1.Diagnostic value of serum Mac-2 binding protein for the severity of schistosomiasis-induced liver fibrosis
Jun WU ; Meiqun LUO ; Shuying XIE ; Ronghua ZHU ; Hui XU ; Long TANG ; Fei HU ; Sheng DING
Chinese Journal of Schistosomiasis Control 2026;38(1):38-43
Objective To evaluate the value of serum Mac-2 binding protein (M2BP) for assessment of the severity of schisto somiasis-induced liver fibrosis, so as to provide insights into non-invasive diagnosis and disease surveillance of liver fibrosis caused by schistosomiasis. Methods A total of 234 individuals with a history of Schistosoma japonicum infection were sampled from Xinhua Village, Lushan City, Jiangxi Province from 2019 to 2020, and 234 serum samples were collected from all participants. All participants received B-ultrasound examinations of the liver. Serum samples were categorized into four groups (grades 0, Ⅰ, Ⅱ and Ⅲ schistosomiasis-induced liver fibrosis groups) according to B-ultrasound examination results, and then, each group was randomly divided into a receiver operating characteristic (ROC) curve group and an efficacy assessment group at a ratio of 7∶3. Serum M2BP concentration was measured in four groups using the enzyme-linked immunosorbent assay (ELISA), and differences in serum M2BP concentrations were compared with analysis of variance and Spearman correlation analysis. Serum M2BP concentration was subjected to ROC curve analysis among individuals with different grades of schistosomiasis-induced liver fibrosis in the ROC curve group to determine the optimal diagnostic threshold of M2BP concentration at different fibrosis grades, and the area under the ROC curve (AUC) was calculated to evaluate the diagnostic performance. The diagnostic accuracy was verified by comparing the accordance rate and Kappa consistency test in the efficacy assessment group. Results Among 234 serum samples, there were 79 samples with grade 0 schistosomiasis-induced liver fibrosis, 87 samples with Grade Ⅰ, 46 samples with Grade Ⅱ and 22 samples with Grade Ⅲ according to the B-ultrasound examinations. The mean serum M2BP concentrations were (0.40 ± 0.31) [95% confidence interval (CI): (0.33, 0.47)], (0.64 ± 0.48) [95% CI: (0.53, 0.74)], (1.76 ± 0.58) [95% CI: (1.59, 1.93)] μg/mL and (2.56 ± 0.93) [95% CI: (2.14, 2.97)] μg/mL in the four groups, respectively (F = 150.796, P < 0.001), and the severity of schistosomiasis-induced liver fibrosis significantly positively correlated with serum M2BP concentration (rs = 0.715, P < 0. 001). The sample sizes of grades 0, Ⅰ, Ⅱ and Ⅲ schistosomiasis-induced liver fibrosis sera were randomly allocated as follows: 55 versus 24, 61 versus 26, 32 versus 14, and 15 versus 7 in the ROC curve and efficacy assessment groups, respectively, and the serum M2BP concentrations were (0.39 ± 0.29) μg/mL and (0.42 ± 0.36) μg/mL (F = 0.196, P > 0.05), (0.59 ± 0.47) μg/mL and (0.75 ± 0.51) μg/mL (F = 1.967, P > 0.05), (1.73 ± 0.59) μg/mL and (1.85 ± 0.57) μg/mL (F = 0.417, P > 0.05), and (2.46 ± 0.64) μg/mL and (2.76 ± 1.41) μg/mL (F = 0.491, P > 0.05), respectively. ROC curve analysis showed that the optimal diagnostic thresholds of serum M2BP concentration were 0.347 86 μg/mL (AUC = 0.635, P < 0.05), 1.188 83 μg/mL (AUC = 0.938, P < 0.000 1) and 2.021 21 μg/mL (AUC = 0.821, P < 0.000 1) for grade Ⅰ, Ⅱ and Ⅲ schistosomiasis-induced liver fibrosis. In addition, the accordance rates between the optimal diagnostic threshold of serum M2BP and B-ultrasound examinations for predicting grade Ⅰ, Ⅱ and Ⅲ schistosomiasis-induceed liver fibrosis were 69.23%, 85.71% and 71.43% (χ2 = 1.340, P > 0.05), and the overall Kappa consistency test showed moderate consistency [Kappa = 0.608, 95% CI: (0.428, 0.788); Z = 6.609, P < 0.000 1]. Conclusions Serum M2BP may serve as a potential biomarker for assessing moderate to advanced schistosomiasis-induced liver fibrosis; however, its diagnostic value for early-stage schistosomiasis-induced liver fibrosis remains limited.
2.Clinical Efficacy of Juanbitang Hot Compress Pack Combined with Intensive Rehabilitation Training in Ameliorating Hemiplegia After Stroke
Yuqin SHENG ; Yong YU ; Yan ZHANG ; Yuqing XIE ; Qing LIN ; Qian HU ; Longyu ZHANG ; Hongmei XU ; Xiaohong FAN ; Shouliang MA
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(17):210-218
ObjectiveTo explore the clinical efficacy of Juanbitang hot compress pack combined with intensive rehabilitation training in stroke patients with hemiplegia. MethodsA total of 80 stroke patients with hemiplegia were selected and assigned into a control group (40 cases) and an observation group (40 cases) according to the random number table method. The control group received conventional rehabilitation training and nursing intervention,while the observation group was additionally treated with Juanbitang hot compress pack. The two groups were compared in terms of the neurological function (national institute of health stroke scale score,NIHSS score),muscle strength,motor function (fugl-meyer assessment scale score,FMA score),daily living activity (modified barthel index,MBI),balance ability (berg balance scale score,BBS score),trunk control ability (Sheikh Trunk Control Test score,Sheikh TCT score),and homocysteine (Hcy) level before and after treatment. ResultsAfter treatment,the observation group had lower NIHSS score and Hcy level than the control group (P<0.05). The total response rate of the observation group (97.50%) was higher than that of the control group (77.50%). The scores of upper limb and lower limb FMA,MBI,BBS,and Sheikh TCT in the observation group were all higher than those in the control group (P<0.05). ConclusionThe application of Juanbitang hot compress pack combined with rehabilitation training can effectively improve the neurological function,muscle strength,motor function,daily living ability,balance ability,and trunk control ability and reduce the Hcy level in stroke patients with hemiplegia,demonstrating enhanced clinical efficacy.
3.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
4.Impact of different CT reconstruction kernel on quantitative analysis of small pulmonary vessels in chronic obstructive pulmonary disease and high-risk patients
He CHEN ; Shuzhu QIN ; Yanyan XU ; Xiaoxia REN ; Sheng XIE ; Yinghao XU ; Yu ZHANG
Chinese Journal of Radiology 2025;59(8):894-899
Objective:To investigate the impact of different CT reconstruction kernels on the quantitative analysis of small pulmonary vessels in patients with chronic obstructive pulmonary disease (COPD) and high-risk patients.Methods:This study was a cross-sectional study. Clinical and imaging data of 73 COPD and high-risk patients visiting the China-Japan Friendship Hospital between March and April 2024 were retrospectively analyzed. All patients underwent high-resolution CT of the chest and pulmonary function tests, with the ratio of forced expiratory volume in one second to forced vital capacity (FEV 1/FVC) obtained. The raw CT data were reconstructed using different kernels: the FC86 group used the adaptive iterative dose reduction(AIDR) 3D standard lung sharp reconstruction algorithm, the FC18 group used the AIDR 3D standard Body standard reconstruction algorithm, the advanced intelligent clear-IQ engine(AiCE) Lung group used the AiCE deep learning reconstruction algorithm for lung, and the AiCE Body group used the AiCE deep learning reconstruction algorithm for body. Image signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image noise were calculated. The pulmonary vessel segmentation & Measurement software was used to segment and extract pulmonary arteries and veins of four groups in thin-slice whole-lung CT imaging, obtaining the ratio of small pulmonary arteries (%V artery<5) and the ratio of small pulmonary veins (%V vein<5). The One-way repeated measures ANOVA or Friedman test was used to compare the differences in SNR, CNR, image noise, %V artery<5, and %V vein<5 among the four groups, followed by Bonferroni post hoc or Bonferroni-Dunn test with P-value correction to analysis differences between subgroups. The correlations between %V artery<5 and FEV 1/FVC, as well as between %V vein<5 and FEV 1/FVC were analyzed using Spearman rank correlation analysis in all four groups. Results:The overall differences in image noise, SNR, and CNR in the AiCE Lung, AiCE Body, FC18, and FC86 groups were statistically significant ( P<0.001). Except for the difference in CNR values between the AiCE Lung group and the FC18 group, which was not statistically significant ( P=0.192), all differences were statistically significant ( P<0.016 7). The overall differences in %V artery<5 values and %V vein<5 values in the AiCE Lung, AiCE Body, FC18, and FC86 groups were statistically significant ( P<0.001). The %V artery<5 and %V vein<5 values in the FC18 group were lower than those in the AiCE Lung, AiCE Body, and FC86 groups ( P<0.016 7), and the rest of the differences were not statistically significant ( P>0.016 7). %V artery<5 and %V vein<5 were positively correlated with FEV 1/FVC in all 4 groups ( P<0.05), with the highest correlation coefficient between %V vein<5 and FEV 1/FVC in the AiCE Body group ( r=0.501, P=0.001). Conclusions:DLR-AiCE-based kernel reconstruction optimizes image quality and significantly affects the results of quantitative parameters of small pulmonary vessels. The reconstruction kernel prioritized for quantitative analysis of small vessels within the lungs in COPD based on the CT scanner in this study is AiCE Body.
5.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
6.Traditional Chinese Medicine Treats Sepsis by Regulating PI3K/Akt Pathway: A Review
Zhu LIU ; Jiawei WANG ; Jing YAN ; Jinchan PENG ; Mingyao XU ; Liqun LI ; Sheng XIE
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(2):314-322
Sepsis is a systemic inflammatory response syndrome caused by the invasion of pathogenic microorganisms such as bacteria. In addition to the manifestations of systemic inflammatory response syndrome and primary infection lesions, critical cases often have manifestations of organ hypoperfusion. The morbidity and mortality of sepsis have remained high in recent years, which seriously affect the quality of life of the patients. The pathogenesis of sepsis is complicated, in which uncontrollable inflammation is a key mechanism. The phosphatidylinositol 3-kinase/protein kinase B (PI3K/Akt) signaling pathway plays a key role in mediating inflammation in sepsis. The available therapies of sepsis mainly include resuscitation, anti-infection, vasoactive drugs, intensive insulin therapy, and organ support, which show limited effects of reducing the mortality. Therefore, finding new therapeutic drugs is a key problem to be solved in the clinical treatment of sepsis. In recent years, studies have shown that traditional Chinese medicine (TCM) can regulate the PI3K/Akt pathway via multiple pathways, multiple effects, and multiple targets to inhibit inflammation and curb the occurrence and development of sepsis, which has gradually become a hot spot in the prevention and treatment of sepsis. Moreover, studies have suggested that TCM has unique advantages in the treatment of sepsis. TCM can regulate the PI3K/Akt signaling pathway to inhibit inflammation, reduce oxidative stress, and control apoptosis in the prevention and treatment of sepsis. Despite the research progress, a systematic review remains to be performed regarding the TCM treatment of sepsis by regulating the PI3K/Akt signaling pathway. After reviewing relevant papers published in recent years, this study systematically summarizes the relationship between PI3K/Akt pathway and sepsis and the role of TCM in the treatment of sepsis, aiming to provide new ideas for the potential treatment of sepsis and the development of new drugs.
7.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
8.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
9.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
10.Impact of different CT reconstruction kernel on quantitative analysis of small pulmonary vessels in chronic obstructive pulmonary disease and high-risk patients
He CHEN ; Shuzhu QIN ; Yanyan XU ; Xiaoxia REN ; Sheng XIE ; Yinghao XU ; Yu ZHANG
Chinese Journal of Radiology 2025;59(8):894-899
Objective:To investigate the impact of different CT reconstruction kernels on the quantitative analysis of small pulmonary vessels in patients with chronic obstructive pulmonary disease (COPD) and high-risk patients.Methods:This study was a cross-sectional study. Clinical and imaging data of 73 COPD and high-risk patients visiting the China-Japan Friendship Hospital between March and April 2024 were retrospectively analyzed. All patients underwent high-resolution CT of the chest and pulmonary function tests, with the ratio of forced expiratory volume in one second to forced vital capacity (FEV 1/FVC) obtained. The raw CT data were reconstructed using different kernels: the FC86 group used the adaptive iterative dose reduction(AIDR) 3D standard lung sharp reconstruction algorithm, the FC18 group used the AIDR 3D standard Body standard reconstruction algorithm, the advanced intelligent clear-IQ engine(AiCE) Lung group used the AiCE deep learning reconstruction algorithm for lung, and the AiCE Body group used the AiCE deep learning reconstruction algorithm for body. Image signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image noise were calculated. The pulmonary vessel segmentation & Measurement software was used to segment and extract pulmonary arteries and veins of four groups in thin-slice whole-lung CT imaging, obtaining the ratio of small pulmonary arteries (%V artery<5) and the ratio of small pulmonary veins (%V vein<5). The One-way repeated measures ANOVA or Friedman test was used to compare the differences in SNR, CNR, image noise, %V artery<5, and %V vein<5 among the four groups, followed by Bonferroni post hoc or Bonferroni-Dunn test with P-value correction to analysis differences between subgroups. The correlations between %V artery<5 and FEV 1/FVC, as well as between %V vein<5 and FEV 1/FVC were analyzed using Spearman rank correlation analysis in all four groups. Results:The overall differences in image noise, SNR, and CNR in the AiCE Lung, AiCE Body, FC18, and FC86 groups were statistically significant ( P<0.001). Except for the difference in CNR values between the AiCE Lung group and the FC18 group, which was not statistically significant ( P=0.192), all differences were statistically significant ( P<0.016 7). The overall differences in %V artery<5 values and %V vein<5 values in the AiCE Lung, AiCE Body, FC18, and FC86 groups were statistically significant ( P<0.001). The %V artery<5 and %V vein<5 values in the FC18 group were lower than those in the AiCE Lung, AiCE Body, and FC86 groups ( P<0.016 7), and the rest of the differences were not statistically significant ( P>0.016 7). %V artery<5 and %V vein<5 were positively correlated with FEV 1/FVC in all 4 groups ( P<0.05), with the highest correlation coefficient between %V vein<5 and FEV 1/FVC in the AiCE Body group ( r=0.501, P=0.001). Conclusions:DLR-AiCE-based kernel reconstruction optimizes image quality and significantly affects the results of quantitative parameters of small pulmonary vessels. The reconstruction kernel prioritized for quantitative analysis of small vessels within the lungs in COPD based on the CT scanner in this study is AiCE Body.

Result Analysis
Print
Save
E-mail