1.The role of bile acid dynamics in inflammatory bowel disease and metabolic dysfunction-associated steatotic liver disease
Si-Rui Yu ; Run Sun ; Mei-Ya Shi ; Mei Yang ; Kun Chen ; Qiong Pan ; Ling Zhao ; Ming-Yue Wu ; Jin Chai
Liver Research 2026;10(1):35-50
The prevalence of metabolic dysfunction-associated steatotic liver disease (MASLD) is higher among individuals with inflammatory bowel disease (IBD) than in the general population. Emerging evidence indicates that the development of MASLD in patients with IBD may occur independently of traditional metabolic risk factors, suggesting a unique pathophysiological mechanism distinct from conventional MASLD pathways. Bile acids (BAs), which act as critical signaling molecules in enterohepatic circulation, play an essential role in maintaining gastrointestinal homeostasis through bidirectional gut–liver axis communication. These molecules are increasingly recognized as pivotal regulators in the progression of both MASLD and IBD. While previous studies have characterized the dynamics of BA in blood or fecal samples under both conditions, a comprehensive understanding of their metabolic profiles and the associated interactions within the gut–liver axis is still lacking. This review synthesizes current evidence from studies employing BA metabolomics to investigate IBD and MASLD. By focusing on BA signatures, we summarize conserved alterations between these two conditions and their potential mechanisms of disease progression. Our review advances understanding of BA-mediated pathways in IBD and MASLD, providing a foundation for assessing their roles in contributing to the pathogenesis of MASLD in patients with IBD.
2.Process Optimization and Health Risk Assessment of Calcined Haematitum Based on QbD Concept
Yue YANG ; Jingwei ZHOU ; Jialiang ZOU ; Guorong MEI ; Yifan SHI ; Lei ZHONG ; Jiaojiao WANG ; Xuelian GAN ; Dewen ZENG ; Xin CHEN ; Lin CHEN ; Hongping CHEN ; Shilin CHEN ; Yuan HU ; Youping LIU
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(13):187-196
ObjectiveTo investigate the processing technology of calcined Haematitum based on the concept of quality by design(QbD) and to assess its health risk. MethodsTaking whole iron content, Fe2+ dissolution content and looseness as critical quality attributes(CQAs), and calcination temperature, calcination time, spreading thickness and particle size as critical process parameters(CPPs) determined by the failure mode and effect analysis(FMEA), the processing technology of calcined Haematitum was optimized by orthogonal test combined with analytic hierarchy process-criteria importance through intercriteria correlation(AHP-CRITIC) hybrid weighting method. The contents of heavy metals and harmful elements were determined by inductively coupled plasma mass spectrometry, and the health risk assessment was carried out by daily exposure(EXP), target hazard quotient(THQ) and lifetime cancer risk(LCR), and the theoretical value of the maximum limit was deduced. ResultsThe optimal processing technology for calcined Haematitum was calcination at 650 ℃, calcination time of 1 h, particle size of 0.2-0.5 cm, spreading thickness of 1 cm, and vinegar quenching for 1 time[Haematitum-vinegar(10:3)]. The contents of 5 heavy metals and harmful elements in 13 batches of calcined Haematitum were all decreased with reductions of up to 5-fold. The cumulative THQ of 2 batches of samples was>1, while the cumulative THQ of all batches of Haematitum was>1. The LCR of As in 1 batches of Haematitum was 1×10-6-1×10-4, and the LCR of the rest was<1×10-6, and the LCRs of calcined Haematitum were all<1×10-6, indicating that the carcinogenic risk of calcined Haematitum was low, but special attention should still be paid to Haematitum medicinal materials. Preliminary theoretical values of the maximum limits of Cu, As, Cd, Pb and Hg were formulated as 1 014, 25, 17, 27, 7 mg·kg-1. ConclusionThe optimized processing technology of calcined Haematitum is stable and feasible, and the contents of heavy metals and harmful elements are reduced after processing. Preliminary theoretical values of the maximum limits of Cu, As, Cd, Pb and Hg are formulated to provide a scientific basis for the formulation of standards for the limits of harmful elements in Haematitum.
3.Process Optimization and Health Risk Assessment of Calcined Haematitum Based on QbD Concept
Yue YANG ; Jingwei ZHOU ; Jialiang ZOU ; Guorong MEI ; Yifan SHI ; Lei ZHONG ; Jiaojiao WANG ; Xuelian GAN ; Dewen ZENG ; Xin CHEN ; Lin CHEN ; Hongping CHEN ; Shilin CHEN ; Yuan HU ; Youping LIU
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(13):187-196
ObjectiveTo investigate the processing technology of calcined Haematitum based on the concept of quality by design(QbD) and to assess its health risk. MethodsTaking whole iron content, Fe2+ dissolution content and looseness as critical quality attributes(CQAs), and calcination temperature, calcination time, spreading thickness and particle size as critical process parameters(CPPs) determined by the failure mode and effect analysis(FMEA), the processing technology of calcined Haematitum was optimized by orthogonal test combined with analytic hierarchy process-criteria importance through intercriteria correlation(AHP-CRITIC) hybrid weighting method. The contents of heavy metals and harmful elements were determined by inductively coupled plasma mass spectrometry, and the health risk assessment was carried out by daily exposure(EXP), target hazard quotient(THQ) and lifetime cancer risk(LCR), and the theoretical value of the maximum limit was deduced. ResultsThe optimal processing technology for calcined Haematitum was calcination at 650 ℃, calcination time of 1 h, particle size of 0.2-0.5 cm, spreading thickness of 1 cm, and vinegar quenching for 1 time[Haematitum-vinegar(10:3)]. The contents of 5 heavy metals and harmful elements in 13 batches of calcined Haematitum were all decreased with reductions of up to 5-fold. The cumulative THQ of 2 batches of samples was>1, while the cumulative THQ of all batches of Haematitum was>1. The LCR of As in 1 batches of Haematitum was 1×10-6-1×10-4, and the LCR of the rest was<1×10-6, and the LCRs of calcined Haematitum were all<1×10-6, indicating that the carcinogenic risk of calcined Haematitum was low, but special attention should still be paid to Haematitum medicinal materials. Preliminary theoretical values of the maximum limits of Cu, As, Cd, Pb and Hg were formulated as 1 014, 25, 17, 27, 7 mg·kg-1. ConclusionThe optimized processing technology of calcined Haematitum is stable and feasible, and the contents of heavy metals and harmful elements are reduced after processing. Preliminary theoretical values of the maximum limits of Cu, As, Cd, Pb and Hg are formulated to provide a scientific basis for the formulation of standards for the limits of harmful elements in Haematitum.
4.Usefulness of intraoperative choledochoscopy in laparoscopic subtotal cholecystectomy for severe cholecystitis
Rui-Hui ZHANG ; Xiang-Nan WANG ; Yue-Feng MA ; Xue-Qian TANG ; Mei-Ju LIN ; Li-Jun SHI ; Jing-Yi LI ; Hong-Wei ZHANG
Annals of Hepato-Biliary-Pancreatic Surgery 2025;29(2):192-198
Laparoscopic subtotal cholecystectomy (LSC) has been a safe and viable alternative to conversion to laparotomy in cases of severe cholecystitis. The objective of this study is to determine the utility of intraoperative choledochoscopy in LSC for the exploration of the gallbladder, cyst duct, and subsequent stone clearance of the cystic duct in cases of severe cholecystitis. A total of 72 patients diagnosed with severe cholecystitis received choledochoscopy-assisted laparoscopic subtotal cholecystectomy (CALSC). A choledochoscopy was performed to explore the gallbladder cavity and/or cystic duct, and to extract stones using a range of techniques. The clinical records, including the operative records and outcomes, were subjected to analysis. No LSC was converted to open surgery, and no bile duct or vascular injuries were sustained. All stones within the cystic duct were removed by a combination of techniques, including high-frequency needle knife electrotomy, basket, and electrohydraulic lithotripsy. A follow-up examination revealed the absence of residual bile duct stones, with the exception of one common bile duct stone, which was extracted via endoscopic retrograde cholangiopancreatography. In certain special cases, CALSC may prove to be an efficacious treatment for the management of severe cholecystitis. This technique allows for optimal comprehension of the situation within the gallbladder cavity and cystic duct, facilitating the removal of stones from the cystic duct and reducing the residue of the non-functional gallbladder remnant.
5.Preparation and In Vitro Degradation Characteristics Analysis of Poly(lactic-co-glycolide)Microspheres Based on Microfluidic Process
Bao-Cheng WANG ; Cong-Yu MA ; Ke WANG ; Si-Tong ZHENG ; Xiao-Yan ZHANG ; Yue-Mei ZHAO ; Xun ZHAO ; Jian-Bin PAN ; Zheng-Song GAO ; Hai-Wei SHI ; Yao-Zuo YUAN ; Hong-Yuan CHEN
Chinese Journal of Analytical Chemistry 2025;53(4):621-630
Poly(lactic-co-glycolide)(PLGA)is a key excipient in long-acting sustained-release preparations,and its degradation properties directly affect the drug release behavior.In this study,PLGA microspheres were prepared by microfluidic techniques,and the morphology changes of the microspheres were observed by scanning electron microscopy(SEM).In alkaline environment,due to the accelerated hydrolysis of ester bonds,the surface of the microspheres was rapidly dissolved and eroded,and the degradation rate was significantly higher than that in acidic environment.High temperature accelerated the degradation of PLGA microspheres.Under neutral and alkaline conditions,the microspheres showed aggregation and adhesion.Under acidic conditions,the microspheres gradually decomposed into irregular fragments.The high ionic strength further promoted the surface corrosion of the microspheres,especially under extreme pH conditions.Simultaneously,PLGA microspheres encapsulating coumarin were prepared to simulate the microsphere formulation.The release rate of coumarin after degradation of the microspheres under different conditions was observed by measuring the absorbance with ultraviolet-visible spectrophotometry.The results were consistent with those of the blank microspheres.This study revealed that the degradation of PLGA microspheres was significantly pH-dependent,temperature sensitive and ion strength responsive.These findings not only helped to understand and optimize the long-term stability and controlled release performance of drug-carrying microspheres,but also provided a theoretical basis for further improvement of PLGA-based drug carrier design.
6.Visualization and Analysis of Sweat Pore Features in Latent Fingerprints Using Core-Shell Structured Composite Nanofibrous Membrane
Shi-Yue MA ; Ya-Li PEI ; Hong-Yu CHEN ; Xin DU ; Yan-Feng ZHANG ; Rong-Liang MA ; Mei-Qin ZHANG
Chinese Journal of Analytical Chemistry 2025;53(8):1269-1278
Introducing fingerprint level 3 features(especially sweat pores)in fingerprint recognition can significantly improve the value of fingerprints.However,conventional fingerprint visualization methods suffer from issues such as poor stability and reproducibility,insufficient resolution,and feature masking in detecting level 3 features.Electrospun membrane has unique advantages in latent fingerprint(LFP)detection due to its excellent adsorption performance and high specific surface area,and thus its application potential in LFP visualization urgently need to be explored.A novel pore visualization method based on core-shell structured PAN-Flu/PVP composite nanofibrous membrane was proposed in this work.Specifically,the PAN-Flu/PVP composite nanofibrous membrane was prepared via coaxial electrospinning technology,with polyacrylonitrile(PAN)loaded with fluorescein(Flu)as the core and polyvinylpyrrolidone(PVP)as the shell.The experimental results showed that the prepared PAN Flu/PVP composite nanofibrous membrane had a porous structure and excellent adsorption performance.Based on the water solubility of the outer shell PVP and the water induced fluorescence enhancement effect of the core Flu,high-resolution visualization of sweat pores could be achieved within 2 s.The optimization experiment showed that the best quality of sweat latent fingerprints was obtained when the Flu content was 4 mg/mL,the spinning time was 1 h,and the sweating time was 2 min.Through repeated fingerprinting and live fingerprint comparison experiment,the strong stability and high reproducibility of the as-produced membrane in displaying fingerprint sweat pores were finally verified.In summary,the development method could quickly,stably and accurately extract the spatial distribution and activity level of fingerprint sweat pores,which was of great significance for improving the utilization and value of fingerprints.
7.Usefulness of intraoperative choledochoscopy in laparoscopic subtotal cholecystectomy for severe cholecystitis
Rui-Hui ZHANG ; Xiang-Nan WANG ; Yue-Feng MA ; Xue-Qian TANG ; Mei-Ju LIN ; Li-Jun SHI ; Jing-Yi LI ; Hong-Wei ZHANG
Annals of Hepato-Biliary-Pancreatic Surgery 2025;29(2):192-198
Laparoscopic subtotal cholecystectomy (LSC) has been a safe and viable alternative to conversion to laparotomy in cases of severe cholecystitis. The objective of this study is to determine the utility of intraoperative choledochoscopy in LSC for the exploration of the gallbladder, cyst duct, and subsequent stone clearance of the cystic duct in cases of severe cholecystitis. A total of 72 patients diagnosed with severe cholecystitis received choledochoscopy-assisted laparoscopic subtotal cholecystectomy (CALSC). A choledochoscopy was performed to explore the gallbladder cavity and/or cystic duct, and to extract stones using a range of techniques. The clinical records, including the operative records and outcomes, were subjected to analysis. No LSC was converted to open surgery, and no bile duct or vascular injuries were sustained. All stones within the cystic duct were removed by a combination of techniques, including high-frequency needle knife electrotomy, basket, and electrohydraulic lithotripsy. A follow-up examination revealed the absence of residual bile duct stones, with the exception of one common bile duct stone, which was extracted via endoscopic retrograde cholangiopancreatography. In certain special cases, CALSC may prove to be an efficacious treatment for the management of severe cholecystitis. This technique allows for optimal comprehension of the situation within the gallbladder cavity and cystic duct, facilitating the removal of stones from the cystic duct and reducing the residue of the non-functional gallbladder remnant.
8.Robot-assisted percutaneous coronary intervention: a prospective, multicenter, randomized controlled, non-inferiority clinical trial.
Yi YU ; Zheng CHEN ; Zhi-Jian WANG ; Yue-Ping LI ; Li-Xia YANG ; Jing QI ; Jing XIE ; Tao HUANG ; Dong-Mei SHI ; Yu-Jie ZHOU
Journal of Geriatric Cardiology 2025;22(8):725-735
OBJECTIVE:
To evaluate the safety and effectiveness of robot-assisted percutaneous coronary intervention (R-PCI) compared to traditional manual percutaneous coronary intervention (M-PCI).
METHODS:
This prospective, multicenter, randomized controlled, non-inferior clinical trial enrolled patients with coronary heart disease who met the inclusion criteria and had indications for elective percutaneous coronary intervention. Participants were randomly assigned to either the R-PCI group or the M-PCI group. Primary endpoints were clinical and technical success rates. Clinical success was defined as visually estimated residual post-percutaneous coronary intervention stenosis < 30% with no 30-day major adverse cardiac events. Technical success in the R-PCI group was defined as successful completion of percutaneous coronary intervention using the ETcath200 robot-assisted system, without conversion to M-PCI in the event of a guidewire or balloon/stent catheter that was unable to cross the vessel or was poorly supported by the catheter. Secondary endpoints included total procedure time, percutaneous coronary intervention procedure time, fluoroscopy time, contrast volume, operator radiation exposure, air kerma, and dose-area product.
RESULTS:
The trial enrolled 152 patients (R-PCI: 73 patients, M-PCI: 79 patients). Lesions were predominantly B2/C type (73.6%). Both groups achieved 100% clinical success rate. No major adverse cardiac events occurred during the 30-day follow-up. The R-PCI group had a technical success rate of 100%. The R-PCI group had longer total procedure and fluoroscopy times, but lower operator radiation exposure. The percutaneous coronary intervention procedure time, contrast volume, air kerma, and dose-area product were similar between the two groups.
CONCLUSIONS
For certain complex lesions, performing percutaneous coronary intervention using the ETcath200 robot-assisted system is safe and effective and does not result in conversion to M-PCI.
9.Targeted screening and profiling of massive components of colistimethate sodium by two-dimensional-liquid chromatography-mass spectrometry based on self-constructed compound database.
Xuan LI ; Minwen HUANG ; Yue-Mei ZHAO ; Wenxin LIU ; Nan HU ; Jie ZHOU ; Zi-Yi WANG ; Sheng TANG ; Jian-Bin PAN ; Hian Kee LEE ; Yao-Zuo YUAN ; Taijun HANG ; Hai-Wei SHI ; Hongyuan CHEN
Journal of Pharmaceutical Analysis 2025;15(2):101072-101072
In-depth study of the components of polymyxins is the key to controlling the quality of this class of antibiotics. Similarities and variations of components present significant analytical challenges. A two-dimensional (2D) liquid chromatography-mass spectrometr (LC-MS) method was established for screening and comprehensive profiling of compositions of the antibiotic colistimethate sodium (CMS). A high concentration of phosphate buffer mobile phase was used in the first-dimensional LC system to get the components well separated. For efficient and high-accuracy screening of CMS, a targeted method based on a self-constructed high resolution (HR) mass spectrum database of CMS components was established. The database was built based on the commercial MassHunter Personal Compound Database and Library (PCDL) software and its accuracy of the compound matching result was verified with six known components before being applied to genuine sample screening. On this basis, the unknown peaks in the CMS chromatograms were deduced and assigned. The molecular formula, group composition, and origins of a total of 99 compounds, of which the combined area percentage accounted for more than 95% of CMS components, were deduced by this 2D-LC-MS method combined with the MassHunter PCDL. This profiling method was highly efficient and could distinguish hundreds of components within 3 h, providing reliable results for quality control of this kind of complex drugs.
10.Usefulness of intraoperative choledochoscopy in laparoscopic subtotal cholecystectomy for severe cholecystitis
Rui-Hui ZHANG ; Xiang-Nan WANG ; Yue-Feng MA ; Xue-Qian TANG ; Mei-Ju LIN ; Li-Jun SHI ; Jing-Yi LI ; Hong-Wei ZHANG
Annals of Hepato-Biliary-Pancreatic Surgery 2025;29(2):192-198
Laparoscopic subtotal cholecystectomy (LSC) has been a safe and viable alternative to conversion to laparotomy in cases of severe cholecystitis. The objective of this study is to determine the utility of intraoperative choledochoscopy in LSC for the exploration of the gallbladder, cyst duct, and subsequent stone clearance of the cystic duct in cases of severe cholecystitis. A total of 72 patients diagnosed with severe cholecystitis received choledochoscopy-assisted laparoscopic subtotal cholecystectomy (CALSC). A choledochoscopy was performed to explore the gallbladder cavity and/or cystic duct, and to extract stones using a range of techniques. The clinical records, including the operative records and outcomes, were subjected to analysis. No LSC was converted to open surgery, and no bile duct or vascular injuries were sustained. All stones within the cystic duct were removed by a combination of techniques, including high-frequency needle knife electrotomy, basket, and electrohydraulic lithotripsy. A follow-up examination revealed the absence of residual bile duct stones, with the exception of one common bile duct stone, which was extracted via endoscopic retrograde cholangiopancreatography. In certain special cases, CALSC may prove to be an efficacious treatment for the management of severe cholecystitis. This technique allows for optimal comprehension of the situation within the gallbladder cavity and cystic duct, facilitating the removal of stones from the cystic duct and reducing the residue of the non-functional gallbladder remnant.


Result Analysis
Print
Save
E-mail