1.Clinical and Neuroelectrophysiological Features of Autoimmune Nodopathy
Hongfei TAI ; Xunyan HUANG ; Songtao NIU ; Bin CHEN ; Yuzhi SHI ; Xingao WANG ; Fan JIAN ; Hua PAN ; Zaiqiang ZHANG
JOURNAL OF RARE DISEASES 2026;5(2):191-199
To summarize the clinical characteristics, antibody spectrum and neuroelectrophysiological features of autoimmune nodopathy(AN), and to explore the phenotypic differences among different antibody-positive subgroups. The clinical and electrophysiological data of patients definitely diagnosed with AN in Beijing Tiantan Hospital, Capital Medical University, from October 2018 to January 2026 were retrospectively analyzed. A total of 33 patients with AN were included. Antibody examination results showed that, anti-neurofascin(NF)155 antibody was the most prevalent, detected in 17 patients(51.50%), followed by anti-contactin-1(CNTN1) antibody in 8 patients(24.24%). Anti-NF186 antibody(4 cases, 12.12%), anti-contactin-associated protein 1(Caspr1) antibody(2 cases, 6.06%) and dual-target antibody positivity(2 cases, 6.06%) were relatively uncommon. The main clinical manifestations of AN patients included symmetric distal paresthesia of the extremities(32 cases, 96.97%), limb weakness(31 cases, 93.93%) and sensory ataxia(25 cases, 75.76%). Different antibody-positive subgroups presented distinct phenotypic features: patients with positive anti-NF155 antibody had a relatively younger age of onset, chronic onset and a high incidence of tremor, which was dominated by immunoglobulin(Ig)G4 subclass antibodies; patients with positive anti-CNTN1 antibody had a relatively advanced age of onset, mostly presented with acute or subacute onset, and were prone to complicated nephrotic syndrome; patients with positive anti-NF186 antibody had relatively mild nerve conduction damage; patients with anti-Caspr1 antibody manifested acute or subacute onset, with relatively elevated cerebrospinal fluid protein level and 24-h intrathecal IgG synthesis rate. The prominent neuroelectrophysiological manifestations of AN included decreased motor and sensory nerve conduction velocities, prolonged distal latency, frequent non-compressive conduction block and abnormal temporal dispersion. Definite sensory nerve action potentials could not be elicited in more than half of the patients. Patients with AN show high heterogeneity in clinical and neuroelectrophysiological characteristics, and different antibody-positive subgroups correspond to specific clinical and neuroelectrophysiological phenotypes.
2.Plasma miRNA testing in the differential diagnosis of very early-stage hepatocellular carcinoma: a multicenter real-world study
Jie HU ; Ying XU ; Ao HUANG ; Lei YU ; Zheng WANG ; Xiaoying WANG ; Xinrong YANG ; Zhenbin DING ; Qinghai YE ; Yinghong SHI ; Shuangjian QIU ; Huichuan SUN ; Qiang GAO ; Jia FAN ; Jian ZHOU
Chinese Journal of Clinical Medicine 2025;32(3):350-354
Objective To explore the application of plasma 7 microRNA (miR7) testing in the differential diagnosis of very early-stage hepatocellular carcinoma (HCC). Methods This study is a multicenter real-world study. Patients with single hepatic lesion (maximum diameter≤2 cm) who underwent plasma miR7 testing at Zhongshan Hospital, Fudan University, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Anhui Provincial Hospital, and Peking University People’s Hospital between January 2019 and December 2024 were retrospectively enrolled. Patients were divided into very early-stage HCC group and non-HCC group, and the clinical pathological characteristics of the two groups were compared. The value of plasma miR7 levels, alpha-fetoprotein (AFP), and des-gamma-carboxy prothrombin (DCP) in the differential diagnosis of very early-stage HCC was evaluated using receiver operating characteristic (ROC) curves and area under the curve (AUC). In patients with both negative AFP and DCP (AFP<20 ng/mL, DCP<40 mAU/mL), the diagnostic value of plasma miR7 for very early-stage HCC was analyzed. Results A total of 64 528 patients from 4 hospitals underwent miR7 testing, and 1 682 were finally included, of which 1 073 were diagnosed with very early-stage HCC and 609 were diagnosed with non-HCC. The positive rate of miR7 in HCC patients was significantly higher than that in non-HCC patients (67.9% vs 24.3%, P<0.001). ROC curves showed that the AUCs for miR7, AFP, and DCP in distinguishing HCC patients from the non-HCC individuals were 0.718, 0.682, and 0.642, respectively. The sensitivities were 67.85%, 43.71%, and 44.45%, and the specificities were 75.70%, 92.78%, and 83.91%, respectively. The pairwise comparison of AUCs showed that the diagnostic efficacy of plasma miR7 detection was significantly better than that of AFP or DCP (P<0.05). Although its specificity was slightly lower than AFP and DCP, the sensitivity was significantly higher. Among patients negative for both AFP and DCP, miR7 maintained an AUC of 0.728 for diagnosing very early-stage HCC, with 67.82% sensitivity and 77.73% specificity. Conclusions Plasma miR7 testing is a potential molecular marker with high sensitivity and specificity for the differential diagnosis of small hepatic nodules. In patients with very early-stage HCC lacking effective molecular markers (negative for both AFP and DCP), miR7 can serve as a novel and effective molecular marker to assist diagnosis.
3.Robot-assisted percutaneous coronary intervention: a prospective, multicenter, randomized controlled, non-inferiority clinical trial.
Yi YU ; Zheng CHEN ; Zhi-Jian WANG ; Yue-Ping LI ; Li-Xia YANG ; Jing QI ; Jing XIE ; Tao HUANG ; Dong-Mei SHI ; Yu-Jie ZHOU
Journal of Geriatric Cardiology 2025;22(8):725-735
OBJECTIVE:
To evaluate the safety and effectiveness of robot-assisted percutaneous coronary intervention (R-PCI) compared to traditional manual percutaneous coronary intervention (M-PCI).
METHODS:
This prospective, multicenter, randomized controlled, non-inferior clinical trial enrolled patients with coronary heart disease who met the inclusion criteria and had indications for elective percutaneous coronary intervention. Participants were randomly assigned to either the R-PCI group or the M-PCI group. Primary endpoints were clinical and technical success rates. Clinical success was defined as visually estimated residual post-percutaneous coronary intervention stenosis < 30% with no 30-day major adverse cardiac events. Technical success in the R-PCI group was defined as successful completion of percutaneous coronary intervention using the ETcath200 robot-assisted system, without conversion to M-PCI in the event of a guidewire or balloon/stent catheter that was unable to cross the vessel or was poorly supported by the catheter. Secondary endpoints included total procedure time, percutaneous coronary intervention procedure time, fluoroscopy time, contrast volume, operator radiation exposure, air kerma, and dose-area product.
RESULTS:
The trial enrolled 152 patients (R-PCI: 73 patients, M-PCI: 79 patients). Lesions were predominantly B2/C type (73.6%). Both groups achieved 100% clinical success rate. No major adverse cardiac events occurred during the 30-day follow-up. The R-PCI group had a technical success rate of 100%. The R-PCI group had longer total procedure and fluoroscopy times, but lower operator radiation exposure. The percutaneous coronary intervention procedure time, contrast volume, air kerma, and dose-area product were similar between the two groups.
CONCLUSIONS
For certain complex lesions, performing percutaneous coronary intervention using the ETcath200 robot-assisted system is safe and effective and does not result in conversion to M-PCI.
4.Expert consensus on the application of nasal cavity filling substances in nasal surgery patients(2025, Shanghai).
Keqing ZHAO ; Shaoqing YU ; Hongquan WEI ; Chenjie YU ; Guangke WANG ; Shijie QIU ; Yanjun WANG ; Hongtao ZHEN ; Yucheng YANG ; Yurong GU ; Tao GUO ; Feng LIU ; Meiping LU ; Bin SUN ; Yanli YANG ; Yuzhu WAN ; Cuida MENG ; Yanan SUN ; Yi ZHAO ; Qun LI ; An LI ; Luo BA ; Linli TIAN ; Guodong YU ; Xin FENG ; Wen LIU ; Yongtuan LI ; Jian WU ; De HUAI ; Dongsheng GU ; Hanqiang LU ; Xinyi SHI ; Huiping YE ; Yan JIANG ; Weitian ZHANG ; Yu XU ; Zhenxiao HUANG ; Huabin LI
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(4):285-291
This consensus will introduce the characteristics of fillers used in the surgical cavities of domestic nasal surgery patients based on relevant literature and expert opinions. It will also provide recommendations for the selection of cavity fillers for different nasal diseases, with chronic sinusitis as a representative example.
Humans
;
Nasal Cavity/surgery*
;
Nasal Surgical Procedures
;
China
;
Consensus
;
Sinusitis/surgery*
;
Dermal Fillers
5.Erratum: Author correction to "Generation of αGal-enhanced bifunctional tumor vaccine" Acta Pharm Sin B 12 (2022) 3177-3186.
Jian HE ; Yu HUO ; Zhikun ZHANG ; Yiqun LUO ; Xiuli LIU ; Qiaoying CHEN ; Pan WU ; Wei SHI ; Tao WU ; Chao TANG ; Huixue WANG ; Lan LI ; Xiyu LIU ; Yong HUANG ; Yongxiang ZHAO ; Lu GAN ; Bing WANG ; Liping ZHONG
Acta Pharmaceutica Sinica B 2025;15(2):1207-1207
[This corrects the article DOI: 10.1016/j.apsb.2022.03.002.].
6.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
7.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
8.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
9.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
10.Impacts of the radiosensitivity of cell lines on a microdosimetric kinetic model
Honghu SONG ; Zun PIAO ; Guomin HUANG ; Jian SHI ; Ming CHEN ; Xiaoyan HUANG
Chinese Journal of Radiological Medicine and Protection 2025;45(5):416-422
Objective:To investigate the impacts of the radiosensitivity of cell lines on a microdosimetric kinetic model (MKM) used in carbon-ion radiotherapy.Methods:The saturation-corrected specific energy ( ) of monoenergetic carbon ions was calculated using the Kiefer-Chatterjee (K-C) track structure model. Correction curve f(LET) was derived from experimental data on relative biological effectiveness (RBE) (RBE DSB-LET) defined based on the double-strand DNA break of the Chinese hamster ovary (CHO) and Fibroblast cell lines irradiated using carbon ions with varying linear energy transfer (LET) values. Then, based on the MKM, the D10-LET curves, as well as α and β databases, of the CHO and Fibroblast cell lines with varying radiosensitivity were determined. Results:Compared to the clinically applied MKM, the predicted D10 after correction while accounting for cell line radiosensitivity agreed better with experimental D10 values of the CHO and Fibroblast cell lines. Specifically, compared to experimental values in the literature, the D10 values calculated in the study and determined using the MKM showed mean squared errors (MSEs) of 0.04 and 0.71, for the CHO cell line and 0.35 and 0.55, respectively, for the Fibroblast cell line. For monoenergetic carbon ions with varying LET values, the calculated α and β values generally increased with cellular radiosensitivity. Conclusions:Incorporating cellular radiosensitivity into the MKM framework serves as a more specific method for RBE assessment while also providing a reference for advancing MKM applications and achieving the fine-scale calculations of RBE in carbon-ion radiotherapy.

Result Analysis
Print
Save
E-mail