1.Study on protective effect of arbutin in yam on acute lung injury and its metabolic regulation mechanism.
Kai-Li YE ; Meng-Nan ZENG ; Feng-Xiao HAO ; Peng-Li GUO ; Yu-Han ZHANG ; Wei-Sheng FENG ; Xiao-Ke ZHENG
China Journal of Chinese Materia Medica 2025;50(15):4100-4109
This study investigated the protective effect of arbutin(Arb) in yam on lipopolysaccharide(LPS)-induced acute lung injury(ALI) in a mouse model and revealed its possible mechanism of action by metabolomics technology, providing a theoretical basis for clinical treatment of ALI. SPF BALB/c mice were randomly divided into normal control group, model group, resveratrol(Rv)-positive control group, Arb low-dose(15 mg·kg~(-1)) group, and Arb high-dose(30 mg·kg~(-1)) group. The LPS-induced ALI model was established in all groups except the normal control group. Hematoxylin-eosin(HE) staining, TUNEL staining, and WBP whole-body non-invasive pulmonary function testing were used to evaluate the degree of lung tissue damage and lung function changes. Enzyme-linked immunosorbent assay(ELISA) was used to detect the level of inflammatory factors in lung tissue. Flow cytometry was used to analyze the M1/M2 polarization status of macrophages in lung tissue. Western blot was used to detect the expression levels of the TLR4 signaling pathway and related apoptotic proteins. Liquid chromatograph-mass spectrometer(LC-MS) metabolomics was used to analyze the changes in serum metabolic profile after Arb intervention. The results showed that Arb pretreatment significantly alleviated LPS-induced lung tissue injury, improved lung function, reduced the levels of pro-inflammatory factors(IL-6, TNF-α, IL-18, and IL-1β), and regulated the polarization status of M1/M2 macrophages. In addition, Arb inhibited the activation of the TLR4 signaling pathway, reduced the expression of pro-apoptotic proteins such as Bax, caspase-3, and caspase-9, up-regulated the level of Bcl-2 protein, and inhibited apoptosis of lung cells. Metabolomic analysis showed that Arb significantly improved LPS-induced metabolic abnormalities, mainly involving key pathways such as galactose metabolism, phenylalanine metabolism, and lipid metabolism. In summary, Arb can significantly reduce LPS-induced ALI by regulating the release of inflammatory factors, inhibiting the activation of the TLR4 signaling pathway, improving metabolic disorders, and regulating macrophage polarization, indicating that Arb has potential clinical application value.
Animals
;
Acute Lung Injury/chemically induced*
;
Mice
;
Mice, Inbred BALB C
;
Arbutin/administration & dosage*
;
Male
;
Toll-Like Receptor 4/immunology*
;
Apoptosis/drug effects*
;
Lung/metabolism*
;
Signal Transduction/drug effects*
;
Protective Agents/administration & dosage*
;
Humans
;
Macrophages/immunology*
;
Drugs, Chinese Herbal/administration & dosage*
2.Development of intelligent equipment for rapid microbial detection of Atractylodis Macrocephalae Rhizoma decoction pieces based on measurement technology for traditional Chinese medicine manufacturing.
Yang LIU ; Wu-Zhen QI ; Yu-Tong WU ; Shan-Xi ZHU ; Xiao-Jun ZHAO ; Qia-Tong XIE ; Yu-Feng GUO ; Jing ZHAO ; Nan LI ; Shi-Jun WANG ; Qi-Hui SUN ; Zhi-Sheng WU
China Journal of Chinese Materia Medica 2025;50(16):4610-4618
Microbial detection and control of traditional Chinese medicine(TCM) decoction pieces are crucial for the quality control of TCM preparations. It is also a key area of research in the measurement technology and equipment development for TCM manufacturing. Guided by TCM manufacturing measurement methodologies, this study presented a design of a novel portable microbial detection device, using Atractylodis Macrocephalae Rhizoma decoction pieces as a demonstration. Immunomagnetic separation technology was employed for specific isolation and labeling of target microorganisms. Enzymatic signal amplification was utilized to convert weak biological signals into colorimetric signals, constructing an optical biosensor. A self-developed smartphone APP was further applied to analyze the colorimetric signals and quantify target concentrations. A portable and automated detection system based on Arduino microcontroller was developed to automatically perform target microbial separation/extraction, as well as mimetic enzyme labeling and catalytic reactions. The developed equipment specifically focuses on the rapid and quantitative microbial analysis of TCM active pharmaceutical ingredients, intermediates in TCM manufacturing, and final TCM products. Experimental results demonstrate that the equipment could detect Salmonella in samples within 2 h, with a detection limit as low as 5.1 × 10~3 CFU·mL~(-1). The equipment enables the rapid detection of microorganisms in TCM decoction pieces, providing a potential technical solution for on-site rapid screening of microbial contamination indicators in TCM. It has broad application prospects in measurement technology for TCM manufacturing and offers strong technical support for the modernization, industrialization, and intelligent development of TCM.
Drugs, Chinese Herbal/analysis*
;
Atractylodes/microbiology*
;
Rhizome/microbiology*
;
Biosensing Techniques/methods*
;
Medicine, Chinese Traditional
;
Colorimetry/instrumentation*
;
Quality Control
3.Design of detection gloves for orthopedic manipulation
Liu-peng SHI ; Bin SHI ; Sheng-nan CAO ; Ji-qing WANG ; Liang-yu XIE ; Guo-dong SUN
Chinese Medical Equipment Journal 2025;46(7):27-33
Objective To design a pairs of detection gloves for orthopedic manipulation to solve the problems of orthopedic manipulation in accurate,visual and quantitative description and reproduction in teaching.Methods The orthopedic manipulation detection gloves were mainly composed of a detection body worn on the hands,a main control module and a data visualization system.The detection body was made of multi-layer flexible materials such as rubber,cotton and non-woven fabrics,which integrated inertial sensors,pressure sensors and a data acquisition device;the main control module consisted of a filter circuit,an A/D converter(MCP3008)and a main controller(ARM-STM32 microcontroller);the data visualization system was designed based on the Unity 3D platform.Results The orthopedic manipulation detection gloves effectively detected the rotation angle of the knuckle during the orthopedic process with a high accuracy rate.Conclusion The orthopedic manipulation detection gloves can quantitatively display the abstract orthopedic manipulation,and can provide support for intelligent orthopedic teaching and orthopedic manipulation optimization.[Chinese Medical Equipment Journal,2025,46(7):27-33]
4.Self-developed real-time three-dimensional intracardiac echocardiography system
Jing WANG ; Dongyu ZHANG ; Nan WU ; Zhanbo HAN ; Sheng GUO ; Jian QI ; Guoliang WU ; Chuhao YIN ; Dong ZHANG
Chinese Journal of Medical Imaging Technology 2025;41(10):1653-1658
Objective To observe the performance and safety of self-developed real-time three-dimensional intracardiac echocardiography(ICE)system(system).Methods The self-developed system was constructed using disposable sterile real-time three-dimensional ICE catheter(catheter)and multifunctional cart-mounted digital ultrasound imaging host(ultrasound host).The diameter of catheter was 10F,with effective length of 90 cm and two-dimensional array transducer array(840 elements)integrated at tip.The ultrasound host was connected to the catheter through matching connector.The performance of this system was evaluated with self-made experimental equipment and standard phantom,and live animal experiment was performed to observe its safety and imaging quality.Results The maximum imaging depth of this system was ≥60 mm.Its axial resolution was ≤1 mm and lateral resolution was ≤1 mm within the depth of 40 mm,the horizontal and vertical geometric position accuracy errors were ≤10%and ≤5%,respectively,while the image geometric distortion was ≤10%,and the measurement volume error was ≤30%.The catheter was successfully inserted into right atrium of pig through femoral vein under ultrasound guidance,smoothly passing through the vascular pathway without any bending or jamming with good controllability.The cardiac images of this system were clear,which completely displayed cardiac chamber structures,and the image resolution met diagnostic requirement.No injury related to interventional procedures was found in laboratory tests nor anatomical results.Conclusion The self-developed ICE system was stable and safe,and initial results showed it could meet clinical application expectations.
5.Water extract of Rehmannia glutinosa improves bleomycin-induced pulmonary fibrosis in mice and its metabolic mechanism
Zi-yu ZHANG ; Meng-nan ZENG ; Peng-li GUO ; Yu-han ZHANG ; Xiang-da LI ; Yan-xing WU ; Shuang-ying FU ; Zi-chang LIAN ; Wei-sheng FENG ; Xiao-ke ZHENG
Chinese Pharmacological Bulletin 2025;41(12):2315-2325
Aim To investigate the intervention effect of Rehmannia radix water extract on bleomycin(BLM)-induced pulmonary fibrosis in mice combined with metabolomics and to reveal the potential mechanism,in order to provide new ideas for clinical treatment of pul-monary fibrosis.Methods Male C57BL/6N mice were randomly divided into the control group,model group,pirfenidone group(positive control,PFD,270 mg·kg-1),and low dose(DH-L,4.55 g·kg-1)group,medium dose(DH-M,9.1 g·kg-1)group and high dose(DH-H,18.2 g·kg-1)group of Rehman-nia.Except for the control group,BLM(5 mg·kg-1)was instilled into the trachea to establish the model of pulmonary fibrosis in the other groups.The survival rate,lung index and blood oxygen saturation of mice in each group were evaluated.HE and Masson staining were used to observe the pathological changes of lung tissue.WBP was used to detect lung function.Flow cytometry was used to detect the apoptosis of primary lung cells,ROS and immune cells.ELISA was used to detect the levels of fibrosis markers and inflammatory factors(α-SMA,collagen Ⅰ,collagen Ⅲ,TGF-β1,TNF-α,IL-1 β,and IL-6).Biochemical method was employed to detect the contents of GSH-Px,T-SOD and MDA.Liquid chromatograph mass spectrometer(LC-MS)metabolomics was used to analyze the changes of serum metabolic profile.Results Water extract of Re-hmannia significantly increased the survival rate,oxy-gen saturation and lung function of mice with pulmona-ry fibrosis,reduced the lung coefficient,ameliorated pathological damage and collagen deposition in lung tissue,reduced the levels of apoptosis and oxidative stress,and down-regulated the levels of inflammatory factors in lung tissue.It regulated the levels of metabo-lites such as bile acid metabolism,sphingolipid metabo-lism,and unsaturated fatty acid metabolism.Conclu-sions Water extract of Rehmannia inhibits lung injury and collagen deposition in mice with pulmonary fibrosis by inhibiting inflammatory response,which may be a-chieved by regulating the levels of inflammatory factors through the metabolic pathways of bile acid and sphin-golipid.
6.Water extract of Rehmannia glutinosa improves bleomycin-induced pulmonary fibrosis in mice and its metabolic mechanism
Zi-yu ZHANG ; Meng-nan ZENG ; Peng-li GUO ; Yu-han ZHANG ; Xiang-da LI ; Yan-xing WU ; Shuang-ying FU ; Zi-chang LIAN ; Wei-sheng FENG ; Xiao-ke ZHENG
Chinese Pharmacological Bulletin 2025;41(12):2315-2325
Aim To investigate the intervention effect of Rehmannia radix water extract on bleomycin(BLM)-induced pulmonary fibrosis in mice combined with metabolomics and to reveal the potential mechanism,in order to provide new ideas for clinical treatment of pul-monary fibrosis.Methods Male C57BL/6N mice were randomly divided into the control group,model group,pirfenidone group(positive control,PFD,270 mg·kg-1),and low dose(DH-L,4.55 g·kg-1)group,medium dose(DH-M,9.1 g·kg-1)group and high dose(DH-H,18.2 g·kg-1)group of Rehman-nia.Except for the control group,BLM(5 mg·kg-1)was instilled into the trachea to establish the model of pulmonary fibrosis in the other groups.The survival rate,lung index and blood oxygen saturation of mice in each group were evaluated.HE and Masson staining were used to observe the pathological changes of lung tissue.WBP was used to detect lung function.Flow cytometry was used to detect the apoptosis of primary lung cells,ROS and immune cells.ELISA was used to detect the levels of fibrosis markers and inflammatory factors(α-SMA,collagen Ⅰ,collagen Ⅲ,TGF-β1,TNF-α,IL-1 β,and IL-6).Biochemical method was employed to detect the contents of GSH-Px,T-SOD and MDA.Liquid chromatograph mass spectrometer(LC-MS)metabolomics was used to analyze the changes of serum metabolic profile.Results Water extract of Re-hmannia significantly increased the survival rate,oxy-gen saturation and lung function of mice with pulmona-ry fibrosis,reduced the lung coefficient,ameliorated pathological damage and collagen deposition in lung tissue,reduced the levels of apoptosis and oxidative stress,and down-regulated the levels of inflammatory factors in lung tissue.It regulated the levels of metabo-lites such as bile acid metabolism,sphingolipid metabo-lism,and unsaturated fatty acid metabolism.Conclu-sions Water extract of Rehmannia inhibits lung injury and collagen deposition in mice with pulmonary fibrosis by inhibiting inflammatory response,which may be a-chieved by regulating the levels of inflammatory factors through the metabolic pathways of bile acid and sphin-golipid.
7.Self-developed real-time three-dimensional intracardiac echocardiography system
Jing WANG ; Dongyu ZHANG ; Nan WU ; Zhanbo HAN ; Sheng GUO ; Jian QI ; Guoliang WU ; Chuhao YIN ; Dong ZHANG
Chinese Journal of Medical Imaging Technology 2025;41(10):1653-1658
Objective To observe the performance and safety of self-developed real-time three-dimensional intracardiac echocardiography(ICE)system(system).Methods The self-developed system was constructed using disposable sterile real-time three-dimensional ICE catheter(catheter)and multifunctional cart-mounted digital ultrasound imaging host(ultrasound host).The diameter of catheter was 10F,with effective length of 90 cm and two-dimensional array transducer array(840 elements)integrated at tip.The ultrasound host was connected to the catheter through matching connector.The performance of this system was evaluated with self-made experimental equipment and standard phantom,and live animal experiment was performed to observe its safety and imaging quality.Results The maximum imaging depth of this system was ≥60 mm.Its axial resolution was ≤1 mm and lateral resolution was ≤1 mm within the depth of 40 mm,the horizontal and vertical geometric position accuracy errors were ≤10%and ≤5%,respectively,while the image geometric distortion was ≤10%,and the measurement volume error was ≤30%.The catheter was successfully inserted into right atrium of pig through femoral vein under ultrasound guidance,smoothly passing through the vascular pathway without any bending or jamming with good controllability.The cardiac images of this system were clear,which completely displayed cardiac chamber structures,and the image resolution met diagnostic requirement.No injury related to interventional procedures was found in laboratory tests nor anatomical results.Conclusion The self-developed ICE system was stable and safe,and initial results showed it could meet clinical application expectations.
8.Design of detection gloves for orthopedic manipulation
Liu-peng SHI ; Bin SHI ; Sheng-nan CAO ; Ji-qing WANG ; Liang-yu XIE ; Guo-dong SUN
Chinese Medical Equipment Journal 2025;46(7):27-33
Objective To design a pairs of detection gloves for orthopedic manipulation to solve the problems of orthopedic manipulation in accurate,visual and quantitative description and reproduction in teaching.Methods The orthopedic manipulation detection gloves were mainly composed of a detection body worn on the hands,a main control module and a data visualization system.The detection body was made of multi-layer flexible materials such as rubber,cotton and non-woven fabrics,which integrated inertial sensors,pressure sensors and a data acquisition device;the main control module consisted of a filter circuit,an A/D converter(MCP3008)and a main controller(ARM-STM32 microcontroller);the data visualization system was designed based on the Unity 3D platform.Results The orthopedic manipulation detection gloves effectively detected the rotation angle of the knuckle during the orthopedic process with a high accuracy rate.Conclusion The orthopedic manipulation detection gloves can quantitatively display the abstract orthopedic manipulation,and can provide support for intelligent orthopedic teaching and orthopedic manipulation optimization.[Chinese Medical Equipment Journal,2025,46(7):27-33]
9.Direct Determination of 23 Kinds of Per-and Polyfluoroalkyl Substances in Crude Plant Extracts by Liquid Chromatography-Tandem Mass Spectrometry Coupled with Online Solid Phase Extraction
Nan SHEN ; Tong-Zhu HAN ; Can-Can SHENG ; Xiu-Ping HE ; Jun-Hui CHEN ; Chen-Guang LIU ; Xian-Guo LI
Chinese Journal of Analytical Chemistry 2024;52(2):286-295,后插1-后插5
A new method for simultaneous determination of 23 kinds of per-and polyfluoroalkyl substances(PFASs)(13 kinds of perfluoro carboxylic acids,4 kinds of perfluoro sulfonic acids,and 6 kinds of new substitutes)in plant leaf tissue by ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)using automatic online solid phase extraction(SPE)to remove the matrix interference components in plant crude extracts was developed.The plant leaf samples were extracted twice with 1%formic acid-methanol solution,then evaporated to dry,redissolved with 70%methanol solution,and directly injected for analysis.After 23 kinds of target PFASs were purified automatically by online SPE with a WAX column,the six-way valve was switched to rinse PFASs onto an alkaline mobile phase system-compatible C18 analytical column.Then,the 23 kinds of target PFASs were separated within 16 min by gradient elution using a binary mobile phase system of methanol/water(Containing 0.4%ammonium hydroxide).Tandem mass spectrometry was performed in multiple reaction monitoring(MRM)mode for online detection of various PFASs,and quantification was carried out by internal standard method.The results of the method validation showed that satisfactory average recoveries of 23 kinds of PFASs in plant leaf samples(64.2%-125.5%),precision(relative standard deviations(RSDs)of 0.7%-12.8%),linearity(R2>0.990),and sensitivity(the detection limits(S/N=3)were in the range of 0.02-0.50 μg/kg)were achieved.Finally,this method was used to detect PFASs in the marine green tide algae(Enteromorpha prolifera)and several tree leaves,and a total of 6 kinds of PFASs were detected,in which PFBA was the main contaminant.Compared with the reported offline SPE methods,the proposed online SPE technique significantly simplified the sample pretreatment process and provided an automatic,simple,and environment-friendly method for the routine monitoring of legacy and emerging PFASs in plant tissues.
10.A new furan α -butenolactones from Alisma orientale and their potential antifibrotic activities
Deng-hui ZHU ; Peng-li GUO ; Si-qi TAO ; Jing-ke ZHANG ; Meng-nan ZENG ; Xiao-ke ZHENG ; Wei-sheng FENG
Acta Pharmaceutica Sinica 2024;59(7):2058-2061
Four furan

Result Analysis
Print
Save
E-mail