1.Central nervous system infection:Expert consensus on imaging examination standards(2024 edition)
Chen QIAO ; Ting LIU ; Jianming CAI ; Qing LU ; Weijun SITU ; Meng ZHENG ; Zhenying XIA ; Yuan QU ; Ting LIANG ; Guangping ZHENG ; Hongkai ZHANG ; Shengyuan LAI ; Hongjun LI
Chinese Journal of Medical Imaging Technology 2025;41(6):857-860
Imaging examination is a crucial part in diagnosis and treatment of central nervous system infection(CNSI),involving complex imaging sequences and parameters.This consensus was jointly written by multiple CNSI imaging experts in China,aimed to standardize imaging examination of CNSI.
2.Research progress and nursing implications on the dose of early mobilization in ICU
Shengyuan CAI ; Junqing CHU ; Wenbo QIAO ; Yayu REN ; Meiling WENG ; Zhenyuan DONG ; Feifei ZHOU ; Chunhua GAO
Chinese Journal of Nursing 2025;60(19):2413-2418
Precise management of the activity dose is a core component of the(early mobilization,EM)plan for ICU patients.However,the lack of clinical practice guidelines related to EM dose of existing programs hinders the implementation and development of EM in ICU patients to some extent.Therefore,this review focuses on 4 aspects,covering the definition of activity dose,assessment tools,the current clinical implementation status,and implications for future nursing.The aim is to systematically review the assessment tools and intervention strategies for the activity dose of EM in ICU patients,providing a reference for optimization of EM programs.
3.Research progress and nursing implications on the dose of early mobilization in ICU
Shengyuan CAI ; Junqing CHU ; Wenbo QIAO ; Yayu REN ; Meiling WENG ; Zhenyuan DONG ; Feifei ZHOU ; Chunhua GAO
Chinese Journal of Nursing 2025;60(19):2413-2418
Precise management of the activity dose is a core component of the(early mobilization,EM)plan for ICU patients.However,the lack of clinical practice guidelines related to EM dose of existing programs hinders the implementation and development of EM in ICU patients to some extent.Therefore,this review focuses on 4 aspects,covering the definition of activity dose,assessment tools,the current clinical implementation status,and implications for future nursing.The aim is to systematically review the assessment tools and intervention strategies for the activity dose of EM in ICU patients,providing a reference for optimization of EM programs.
4.Central nervous system infection:Expert consensus on imaging examination standards(2024 edition)
Chen QIAO ; Ting LIU ; Jianming CAI ; Qing LU ; Weijun SITU ; Meng ZHENG ; Zhenying XIA ; Yuan QU ; Ting LIANG ; Guangping ZHENG ; Hongkai ZHANG ; Shengyuan LAI ; Hongjun LI
Chinese Journal of Medical Imaging Technology 2025;41(6):857-860
Imaging examination is a crucial part in diagnosis and treatment of central nervous system infection(CNSI),involving complex imaging sequences and parameters.This consensus was jointly written by multiple CNSI imaging experts in China,aimed to standardize imaging examination of CNSI.
5.Study on the sensitivity of a volumetric modulated arc therapy plan verification equipment on multi-leaf collimator opening and closing errors and its gamma pass rate limit.
Jinyou HU ; Lian ZOU ; Shaoxian GU ; Ningyu WANG ; Fengjie CUI ; Shengyuan ZHANG ; Chu'ou YIN ; Yunzhu CAI ; Chengjun GOU ; Zhangwen WU
Journal of Biomedical Engineering 2023;40(1):133-140
To investigate the γ pass rate limit of plan verification equipment for volumetric modulated arc therapy (VMAT) plan verification and its sensitivity on the opening and closing errors of multi-leaf collimator (MLC), 50 cases of nasopharyngeal carcinoma VMAT plan with clockwise and counterclockwise full arcs were randomly selected. Eight kinds of MLC opening and closing errors were introduced in 10 cases of them, and 80 plans with errors were generated. Firstly, the plan verification was conducted in the form of field-by-field measurement and true composite measurement. The γ analysis with the criteria of 3% dose difference, distance to agreement of 2 mm, 10% dose threshold, and absolute dose global normalized conditions were performed for these fields. Then gradient analysis was used to investigate the sensitivity of field-by-field measurement and true composite measurement on MLC opening and closing errors, and the receiver operating characteristic curve (ROC) was used to investigate the optimal threshold of γ pass rate for identifying errors. Tolerance limits and action limits for γ pass rates were calculated using statistical process control (SPC) method for another 40 cases. The error identification ability using the tolerance limit calculated by SPC method and the universal tolerance limit (95%) were compared with using the optimal threshold of ROC. The results show that for the true composite measurement, the clockwise arc and the counterclockwise arc, the descent gradients of the γ passing rate with per millimeter MLC opening error are 10.61%, 7.62% and 6.66%, respectively, and the descent gradients with per millimeter MLC closing error are 9.75%, 7.36% and 6.37%, respectively. The optimal thresholds obtained by the ROC method are 99.35%, 97.95% and 98.25%, respectively, and the tolerance limits obtained by the SPC method are 98.98%, 97.74% and 98.62%, respectively. The tolerance limit calculated by SPC method is close to the optimal threshold of ROC, both of which could identify all errors of ±2 mm, while the universal tolerance limit can only partially identify them, indicating that the universal tolerance limit is not sensitive on some large errors. Therefore, considering the factors such as ease of use and accuracy, it is suggested to use the true composite measurement in clinical practice, and to formulate tolerance limits and action limits suitable for the actual process of the institution based on the SPC method. In conclusion, it is expected that the results of this study can provide some references for institutions to optimize the radiotherapy plan verification process, set appropriate pass rate limit, and promote the standardization of plan verification.
Humans
;
Radiotherapy, Intensity-Modulated
;
Immune Tolerance
;
Nasopharyngeal Carcinoma
;
ROC Curve
;
Nasopharyngeal Neoplasms/radiotherapy*
6.Impact of increased CD4+ CD25+ FOXP3+ regulatory T cells on tumor recurrence in liver transplantation for hepatocellular carcinoma
Min WU ; Fan HE ; Shengyuan XU ; Zhao DING ; Ming CAI ; Hongzhou LI ; Fanying MENG ; Xiang ZHENG ; Zhishui CHEN
Chinese Journal of Hepatobiliary Surgery 2010;16(7):516-519
Objective To investigate the impact of CD4+ CD25+ FOXP3+ regulatory T(Treg) cells on tumor recurrence in liver transplantation for hepatocellular carcinoma (HCC). Methods Im-munohistochemistry and flow cytometry were used for analysis of the frequency of Treg. Meanwhile,it was compared with that of non-cancer liver transplantation patients. Results The frequency of CD4+CD25+ FOXP3+ regulatory T cells in the blood of HCC liver transplantation was (10. 15 ±1. 00) % , which was significantly higher than that in the normal control group (3. 20±1. 18) %. Cir-culating CD4+ CD25+ FOXP3+ Treg frequency was increased significantly and correlated with the tumor recurrence in the HCC patients. An abundant accumulation of Treg concurrent with significant-ly reduced infiltration of CD8+T cells was found in tumor regions. Conclusion Increased CD4+ D25+FoxP3+ Treg may impair the effectors function of CD8+ T cells, promote the tumor recurrence and re-present a therapeutic target for HCC liver transplantation.
7.MR imaging of meningeal carcinomatosis by systemic malignancy.
Lin MA ; Shengyuan YU ; Youquan CAI ; Li LIANG ; Xinggao GUO
Chinese Medical Sciences Journal 2003;18(1):36-40
OBJECTIVETo investigate the magnetic resonance (MR) features of meningeal carcinomatosis, and to improve the ability in understanding and diagnosing meningeal carcinomatosis by MR findings.
METHODSEleven cases with proven meningeal carcinomatosis were studied by conventional and Gd-DTPA enhanced MR imaging. The enhancement patterns and features, as well as the types of meningeal involvement, were retrospectively analyzed.
RESULTSConventional MR imaging showed no evident meningeal abnormalities. After the administration of Gd-DTPA, abnormal pia mater enhancement was detected in 9 cases, demonstrating as the continuous, thin, and lineal high signal intensity on the brain surface that could descend into the sulci. The abnormal pial enhancement occurred on the cortical surfaces of cerebellum, brainstem, and cerebrum. No abnormal enhancement in the subarachnoid space was found. Abnormal dura-arachnoid enhancement was seen in 3 cases, showing as the continuous, thick, and curvilineal high signal intensity over the convexities or in the tentorium without extension into the cortical sulci. Cerebral dura-arachnoid involvement was found in all 3 cases and one of them also showed abnormal enhancement in cerebellar dura-arachnoid and tentorium. Of the 11 cases, 9 with pial involvement had abnormal cerebrospinal fluid (CSF) results, 2 involving only the dura-arachnoid had normal CSF results.
CONCLUSIONMeningeal carcinomatosis could be well demonstrated by Gd-DTPA enhanced MR imaging, and its type could be differentiated by the enhancement features. Combined with the clinical information, Gd-enhanced MR imaging may lead to the diagnosis and guide the therapy of meningeal carcinomatosis.
Adolescent ; Adult ; Aged ; Breast Neoplasms ; pathology ; Child ; Contrast Media ; Female ; Gadolinium DTPA ; Humans ; Image Enhancement ; Lung Neoplasms ; pathology ; Magnetic Resonance Imaging ; Male ; Meningeal Neoplasms ; diagnosis ; secondary ; Middle Aged ; Precursor Cell Lymphoblastic Leukemia-Lymphoma ; pathology ; Retrospective Studies ; Spinal Cord Neoplasms ; diagnosis ; secondary

Result Analysis
Print
Save
E-mail