1.Association of Longitudinal Change in Fasting Blood Glucose with Risk of Cerebral Infarction in a Patients with Diabetes.
Tai Yang LUO ; Xuan DENG ; Xue Yu CHEN ; Yu He LIU ; Shuo Hua CHEN ; Hao Ran SUN ; Zi Wei YIN ; Shou Ling WU ; Yong ZHOU ; Xing Dong ZHENG
Biomedical and Environmental Sciences 2025;38(8):926-934
OBJECTIVE:
To investigate the association between long-term glycemic control and cerebral infarction risk in patients with diabetes through a large-scale cohort study.
METHODS:
This prospective, community-based cohort study included 12,054 patients with diabetes. From 2006 to 2012, 38,272 fasting blood glucose (FBG) measurements were obtained from these participants. FBG trajectory patterns were generated using latent mixture modelling. Cox proportional hazards models were applied to assess the subsequent risk of cerebral infarction associated with different FBG trajectory patterns.
RESULTS:
At baseline, the mean age of the participants was 55.2 years. Four distinct FBG trajectories were identified based on FBG concentrations and their changes over the 6-year follow-up period. After a median follow-up of 6.9 years, 786 cerebral infarction events were recorded. Different trajectory patterns were associated with significantly varied outcome risks (Log-Rank P < 0.001). Compared with the low-stability group, Hazard Ratio ( HR) adjusted for potential confounders were 1.37 for the moderate-increasing group, 1.23 for the elevated-decreasing group, and 2.08 for the elevated-stable group.
CONCLUSION
Sustained high FBG levels were found to play a critical role in the development of ischemic stroke among patients with diabetes. Controlling FBG levels may reduce the risk of cerebral infarction.
Humans
;
Cerebral Infarction/blood*
;
Middle Aged
;
Male
;
Female
;
Blood Glucose/analysis*
;
Fasting/blood*
;
Aged
;
Prospective Studies
;
Risk Factors
;
Diabetes Mellitus/blood*
;
Adult
;
Proportional Hazards Models
2.The clinical significance of lateral pelvic sentinel lymph node biopsy using indocyanine green fluorescence navigation in laparoscopic lateral pelvic lymph node dissection
Hao SU ; Zheng XU ; Mandula BAO ; Shou LUO ; Jianwei LIANG ; Wei PEI ; Xu GUAN ; Zheng LIU ; Zheng JIANG ; Mingguang ZHANG ; Zhixun ZHAO ; Weisen JIN ; Haitao ZHOU
Chinese Journal of Oncology 2024;46(2):140-145
Objectives:This study aims to explore the clinical significance of lateral pelvic sentinel lymph node biopsy (SLNB) using indocyanine green (ICG) fluorescence navigation in laparoscopic lateral pelvic lymph node dissection (LLND) and evaluate the accuracy and feasibility of this technique to predict the status of lateral pelvic lymph nodes (LPLNs).Methods:The clinical and pathological characteristics, surgical outcomes, lymph node findings and perioperative complications of 16 rectal cancer patients who underwent SLNB using ICG fluorescence navigation in laparoscopic LLND in the Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College during April 2017 and October 2022 were retrospectively collected and analyzed. The patients did not receive preoperative neoadjuvant radiotherapy and presented with LPLNs but without LPLN enlargement (MRI showed the maximum short axes of the LPLNs were ≥5 mm and <10 mm at first visit).Results:All 16 patients were successfully performed SLNB using ICG fluorescence navigation in laparoscopic LLND. Three patients underwent bilateral LLND and 13 patients underwent unilateral LLND. The lateral pelvic sentinel lymph nodes (SLNs) were clearly fluorescent before dissection in 14 patients and the detection rate of SLNs for these patients was 87.5%. Lateral pelvic SLN metastasis was diagnosed in 2 patients and negative results were found in 12 patients by frozen pathological examinations. Among the 14 patients in whom lateral pelvic SLNs were detected, the dissected lateral pelvic non-SLNs were all negative. All dissected LPLNs were negative in two patients without fluorescent lateral pelvic SLNs. The specificity, sensitivity, negative predictive value, and accuracy was 85.7%, 100%, 100%, and 100%, respectively.Conclusions:This study indicates that lateral pelvic SLNB using ICG fluorescence navigation shows promise as a safe and feasible procedure with good accuracy. This technique may replace preventive LLND for locally advanced lower rectal cancer.
3.The clinical significance of lateral pelvic sentinel lymph node biopsy using indocyanine green fluorescence navigation in laparoscopic lateral pelvic lymph node dissection
Hao SU ; Zheng XU ; Mandula BAO ; Shou LUO ; Jianwei LIANG ; Wei PEI ; Xu GUAN ; Zheng LIU ; Zheng JIANG ; Mingguang ZHANG ; Zhixun ZHAO ; Weisen JIN ; Haitao ZHOU
Chinese Journal of Oncology 2024;46(2):140-145
Objectives:This study aims to explore the clinical significance of lateral pelvic sentinel lymph node biopsy (SLNB) using indocyanine green (ICG) fluorescence navigation in laparoscopic lateral pelvic lymph node dissection (LLND) and evaluate the accuracy and feasibility of this technique to predict the status of lateral pelvic lymph nodes (LPLNs).Methods:The clinical and pathological characteristics, surgical outcomes, lymph node findings and perioperative complications of 16 rectal cancer patients who underwent SLNB using ICG fluorescence navigation in laparoscopic LLND in the Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College during April 2017 and October 2022 were retrospectively collected and analyzed. The patients did not receive preoperative neoadjuvant radiotherapy and presented with LPLNs but without LPLN enlargement (MRI showed the maximum short axes of the LPLNs were ≥5 mm and <10 mm at first visit).Results:All 16 patients were successfully performed SLNB using ICG fluorescence navigation in laparoscopic LLND. Three patients underwent bilateral LLND and 13 patients underwent unilateral LLND. The lateral pelvic sentinel lymph nodes (SLNs) were clearly fluorescent before dissection in 14 patients and the detection rate of SLNs for these patients was 87.5%. Lateral pelvic SLN metastasis was diagnosed in 2 patients and negative results were found in 12 patients by frozen pathological examinations. Among the 14 patients in whom lateral pelvic SLNs were detected, the dissected lateral pelvic non-SLNs were all negative. All dissected LPLNs were negative in two patients without fluorescent lateral pelvic SLNs. The specificity, sensitivity, negative predictive value, and accuracy was 85.7%, 100%, 100%, and 100%, respectively.Conclusions:This study indicates that lateral pelvic SLNB using ICG fluorescence navigation shows promise as a safe and feasible procedure with good accuracy. This technique may replace preventive LLND for locally advanced lower rectal cancer.
4.Cynaroside regulates the AMPK/SIRT3/Nrf2 pathway to inhibit doxorubicin-induced cardiomyocyte pyroptosis
ZOU HAI ; ZHANG MENGYU ; YANG XUE ; SHOU HUAFENG ; CHEN ZHENGLIN ; ZHU QUANFENG ; LUO TING ; MOU XIAOZHOU ; CHEN XIAOYI
Journal of Zhejiang University. Science. B 2024;25(9):756-772
Doxorubicin(DOX)is a commonly administered chemotherapy drug for treating hematological malignancies and solid tumors;however,its clinical application is limited by significant cardiotoxicity.Cynaroside(Cyn)is a flavonoid glycoside distributed in honeysuckle,with confirmed potential biological functions in regulating inflammation,pyroptosis,and oxidative stress.Herein,the effects of Cyn were evaluated in a DOX-induced cardiotoxicity(DIC)mouse model,which was established by intraperitoneal injections of DOX(5 mg/kg)once a week for three weeks.The mice in the treatment group received dexrazoxane,MCC950,and Cyn every two days.Blood biochemistry,histopathology,immunohistochemistry,reverse transcription-quantitative polymerase chain reaction(RT-qPCR),and western blotting were conducted to investigate the cardioprotective effects and potential mechanisms of Cyn treatment.The results demonstrated the significant benefits of Cyn treatment in mitigating DIC;it could effectively alleviate oxidative stress to a certain extent,maintain the equilibrium of cell apoptosis,and enhance the cardiac function of mice.These effects were realized via regulating the transcription levels of pyroptosis-related genes,such as nucleotide-binding oligomerization domain-like receptor protein 3(NLRP3),caspase-1,and gasdermin D(GSDMD).Mechanistically,for DOX-induced myocardial injury,Cyn could significantly modulate the expression of pivotal genes,including adenosine monophosphate-activated protein kinase(AMPK),peroxisome proliferator-activated receptor γ coactivator-1α(PGC-1α),sirtuin 3(SIRT3),and nuclear factor erythroid 2-related factor 2(Nrf2).We attribute it to the mediation of AMPK/SIRT3/Nrf2 pathway,which plays a central role in preventing DOX-induced cardiomyocyte injury.In conclusion,the present study confirms the therapeutic potential of Cyn in DIC by regulating the AMPK/SIRT3/Nrf2 pathway.
5.Current applications of transcatheter edge-to-edge tricuspid valve repair
Chun-Mei XIE ; Meng-Qi SHEN ; Da ZHU ; Shou-Zheng WANG ; Zhi-Ling LUO ; Xiang-Bin PAN
Chinese Journal of Interventional Cardiology 2024;32(1):45-50
Tricuspid regurgitation(TR)is a common heart valve disease.According to the pathogenesis,TR can be divided into primary(organic)and secondary(functional)regurgitation,of which functional TR accounts for more than 90%.Patients with severe TR have poor prognosis and poor drug treatment,and surgery(valvuloplasty)is the main treatment.At present,transcatheter edge-to-edge tricuspid valve repair(T-TEER)has become an essential program of transcatheter treatment for TR,providing minimally invasive treatment for TR patients who cannot undergo surgery or are at high risk of surgery.T-TEER reduces the degree of regurgitation by clamping leaflets,and is currently in the early stage of research and development exploration and clinical validation,mainly for functional TR.T-TEER devices have also made significant progress(TriClip,PASCAL),and Chinese-made novel-designed T-TEER devices are also undergoing clinical trials(DragonFly-TTM,SQ-Kyrin-TTM,NeoBlazarTM).This paper reviews the current applications and research progress of T-TEER.
6.Long-term hypomethylating agents in patients with myelodysplastic syndromes: a multi-center retrospective study
Xiaozhen LIU ; Shujuan ZHOU ; Jian HUANG ; Caifang ZHAO ; Lingxu JIANG ; Yudi ZHANG ; Chen MEI ; Liya MA ; Xinping ZHOU ; Yanping SHAO ; Gongqiang WU ; Xibin XIAO ; Rongxin YAO ; Xiaohong DU ; Tonglin HU ; Shenxian QIAN ; Yuan LI ; Xuefen YAN ; Li HUANG ; Manling WANG ; Jiaping FU ; Lihong SHOU ; Wenhua JIANG ; Weimei JIN ; Linjie LI ; Jing LE ; Wenji LUO ; Yun ZHANG ; Xiujie ZHOU ; Hao ZHANG ; Xianghua LANG ; Mei ZHOU ; Jie JIN ; Huifang JIANG ; Jin ZHANG ; Guifang OUYANG ; Hongyan TONG
Chinese Journal of Hematology 2024;45(8):738-747
Objective:To evaluate the efficacy and safety of hypomethylating agents (HMA) in patients with myelodysplastic syndromes (MDS) .Methods:A total of 409 MDS patients from 45 hospitals in Zhejiang province who received at least four consecutive cycles of HMA monotherapy as initial therapy were enrolled to evaluate the efficacy and safety of HMA. Mann-Whitney U or Chi-square tests were used to compare the differences in the clinical data. Logistic regression and Cox regression were used to analyze the factors affecting efficacy and survival. Kaplan-Meier was used for survival analysis. Results:Patients received HMA treatment for a median of 6 cycles (range, 4-25 cycles) . The complete remission (CR) rate was 33.98% and the overall response rate (ORR) was 77.02%. Multivariate analysis revealed that complex karyotype ( P=0.02, OR=0.39, 95% CI 0.18-0.84) was an independent favorable factor for CR rate. TP53 mutation ( P=0.02, OR=0.22, 95% CI 0.06-0.77) was a predictive factor for a higher ORR. The median OS for the HMA-treated patients was 25.67 (95% CI 21.14-30.19) months. HMA response ( P=0.036, HR=0.47, 95% CI 0.23-0.95) was an independent favorable prognostic factor, whereas complex karyotype ( P=0.024, HR=2.14, 95% CI 1.10-4.15) , leukemia transformation ( P<0.001, HR=2.839, 95% CI 1.64-4.92) , and TP53 mutation ( P=0.012, HR=2.19, 95% CI 1.19-4.07) were independent adverse prognostic factors. There was no significant difference in efficacy and survival between the reduced and standard doses of HMA. The CR rate and ORR of MDS patients treated with decitabine and azacitidine were not significantly different. The median OS of patients treated with decitabine was longer compared with that of patients treated with azacitidine (29.53 months vs 20.17 months, P=0.007) . The incidence of bone marrow suppression and pneumonia in the decitabine group was higher compared with that in the azacitidine group. Conclusion:Continuous and regular use of appropriate doses of hypomethylating agents may benefit MDS patients to the greatest extent if it is tolerated.
7.Application of Laparoscopic Surgery in Ileostomy Reversal
Zheng XU ; Shou LUO ; Hao SU ; Mandula BAO ; Xu GUAN ; Mingguang ZHANG ; Jianwei LIANG ; Haitao ZHOU
Cancer Research on Prevention and Treatment 2023;50(4):334-337
In colorectal cancer surgery, loop ileostomy is sometimes necessary to prevent anastomotic leakage. Although ileostomy reversal is relatively simple, postoperative complication is inevitable. In recent years, laparoscopic surgery has been gradually applied in ileostomy reversal due to its small trauma, fast recovery, and low complications, exhibiting satisfactory short-term outcomes. This review analyzes the application of the laparoscopic technique in ileostomy surgery and explores the potential of total laparoscopic surgery, aiming to provide a new perspective for the clinical application of laparoscopic ileostomy reversal.
8.Preliminary report on the use of total lumpectomyconical remnant gastric - esophagus side overlap anastomosis in radical resection of Siewert type II proximal gastric cancer
Liming WANG ; Haoyue MA ; Peng SUN ; Shou LUO ; Yusong LUAN ; Peide REN ; Xuhao CAI ; Huijing CHANG ; Panxin PENG ; Yonggang YU ; Yangyang WANG ; Bolun SONG ; Weiguo XU ; Yinggang CHEN
Chinese Journal of Gastrointestinal Surgery 2023;26(9):885-888
Objective:There is no standard method for esophageal remnant gastric reconstruction for proximal gastrectomy. Reflux esophagitis caused by esophagogastrostomy remains a difficult surgical problem. To report the preliminary surgical results of novel esophagus-conical remnant gastric side overlap anastomosis (CGEO) , with particular emphasis on postoperative esophageal reflux.Methods:In June 2022, we developed a novel CGEO for laparoscopic proximal gastrectomy on two patients with Siewert type II esophagogastric junction adenocarcinoma. Surgical procedures for CGEO: (1) Laparoscopic proximal gastrectomy and preparation of conically shaped gastric remnant; (2) Determining anastomotic site of residual stomach and esophagus; (3) Side-to-side anastomosis of right esophageal wall to anterior of conical gastric remnant; (4) Valvuloplasty of esophageal stump.Results:Case 1 was a 71-year-old man with an operation time of 305 minutes and was successfully discharged from the hospital on the 9th day after surgery, and the postoperative pathology was T3N0M0. Case 2 was an 82-year-old man with an operation time of 325 minutes. He was discharged on the 10th day after surgery. In both cases, only mild esophageal mucosal changes were seen in gastroscopy, there were no obvious symptoms of esophageal reflux. There was also no significant weight change at half a year after operation.Conclusion:CGEO is moderately safe in radical surgery for proximal gastric cancer, and may have a preventive effect on the occurrence of postoperative esophageal reflux, but long-term results need to be confirmed by further studies with follow-up.
9.Preliminary report on the use of total lumpectomyconical remnant gastric - esophagus side overlap anastomosis in radical resection of Siewert type II proximal gastric cancer
Liming WANG ; Haoyue MA ; Peng SUN ; Shou LUO ; Yusong LUAN ; Peide REN ; Xuhao CAI ; Huijing CHANG ; Panxin PENG ; Yonggang YU ; Yangyang WANG ; Bolun SONG ; Weiguo XU ; Yinggang CHEN
Chinese Journal of Gastrointestinal Surgery 2023;26(9):885-888
Objective:There is no standard method for esophageal remnant gastric reconstruction for proximal gastrectomy. Reflux esophagitis caused by esophagogastrostomy remains a difficult surgical problem. To report the preliminary surgical results of novel esophagus-conical remnant gastric side overlap anastomosis (CGEO) , with particular emphasis on postoperative esophageal reflux.Methods:In June 2022, we developed a novel CGEO for laparoscopic proximal gastrectomy on two patients with Siewert type II esophagogastric junction adenocarcinoma. Surgical procedures for CGEO: (1) Laparoscopic proximal gastrectomy and preparation of conically shaped gastric remnant; (2) Determining anastomotic site of residual stomach and esophagus; (3) Side-to-side anastomosis of right esophageal wall to anterior of conical gastric remnant; (4) Valvuloplasty of esophageal stump.Results:Case 1 was a 71-year-old man with an operation time of 305 minutes and was successfully discharged from the hospital on the 9th day after surgery, and the postoperative pathology was T3N0M0. Case 2 was an 82-year-old man with an operation time of 325 minutes. He was discharged on the 10th day after surgery. In both cases, only mild esophageal mucosal changes were seen in gastroscopy, there were no obvious symptoms of esophageal reflux. There was also no significant weight change at half a year after operation.Conclusion:CGEO is moderately safe in radical surgery for proximal gastric cancer, and may have a preventive effect on the occurrence of postoperative esophageal reflux, but long-term results need to be confirmed by further studies with follow-up.
10.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve

Result Analysis
Print
Save
E-mail