1.Clinical Efficacy of Modified Huangqi Chifengtang in Treatment of IgA Nephropathy Patients and Exploration of Dose-effect Relationship of Astragali Radix
Xiujie SHI ; Meiying CHANG ; Yue SHI ; Ziyan ZHANG ; Yifan ZHANG ; Qi ZHANG ; Hangyu DUAN ; Jing LIU ; Mingming ZHAO ; Yuan SI ; Yu ZHANG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(2):9-16
ObjectiveTo explore the dose-effect relationship and safety of high, medium, and low doses of raw Astragali Radix in the modified Huangqi Chifengtang (MHCD) for treating proteinuria in immunoglobulin A (IgA) nephropathy, and to provide scientific evidence for the clinical use of high-dose Astragali Radix in the treatment of proteinuria in IgA nephropathy. MethodsA total of 120 patients with IgA nephropathy, diagnosed with Qi deficiency and blood stasis combined with wind pathogen and heat toxicity, were randomly divided into a control group and three treatment groups. The control group received telmisartan combined with a Chinese medicine placebo, while the treatment groups were given telmisartan combined with MHCD containing different doses of raw Astragali Radix (60, 30, 15 g). Each group contained 30 patients, and the treatment period was 12 weeks. Changes in 24-hour urinary protein (24 hUTP), traditional Chinese medicine (TCM) syndrome scores, effective rate, and renal function were observed before and after treatment. Safety was assessed by monitoring liver function and blood routine. ResultsAfter 12 weeks of treatment, 24 hUTP significantly decreased in the high, medium, and low-dose groups, as well as the control group (P<0.05, P<0.01). The TCM syndrome scores in the high, medium, and low-dose groups also significantly decreased (P<0.01). Comparisons between groups showed that the 24 hUTP in the high-dose group was significantly lower than in the medium, low-dose, and control groups (P<0.05, P<0.01), and the 24 hUTP in the medium-dose group was significantly lower than in the control group (P<0.05). The TCM syndrome scores in the high and medium-dose groups were significantly lower than in the low-dose and control groups (P<0.05, P<0.01). The total effective rates for proteinuria in the high, medium, low-dose, and control groups were 92.59% (25/27), 85.19% (23/27), 60.71% (17/28), and 57.14% (16/28), respectively. The effective rates in the high and medium-dose groups were significantly higher than in the low-dose and control groups (χ2=13.185, P<0.05, P<0.01). The effective rates for TCM syndrome scores in the high, medium, low-dose, and control groups were 88.89% (24/27), 81.48% (22/27), 71.43% (20/28), and 46.43% (13/28), respectively. The efficacy of TCM syndrome scores in the high and medium-dose groups was significantly higher than in the control group (χ2=14.053, P<0.01). Compared with pre-treatment values, there was no statistically significant difference in eGFR and serum creatinine in the high and medium-dose groups. However, eGFR significantly decreased in the low-dose and control groups after treatment (P<0.05), and serum creatinine levels increased significantly in the control group (P<0.05). No statistically significant differences were observed in urea nitrogen, uric acid, albumin, total cholesterol, triglycerides, liver function, and blood routine before and after treatment in any group. ConclusionThere is a dose-effect relationship in the treatment of IgA nephropathy with high, medium, and low doses of raw Astragali Radix in MHCD. The high-dose group exhibited the best therapeutic effect and good safety profile.
2.Common characteristics and regulatory mechanisms of airway mucus hypersecretion in lung disease.
Ze-Qiang LIN ; Shi-Man PANG ; Si-Yuan ZHU ; Li-Xia HE ; Wei-Guo KONG ; Wen-Ju LU ; Zi-Li ZHANG
Acta Physiologica Sinica 2025;77(5):989-1000
In a healthy human, the airway mucus forms a thin, protective liquid layer covering the surface of the respiratory tract. It comprises a complex blend of mucin, multiple antibacterial proteins, metabolic substances, water, and electrolytes. This mucus plays a pivotal role in the lungs' innate immune system by maintaining airway hydration and capturing airborne particles and pathogens. However, heightened mucus secretion in the airway can compromise ciliary clearance, obstruct the respiratory tract, and increase the risk of pathogen colonization and recurrent infections. Consequently, a thorough exploration of the mechanisms driving excessive airway mucus secretion is crucial for establishing a theoretical foundation for the eventual development of targeted drugs designed to reduce mucus production. Across a range of lung diseases, excessive airway mucus secretion manifests with unique characteristics and regulatory mechanisms, all intricately linked to mucin. This article provides a comprehensive overview of the characteristics and regulatory mechanisms associated with excessive airway mucus secretion in several prevalent lung diseases.
Humans
;
Mucus/metabolism*
;
Mucins/physiology*
;
Lung Diseases/metabolism*
;
Respiratory Mucosa/metabolism*
;
Pulmonary Disease, Chronic Obstructive/physiopathology*
;
Asthma/physiopathology*
;
Cystic Fibrosis/physiopathology*
;
Mucociliary Clearance/physiology*
3.Expert consensus on evaluation index system construction for new traditional Chinese medicine(TCM) from TCM clinical practice in medical institutions.
Li LIU ; Lei ZHANG ; Wei-An YUAN ; Zhong-Qi YANG ; Jun-Hua ZHANG ; Bao-He WANG ; Si-Yuan HU ; Zu-Guang YE ; Ling HAN ; Yue-Hua ZHOU ; Zi-Feng YANG ; Rui GAO ; Ming YANG ; Ting WANG ; Jie-Lai XIA ; Shi-Shan YU ; Xiao-Hui FAN ; Hua HUA ; Jia HE ; Yin LU ; Zhong WANG ; Jin-Hui DOU ; Geng LI ; Yu DONG ; Hao YU ; Li-Ping QU ; Jian-Yuan TANG
China Journal of Chinese Materia Medica 2025;50(12):3474-3482
Medical institutions, with their clinical practice foundation and abundant human use experience data, have become important carriers for the inheritance and innovation of traditional Chinese medicine(TCM) and the "cradles" of the preparation of new TCM. To effectively promote the transformation of new TCM originating from the TCM clinical practice in medical institutions and establish an effective evaluation index system for the transformation of new TCM conforming to the characteristics of TCM, consensus experts adopted the literature research, questionnaire survey, Delphi method, etc. By focusing on the policy and technical evaluation of new TCM originating from the TCM clinical practice in medical institutions, a comprehensive evaluation from the dimensions of drug safety, efficacy, feasibility, and characteristic advantages was conducted, thus forming a comprehensive evaluation system with four primary indicators and 37 secondary indicators. The expert consensus reached aims to encourage medical institutions at all levels to continuously improve the high-quality research and development and transformation of new TCM originating from the TCM clinical practice in medical institutions and targeted at clinical needs, so as to provide a decision-making basis for the preparation, selection, cultivation, and transformation of new TCM for medical institutions, improve the development efficiency of new TCM, and precisely respond to the public medication needs.
Medicine, Chinese Traditional/standards*
;
Humans
;
Consensus
;
Drugs, Chinese Herbal/therapeutic use*
;
Surveys and Questionnaires
4.Innovation and application of traditional Chinese medicine dispensing promoted through integration of whole-process data elements.
Huan-Fei YANG ; Si-Yu LI ; Chen-Qian YU ; Jian-Kun WU ; Fang LIU ; Li-Bin JIANG ; Chun-Jin LI ; Xiang-Fei SU ; Wei-Guo BAI ; Hua-Qiang ZHAI ; Shi-Yuan JIN ; Yong-Yan WANG
China Journal of Chinese Materia Medica 2025;50(11):3189-3196
As a new type of production factor that can empower the development of new quality productivity, the data element is an important engine to promote the high quality development of the industry. Traditional Chinese medicine(TCM) dispensing is the most basic work of TCM clinical pharmacy, and its quality directly affects the clinical efficacy of TCM. The integration of data elements and TCM dispensing can stimulate the innovation and vitality of the TCM dispensing industry and promote the high-quality and sustainable development of the industry. A large-scale, detailed, and systematic study on TCM dispensing was conducted. The innovative practice path of data fusion construction in the whole process of TCM dispensing was investigated by integrating the digital resources "nine full activities" of TCM dispensing, creating the digital dictionary of "TCM clinical information data elements", and exploring innovative applications of TCM dispensing driven by data and technology, so as to promote the standardized, digital, and intelligent development of TCM dispensing in medical health services. The research content of this project was successfully selected as the second batch of "Data element×" typical cases of National Data Administration in 2024, which is the only selected case in the field of TCM.
Medicine, Chinese Traditional/methods*
;
Drugs, Chinese Herbal
;
Humans
6.Preparation and In Vitro Degradation Characteristics Analysis of Poly(lactic-co-glycolide)Microspheres Based on Microfluidic Process
Bao-Cheng WANG ; Cong-Yu MA ; Ke WANG ; Si-Tong ZHENG ; Xiao-Yan ZHANG ; Yue-Mei ZHAO ; Xun ZHAO ; Jian-Bin PAN ; Zheng-Song GAO ; Hai-Wei SHI ; Yao-Zuo YUAN ; Hong-Yuan CHEN
Chinese Journal of Analytical Chemistry 2025;53(4):621-630
Poly(lactic-co-glycolide)(PLGA)is a key excipient in long-acting sustained-release preparations,and its degradation properties directly affect the drug release behavior.In this study,PLGA microspheres were prepared by microfluidic techniques,and the morphology changes of the microspheres were observed by scanning electron microscopy(SEM).In alkaline environment,due to the accelerated hydrolysis of ester bonds,the surface of the microspheres was rapidly dissolved and eroded,and the degradation rate was significantly higher than that in acidic environment.High temperature accelerated the degradation of PLGA microspheres.Under neutral and alkaline conditions,the microspheres showed aggregation and adhesion.Under acidic conditions,the microspheres gradually decomposed into irregular fragments.The high ionic strength further promoted the surface corrosion of the microspheres,especially under extreme pH conditions.Simultaneously,PLGA microspheres encapsulating coumarin were prepared to simulate the microsphere formulation.The release rate of coumarin after degradation of the microspheres under different conditions was observed by measuring the absorbance with ultraviolet-visible spectrophotometry.The results were consistent with those of the blank microspheres.This study revealed that the degradation of PLGA microspheres was significantly pH-dependent,temperature sensitive and ion strength responsive.These findings not only helped to understand and optimize the long-term stability and controlled release performance of drug-carrying microspheres,but also provided a theoretical basis for further improvement of PLGA-based drug carrier design.
7.Construction and Performance of CD44-targeted Teniposide Nano-delivery System for Anti-B-cell Lymphoma Activity in vitro
Chuan-Min ZHANG ; Si-Jing MEI ; Lei HAN ; Yuan-Wei SHI ; Bo-Lian XIAO ; Xiao-Li XIE ; Quan-Ping SU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):815-825
Although teniposide(VM26)is widely used in the treatment of lymphoma,its poor water sol-ubility,low bioavailability and systemic toxicities still limit its clinical application.Nano-delivery systems are effective in increasing the bioavailability and reducing the toxicity of VM26,but there is an urgent need to overcome the problem of its non-specific targeting.Therefore,in this paper,we designed and constructed a hyaluronic acid-modified teniposide-targeted nano-delivery system(VM26-TNDS),and characterised its drug encapsulation rate,particle size and zeta potential.We also investigated the effects of VM26-TNDS on B-cell lymphoma cells with different expression of CD44 receptor,in terms of cellular targeting,inhibitory effect of proliferation,and induction of apoptosis and necrosis.The results showed that the drug encapsulation efficiency of VM26-TNDS exceeded 85%,and its liquid formulation could be stably stored at 4 ℃ for more than 6 months without precipitation.Based on CD44 receptor expression,Granta-519(high expression),Raji(medium-low expression)and SU-DHL-4(almost no expression)were screened for cellular experiments.Compared with VM26-NDS,the targeted modification could effec-tively reduce the uptake of VM26-TNDS by RAW264.7 and increase the uptake of VM26-TNDS by CD44 receptor-expressing lymphoma cells.The inhibitory proliferative effect and apoptotic necrosis-inducing a-bility of VM26-TNDS were stronger than those of VM26-NDS for Granta-519 and Raji cells,whereas there was no significant difference in the inhibitory effect on proliferation and ability to induce apoptosis and necrosis between VM26-NDS and VM26-TNDS in SU-DHL-4 cells,reflecting the targeting advantage for VM26-TNDS,as expected.However,its toxic effect on B-cell lymphoma cells only reflected the targeting advantage at some concentrations(0.25 μmol/L and 0.5 μmol/L),which met the expectation.The a-bove results indicate that a teniposide-targeted nano-delivery system,VM26-TNDS,has been successfully prepared in this study.VM26-TNDS improves the delivery efficiency of VM26 by targeting human B-cell lymphoma cells expressing the CD44 receptor,thus killing human B-cell lymphoma cells more effectively and overcoming the problem of non-specific targeting in drug delivery to improve the therapeutic effect.Its biological therapeutic effects and mechanisms still need to be proved by more in vitro and in vivo ex-perimental evidence.
8.Application progress of micro-CT and finite element analysis techniques in scaphoid bone research
Yuan LYU ; De-zhou ZHANG ; Hai-long QIAN ; Si-min WANG ; Chao-qun WANG ; Kun LI ; Jie CHEN ; Xue BAI ; Hai-long ZHAO ; Shao-jie ZHANG ; Yuan MA ; Zhi-jun LI ; Jun SHI ; Xing WANG
Journal of Regional Anatomy and Operative Surgery 2025;34(2):168-173
The scaphoid bone is one of the important bone of hand,which is frequently injured and difficult to treat in clinical practice.Therefore,it is very important to deeply study the microstructure and biomechanical characteristics of the scaphoid bone for understanding its injury mechanism and optimizing treatment scheme.Microcomputed tomography(micro-CT)provides high-resolution imaging of bone tissue,while finite element analysis can help to simulate the stress distribution and behavioral patterns of the scaphoid bone under various physiological and pathological states.The high-resolution three-dimensional image of the scaphoid bone obtained by micro-CT technology can be used to construct finite element models of real anatomical structure of the scaphoid bone,thus achieving accurate simulation of the mechanical properties of the scaphoid bone.The fusion of these two advanced technologies provides a new perspective for revealing the structural and functional relationships and injury mechanism of the scaphoid bone.Therefore,this paper reviews the anatomical characteristics of the scaphoid bone and its biomechanical behavior in different states,emphasizing the specific applications and advantages of micro-CT and finite element analysis techniques in the study of the scaphoid bone.By summarizing the research findings in recent years,this paper provides novel scientific basis and methods for the diagnosis,treatment,and prevention of scaphoid bone-related disorders.
9.Construction and Performance of CD44-targeted Teniposide Nano-delivery System for Anti-B-cell Lymphoma Activity in vitro
Chuan-Min ZHANG ; Si-Jing MEI ; Lei HAN ; Yuan-Wei SHI ; Bo-Lian XIAO ; Xiao-Li XIE ; Quan-Ping SU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):815-825
Although teniposide(VM26)is widely used in the treatment of lymphoma,its poor water sol-ubility,low bioavailability and systemic toxicities still limit its clinical application.Nano-delivery systems are effective in increasing the bioavailability and reducing the toxicity of VM26,but there is an urgent need to overcome the problem of its non-specific targeting.Therefore,in this paper,we designed and constructed a hyaluronic acid-modified teniposide-targeted nano-delivery system(VM26-TNDS),and characterised its drug encapsulation rate,particle size and zeta potential.We also investigated the effects of VM26-TNDS on B-cell lymphoma cells with different expression of CD44 receptor,in terms of cellular targeting,inhibitory effect of proliferation,and induction of apoptosis and necrosis.The results showed that the drug encapsulation efficiency of VM26-TNDS exceeded 85%,and its liquid formulation could be stably stored at 4 ℃ for more than 6 months without precipitation.Based on CD44 receptor expression,Granta-519(high expression),Raji(medium-low expression)and SU-DHL-4(almost no expression)were screened for cellular experiments.Compared with VM26-NDS,the targeted modification could effec-tively reduce the uptake of VM26-TNDS by RAW264.7 and increase the uptake of VM26-TNDS by CD44 receptor-expressing lymphoma cells.The inhibitory proliferative effect and apoptotic necrosis-inducing a-bility of VM26-TNDS were stronger than those of VM26-NDS for Granta-519 and Raji cells,whereas there was no significant difference in the inhibitory effect on proliferation and ability to induce apoptosis and necrosis between VM26-NDS and VM26-TNDS in SU-DHL-4 cells,reflecting the targeting advantage for VM26-TNDS,as expected.However,its toxic effect on B-cell lymphoma cells only reflected the targeting advantage at some concentrations(0.25 μmol/L and 0.5 μmol/L),which met the expectation.The a-bove results indicate that a teniposide-targeted nano-delivery system,VM26-TNDS,has been successfully prepared in this study.VM26-TNDS improves the delivery efficiency of VM26 by targeting human B-cell lymphoma cells expressing the CD44 receptor,thus killing human B-cell lymphoma cells more effectively and overcoming the problem of non-specific targeting in drug delivery to improve the therapeutic effect.Its biological therapeutic effects and mechanisms still need to be proved by more in vitro and in vivo ex-perimental evidence.
10.Application progress of micro-CT and finite element analysis techniques in scaphoid bone research
Yuan LYU ; De-zhou ZHANG ; Hai-long QIAN ; Si-min WANG ; Chao-qun WANG ; Kun LI ; Jie CHEN ; Xue BAI ; Hai-long ZHAO ; Shao-jie ZHANG ; Yuan MA ; Zhi-jun LI ; Jun SHI ; Xing WANG
Journal of Regional Anatomy and Operative Surgery 2025;34(2):168-173
The scaphoid bone is one of the important bone of hand,which is frequently injured and difficult to treat in clinical practice.Therefore,it is very important to deeply study the microstructure and biomechanical characteristics of the scaphoid bone for understanding its injury mechanism and optimizing treatment scheme.Microcomputed tomography(micro-CT)provides high-resolution imaging of bone tissue,while finite element analysis can help to simulate the stress distribution and behavioral patterns of the scaphoid bone under various physiological and pathological states.The high-resolution three-dimensional image of the scaphoid bone obtained by micro-CT technology can be used to construct finite element models of real anatomical structure of the scaphoid bone,thus achieving accurate simulation of the mechanical properties of the scaphoid bone.The fusion of these two advanced technologies provides a new perspective for revealing the structural and functional relationships and injury mechanism of the scaphoid bone.Therefore,this paper reviews the anatomical characteristics of the scaphoid bone and its biomechanical behavior in different states,emphasizing the specific applications and advantages of micro-CT and finite element analysis techniques in the study of the scaphoid bone.By summarizing the research findings in recent years,this paper provides novel scientific basis and methods for the diagnosis,treatment,and prevention of scaphoid bone-related disorders.

Result Analysis
Print
Save
E-mail