1.Stent-graft implantation for late postpancreatectomy hemorrhage after pancreatoduodenectomy.
Xiaoye LI ; Shibo XIA ; Liangxi YUAN ; Lei ZHANG ; Chao SONG ; Xiaolong WEI ; Qingsheng LU
Chinese Journal of Traumatology 2025;28(1):7-12
PURPOSE:
Postpancreatectomy hemorrhage (PPH) is a life-threatening complication after pancreatoduodenectomy. Stent-graft implantation is an emerging treatment option for PPH. This study reports the outcome of PPH treated with stent-graft implantation.
METHODS:
This was a single-center, retrospective study. Between April 2020 and December 2023, 1723 pancreatectomy cases were collected while we screened 12 cases of PPH after pancreatoduodenectomy treated with stent-graft implantation. Patients' medical and radiologic images were retrospectively reviewed. Technical and clinical success, complications, and stent-graft patency were evaluated. Continuous data are reported as means ± standard deviation when normally distributed or as median (Q1, Q3) when the data is non-normal distributed. Categorical data are reported as n (%). A p < 0.05 was considered statistically significant. Kaplan-Meier estimates were used for stent patency and patients' survival.
RESULTS:
Pancreatic fistula was identified in 6 cases (50.0%), and pseudoaneurysm was identified in 3 cases (25.0%), including pancreatic fistula together with pseudoaneurysm in 1 case (8.3%). All pseudoaneurysm or contrast extravasation sites were successfully excluded with patent distal perfusion, thus technical success was achieved in all cases. The overall survival rate at 6 months and 1 year was 91.7% and 78.6%, respectively. One patient had herniation of the small intestine into the thoracic cavity, which caused a broad thoracic and abdominal infection and died during hospitalization. Rebleeding occurred at the gastroduodenal artery stump in 1 case after stent-graft implantation for the splenic artery and was successfully treated with another stent-graft implantation. Two cases of asymptomatic stent-graft occlusion were observed at 24.6 and 26.3 after the operation, respectively.
CONCLUSIONS
With suitable anatomy, covered stent-graft implantation is an effective and safe treatment option for PPH with various bleeding sites and causes.
Humans
;
Pancreaticoduodenectomy/adverse effects*
;
Stents
;
Male
;
Retrospective Studies
;
Female
;
Middle Aged
;
Postoperative Hemorrhage/surgery*
;
Aged
;
Adult
2.YOLOX target detection model for automatically identifying endovascular interventional instruments on images of digital subtract angiography
Rui FENG ; Hao FENG ; Chao SONG ; Shibo XIA ; Qingsheng LU
Chinese Journal of Interventional Imaging and Therapy 2024;21(2):100-104
Objective To observe the value of a YOLOX target detection model for automatically identifying endovascular interventional instruments on images of digital subtract angiography(DSA).Methods DSA data of 37 patients who underwent abdominal endovascular interventional therapy were retrospectively analyzed.Totally 4 435 DSA images were captured and taken as data set,which were divided into training set(n=3 991)and verification set(n=444)at the ratio of 9∶1.Six kinds of endovascular interventional instruments were labeled.YOLOX algorithm was applied for deep learning of data in training set in order to build a target detection model,and the efficacy of the model for automatically identifying endovascular interventional instruments on DSA images was evaluated based on varification set.Results A total of 6 668 labels were put on 4 435 DSA images,aimed on Terumo 0.035in loach guide wire(n=587),Cook Lunderquist super hard guide wire(n=990),Optimed 5F with graduated pig tail catheter(n=1 680),Cordis MPA multi-functional catheter(n=667),Boston Scientific V-18 controllable guide wire(n=1 330)and Terumo 6F long sheath(n= 1 414),respectively.The training set contained 527,875,1 466,598,1 185 and 1 282,while the verification set contained 60,115,214,69,145 and 132 the above labels,respectively.The pixel accuracy of YOLOX target detection model for automatically identifying the above instruments in the verification set was 95.23%,97.32%,99.18%,98.97%,97.60%and 98.19%,respectively,with a mean pixel accuracy of 97.75%.Conclusion YOLOX target detection model could automatically identify endovascular interventional instruments on images of DSA.
3.Artificial intelligence knowledge graph and image classification for quality control of chest posterior-anterior position X-ray radiograph
Qian WANG ; Liangliang SONG ; Xiao HAN ; Ming LIU ; Biao ZHANG ; Shibo ZHAO ; Zongyun GU ; Lili HUANG ; Chuanfu LI ; Xiaohu LI ; Yongqiang YU
Chinese Journal of Medical Imaging Technology 2024;40(6):922-927
Objective To observe the value of artificial intelligence(AI)knowledge graph and image classification for quality control(QC)of chest posterior-anterior position X-ray radiograph(abbreviated as chest film).Methods Totally 9 236 chest films from 595 medical institutions in Anhui province imaging cloud platform were retrospectively enrolled.QC knowledge graph containing 21 classification labels were constructed.Firstly,QC of chest films based on the above knowledge graph were performed by 10 technicians for 2 rounds of single person and 1 round of multi person,and the results were recorded as A,B and C,respectively.Then AI algorithms were used to classify and evaluate based on knowledge graph,and the result was recorded as D.Finally,a QC expert reviewed results C and D to determine the final QC results and taken those as references to analyze the efficiency of the above 4 QC.Results The area under the curve(AUC)of AI algorithm for QC of chest films were all ≥0.780,with an average value of 0.939.The average precision of QC for chest films of A,B,C and D was 81.15%,85.47%,91.65%and 92.21%,respectively.Conclusion AI knowledge graph and image classification technology could be effectively used for QC of chest posterior-anterior position X-ray radiograph.
4.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
5.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
6.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
7.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
8.Prediction of Screw Loosening After Dynamic Pedicle Screw Fixation With Lumbar Polyetheretherketone Rods Using Magnetic Resonance Imaging-Based Vertebral Bone Quality Score
Guozheng JIANG ; Luchun XU ; Yukun MA ; Jianbin GUAN ; Yongdong YANG ; Wenqing ZHONG ; Wenhao LI ; Shibo ZHOU ; JiaWei SONG ; Ningning FENG ; Ziye QIU ; Zeyu LI ; YiShu ZHOU ; Letian MENG ; Yi QU ; Xing YU
Neurospine 2024;21(2):712-720
Objective:
To investigate the correlation between magnetic resonance imaging-based vertebral bone quality (VBQ) score and screw loosening after dynamic pedicle screw fixation with polyetheretherketone (PEEK) rods, and evaluate its predictive value.
Methods:
A retrospective analysis was conducted on the patients who underwent dynamic pedicle screw fixation with PEEK rods from March 2017 to June 2022. Data on age, sex, body mass index, hypertension, diabetes, hyperlipidemia history, long-term smoking, alcohol consumption, VBQ score, L1–4 average Hounsfield unit (HU) value, surgical fixation length, and the lowest instrumented vertebra were collected. Logistic regression analysis was employed to assess the relationship between VBQ score and pedicle screw loosening (PSL).
Results:
A total of 24 patients experienced PSL after surgery (20.5%). PSL group and non-PSL group showed statistical differences in age, number of fixed segments, fixation to the sacrum, L1–4 average HU value, and VBQ score (p < 0.05). The VBQ score in the PSL group was higher than that in the non-PSL group (3.56 ± 0.45 vs. 2.77 ± 0.31, p < 0.001). In logistic regression analysis, VBQ score (odds ratio, 3.425; 95% confidence interval, 1.552–8.279) were identified as independent risk factors for screw loosening. The area under the receiver operating characteristic curve for VBQ score predicting PSL was 0.819 (p < 0.05), with the optimal threshold of 3.15 (sensitivity, 83.1%; specificity, 80.5%).
Conclusion
The VBQ score can independently predict postoperative screw loosening in patients undergoing lumbar dynamic pedicle screw fixation with PEEK rods, and its predictive value is comparable to HU value.
9.Progress of endoscopic treatment for early-stage colorectal cancer and precancerous lesions
Cancer Research and Clinic 2023;35(3):228-233
With the continuous development of endoscopic technology, more and more early-stage colorectal cancer and precancerous lesions have been found by endoscopy, and endoscopic treatment has dominated the treatment of early-stage colorectal cancer for its characteristics of small trauma, rapid recovery and good effect. At present, there are many methods of endoscopic treatment, but their indications are still controversial, and some new technologies still need further verified. Based on the latest guidelines at home and abroad and some hot issues, this article reviews the progress of endoscopic treatment of early-stage colorectal cancer and precancerous lesions, mainly including the indications of various endoscopic treatment methods, some important technical improvement of endoscopic treatment methods, and the application of some new endoscopic treatment technologies, in order to provide some references for the minimally invasive treatment of early-stage colorectal cancer and precancerous lesions.
10.Comprehensive treatment of acute Stanford type A aortic dissection with limb malperfusion
Shibo SONG ; Lin LU ; Juxiang WANG ; Hua PENG ; Hui ZHUANG ; Xijie WU
Chinese Journal of Thoracic and Cardiovascular Surgery 2023;39(1):17-20
Objective:To explore different strategies of central repair first or malperfusion first to treat type A aortic dissection complicated with limb malperfusion.Methods:From January 2020 to December 2021, 302 patients were diagnosed with acute type A aortic dissection, and 17 consecutive patients were diagnosed as type A acute aortic dissection complicated with limb malperfusion and underwent Sun’s procedure. There were 16 males and 1 female with an average of(52.6±4.2)years. Surgical strategies were as follows: immediate central repair-Sun’s procedure in 14 patients, endovascular stenting followed by central repair in 3 patients, endovascular stenting after central repair in 1 patient.Results:The incidence rate of limb malperfusion of acute Stanford A aortic dissection was 5.6%(17/302). Average extracorporeal circulation time was(271.8±38.9)min, average aortic cross-clamp time was (186.3±31.8)min, and the average circulatory arrest time was (48.75±11.3)min. Early mortality rate was 17.6%(3/17). Two patients were left hospital voluntarily because of cerebral infarction. One patient underwent leg incision osteofascial compartment syndrome and discharged unevently. Five patients underwent continuous renal replacement therapy and hemoperfusion. Follow-up results showed that patients with serious limb malperfusion have symptoms of nerve dysfunction including amyosthenia and sensory disturbance, but recovered gradually with rehabilitation.Conclusion:Sun’s procedure is safe and feasible for type A acute aortic dissection complicated with mild limb malperfusion. For serious limb malperfusion, endovascular stent followed by Sun’s procedure is a good choice with CRRT and hemoperfusion.