1.Safety and Efficacy of Radiofrequency Ablation for Superficial Parotid Pleomorphic Adenoma
Chih-Ying LEE ; Wei-Che LIN ; Sheng-Dean LUO ; Pi-Ling CHIANG ; An-Ni LIN ; Cheng-Kang WANG ; Chun-Yuan CHAO
Korean Journal of Radiology 2025;26(5):460-470
Objective:
To retrospectively compare the safety and efficacy of ultrasound-guided radiofrequency ablation (RFA) with parotidectomy for superficial pleomorphic adenoma (PA).
Materials and Methods:
From March 2022 to October 2023, 88 patients diagnosed with superficial parotid PA underwent either RFA (n = 12; mean age, 47.1 years) or parotidectomy (n = 76; mean age, 47.8 years). Patients in the RFA group were matched to those in the surgery group in a 1:1 ratio using propensity scores based on age, sex, tumor volume, diameter, location, and comorbidities. Ultrasound characteristics, cosmetic scores (0–4), numerical rating scale scores (0–10), and complications were assessed before the procedures and at 1-, 3-, and 6-month follow-ups. Outcomes were compared between baseline and follow-up in the RFA group and between the RFA and surgery groups.
Results:
In the RFA group, significant reductions in tumor volume were observed between baseline (median, 2.02 cm 3 ) and the 1-month follow-up (median, 1.21 cm 3 ; P = 0.015), between the 1-month and 3-month follow-ups (median, 0.53 cm 3 ; P= 0.002), and between the 3- and 6-month follow-ups (median, 0.23 cm 3 ; P = 0.003). The volume reduction ratios at 1, 3, and 6 months were 39.7%, 79.9%, and 88.0%, respectively. The cosmetic score was significantly lower at 3- and 6-month followup compared to baseline (median 1 and 1 vs. 4, P = 0.04). The numerical rating scale scores did not differ significantly from baseline throughout follow-up. In the propensity score-matched analysis (12 patients per group), RFA was associated with a shorter median procedure time (61.5 vs. 253.3 minutes; P < 0.001), shorter hospital stay (0 vs. 4 days; P < 0.001), and lower cost (1859.9 vs. 3512.4 USD; P < 0.001) than parotidectomy, with no significant difference in overall complication rates (33.3% [4/12] vs. 41.7% [5/12]; P = 1.000).
Conclusion
RFA may be a safe and effective alternative to surgery for superficial parotid PA, offering a shorter median procedure time, shorter hospital stay, and lower costs.
2.Chemical consitituents and hypoglycemic activity of Qinhuai No. 1 Rehmannia glutinosa
Meng YANG ; Zhi-you HAO ; Xiao-lan WANG ; Chao-yuan XIAO ; Jun-yang ZHANG ; Shi-qi ZHOU ; Xiao-ke ZHENG ; Wei-sheng FENG
Acta Pharmaceutica Sinica 2025;60(1):205-210
Eight compounds were isolated and purified from the ethyl acetate part of 70% acetone extract of
3.Safety and Efficacy of Radiofrequency Ablation for Superficial Parotid Pleomorphic Adenoma
Chih-Ying LEE ; Wei-Che LIN ; Sheng-Dean LUO ; Pi-Ling CHIANG ; An-Ni LIN ; Cheng-Kang WANG ; Chun-Yuan CHAO
Korean Journal of Radiology 2025;26(5):460-470
Objective:
To retrospectively compare the safety and efficacy of ultrasound-guided radiofrequency ablation (RFA) with parotidectomy for superficial pleomorphic adenoma (PA).
Materials and Methods:
From March 2022 to October 2023, 88 patients diagnosed with superficial parotid PA underwent either RFA (n = 12; mean age, 47.1 years) or parotidectomy (n = 76; mean age, 47.8 years). Patients in the RFA group were matched to those in the surgery group in a 1:1 ratio using propensity scores based on age, sex, tumor volume, diameter, location, and comorbidities. Ultrasound characteristics, cosmetic scores (0–4), numerical rating scale scores (0–10), and complications were assessed before the procedures and at 1-, 3-, and 6-month follow-ups. Outcomes were compared between baseline and follow-up in the RFA group and between the RFA and surgery groups.
Results:
In the RFA group, significant reductions in tumor volume were observed between baseline (median, 2.02 cm 3 ) and the 1-month follow-up (median, 1.21 cm 3 ; P = 0.015), between the 1-month and 3-month follow-ups (median, 0.53 cm 3 ; P= 0.002), and between the 3- and 6-month follow-ups (median, 0.23 cm 3 ; P = 0.003). The volume reduction ratios at 1, 3, and 6 months were 39.7%, 79.9%, and 88.0%, respectively. The cosmetic score was significantly lower at 3- and 6-month followup compared to baseline (median 1 and 1 vs. 4, P = 0.04). The numerical rating scale scores did not differ significantly from baseline throughout follow-up. In the propensity score-matched analysis (12 patients per group), RFA was associated with a shorter median procedure time (61.5 vs. 253.3 minutes; P < 0.001), shorter hospital stay (0 vs. 4 days; P < 0.001), and lower cost (1859.9 vs. 3512.4 USD; P < 0.001) than parotidectomy, with no significant difference in overall complication rates (33.3% [4/12] vs. 41.7% [5/12]; P = 1.000).
Conclusion
RFA may be a safe and effective alternative to surgery for superficial parotid PA, offering a shorter median procedure time, shorter hospital stay, and lower costs.
4.Safety and Efficacy of Radiofrequency Ablation for Superficial Parotid Pleomorphic Adenoma
Chih-Ying LEE ; Wei-Che LIN ; Sheng-Dean LUO ; Pi-Ling CHIANG ; An-Ni LIN ; Cheng-Kang WANG ; Chun-Yuan CHAO
Korean Journal of Radiology 2025;26(5):460-470
Objective:
To retrospectively compare the safety and efficacy of ultrasound-guided radiofrequency ablation (RFA) with parotidectomy for superficial pleomorphic adenoma (PA).
Materials and Methods:
From March 2022 to October 2023, 88 patients diagnosed with superficial parotid PA underwent either RFA (n = 12; mean age, 47.1 years) or parotidectomy (n = 76; mean age, 47.8 years). Patients in the RFA group were matched to those in the surgery group in a 1:1 ratio using propensity scores based on age, sex, tumor volume, diameter, location, and comorbidities. Ultrasound characteristics, cosmetic scores (0–4), numerical rating scale scores (0–10), and complications were assessed before the procedures and at 1-, 3-, and 6-month follow-ups. Outcomes were compared between baseline and follow-up in the RFA group and between the RFA and surgery groups.
Results:
In the RFA group, significant reductions in tumor volume were observed between baseline (median, 2.02 cm 3 ) and the 1-month follow-up (median, 1.21 cm 3 ; P = 0.015), between the 1-month and 3-month follow-ups (median, 0.53 cm 3 ; P= 0.002), and between the 3- and 6-month follow-ups (median, 0.23 cm 3 ; P = 0.003). The volume reduction ratios at 1, 3, and 6 months were 39.7%, 79.9%, and 88.0%, respectively. The cosmetic score was significantly lower at 3- and 6-month followup compared to baseline (median 1 and 1 vs. 4, P = 0.04). The numerical rating scale scores did not differ significantly from baseline throughout follow-up. In the propensity score-matched analysis (12 patients per group), RFA was associated with a shorter median procedure time (61.5 vs. 253.3 minutes; P < 0.001), shorter hospital stay (0 vs. 4 days; P < 0.001), and lower cost (1859.9 vs. 3512.4 USD; P < 0.001) than parotidectomy, with no significant difference in overall complication rates (33.3% [4/12] vs. 41.7% [5/12]; P = 1.000).
Conclusion
RFA may be a safe and effective alternative to surgery for superficial parotid PA, offering a shorter median procedure time, shorter hospital stay, and lower costs.
5.Safety and Efficacy of Radiofrequency Ablation for Superficial Parotid Pleomorphic Adenoma
Chih-Ying LEE ; Wei-Che LIN ; Sheng-Dean LUO ; Pi-Ling CHIANG ; An-Ni LIN ; Cheng-Kang WANG ; Chun-Yuan CHAO
Korean Journal of Radiology 2025;26(5):460-470
Objective:
To retrospectively compare the safety and efficacy of ultrasound-guided radiofrequency ablation (RFA) with parotidectomy for superficial pleomorphic adenoma (PA).
Materials and Methods:
From March 2022 to October 2023, 88 patients diagnosed with superficial parotid PA underwent either RFA (n = 12; mean age, 47.1 years) or parotidectomy (n = 76; mean age, 47.8 years). Patients in the RFA group were matched to those in the surgery group in a 1:1 ratio using propensity scores based on age, sex, tumor volume, diameter, location, and comorbidities. Ultrasound characteristics, cosmetic scores (0–4), numerical rating scale scores (0–10), and complications were assessed before the procedures and at 1-, 3-, and 6-month follow-ups. Outcomes were compared between baseline and follow-up in the RFA group and between the RFA and surgery groups.
Results:
In the RFA group, significant reductions in tumor volume were observed between baseline (median, 2.02 cm 3 ) and the 1-month follow-up (median, 1.21 cm 3 ; P = 0.015), between the 1-month and 3-month follow-ups (median, 0.53 cm 3 ; P= 0.002), and between the 3- and 6-month follow-ups (median, 0.23 cm 3 ; P = 0.003). The volume reduction ratios at 1, 3, and 6 months were 39.7%, 79.9%, and 88.0%, respectively. The cosmetic score was significantly lower at 3- and 6-month followup compared to baseline (median 1 and 1 vs. 4, P = 0.04). The numerical rating scale scores did not differ significantly from baseline throughout follow-up. In the propensity score-matched analysis (12 patients per group), RFA was associated with a shorter median procedure time (61.5 vs. 253.3 minutes; P < 0.001), shorter hospital stay (0 vs. 4 days; P < 0.001), and lower cost (1859.9 vs. 3512.4 USD; P < 0.001) than parotidectomy, with no significant difference in overall complication rates (33.3% [4/12] vs. 41.7% [5/12]; P = 1.000).
Conclusion
RFA may be a safe and effective alternative to surgery for superficial parotid PA, offering a shorter median procedure time, shorter hospital stay, and lower costs.
6.Safety and Efficacy of Radiofrequency Ablation for Superficial Parotid Pleomorphic Adenoma
Chih-Ying LEE ; Wei-Che LIN ; Sheng-Dean LUO ; Pi-Ling CHIANG ; An-Ni LIN ; Cheng-Kang WANG ; Chun-Yuan CHAO
Korean Journal of Radiology 2025;26(5):460-470
Objective:
To retrospectively compare the safety and efficacy of ultrasound-guided radiofrequency ablation (RFA) with parotidectomy for superficial pleomorphic adenoma (PA).
Materials and Methods:
From March 2022 to October 2023, 88 patients diagnosed with superficial parotid PA underwent either RFA (n = 12; mean age, 47.1 years) or parotidectomy (n = 76; mean age, 47.8 years). Patients in the RFA group were matched to those in the surgery group in a 1:1 ratio using propensity scores based on age, sex, tumor volume, diameter, location, and comorbidities. Ultrasound characteristics, cosmetic scores (0–4), numerical rating scale scores (0–10), and complications were assessed before the procedures and at 1-, 3-, and 6-month follow-ups. Outcomes were compared between baseline and follow-up in the RFA group and between the RFA and surgery groups.
Results:
In the RFA group, significant reductions in tumor volume were observed between baseline (median, 2.02 cm 3 ) and the 1-month follow-up (median, 1.21 cm 3 ; P = 0.015), between the 1-month and 3-month follow-ups (median, 0.53 cm 3 ; P= 0.002), and between the 3- and 6-month follow-ups (median, 0.23 cm 3 ; P = 0.003). The volume reduction ratios at 1, 3, and 6 months were 39.7%, 79.9%, and 88.0%, respectively. The cosmetic score was significantly lower at 3- and 6-month followup compared to baseline (median 1 and 1 vs. 4, P = 0.04). The numerical rating scale scores did not differ significantly from baseline throughout follow-up. In the propensity score-matched analysis (12 patients per group), RFA was associated with a shorter median procedure time (61.5 vs. 253.3 minutes; P < 0.001), shorter hospital stay (0 vs. 4 days; P < 0.001), and lower cost (1859.9 vs. 3512.4 USD; P < 0.001) than parotidectomy, with no significant difference in overall complication rates (33.3% [4/12] vs. 41.7% [5/12]; P = 1.000).
Conclusion
RFA may be a safe and effective alternative to surgery for superficial parotid PA, offering a shorter median procedure time, shorter hospital stay, and lower costs.
7.The Application of Quantum Dots in Disease Diagnosis and Treatment
Ji-Sheng SHEN ; Li-Li QI ; Jin-Bo WANG ; Zhi-Jian KE ; Qi-Chao WANG
Progress in Biochemistry and Biophysics 2025;52(8):1917-1931
Quantum dots (QDs), nanoscale semiconductor crystals, have emerged as a revolutionary class of nanomaterials with unique optical and electrochemical properties, making them highly promising for applications in disease diagnosis and treatment. Their tunable emission spectra, long-term photostability, high quantum yield, and excellent charge carrier mobility enable precise control over light emission and efficient charge utilization, which are critical for biomedical applications. This article provides a comprehensive review of recent advancements in the use of quantum dots for disease diagnosis and therapy, highlighting their potential and the challenges involved in clinical translation. Quantum dots can be classified based on their elemental composition and structural configuration. For instance, IB-IIIA-VIA group quantum dots and core-shell structured quantum dots are among the most widely studied types. These classifications are essential for understanding their diverse functionalities and applications. In disease diagnosis, quantum dots have demonstrated remarkable potential due to their high brightness, photostability, and ability to provide precise biomarker detection. They are extensively used in bioimaging technologies, enabling high-resolution imaging of cells, tissues, and even individual biomolecules. As fluorescent markers, quantum dots facilitate cell tracking, biosensing, and the detection of diseases such as cancer, bacterial and viral infections, and immune-related disorders. Their ability to provide real-time, in vivo tracking of cellular processes has opened new avenues for early and accurate disease detection. In the realm of disease treatment, quantum dots serve as versatile nanocarriers for targeted drug delivery. Their nanoscale size and surface modifiability allow them to transport therapeutic agents to specific sites, improving drug bioavailability and reducing off-target effects. Additionally, quantum dots have shown promise as photosensitizers in photodynamic therapy (PDT). When exposed to specific wavelengths of light, quantum dots interact with oxygen molecules to generate reactive oxygen species (ROS), which can selectively destroy malignant cells, vascular lesions, and microbial infections. This targeted approach minimizes damage to healthy tissues, making PDT a promising strategy for treating complex diseases. Despite these advancements, the translation of quantum dots from research to clinical application faces significant challenges. Issues such as toxicity, stability, and scalability in industrial production remain major obstacles. The potential toxicity of quantum dots, particularly to vital organs, has raised concerns about their long-term safety. Researchers are actively exploring strategies to mitigate these risks, including surface modification, coating, and encapsulation techniques, which can enhance biocompatibility and reduce toxicity. Furthermore, improving the stability of quantum dots under physiological conditions is crucial for their effective use in biomedical applications. Advances in surface engineering and the development of novel encapsulation methods have shown promise in addressing these stability concerns. Industrial production of quantum dots also presents challenges, particularly in achieving consistent quality and scalability. Recent innovations in synthesis techniques and manufacturing processes are paving the way for large-scale production, which is essential for their widespread adoption in clinical settings. This article provides an in-depth analysis of the latest research progress in quantum dot applications, including drug delivery, bioimaging, biosensing, photodynamic therapy, and pathogen detection. It also discusses the multiple barriers hindering their clinical use and explores potential solutions to overcome these challenges. The review concludes with a forward-looking perspective on the future directions of quantum dot research, emphasizing the need for further studies on toxicity mitigation, stability enhancement, and scalable production. By addressing these critical issues, quantum dots can realize their full potential as transformative tools in disease diagnosis and treatment, ultimately improving patient outcomes and advancing biomedical science.
8.Safety and efficacy of human umbilical cord-derived mesenchymal stem cells in COVID-19 patients: A real-world observation.
Siyu WANG ; Tao YANG ; Tiantian LI ; Lei SHI ; Ruonan XU ; Chao ZHANG ; Zerui WANG ; Ziying ZHANG ; Ming SHI ; Zhe XU ; Fu-Sheng WANG
Chinese Medical Journal 2025;138(22):2984-2992
BACKGROUND:
The effects of human umbilical cord-derived mesenchymal stem cell (UC-MSC) treatment on coronavirus disease 2019 (COVID-19) patients have been preliminarily characterized. However, real-world data on the safety and efficacy of intravenous transfusions of MSCs in hospitalized COVID-19 patients at the convalescent stage remain to be reported.
METHODS:
This was a single-arm, multicenter, real-word study in which a contemporaneous external control was included as the control group. Besides, severe and critical COVID-19 patients were considered together as the severe group, given the small number of critical patients. For a total of 110 patients, 21 moderate patients and 31 severe patients were enrolled in the MSC treatment group, while 26 moderate patients and 32 severe patients were enrolled in the control group. All patients received standard treatment. The MSC treatment patients additionally received intravenous infusions of MSCs at a dose of 4 × 10 7 cells on days 0, 3, and 6, respectively. The clinical outcomes, including adverse events (AEs), lung lesion proportion on chest computed tomography, pulmonary function, 6-min walking distance (6-MWD), clinical symptoms, and laboratory parameters, were measured on days 28, 90, 180, 270, and 360 during the follow-up visits.
RESULTS:
In patients with moderate COVID-19, MSC treatment improved pulmonary function parameters, including forced expiratory volume in the first second (FEV1) and maximum forced vital capacity (VCmax) on days 28 (FEV1, 2.75 [2.35, 3.23] vs . 2.11 [1.96, 2.35], P = 0.008; VCmax, 2.92 [2.55, 3.60] vs . 2.47 [2.18, 2.68], P = 0.041), 90 (FEV1, 2.93 [2.63, 3.27] vs . 2.38 [2.24, 2.63], P = 0.017; VCmax, 3.52 [3.02, 3.80] vs . 2.59 [2.45, 3.15], P = 0.017), and 360 (FEV1, 2.91 [2.75, 3.18] vs . 2.30 [2.16, 2.70], P = 0.019; VCmax,3.61 [3.35, 3.97] vs . 2.69 [2.56, 3.23], P = 0.036) compared with the controls. In addition, in severe patients, MSC treatment notably reduced the proportion of ground-glass lesions in the whole lung volume on day 90 ( P = 0.045) compared with the controls. No difference in the incidence of AEs was observed between the two groups. Similarly, no significant differences were found in the 6-MWD, D-dimer levels, or interleukin-6 concentrations between the MSC and control groups.
CONCLUSIONS:
Our results demonstrate the safety and potential of MSC treatment for improved lung lesions and pulmonary function in convalescent COVID-19 patients. However, comprehensive and long-term studies are required to confirm the efficacy of MSC treatment.
TRIAL REGISTRATION
Chinese Clinical Trial Registry, ChiCTR2000031430.
Humans
;
COVID-19/therapy*
;
Female
;
Male
;
Mesenchymal Stem Cell Transplantation/adverse effects*
;
Middle Aged
;
Adult
;
Umbilical Cord/cytology*
;
Mesenchymal Stem Cells/cytology*
;
SARS-CoV-2
;
Aged
;
Treatment Outcome
9.Root causes of quality changes in cultivated Chinese materia medica and countermeasures for high-quality production.
Chao-Geng LYU ; Chuan-Zhi KANG ; Ya-Li HE ; Zhi-Lai ZHAN ; Sheng WANG ; Xiu-Fu WAN ; Lan-Ping GUO
China Journal of Chinese Materia Medica 2025;50(13):3529-3535
In order to support the implementation of the Opinions on Improving the Quality of Traditional Chinese Medicine and Promoting the High-Quality Development of the Traditional Chinese Medicine Industry and fundamentally promote the high-quality development of Chinese materia medica(CMM) industry, this article analyzed the quality and safety issues arising during the transition of CMM from wild harvesting to cultivation. Root causes of these issues were identified, including changes in the habitats of medicinal plants caused by inappropriate field cultivation patterns, excessive use of chemical inputs such as fertilizers and pesticides, and shortened cultivation periods due to rising economic costs. To address the above issues, the following countermeasures and suggestions were proposed to advance the high-quality development of CMM:(1) comprehensively adjust the cultivation patterns, vigorously promote ecological cultivation of CMM, and ensure production quality and safety of CMM from the source;(2) strengthen the breeding of high-quality, stress-resistant CMM varieties, improve cultivation techniques to reduce the use of fertilizers and pesticides, and improve the quality and efficiency of ecological cultivation of CMM;(3) systematically design the production, operation, and supervision models for ecological cultivation of CMM, carry out demonstrations of "high quality with fair price", and ensure the sustainable development of ecological cultivation of CMM.
Drugs, Chinese Herbal/standards*
;
Quality Control
;
Plants, Medicinal/chemistry*
;
Plant Roots/chemistry*
;
China
;
Fertilizers/analysis*
;
Materia Medica/standards*
;
Medicine, Chinese Traditional/standards*
10.A Study of Flow Sorting Lymphocyte Subsets to Detect Epstein-Barr Virus Reactivation in Patients with Hematological Malignancies.
Hui-Ying LI ; Shen-Hao LIU ; Fang-Tong LIU ; Kai-Wen TAN ; Zi-Hao WANG ; Han-Yu CAO ; Si-Man HUANG ; Chao-Ling WAN ; Hai-Ping DAI ; Sheng-Li XUE ; Lian BAI
Journal of Experimental Hematology 2025;33(5):1468-1475
OBJECTIVE:
To analyze the Epstein-Barr virus (EBV) load in different lymphocyte subsets, as well as clinical characteristics and outcomes in patients with hematologic malignancies experiencing EBV reactivation.
METHODS:
Peripheral blood samples from patients were collected. B, T, and NK cells were isolated sorting with magnetic beads by flow cytometry. The EBV load in each subset was quantitated by real-time quantitative polymerase chain reaction (RT-qPCR). Clinical data were colleted from electronic medical records. Survival status was followed up through outpatient visits and telephone calls. Statistical analyses were performed using SPSS 25.0.
RESULTS:
A total of 39 patients with hematologic malignancies were included, among whom 35 patients had undergone allogeneic hematopoietic stem cell transplantation (allo-HSCT). The median time to EBV reactivation was 4.8 months (range: 1.7-57.1 months) after allo-HSCT. EBV was detected in B, T, and NK cells in 20 patients, in B and T cells in 11 patients, and only in B cells in 4 patients. In the 35 patients, the median EBV load in B cells was 2.19×104 copies/ml, significantly higher than that in T cells (4.00×103 copies/ml, P <0.01) and NK cells (2.85×102 copies/ml, P <0.01). Rituximab (RTX) was administered for 32 patients, resulting in EBV negativity in 32 patients with a median time of 8 days (range: 2-39 days). Post-treatment analysis of 13 patients showed EBV were all negative in B, T, and NK cells. In the four non-transplant patients, the median time to EBV reactivation was 35 days (range: 1-328 days) after diagnosis of the primary disease. EBV was detected in one or two subsets of B, T, or NK cells, but not simultaneously in all three subsets. These patients received a combination chemotherapy targeting at the primary disease, with 3 patients achieving EBV negativity, and the median time to be negative was 40 days (range: 13-75 days).
CONCLUSION
In hematologic malignancy patients after allo-HSCT, EBV reactivation commonly involves B, T, and NK cells, with a significantly higher viral load in B cells compared to T and NK cells. Rituximab is effective for EBV clearance. In non-transplant patients, EBV reactivation is restricted to one or two lymphocyte subsets, and clearance is slower, highlighting the need for prompt anti-tumor therapy.
Humans
;
Hematologic Neoplasms/virology*
;
Herpesvirus 4, Human/physiology*
;
Epstein-Barr Virus Infections
;
Hematopoietic Stem Cell Transplantation
;
Virus Activation
;
Lymphocyte Subsets/virology*
;
Flow Cytometry
;
Killer Cells, Natural/virology*
;
Male
;
Female
;
B-Lymphocytes/virology*
;
Viral Load
;
Adult
;
T-Lymphocytes/virology*
;
Middle Aged

Result Analysis