1.Application of 3D printed titanium cage cutting model in anterior cervical vertebrae subtotal decompression and bone graft fusion
Yingao JIA ; Shitao GAO ; Fei WANG
Chinese Journal of Tissue Engineering Research 2026;30(3):604-611
BACKGROUND:As a mainstream surgical technique for the treatment of cervical spondylotic myelopathy through the anterior cervical subtotal decompression and bone graft fusion,it has many advantages.However,due to the high risk of this surgery and the particularity of the cervical anatomy,it is also a challenge for the surgeon.The gradual maturity of 3D printing technology and the continuous development of applications in the medical field are now able to provide more perfect personalized treatment.OBJECTIVE:To investigate the efficacy of 3D printed titanium cage cutting model in anterior cervical vertebrae subtotal decompression and bone graft fusion.METHODS:Medical records of 57 patients undergoing anterior cervical corpectomy decompression and fusion surgery admitted to the Department of Spine Surgery of Affiliated Hospital of Yan'an University from April 2021 to April 2023 were retrospectively analyzed.According to whether the 3D printed titanium cage cutting model was used in the operation,the patients were divided into the traditional titanium cage bone grafting group(control group,n=30)and the 3D printed titanium cage model group(observation group,n=27).The general data,amount of blood loss during operation,number ofC-arm X-ray machine fluoroscopy during operation,operation time,as well as anterior intervertebral edge height(H1),posterior intervertebral edge height(H2)and C2-C7 Cobb angle of the two groups measured on the cervical lateral X-ray films before,3 days and 6 months after operation were recorded and analyzed.The settling degree of the titanium cage was assessed with the distance of the height of the anterior and posterior edges of the vertebral body at 3 days and 6 months after surgery.Visual analog scale was used to evaluate neck pain and Japanese Orthopaedic Association was used to evaluate nerve function.RESULTS AND CONCLUSION:(1)Follow-up was conducted for at least 6 months.(2)The amount of intraoperative blood loss and fluoroscopy times in the observation group were less than those in the control group(P<0.05).The operative time of the observation group was significantly shorter than that of the control group(P<0.05).(3)There were no significant differences in C2-C7 Cobb angle,visual analog scale score,Japanese Orthopaedic Association score,anterior vertebral border height(H1)and posterior vertebral border height(H2)before surgery,3 days and 6 months after surgery between the two groups(P>0.05).(4)There were five patients in the observation group(with severe subsidence rate of 19%)with severe subsidence at the anterior and posterior edges of the surgical segment,and seven patients in the control group(with severe subsidence rate of 23%)with severe subsidence(H1 or H2 subsidence≥3 mm)at the surgical segment 6 months after surgery.There was no significant difference in the rate of severe subsidence of titanium cage between the two groups(P>0.05).(5)At the last follow-up,bone fusion was achieved at the operative level in both groups,and there was no statistical significance in bone graft fusion rate between the two groups(P>0.05).(6)The results showed that the application of 3D printed titanium cage cutting model in anterior cervical corpectomy decompression and fusion surgery had the same clinical effect as that of traditional surgery,but the former could effectively reduce the fluoroscopy times of C-arm X-ray machine,the amount of blood loss and the operation time,and had unique advantages in the pruning and implantation of titanium cage during surgery.
2.Application of 3D printed titanium cage cutting model in anterior cervical vertebrae subtotal decompression and bone graft fusion
Yingao JIA ; Shitao GAO ; Fei WANG
Chinese Journal of Tissue Engineering Research 2026;30(3):604-611
BACKGROUND:As a mainstream surgical technique for the treatment of cervical spondylotic myelopathy through the anterior cervical subtotal decompression and bone graft fusion,it has many advantages.However,due to the high risk of this surgery and the particularity of the cervical anatomy,it is also a challenge for the surgeon.The gradual maturity of 3D printing technology and the continuous development of applications in the medical field are now able to provide more perfect personalized treatment.OBJECTIVE:To investigate the efficacy of 3D printed titanium cage cutting model in anterior cervical vertebrae subtotal decompression and bone graft fusion.METHODS:Medical records of 57 patients undergoing anterior cervical corpectomy decompression and fusion surgery admitted to the Department of Spine Surgery of Affiliated Hospital of Yan'an University from April 2021 to April 2023 were retrospectively analyzed.According to whether the 3D printed titanium cage cutting model was used in the operation,the patients were divided into the traditional titanium cage bone grafting group(control group,n=30)and the 3D printed titanium cage model group(observation group,n=27).The general data,amount of blood loss during operation,number ofC-arm X-ray machine fluoroscopy during operation,operation time,as well as anterior intervertebral edge height(H1),posterior intervertebral edge height(H2)and C2-C7 Cobb angle of the two groups measured on the cervical lateral X-ray films before,3 days and 6 months after operation were recorded and analyzed.The settling degree of the titanium cage was assessed with the distance of the height of the anterior and posterior edges of the vertebral body at 3 days and 6 months after surgery.Visual analog scale was used to evaluate neck pain and Japanese Orthopaedic Association was used to evaluate nerve function.RESULTS AND CONCLUSION:(1)Follow-up was conducted for at least 6 months.(2)The amount of intraoperative blood loss and fluoroscopy times in the observation group were less than those in the control group(P<0.05).The operative time of the observation group was significantly shorter than that of the control group(P<0.05).(3)There were no significant differences in C2-C7 Cobb angle,visual analog scale score,Japanese Orthopaedic Association score,anterior vertebral border height(H1)and posterior vertebral border height(H2)before surgery,3 days and 6 months after surgery between the two groups(P>0.05).(4)There were five patients in the observation group(with severe subsidence rate of 19%)with severe subsidence at the anterior and posterior edges of the surgical segment,and seven patients in the control group(with severe subsidence rate of 23%)with severe subsidence(H1 or H2 subsidence≥3 mm)at the surgical segment 6 months after surgery.There was no significant difference in the rate of severe subsidence of titanium cage between the two groups(P>0.05).(5)At the last follow-up,bone fusion was achieved at the operative level in both groups,and there was no statistical significance in bone graft fusion rate between the two groups(P>0.05).(6)The results showed that the application of 3D printed titanium cage cutting model in anterior cervical corpectomy decompression and fusion surgery had the same clinical effect as that of traditional surgery,but the former could effectively reduce the fluoroscopy times of C-arm X-ray machine,the amount of blood loss and the operation time,and had unique advantages in the pruning and implantation of titanium cage during surgery.
3.Relationship between anterior convex angle and fusion cage settlement after oblique lumbar interbody fusion combined with percutaneous pedicle screw fixation
Youzhi ZHOU ; Peng GAO ; Qingsen YUAN ; Ying TAN ; Shitao XU ; Guanglin CHEN ; Jinqiang WANG ; Liang ZHANG
Chinese Journal of Tissue Engineering Research 2025;29(15):3171-3178
BACKGROUND:With the continuous advancement of medical technology,the combination of oblique lumbar interbody fusion and percutaneous pedicle screw fixation has become a common method for treating lumbar degenerative diseases;however,there is still a lack of in-depth research on the relationship between changes in anterior convexity angles at different postoperative segments and fusion device settlement.OBJECTIVE:To explore the relationship between changes in anterior convexity angle of different segments and Cage subsidence after oblique lumbar interbody fusion combined with percutaneous pedicle screw fixation surgery.METHODS:Patients(93 cases)with lumbar degenerative diseases who underwent oblique lumbar interbody fusion combined with percutaneous pedicle screw fixation surgery in Weifang Hospital of Traditional Chinese Medicine from February 2019 to April 2023 were selected as the research subjects.According to the postoperative disc height loss value,they were divided into Cage subsidence group(25 cases,>2 mm)and non-Cage subsidence group(68 cases,<2 mm).Multiple Logistic regression analysis was used to analyze the risk factors for cage subsidence.Stepwise regression was utilized to evaluate the relationship of each risk factor and Cage subsidence.Risk prediction model was built and evaluated.RESULTS AND CONCLUSION:(1)After adjusting for confounding factors,there was still independent correlation between lumbar lordosis loss value and segmental lordosis improvement value and Cage subsidence risk(P<0.05).(2)Age,oswestry disability index,disc height improvement value,segmental lordosis improvement value,and lumbar lordosis loss value were all independent influencing factors for the occurrence of Cage subsidence(P<0.05).Among them,age,lumbar lordosis loss value,disc height improvement value,and segmental lordosis improvement value were most closely related to Cage subsidence.(3)The results of multivariate Logistic regression model analysis showed that when P=0.80,the Jordan index was the highest and the prediction effect was the best,with accuracy of 89.27%,sensitivity of 86.67%,and specificity of 89.89%.The model evaluation results showed that it had good discrimination and high accuracy.(4)As the lumbar lordosis loss value and segmental lordosis improvement value increase,the risk of Cage subsidence increases,which affects clinical efficacy.(5)It is indicated that age,lumbar lordosis loss value,disc height improvement value,and segmental lordosis improvement value are most closely related to Cage subsidence,and clinical doctors should pay more attention.
4.Relationship between anterior convex angle and fusion cage settlement after oblique lumbar interbody fusion combined with percutaneous pedicle screw fixation
Youzhi ZHOU ; Peng GAO ; Qingsen YUAN ; Ying TAN ; Shitao XU ; Guanglin CHEN ; Jinqiang WANG ; Liang ZHANG
Chinese Journal of Tissue Engineering Research 2025;29(15):3171-3178
BACKGROUND:With the continuous advancement of medical technology,the combination of oblique lumbar interbody fusion and percutaneous pedicle screw fixation has become a common method for treating lumbar degenerative diseases;however,there is still a lack of in-depth research on the relationship between changes in anterior convexity angles at different postoperative segments and fusion device settlement.OBJECTIVE:To explore the relationship between changes in anterior convexity angle of different segments and Cage subsidence after oblique lumbar interbody fusion combined with percutaneous pedicle screw fixation surgery.METHODS:Patients(93 cases)with lumbar degenerative diseases who underwent oblique lumbar interbody fusion combined with percutaneous pedicle screw fixation surgery in Weifang Hospital of Traditional Chinese Medicine from February 2019 to April 2023 were selected as the research subjects.According to the postoperative disc height loss value,they were divided into Cage subsidence group(25 cases,>2 mm)and non-Cage subsidence group(68 cases,<2 mm).Multiple Logistic regression analysis was used to analyze the risk factors for cage subsidence.Stepwise regression was utilized to evaluate the relationship of each risk factor and Cage subsidence.Risk prediction model was built and evaluated.RESULTS AND CONCLUSION:(1)After adjusting for confounding factors,there was still independent correlation between lumbar lordosis loss value and segmental lordosis improvement value and Cage subsidence risk(P<0.05).(2)Age,oswestry disability index,disc height improvement value,segmental lordosis improvement value,and lumbar lordosis loss value were all independent influencing factors for the occurrence of Cage subsidence(P<0.05).Among them,age,lumbar lordosis loss value,disc height improvement value,and segmental lordosis improvement value were most closely related to Cage subsidence.(3)The results of multivariate Logistic regression model analysis showed that when P=0.80,the Jordan index was the highest and the prediction effect was the best,with accuracy of 89.27%,sensitivity of 86.67%,and specificity of 89.89%.The model evaluation results showed that it had good discrimination and high accuracy.(4)As the lumbar lordosis loss value and segmental lordosis improvement value increase,the risk of Cage subsidence increases,which affects clinical efficacy.(5)It is indicated that age,lumbar lordosis loss value,disc height improvement value,and segmental lordosis improvement value are most closely related to Cage subsidence,and clinical doctors should pay more attention.

Result Analysis
Print
Save
E-mail