1.Risk prediction of Reduning Injection batches by near-infrared spectroscopy combined with multiple machine learning algorithms.
Wen-Yu JIA ; Feng TONG ; Heng-Xu LIU ; Shu-Qin JIN ; Yong-Chao ZHANG ; Chen-Feng ZHANG ; Zhen-Zhong WANG ; Xin ZHANG ; Wei XIAO
China Journal of Chinese Materia Medica 2025;50(2):430-438
In this paper, near-infrared spectroscopy(NIRS) was employed to analyze 129 batches of commercial products of Reduning Injection. The batch reporting rate was estimated according to the report of Reduning Injection in the direct adverse drug reaction(ADR) reporting system of the drug marketing authorization holder of the Center for Drug Reevaluation of the National Medical Products Administration(National Center for ADR Monitoring) from August 2021 to August 2022. According to the batch reporting rate, the samples of Reduning Injection were classified into those with potential risks and those being safe. No processing, random oversampling(ROS), random undersampling(RUS), and synthetic minority over-sampling technique(SMOTE) were then employed to balance the unbalanced data. After the samples were classified according to appropriate sampling methods, competitive adaptive reweighted sampling(CARS), successive projections algorithm(SPA), uninformative variables elimination(UVE), and genetic algorithm(GA) were respectively adopted to screen the features of spectral data. Then, support vector machine(SVM), logistic regression(LR), k-nearest neighbors(KNN), naive bayes(NB), random forest(RF), and artificial neural network(ANN) were adopted to establish the risk prediction models. The effects of the four feature extraction methods on the accuracy of the models were compared. The optimal method was selected, and bayesian optimization was performned to optimize the model parameters to improve the accuracy and robustness of model prediction. To explore the correlations between potential risks of clinical use and quality test data, TreeNet was employed to identify potential quality parameters affecting the clinical safety of Reduning Injection. The results showed that the models established with the SVM, LR, KNN, NB, RF, and ANN algorithms had the F1 scores of 0.85, 0.85, 0.86, 0.80, 0.88, and 0.85 and the accuracy of 88%, 88%, 88%, 85%, 91%, and 88%, respectively, and the prediction time was less than 5 s. The results indicated that the established models were accurate and efficient. Therefore, near infrared spectroscopy combined with machine learning algorithms can quickly predict the potential risks of clinical use of Reduning Injection in batches. Three key quality parameters that may affect clinical safety were identified by TreeNet, which provided a scientific basis for improving the safety standards of Reduning Injection.
Spectroscopy, Near-Infrared/methods*
;
Drugs, Chinese Herbal/administration & dosage*
;
Machine Learning
;
Algorithms
;
Humans
;
Quality Control
2.Evidence-based guidelines for rehabilitation treatment after internal fixation of thoracolumbar spine fracture in adults (version 2025)
Zhengwei XU ; Liming CHENG ; Qixin CHEN ; Jian DONG ; Shunwu FAN ; Zhong FANG ; Shiqing FENG ; Haoyu FENG ; Haishan GUAN ; Weimin JIANG ; Dianming JIANG ; Yong HAI ; Lijun HE ; Yuan HE ; Bo LI ; Jianjun LI ; Feng LI ; Li LI ; Weishi LI ; Chunde LI ; Qi LIAO ; Baoge LIU ; Xiaoguang LIU ; Yong LIU ; Xuhua LU ; Shibao LU ; Bin LIN ; Wei MEI ; Chao MA ; Renfu QUAN ; Limin RONG ; Jiacan SU ; Honghui SUN ; Yuemin SONG ; Hongxun SANG ; Jun SHU ; Tiansheng SUN ; Jiwei TIAN ; Qiang WANG ; Xinwei WANG ; Zhe WANG ; Zheng WANG ; Liang YAN ; Guoyong YIN ; Jie ZHAO ; Yue ZHU ; Xiaobo ZHANG ; Xuesong ZHANG ; Zhongmin ZHANG ; Rongqiang ZHANG ; Dingjun HAO ; Yanzheng GAO ; Baorong HE
Chinese Journal of Trauma 2025;41(1):19-32
Thoracolumbar spine fracture often leads to severe pain, functional impairments, and neurological deficits, for which open reduction and internal fixation can effectively restore the spinal structural stability. Open decompression and reduction with internal fixation can help relieve spinal cord compression and improve spinal function in cases of concomitant cord injury. Although spinal stability can be restored through surgery, patients often face chronic pain and functional impairments postoperatively. A postoperative rehabilitation program is critical in optimizing therapeutic outcomes, reducing complications, and minimizing the risk of secondary injuries. However, current rehabilitation methods, such as physical therapy, functional training, and pain management, are confronted with problems in clinical practice, including significant variation in efficacy, poor patient adherence, and prolonged rehabilitation period. There is an urgent need for a unified rehabilitation strategy to address these problems. To this end, the Spinal Trauma Group of the Orthopedic Physicians Branch of the Chinese Medical Association and the Spine Health Professional Committee of the Chinese Human Health Technology Promotion Association organized experts from relevant fields to formulate Evidence-based guidelines for rehabilitation treatment after internal fixation of thoracolumbar spine fracture in adults ( version 2025) by integrating evidences from clinical researches and advanced rehabilitation concepts at home and abroad. A total number of 14 recommendations concerning the rehabilitation treatment with multimodal analgesia, psychological intervention, deep vein thrombosis prevention, core muscle and extremity exercise, appropriate use of braces, early weight-bearing, device-aided rehabilitation exercise, neuroregulatory therapy, rehabilitation team were put forward, aiming to standardize the post-operative rehabilitation process following internal fixation, promote the functional recovery, and enhance patients′ quality of life.
3.Clinical guideline for vertebral augmentation of acute symptomatic osteoporotic thoracolumbar compression fractures (version 2025)
Bolong ZHENG ; Wei MEI ; Yanzheng GAO ; Liming CHENG ; Jian CHEN ; Qixin CHEN ; Liang CHEN ; Xigao CHENG ; Jian DONG ; Jin FAN ; Shunwu FAN ; Xiangqian FANG ; Zhong FANG ; Shiqing FENG ; Haoyu FENG ; Haishan GUAN ; Yong HAI ; Baorong HE ; Lijun HE ; Yuan HE ; Hua HUI ; Weimin JIANG ; Junjie JIANG ; Dianming JIANG ; Xuewen KANG ; Hua GUO ; Jianjun LI ; Feng LI ; Li LI ; Weishi LI ; Chunde LI ; Qi LIAO ; Baoge LIU ; Xiaoguang LIU ; Xuhua LU ; Shibao LU ; Bin LIN ; Chao MA ; Xuexiao MA ; Renfu QUAN ; Limin RONG ; Honghui SUN ; Tiansheng SUN ; Yueming SONG ; Hongxun SANG ; Jun SHU ; Jiacan SU ; Jiwei TIAN ; Xinwei WANG ; Zhe WANG ; Zheng WANG ; Zhengwei XU ; Huilin YANG ; Jiancheng YANG ; Liang YAN ; Feng YAN ; Guoyong YIN ; Xuesong ZHANG ; Zhongmin ZHANG ; Jie ZHAO ; Yuhong ZENG ; Yue ZHU ; Rongqiang ZHANG
Chinese Journal of Trauma 2025;41(9):805-818
Acute symptomatic osteoporotic thoracolumbar compression fracture (ASOTLF) can lead to chronic low back pain, kyphosis deformity, pulmonary dysfunction, loss of mobility, and even life-threatening complications. Vertebral augmentation is currently the mainstream treatment method for this condition. In 2019, the Editorial Board of Chinese Journal of Trauma and the Spinal Trauma Group of Orthopedic Surgeons Branch of Chinese Medical Doctor Association collaboratively led the development of Clinical guideline for vertebral augmentation for acute symptomatic osteoporotic thoracolumbar compression fractures. Six years later, with advances in clinical diagnosis and treatment techniques as well as accumulating evidence in related fields, the 2019 guideline requires updating. To this end, the Spinal Trauma Group of Orthopedic Surgeons Branch of Chinese Medical Doctor Association, the Spinal Health Professional Committee of China Human Health Science and Technology Promotion Association, and the Minimally Invasive Orthopedics Professional Committee of Shaanxi Medical Doctor Association have organized experts in the field to develop the Clinical guideline for vertebral augmentation of acute symptomatic osteoporotic thoracolumbar compression fractures ( version 2025) , based on the latest evidence-based medical researches. This guideline incorporates 3 recommendations retained from the 2019 version with updated strength of evidence, along with 12 new recommendations. It provides recommendations from six aspects of diagnosis, pain management, treatment option selection, prevention of postoperative complications, anti-osteoporosis therapy, and postoperative rehabilitation, aiming to provide a reference for standard treatment of vertebral augmentation for ASOTLF in hospitals at all levels.
4.Evidence-based guidelines for rehabilitation treatment after internal fixation of thoracolumbar spine fracture in adults (version 2025)
Zhengwei XU ; Liming CHENG ; Qixin CHEN ; Jian DONG ; Shunwu FAN ; Zhong FANG ; Shiqing FENG ; Haoyu FENG ; Haishan GUAN ; Weimin JIANG ; Dianming JIANG ; Yong HAI ; Lijun HE ; Yuan HE ; Bo LI ; Jianjun LI ; Feng LI ; Li LI ; Weishi LI ; Chunde LI ; Qi LIAO ; Baoge LIU ; Xiaoguang LIU ; Yong LIU ; Xuhua LU ; Shibao LU ; Bin LIN ; Wei MEI ; Chao MA ; Renfu QUAN ; Limin RONG ; Jiacan SU ; Honghui SUN ; Yuemin SONG ; Hongxun SANG ; Jun SHU ; Tiansheng SUN ; Jiwei TIAN ; Qiang WANG ; Xinwei WANG ; Zhe WANG ; Zheng WANG ; Liang YAN ; Guoyong YIN ; Jie ZHAO ; Yue ZHU ; Xiaobo ZHANG ; Xuesong ZHANG ; Zhongmin ZHANG ; Rongqiang ZHANG ; Dingjun HAO ; Yanzheng GAO ; Baorong HE
Chinese Journal of Trauma 2025;41(1):19-32
Thoracolumbar spine fracture often leads to severe pain, functional impairments, and neurological deficits, for which open reduction and internal fixation can effectively restore the spinal structural stability. Open decompression and reduction with internal fixation can help relieve spinal cord compression and improve spinal function in cases of concomitant cord injury. Although spinal stability can be restored through surgery, patients often face chronic pain and functional impairments postoperatively. A postoperative rehabilitation program is critical in optimizing therapeutic outcomes, reducing complications, and minimizing the risk of secondary injuries. However, current rehabilitation methods, such as physical therapy, functional training, and pain management, are confronted with problems in clinical practice, including significant variation in efficacy, poor patient adherence, and prolonged rehabilitation period. There is an urgent need for a unified rehabilitation strategy to address these problems. To this end, the Spinal Trauma Group of the Orthopedic Physicians Branch of the Chinese Medical Association and the Spine Health Professional Committee of the Chinese Human Health Technology Promotion Association organized experts from relevant fields to formulate Evidence-based guidelines for rehabilitation treatment after internal fixation of thoracolumbar spine fracture in adults ( version 2025) by integrating evidences from clinical researches and advanced rehabilitation concepts at home and abroad. A total number of 14 recommendations concerning the rehabilitation treatment with multimodal analgesia, psychological intervention, deep vein thrombosis prevention, core muscle and extremity exercise, appropriate use of braces, early weight-bearing, device-aided rehabilitation exercise, neuroregulatory therapy, rehabilitation team were put forward, aiming to standardize the post-operative rehabilitation process following internal fixation, promote the functional recovery, and enhance patients′ quality of life.
5.Clinical guideline for vertebral augmentation of acute symptomatic osteoporotic thoracolumbar compression fractures (version 2025)
Bolong ZHENG ; Wei MEI ; Yanzheng GAO ; Liming CHENG ; Jian CHEN ; Qixin CHEN ; Liang CHEN ; Xigao CHENG ; Jian DONG ; Jin FAN ; Shunwu FAN ; Xiangqian FANG ; Zhong FANG ; Shiqing FENG ; Haoyu FENG ; Haishan GUAN ; Yong HAI ; Baorong HE ; Lijun HE ; Yuan HE ; Hua HUI ; Weimin JIANG ; Junjie JIANG ; Dianming JIANG ; Xuewen KANG ; Hua GUO ; Jianjun LI ; Feng LI ; Li LI ; Weishi LI ; Chunde LI ; Qi LIAO ; Baoge LIU ; Xiaoguang LIU ; Xuhua LU ; Shibao LU ; Bin LIN ; Chao MA ; Xuexiao MA ; Renfu QUAN ; Limin RONG ; Honghui SUN ; Tiansheng SUN ; Yueming SONG ; Hongxun SANG ; Jun SHU ; Jiacan SU ; Jiwei TIAN ; Xinwei WANG ; Zhe WANG ; Zheng WANG ; Zhengwei XU ; Huilin YANG ; Jiancheng YANG ; Liang YAN ; Feng YAN ; Guoyong YIN ; Xuesong ZHANG ; Zhongmin ZHANG ; Jie ZHAO ; Yuhong ZENG ; Yue ZHU ; Rongqiang ZHANG
Chinese Journal of Trauma 2025;41(9):805-818
Acute symptomatic osteoporotic thoracolumbar compression fracture (ASOTLF) can lead to chronic low back pain, kyphosis deformity, pulmonary dysfunction, loss of mobility, and even life-threatening complications. Vertebral augmentation is currently the mainstream treatment method for this condition. In 2019, the Editorial Board of Chinese Journal of Trauma and the Spinal Trauma Group of Orthopedic Surgeons Branch of Chinese Medical Doctor Association collaboratively led the development of Clinical guideline for vertebral augmentation for acute symptomatic osteoporotic thoracolumbar compression fractures. Six years later, with advances in clinical diagnosis and treatment techniques as well as accumulating evidence in related fields, the 2019 guideline requires updating. To this end, the Spinal Trauma Group of Orthopedic Surgeons Branch of Chinese Medical Doctor Association, the Spinal Health Professional Committee of China Human Health Science and Technology Promotion Association, and the Minimally Invasive Orthopedics Professional Committee of Shaanxi Medical Doctor Association have organized experts in the field to develop the Clinical guideline for vertebral augmentation of acute symptomatic osteoporotic thoracolumbar compression fractures ( version 2025) , based on the latest evidence-based medical researches. This guideline incorporates 3 recommendations retained from the 2019 version with updated strength of evidence, along with 12 new recommendations. It provides recommendations from six aspects of diagnosis, pain management, treatment option selection, prevention of postoperative complications, anti-osteoporosis therapy, and postoperative rehabilitation, aiming to provide a reference for standard treatment of vertebral augmentation for ASOTLF in hospitals at all levels.
6.Association between Fish Consumption and Stroke Incidence Across Different Predicted Risk Populations: A Prospective Cohort Study from China.
Hong Yue HU ; Fang Chao LIU ; Ke Yong HUANG ; Chong SHEN ; Jian LIAO ; Jian Xin LI ; Chen Xi YUAN ; Ying LI ; Xue Li YANG ; Ji Chun CHEN ; Jie CAO ; Shu Feng CHEN ; Dong Sheng HU ; Jian Feng HUANG ; Xiang Feng LU ; Dong Feng GU
Biomedical and Environmental Sciences 2025;38(1):15-26
OBJECTIVE:
The relationship between fish consumption and stroke is inconsistent, and it is uncertain whether this association varies across predicted stroke risks.
METHODS:
A cohort study comprising 95,800 participants from the Prediction for Atherosclerotic Cardiovascular Disease Risk in China project was conducted. A standardized questionnaire was used to collect data on fish consumption. Participants were stratified into low- and moderate-to-high-risk categories based on their 10-year stroke risk prediction scores. Hazard ratios ( HRs) and 95% confidence intervals ( CIs) were estimated using Cox proportional hazard models and additive interaction by relative excess risk due to interaction (RERI), attributable proportion (AP), and synergy index (SI).
RESULTS:
During 703,869 person-years of follow-up, 2,773 incident stroke events were identified. Higher fish consumption was associated with a lower risk of stroke, particularly among moderate-to-high-risk individuals ( HR = 0.53, 95% CI: 0.47-0.60) than among low-risk individuals ( HR = 0.64, 95% CI: 0.49-0.85). A significant additive interaction between fish consumption and predicted stroke risk was observed (RERI = 4.08, 95% CI: 2.80-5.36; SI = 1.64, 95% CI: 1.42-1.89; AP = 0.36, 95% CI: 0.28-0.43).
CONCLUSION
Higher fish consumption was associated with a lower risk of stroke, and this beneficial association was more pronounced in individuals with moderate-to-high stroke risk.
Humans
;
China/epidemiology*
;
Male
;
Female
;
Stroke/etiology*
;
Middle Aged
;
Prospective Studies
;
Incidence
;
Aged
;
Animals
;
Fishes
;
Risk Factors
;
Diet
;
Seafood
;
Adult
;
Cohort Studies
7.Association of Loneliness and Social Isolation with Ischemic Heart Disease: A Bidirectional and Network Mendelian Randomization Study.
Shu Yao SU ; Wan Yue WANG ; Chen Xi YUAN ; Zhen Nan LIN ; Xiang Feng LU ; Fang Chao LIU
Biomedical and Environmental Sciences 2025;38(3):351-364
OBJECTIVE:
Observational studies have shown inconsistent associations of loneliness or social isolation (SI) with ischemic heart disease (IHD), with unknown mediators.
METHODS:
Using data from genome-wide association studies of predominantly European ancestry, we performed a bidirectional two-sample Mendelian Randomization (MR) study to estimate causal effects of loneliness ( N = 487,647) and SI traits on IHD ( N = 184,305). SI traits included whether individuals lived alone, participated in various types of social activities, and how often they had contact with friends or family ( N = 459,830 to 461,369). A network MR study was conducted to evaluate the mediating roles of 20 candidate mediators, including metabolic, behavioral and psychological factors.
RESULTS:
Loneliness increased IHD risk ( OR= 2.129; 95% confidence interval [ CI]: 1.380 to 3.285), mediated by body fat percentage, waist-hip ratio, total cholesterol, and low-density lipoprotein cholesterol. For SI traits, only fewer social activities increased IHD risk ( OR= 1.815; 95% CI: 1.189 to 2.772), mediated by hypertension, high-density lipoprotein cholesterol, triglycerides, fasting insulin, and smoking cessation. No reverse causality of IHD with loneliness and SI was found.
CONCLUSION
These findings suggested more attention should be paid to individuals who feel lonely and have fewer social activities to prevent IHD, with several mediators as prioritized targets for intervention.
Loneliness/psychology*
;
Humans
;
Mendelian Randomization Analysis
;
Social Isolation
;
Myocardial Ischemia/etiology*
;
Male
;
Female
;
Middle Aged
;
Genome-Wide Association Study
;
Risk Factors
;
Aged
9.Thermal Ablation of Pulmonary Nodules by Electromagnetic Navigation Bronchoscopy Combined With Real-Time CT-Based 3D Fusion Navigation:Report of One Case.
Yuan XU ; Qun LIU ; Chao GUO ; Yi-Bo WANG ; Xiao-Fang WU ; Chen-Xi MA ; Gui-Ge WANG ; Qian-Shu LIU ; Nai-Xin LIANG ; Shan-Qing LI
Acta Academiae Medicinae Sinicae 2025;47(1):137-141
A nodule in the right middle lobe of the lung was treated by a combination of cone-beam CT,three-dimensional registration for fusion imaging,and electromagnetic navigation bronchoscopy-guided thermal ablation.The procedure lasted for 90 min,with no significant bleeding observed under the bronchoscope.The total radiation dose during the operation was 384 mGy.The patient recovered well postoperatively,with only a small amount of blood in the sputum and no pneumothorax or other complications.A follow-up chest CT on the first day post operation showed that the ablation area completely covered the lesion,and the patient was discharged successfully.
Humans
;
Bronchoscopy/methods*
;
Catheter Ablation/methods*
;
Cone-Beam Computed Tomography
;
Electromagnetic Phenomena
;
Imaging, Three-Dimensional
;
Lung Neoplasms/diagnostic imaging*
;
Tomography, X-Ray Computed
10.Preliminary application of human-computer interaction CT imaging AI recognition and positioning technology in the treatment of type C1 distal radius fractures.
Yong-Zhong CHENG ; Xiao-Dong YIN ; Fei LIU ; Xin-Heng DENG ; Chao-Lu WANG ; Shu-Ke CUI ; Yong-Yao LI ; Wei YAN
China Journal of Orthopaedics and Traumatology 2025;38(1):31-40
OBJECTIVE:
To explore the accuracy of human-computer interaction software in identifying and locating type C1 distal radius fractures.
METHODS:
Based on relevant inclusion and exclusion criteria, 14 cases of type C1 distal radius fractures between September 2023 and March 2024 were retrospectively analyzed, comprising 3 males and 11 females(aged from 27 to 82 years). The data were assigned randomized identifiers. A senior orthopedic physician reviewed the films and measured the ulnar deviation angle, radial height, palmar inclination angle, intra-articular step, and intra-articular gap for each case on the hospital's imaging system. Based on the reduction standard for distal radius fractures, cases were divided into reduction group and non-reduction group. Then, the data were sequentially imported into a human-computer interaction intelligent software, where a junior orthopedic physician analyzed the same radiological parameters, categorized cases, and measured fracture details. The categorization results from the software were consistent with manual classifications (6 reduction cases and 8 non-reduction cases). For non-reduction cases, the software performed further analyses, including bone segmentation and fracture recognition, generating 8 diagnostic reports containing fracture recognition information. For the 6 reduction cases, the senior and junior orthopedic physicians independently analyzed the data on the hospital's imaging system and the AI software, respectively. Bone segments requiring reduction were identified, verified by two senior physicians, and measured for displacement and rotation along the X (inward and outward), Z (front and back), and Y (up and down) axes. The AI software generated comprehensive diagnostic reports for these cases, which included all measurements and fracture recognition details.
RESULTS:
Both the manual and AI software methods consistently categorized the 14 cases into 6 reduction and 8 non-reduction groups, with identical data distributions. A paired sample t-test revealed no statistically significant differences (P>0.05) between the manual and software-based measurements for ulnar deviation angle, radial ulnar bone height, palmar inclination angle, intra-articular step, and joint space. In fracture recognition, the AI software correctly identified 10 C-type fractures and 4 B-type fractures. For the 6 reduction cases, a total of 24 bone fragments were analyzed across both methods. After verification, it was found that the bone fragments identified by the two methods were consistent. A paired sample t-tests revealed that the identified bone fragments and measured displacement and rotation angles along the X, Y, and Z axes were consistent between the two methods. No statistically significant differences(P>0.05) were found between manual and software measurements for these parameters.
CONCLUSION
Human-computer interaction software employing AI technology demonstrated comparable accuracy to manual measurement in identifying and locating type C1 distal radius fractures on CT imaging.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
Middle Aged
;
Adult
;
Aged
;
Aged, 80 and over
;
Tomography, X-Ray Computed/methods*
;
Retrospective Studies
;
Software
;
Wrist Fractures

Result Analysis
Print
Save
E-mail