identify the independent influencing factors for FD malapposition at the aneurysm neck. Results:(1) Four patients (all from the malapposition group) developed perioperative acute in-stent thrombosis. Nine patients experienced ischemic or hemorrhagic stroke during the follow-up, including 6 from the malapposition group and 3 from the complete apposition group; the complication rate in the malapposition group (6/23, 26.1%) was significantly higher than that in the complete apposition group (3/130, 2.3%) during the follow-up ( P<0.05). At the final follow-up, 2 patients (both from the malapposition group) had poor clinical outcome, while the remaining 151 patients had favorable outcome. Proportion of patients with favorable outcome between the two groups was statistically different (91.3%[21/23] vs. 100.0%[130/130], P<0.05). Delayed occlusion was detected in 46 patients (12 from the malapposition group and 34 from the complete apposition group) at the final angiographic follow-up. FD restenosis/re-occlusion was noted in 10 patients, including 6 from the malapposition group and 4 from the complete apposition group. Significant difference in delayed occlusion rate (52.2%[12/23] vs. 26.2%[34/130]) and long-term in-stent stenosis/occlusion rate (26.1%[6/23] vs. 3.1%[4/130]) was observed between the two groups ( P<0.05). (2) Significant difference in aneurysm neck diameter, FD angulation, parent artery stenosis, parent artery diameter ratio>1.2, and presence of branching vessels at the FD implantation site was noted between the intraoperative complete apposition group and intraoperative malapposition group ( P<0.05). Multivariate Logistic regression indicated that aneurysm neck diameter ( OR=1.431, 95% CI: 1.096-1.868, P=0.008), parent artery diameter ratio>1.2 ( OR=2.199, 95% CI: 1.083-4.463, P=0.029), and FD angulation ( OR=1.019, 95% CI: 1.002-1.036, P=0.027) were independent influencing factors for FD malapposition at the aneurysm neck. Conclusion:In FD implantation for intracranial aneurysms, FD malapposition at the aneurysm neck adversely affects delayed occlusion rate and complication rate; aneurysms with wider aneurysm neck diameter, parent artery diameter ratio>1.2, and greater FD angulation are trend to have FD malapposition at the aneurysm neck.
5.Clinical study of overlapping Wallstent stent implantation in large or giant extracranial internal carotid artery aneurysms
Qi TIAN ; Shuailong SHI ; Shuhai LONG ; Ji MA ; Ye WANG ; Xiao LI ; Renying MIAO ; Yan SONG ; Tengfei LI
Chinese Journal of Neuromedicine 2024;23(11):1086-1093
Objective:To assess the efficacy and safety of overlapping braided carotid artery stent (Wallstent) implantation in large extracranial internal carotid artery aneurysms (15 mm≤diameter<25 mm) and giant ones (diameter≥25 mm).Methods:A retrospective study was performed; the clinical data of 23 patients with large or giant extracranial internal carotid artery aneurysms accepted overlapping Wallstent stent implantation in Department of Interventional Radiology, First Affiliated Hospital of Zhengzhou University from August 2015 to June 2023 were collected. Immediately after implantation, DSA was used to evaluate the retention of contrast agent within the aneurysms and high-resolution C-arm CT (HR-CBCT) was used to detect the apposition between the two stents and between the stents and inner wall of the blood vessel. Perioperative complications were recorded. Clinical follow-up was performed bi-monthly via outpatient visits or telephone, and modified Rankin scale (mRS) was used to assess the prognoses (mRS scores of 0-2 as good prognosis) at the last follow-up; aneurysm occlusion was evaluated in a 6-month follow-up by DSA and in-stent restenosis in a final imaging follow-up by DSA or CTA according to the OKM grading. Results:Twenty-two patients had successful overlapping implantation of 2 Wallstent stents; blood flow was restricted in one patient due to carotid artery dissection at the distal end of the aneurysm during stent implantation and restored after a Neuroform EZ stent and 2 Wallstent stent implantation from the distal-proximal lesion; technical success rate of 95.7% (22/23) was obtained. DSA immediately after implantation showed obvious contrast medium retention in all aneurysms. HR-CBCT indicated good stent apposition in 21 patients and mild incomplete stent apposition in 2. Clinical follow-up was finished in 23 patients, ranged 6-31 months (mean 11.5±6.3 months); all patients had good prognosis at the last follow-up. Imaging follow-up, including at least once DSA, was conducted for all patients, with intervals ranging from 6 to 15 months (mean 10.4±3.4 months); DSA 6 months after implantation showed complete aneurysm occlusion in 19 patients (OKM grading D) and a bit of residual contrast in 4 patients (OKM grading C); final imaging follow-up (DSA in 2 and CTA in 21) revealed in-stent stenosis in 2 patients (stenosis rates of 51% and 87%) with obvious improved stenosis after balloon angioplasty and patent stents in 21 patients without evidence of aneurysm opacification.Conclusion:Overlapping braided carotid artery stent (Wallstent) implantation is an effective and safe approach for managing large or giant extracranial carotid artery aneurysms.
6.Construction and Application of an Intelligent Health Insurance Development Level Evaluation System Based on the Delphi-Entropy Method
Yuxin YE ; Wenxi TANG ; Shuailong LI ; Qian XING ; Mingyang LI ; Renchang DIAO ; Aixia MA
Chinese Hospital Management 2024;44(2):1-5
Objective It aims to construct an evaluation index system for the development level of intelligent health insurance,which can serve as a reference for health insurance management departments in assessing the develop-ment level of intelligent health insurance and the implementation of health insurance informatization.Methods Key events in intelligent health insurance were identified based on event system theory and text analysis.The evaluation index system was determined through a combination of expert interviews and Delphi expert consultations.The entro-py method was used to calculate the weights of each index,followed by the assessment of the current and ideal de-velopment levels.Results A total of 16 experts were consulted.After two rounds of Delphi expert consultation,two first-level indicators and 18 second-level indicators were finally included in the system.The current development level of intelligent health insurance in China is at the intelligent development stage(2.524 points),while the ideal de-velopment level is at the intelligent improvement stage(4.073 points).The positivity coefficient of both rounds of Del-phi expert consultation was 100%,with an authority coefficient of 0.842,and the degree of expert coordination im-proved with each round.Conclusion The constructed evaluation index system exhibits high scientificity,stability,and generalizability.It can provide an effective evaluation tool for the development of intelligent health insurance in various pooled areas.
7.Construction of Medical Insurance DRG Refined Supervision and Precise Governance System:Take"Medi-cal Insurance High-speed Railway",Nanjing as An Example
Shuailong LI ; Yuxin YE ; Qian XING ; Renchang DIAO ; Wenxi TANG
Chinese Hospital Management 2024;44(2):6-10
Taking the reform of DRG payment methods as the background,it discusses how the medical in-surance department uses information technology to achieve refined monitoring and management of medical institu-tions,so as to improve the quality and efficiency of medical services and control the unreasonable growth of medical expenses.The three stages of"precision monitoring-refined supervision-precision governance"of medical insurance DRG based on"refined theory"are proposed;taking Nanjing's"medical insurance high-speed railway"as an example,a DRG refined supervision and governance model framework is constructed,and its analysis is carried out monitoring elements and governance elements,and finally put forward implementation suggestions,including hori-zontal collaboration led by medical insurance,establishing a service and cost evaluation mechanism that combines in-ternal and external services.
8.Research on the Resilience of Local Health Systems Based on Information Platforms:a Case Study of the Epidemic Prevention Material Procurement and Allocation Hall in Nanjing
Yuxin YE ; Wenxi TANG ; Shuailong LI ; Qian XING ; Renchang DIAO ; Aixia MA
Chinese Hospital Management 2024;44(2):11-14
It dified framework of health system resilience analysis.The research integrates practical elements from the case of the online pandemic material procurement and allocation hall in Nanjing,categorizing the resilience-building of local health systems via informatization into two distinct dimensions:static foundation and dynamic endowment.It conducts an in-depth examination of the logical pathways that leverage informatization to bolster resilience,and further investigates the inherent advantages and potential areas for optimization within informatization.The findings suggest that the synergistic empowerment of both static foundation and dynamic endowment effectively amplifies the risk defense capability and resilience of local health systems.
9.A Study on Collaborative Development and Governance Information Mechanism of the Tripartite System Based on the SFIC Model
Yuxin YE ; Wenxi TANG ; Shuailong LI ; Qian XING ; Renchang DIAO ; Aixia MA
Chinese Hospital Management 2024;44(2):15-19
Information collaboration is an important realisation path to deepen the reform of the medical and health system and to promote the collaborative development and governance of the"Three Medicine"during the"14th Five-Year Plan"period.It employs the SFIC model and makes appropriate modifications to it.The analytical framework comprises six elements:"initial conditions-external environment-catalytic leadership-institutional de-sign-collaborative process-results feedback".This framework is used to dissect the current collaborative dilemma in the"Three Medicine"information collaboration and governance.Based on this analysis,an optimized path for infor-mation collaborative governance is proposed:consolidating the foundation of"Three Medicine"information collabora-tion,enhancing the catalytic leadership capability of meta-governance,optimizing the institutional design of informa-tion life-cycle governance,reshaping the information collaboration process,and focusing on the evaluation feedback mechanism.
10.Vascular suture, closure and occlusion devices at femoral artery puncture hemostasis after neuro-intervention: a clinical comparative study
Shuailong SHI ; Shuhai LONG ; Sun YU ; Chengcheng SHI ; Ji MA ; Renying MIAO ; Yan SONG ; Xinwei HAN ; Tengfei LI
Chinese Journal of Radiology 2024;58(1):71-78
Methods:From February 2018 to January 2022, the clinical data of 1 123 patients who underwent Starclose vascular closure device, Angio-Seal and Exoseal vascular occlusion devices and Perclose ProGlide vascular suture device at femoral artery puncture hemostasis after neuro-intervention, in the Department of Interventional Radiology (Eastern District), The First Affiliated Hospital of Zhengzhou University, were retrospectively analyzed. The patients were divided into three groups based on the intervention method: the closure group (Starclose, n=271), the occlusion group (Angio-Seal, n=327 and Exoseal, n=352) and the suture group (ProGlide, n=173). Next, the hemostatic efficacy and complications associated with the three devices were analyzed and compared. Additionally, regression analysis was conducted to identify any relevant factors that may contribute to complications. Results:Three vascular hemostatic devices demonstrated effective hemostasis and the success rate were 92.6% in the closure group (Starclose), 93.4% in the occlusion group (Angio-Seal 93.0% and Exoseal 93.8%) and 89.6% in the suture group (ProGlide). There was no statistically significant difference( χ2=3.026, P=0.388). Single or multiple complications were observed in 102 patients (9.1%), including local oozing (16 cases in the closure group, 39 cases in the occlusion group, 13 cases in the suture group), local hematoma (14 cases in the closure group, 31 cases in the occlusion group, 11 cases in the suture group), pseudoaneurysm (13 cases in the closure group, 35 cases in the occlusion group, 10 cases in the suture group), local infection (2 cases in the closure group, 3 cases in the occlusion group, 1 case in the suture group). There were no statistically significant differences ( P>0.05). Moreover, serious complications such as femoral artery occlusion, embolus shedding and permanent nerve injury weren′t observed in the three groups. Multivariate logistic regression analysis revealed that overweight ( OR=1.562,95% CI 1.023—2.385, P=0.039), femoral artery with calcified plaque ( OR=1.934,95% CI 1.172-3.189, P=0.010), combined use of multiple antiplatelet drugs ( OR=1.769,95% CI 1.103—2.839, P=0.018), use of an 8F sheath( OR=2.824,95% CI 1.406—5.671, P=0.004) and the operator′s proficiency ( OR=0.508,95% CI 0.328—0.788, P=0.002) were the independent factors influencing complications, of which the first four were identified as risk-promoting factors for complications while the operator′s rich experience and high proficiency were the protective factors. Conclusions:Three hemostatic devices demonstrate effective hemostasis and comparable rates of complications at femoral artery puncture hemostasis after neuro-intervention. Overweight, femoral artery with calcified plaque, combined use of multiple antiplatelet drugs, use of an 8 F sheath and the operator′s proficiency were independent factors influencing complications.Ojective:To investigate the efficacy and complications associated with vascular suture, closure and occlusion devices at femoral artery puncture hemostasis after neuro-intervention.

Result Analysis
Print
Save
E-mail