1.Study on the effectiveness and safety of a novel intravascular shock wave balloon for pre-treatment of severe coronary artery calcification lesions
Rui-tao ZHANG ; Zhen-yu TIAN ; Yong ZENG ; Guo-sheng FU ; Li XU ; Jian LIU ; Jian-ping LI ; Zhi-hui ZHANG ; Xin-qun HU ; Xiang CHENG ; Wen LU ; Ming CUI ; Yi-da TANG
Chinese Journal of Interventional Cardiology 2025;33(2):61-70
Objective To evaluate the efficacy and safety of a novel intravascular lithotripsy(IVL)balloon—Vesscrack shockwave balloon—for vascular preparation before stent implantation in patients with severe coronary artery calcification(CAC).Methods This was a prospective,single-arm,multicenter study conducted in China from June 2022 to October 2022.Patients with severe CAC were treated with the Vesscrack shockwave balloon for lesion preparation,followed by drug-eluting stent(DES)implantation.Of these,33 patients underwent optical coherence tomography(OCT).The primary endpoint was procedural success,defined as successful stent implantation with residual stenosis≤30%and the absence of in-hospital major adverse events,including cardiac death,target vessel-related myocardial infarction,or target lesion revascularization.Results A total of 170 patients[mean age:(65.9±7.9)years,116 males]were enrolled.After treatment with IVL and DES,the minimum lumen diameter increased significantly compared to baseline[(2.34±0.40)mm vs.(0.95±0.33)mm,P<0.001],the degree of stenosis was significantly reduced[(13.24±6.60)%vs.(65.18±10.59)%,P<0.001].Procedural success was achieved in 100%of cases,and device success was 98.8%.The 30-day patient-related cardiovascular clinical composite endpoint(POCE)rate was 0.0,with no target lesion failure,no confirmed or potential thrombotic events were observed.The shockwave energy generator demonstrated excellent stability and ease of use.Among the 33 patients assessed with OCT,after IVL intervention,the maximum calcified area of the lumen[(3.51±1.51)mm2 vs.(2.85±1.80)mm2,P<0.001],and the minimum lumen area within the target lesion[(3.08±1.04)mm2 vs.(2.02±0.75)mm2,P<0.001],and after DES intervention,the luminal area of the largest calcified site[(6.59±1.64)mm2 vs.(2.85±1.80)mm2,P<0.001]and the minimum luminal area within the target lesion[(6.19±1.45)mm2 vs.(2.02±0.75)mm2,P<0.001]were significantly increased,and the differences were statistically significant.Conclusions The Vesscrack shockwave balloon is effective and safe for vascular preparation in patients with severe CAC prior to stent implantation.It achieves significant calcified plaque modification,high procedural success rates,and minimal complications.
2.Development of transparent manikin and its application to surgical training on medical train
Ya-jun SONG ; Wen-gang HU ; Ming-hui YANG ; Sheng-qing LYU ; Chi-bing HUANG ; Ji-feng ZOU ; Yang LI ; Yun WANG ; Ji ZHENG
Chinese Medical Equipment Journal 2025;46(6):111-115
Objective To develop a novel type of transparent simulation manikin as a surgical training model to meet the surgical treatment demand on the medical train.Methods A transparent manikin was developed with the steps of basic data collection,motherboard design and manufacture and module production and assembly.Firstly,basic data collection was carried out with reference to standardized human anatomy and parameters.Secondly,some software such as UG NX7.5 was used to construct the motherboard of the manikin.Finally,module production and assembly were performed with the materials of acrylic,transparent rubber,silicone and hydrogel and the technology of silicone infusion.Results The transparent manikin developed had its anatomy structure close to that of the real body and high visuality for its internal and external components,which simulated a variety of war wounds and thus could be integrated with the surgical training scenarios on the medical train effectively.Conclusion The transparent manikin developed is characterized by high visuality,modularity and blood flow,and meets the demands for surgical training on the medical train.[Chinese Medical Equipment Journal,2025,46(6):111-115]
3.Application review of wearable devices in auxiliary detection and diagnosis of acute mountain sickness
Hui-quan WANG ; Shuai MA ; Guo-sheng CHEN ; Yu GUO ; Jin-han YU ; Zheng-xu YAN ; Ming-hu LIU ; Xin-min DONG
Chinese Medical Equipment Journal 2025;46(9):100-107
The pathological mechanisms and related physiological indicators of acute mountain sickness(AMS)were introduced,and the present situation of wearable devices applied in AMS auxiliary detection and diagnosis were reviewed.The challenges and future development directions of wearable devices applied in auxiliary detection and diagnosis were pointed out.[Chinese Medical Equipment Journal,2025,46(9):100-107]
4.CURRENT DISTRIBUTION OF AEDES AEGYPTI IN LEIZHOU PENINSULA,ZHANJIANG CITY,GUANGDONG PROVINCE
Rui-Peng LU ; Jin-Hua DUAN ; Yu-Wen ZHONG ; Hui DENG ; Jun WU ; Li-Ping LIU ; Wei-Xiong YIN ; Feng XING ; Hui HUANG ; Chang-Jie FU ; Zong-Jing CHEN ; Ming-Ji CHENG ; Sheng-Jun HU ; Ya-Ting CHEN ; Wen-Ting GUO ; Li-Feng LIN
Acta Parasitologica et Medica Entomologica Sinica 2025;32(1):16-21
Objective To investigate the status of population dynamics and distribution changes of Aedes aegypti in Guangdong Province.Methods Continuous monitoring was conducted from May 2018 to July 2024 in Wushi Town and Qishui Town,Leizhou City,Zhanjiang City,Guangdong Province.Additionally,a survey of the distribution of Ae.aegypti along the Leizhou Peninsula coast was carried out.Results The density of Ae.aegypti in Zhanjiang showed a gradual decline from 2018 to 2024.The last detection of adult Ae.aegypti in Wushi Town was in September 2021,and the last larva was found in October 2023.No Ae.aegypti was detected in Qishui Town during surveys from 2021 to 2024.A survey of 18 coastal villages in the Leizhou Peninsula revealed no detections of Ae.aegypti.Conclusions This study provides a basis for understanding the distribution and population density fluctuations of Ae.aegypti,assessing its invasion risk,and scientifically conducting relevant prevention and control efforts.
5.Study on the effectiveness and safety of a novel intravascular shock wave balloon for pre-treatment of severe coronary artery calcification lesions
Rui-tao ZHANG ; Zhen-yu TIAN ; Yong ZENG ; Guo-sheng FU ; Li XU ; Jian LIU ; Jian-ping LI ; Zhi-hui ZHANG ; Xin-qun HU ; Xiang CHENG ; Wen LU ; Ming CUI ; Yi-da TANG
Chinese Journal of Interventional Cardiology 2025;33(2):61-70
Objective To evaluate the efficacy and safety of a novel intravascular lithotripsy(IVL)balloon—Vesscrack shockwave balloon—for vascular preparation before stent implantation in patients with severe coronary artery calcification(CAC).Methods This was a prospective,single-arm,multicenter study conducted in China from June 2022 to October 2022.Patients with severe CAC were treated with the Vesscrack shockwave balloon for lesion preparation,followed by drug-eluting stent(DES)implantation.Of these,33 patients underwent optical coherence tomography(OCT).The primary endpoint was procedural success,defined as successful stent implantation with residual stenosis≤30%and the absence of in-hospital major adverse events,including cardiac death,target vessel-related myocardial infarction,or target lesion revascularization.Results A total of 170 patients[mean age:(65.9±7.9)years,116 males]were enrolled.After treatment with IVL and DES,the minimum lumen diameter increased significantly compared to baseline[(2.34±0.40)mm vs.(0.95±0.33)mm,P<0.001],the degree of stenosis was significantly reduced[(13.24±6.60)%vs.(65.18±10.59)%,P<0.001].Procedural success was achieved in 100%of cases,and device success was 98.8%.The 30-day patient-related cardiovascular clinical composite endpoint(POCE)rate was 0.0,with no target lesion failure,no confirmed or potential thrombotic events were observed.The shockwave energy generator demonstrated excellent stability and ease of use.Among the 33 patients assessed with OCT,after IVL intervention,the maximum calcified area of the lumen[(3.51±1.51)mm2 vs.(2.85±1.80)mm2,P<0.001],and the minimum lumen area within the target lesion[(3.08±1.04)mm2 vs.(2.02±0.75)mm2,P<0.001],and after DES intervention,the luminal area of the largest calcified site[(6.59±1.64)mm2 vs.(2.85±1.80)mm2,P<0.001]and the minimum luminal area within the target lesion[(6.19±1.45)mm2 vs.(2.02±0.75)mm2,P<0.001]were significantly increased,and the differences were statistically significant.Conclusions The Vesscrack shockwave balloon is effective and safe for vascular preparation in patients with severe CAC prior to stent implantation.It achieves significant calcified plaque modification,high procedural success rates,and minimal complications.
6.Development of transparent manikin and its application to surgical training on medical train
Ya-jun SONG ; Wen-gang HU ; Ming-hui YANG ; Sheng-qing LYU ; Chi-bing HUANG ; Ji-feng ZOU ; Yang LI ; Yun WANG ; Ji ZHENG
Chinese Medical Equipment Journal 2025;46(6):111-115
Objective To develop a novel type of transparent simulation manikin as a surgical training model to meet the surgical treatment demand on the medical train.Methods A transparent manikin was developed with the steps of basic data collection,motherboard design and manufacture and module production and assembly.Firstly,basic data collection was carried out with reference to standardized human anatomy and parameters.Secondly,some software such as UG NX7.5 was used to construct the motherboard of the manikin.Finally,module production and assembly were performed with the materials of acrylic,transparent rubber,silicone and hydrogel and the technology of silicone infusion.Results The transparent manikin developed had its anatomy structure close to that of the real body and high visuality for its internal and external components,which simulated a variety of war wounds and thus could be integrated with the surgical training scenarios on the medical train effectively.Conclusion The transparent manikin developed is characterized by high visuality,modularity and blood flow,and meets the demands for surgical training on the medical train.[Chinese Medical Equipment Journal,2025,46(6):111-115]
7.Application review of wearable devices in auxiliary detection and diagnosis of acute mountain sickness
Hui-quan WANG ; Shuai MA ; Guo-sheng CHEN ; Yu GUO ; Jin-han YU ; Zheng-xu YAN ; Ming-hu LIU ; Xin-min DONG
Chinese Medical Equipment Journal 2025;46(9):100-107
The pathological mechanisms and related physiological indicators of acute mountain sickness(AMS)were introduced,and the present situation of wearable devices applied in AMS auxiliary detection and diagnosis were reviewed.The challenges and future development directions of wearable devices applied in auxiliary detection and diagnosis were pointed out.[Chinese Medical Equipment Journal,2025,46(9):100-107]
8.Evaluation and application of an in vitro continuous flow exposure system for inhalation toxicity evaluation
Yin-xia LI ; Yun-hua SHENG ; Yue HU ; Li-ming TANG
Chinese Pharmacological Bulletin 2025;41(2):391-398
Aim To evaluate the continuous flow exposure sys-tem at the air-liquid interface(ALI)in vitro to provide reference data for in vitro studies on inhalation toxicology,and to conduct a preliminary evaluation of the inhalation toxicity of the com-pound limonene by using the system in conjunction with an ALI culture model of Calu-3 cells.Methods Fluorescein sodium(Na-flu)dosimetry supplemented with quartz microbalance(QCM)was used to evaluate the deposition volume and pore-to-pore homogeneity of the ALI continuous flow exposure system;limonene aerosol was exposed to an ALI-cultured model of Calu-3 cells for 3 h using the ALI continuous flow exposure system at exposure doses of high(0.213 μg·cm-2),medium(0.104μg·cm-2),low(0.064 5 μg·cm-2),clean air exposure was used as a negative control group,and the activity,lactate dehydrogenase(LDH)release,trans-epithelial electrical resist-ance(TEER),mucin MUC5AC and inflammatory factor gene expression of the exposed cells were detected after 24 h to evalu-ate the inhalation toxicity of limonene.Results The deposition of sodium fluorescein in the ALI continuous flow exposure system was 0.085±0.007 μg/30 min/well,and inter-well homogeneity was optimized from the initial 26%to less than 10%after sever-al debugging sessions;compared with the control group,there was no significant change in cellular activity and IL-8 gene ex-pression,but cellular IL-6 gene expression increased after limo-nene aerosol exposure;the mid-exposure dose of limonene pro-moted cellular release of LDH and inflammatory factor gene ex-pression.The medium exposure dose of limonene induced the cells to release LDH>10%and decreased the expression of cel-lular tumor necrosis factor TNF-α gene;the high exposure dose of limonene decreased the cellular TEER value,impaired the cellular barrier function,and increased the expression of cellular mucin MUC5AC gene.Conclusions The ALI continuous flow exposure system can be used for inhalation toxicity in vitro stud-ies after commissioning;high and medium exposure doses of limonene are inhalation toxic.
9.Evaluation and application of an in vitro continuous flow exposure system for inhalation toxicity evaluation
Yin-xia LI ; Yun-hua SHENG ; Yue HU ; Li-ming TANG
Chinese Pharmacological Bulletin 2025;41(2):391-398
Aim To evaluate the continuous flow exposure sys-tem at the air-liquid interface(ALI)in vitro to provide reference data for in vitro studies on inhalation toxicology,and to conduct a preliminary evaluation of the inhalation toxicity of the com-pound limonene by using the system in conjunction with an ALI culture model of Calu-3 cells.Methods Fluorescein sodium(Na-flu)dosimetry supplemented with quartz microbalance(QCM)was used to evaluate the deposition volume and pore-to-pore homogeneity of the ALI continuous flow exposure system;limonene aerosol was exposed to an ALI-cultured model of Calu-3 cells for 3 h using the ALI continuous flow exposure system at exposure doses of high(0.213 μg·cm-2),medium(0.104μg·cm-2),low(0.064 5 μg·cm-2),clean air exposure was used as a negative control group,and the activity,lactate dehydrogenase(LDH)release,trans-epithelial electrical resist-ance(TEER),mucin MUC5AC and inflammatory factor gene expression of the exposed cells were detected after 24 h to evalu-ate the inhalation toxicity of limonene.Results The deposition of sodium fluorescein in the ALI continuous flow exposure system was 0.085±0.007 μg/30 min/well,and inter-well homogeneity was optimized from the initial 26%to less than 10%after sever-al debugging sessions;compared with the control group,there was no significant change in cellular activity and IL-8 gene ex-pression,but cellular IL-6 gene expression increased after limo-nene aerosol exposure;the mid-exposure dose of limonene pro-moted cellular release of LDH and inflammatory factor gene ex-pression.The medium exposure dose of limonene induced the cells to release LDH>10%and decreased the expression of cel-lular tumor necrosis factor TNF-α gene;the high exposure dose of limonene decreased the cellular TEER value,impaired the cellular barrier function,and increased the expression of cellular mucin MUC5AC gene.Conclusions The ALI continuous flow exposure system can be used for inhalation toxicity in vitro stud-ies after commissioning;high and medium exposure doses of limonene are inhalation toxic.
10.On-line Measurement of Styrene Secondary Organic Aerosol Using Synchrotron Radiation Vacuum Ultraviolet Photoionization Aerosol Mass Spectrometer
Ming-Qiang HUANG ; Xiao-Bin SHAN ; Liu-Si SHENG ; Zhen-Ya WANG ; Chang-Jin HU ; Xue-Jun GU ; Wei-Jun ZHANG
Chinese Journal of Analytical Chemistry 2024;52(8):1200-1210
Secondary organic aerosol(SOA)produced by photooxidation of styrene and other aromatic compounds is a major part of fine particles in urban atmosphere.In this study,the measurement of component and content of SOA formed from photooxidation of styrene in smog chamber using synchronous radiation vacuum-ultraviolet photoionization aerosol mass spectrometer(VUV-PIAMS)was conducted.Photoionization mass spectra of styrene SOA was detected by synchrotron radiation photon with 10.5 eV,and the proportion of main components was quantified based on the peak area of each ion peak.The photoionization efficiency curve of ion peak was obtained under synchrotron radiation photons in the range from 7.5 to 11.5 eV,and then the ionization potential was acquired for qualitative analysis of the component structure.The results showed that the photoionization mass spectra of styrene SOA mainly contained ion peaks at m/z 106,108,120 and 122,and the ionization potentials of each peak were(9.41±0.03)eV,(8.93±0.03)eV,(9.24±0.03)eV and(9.25±0.03)eV,respectively.Combined with quantum chemistry calculation and off-line measurement verification of infrared absorption spectra and electrospray ionization mass spectra,it was determined that benzaldehyde,benzyl alcohol,4-vinylphenol and benzoic acid were main components of styrene SOA,accounting for 32.5%,17.5%,25%and 15%of the measured components,respectively,and the generated quantity ratio was 13∶7∶10∶6.VUV-PIAMS could overcome the disadvantages of off-line method,and could on-line detect component and content of SOA,proving a useful tool to measure the chemical components and reveal the formation process of SOA particles.