1.Design of performance testing platfrom for proportional solenoid valves in ventilators
Long-ying YE ; Ming-kang TANG ; Pei-pei ZHANG ; Ke-sheng WANG ; Dan LING ; Qian-hong HE
Chinese Medical Equipment Journal 2025;46(1):13-19
Objective To design a performance testing platform to evaluate the working status and performance characteristics of the ventilator proportional solenoid valve.Methods The performance testing platform had its hardware including a high-pressure gas source,a pressure regulating valve,sensors and etc,and its software designed based on PyQt5 and composed of several modules for data acquisition,parameter setting,image display,indicator computation,result output and etc.Two kinds of proportional solenoid valves(Valve 1、Valve2)were selected for static and dynamic tests to verify the performance of the platform.Results The platform developed facilitated the proportional solenoid valve to carry out accurate computation of static and dynamic indicators at real time and time domain and waveform feature extraction of sensor data by precision control and data acquisition for the proportional solenoid valve.Static tests showed that Valve 1 gained advantages over Valve 2 in static flow characteristics involving in lowered repeatability,return error and offset while enhanced stability;dynamic tests indicated Valve 2 had rapid flow variations and significant flow fluctuation impacts,Valve 1 showed smooth dynamic response changes,and Valve 2 behaved better than Valve 1 in dynamic performance.Conclusion The testing platform developed comprehensively demonstrates the performance characteristics and working performance of the ventilator proportional solenoid valve,which is of great significance to enhance the reliability and safety of the ventilator.[Chinese Medical Equipment Journal,2025,46(1):13-19]
2.Relationship between frailty and acute kidney injury after hip fracture surgery in the elderly
Shu-Jun YE ; Kai-Hong ZHANG ; Xiao-Man SUN ; Huan-Kai ZHANG ; Zhi-Liang HUANG ; Duo YANG ; Long-Sheng ZHANG
Medical Journal of Chinese People's Liberation Army 2025;50(7):831-838
Objective To analyze the relationship between frailty and acute kidney injury(AKI)after hip fracture surgery in the elderly.Methods A total of 405 elderly patients who underwent hip fracture surgery in Jieyang People's Hospital from August 2021 to January 2023 were retrospectively analysed.According to the modified frailty index(mFI),they were divided into frail group(mFI≥0.27,n=112)and non-frail group(mFI<0.27,n=293).Postoperative AKI was defined according to the Kidney Disease:Improving Global Outcomes(KDIGO)criteria.After 1:1 propensity score matching(PSM),100 cases in each group were successfully matched.Univariable and multivariable logistic regression models,propensity score adjustment,PSM,inverse probability of treatment weighting(IPTW),standardized mortality ratio weighting(SMRW),pairwise algorithm(PA)weighting,and overlap weighting(OW)methods were used to analyze the relationship between frailty and postoperative AKI.Stratified analyses were performed according to age(≥80 or<80 years),gender,whether angiotensin-converting enzyme inhibitors(ACEI)/angiotensin Ⅱreceptor antagonists(ARB)were used,and whether intraoperative hypotension occurred.Results After PSM,there were no significant differences between the two groups in age,sex,surgical type,ACEI/ARB,blood urea nitrogen,serum creatinine,intraoperative blood loss,and intraoperative hypotension[standardized mean difference(SMD)<0.1].In both the original cohort and the matched cohort,the incidence of AKI was higher in frail group than in non-frail group(25.9%vs.8.9%,P<0.001;28.0%vs.11.0%,P=0.002).Analysis of the risk of postoperative AKI in elderly hip fracture patients in frail group found that compared with the non-frail group,in the univariate logistic regression model the odds ratio(OR)and a 95%confidence interval(CI)for the frail group was 3.59(2.00-6.43),P<0.001,and in the multivariable logistic regression model,the OR(95%CI)for frail group was 3.04(1.55-5.95),P=0.001.After adjustment for propensity score,the OR(95%CI)for frail group was 2.85(1.52-5.34),P=0.001,and the OR(95%CI)for frail group after PSM was 3.15(1.47-6.75),P=0.003.After IPTW,SMRW,PA weighting,and OW,the OR(95%CI)for frail group were 2.48(1.37-4.50),2.43(1.41-4.19),2.63(1.25-5.54),and 2.69(1.07-6.78),respectively,with P<0.05.The interaction tests were not statistically significant for age,sex,use of ACEI/ARB,and intraoperative hypotension(P>0.05).Conclusion In elderly patients with hip fractures,preoperative frailty may be a risk factor for postoperative AKI.
3.Impact of flow diverter malapposition at the aneurysm neck on clinical outcomes and complications of intracranial aneurysms
Jie YANG ; Shuhai LONG ; Shuailong SHI ; Yukun HOU ; Ji MA ; Ye WANG ; Sheng GUAN ; Tengfei LI
Chinese Journal of Neuromedicine 2025;24(6):599-608
Objective:To investigate the impact of flow diverter (FD) malapposition at the aneurysm neck on clinical outcomes and complications of intracranial aneurysms, and identify the influencing factors for intraoperative FD malapposition.Methods:A retrospective study was performed; 153 patients with unruptured saccular aneurysms at the C4-C7 segments of the internal carotid artery accepted single FD implantation at Department of Interventional Radiology, First Affiliated Hospital of Zhengzhou University from June 2022 to March 2024 were chosen. Intraoperative high-resolution C-arm CT was utilized to assess FD apposition at the aneurysm neck. (1) Based on FD apposition at the aneurysm neck as shown, these 153 patients were divided into a malapposition group ( n=23, including 16 patients with malapposition being identified as residual malapposition after intraoperative corrective measures such as microwire massage and 7 patients with malapposition being newly detected in this study) and a complete apposition group ( n=130). Perioperative and follow-up complications were recorded. Clinical outcomes were assessed using modified Rankin Scale (mRS) at the final follow-up (mRS score of 0-2 as favorable outcome), and angiographic outcomes were evaluated by DSA at the final follow-up. Differences in clinical and angiographic outcomes and complication rate were compared between the malapposition group and complete apposition group. (2) Based on FD apposition at the aneurysm neck as shown, these 153 patients were divided into an intraoperative malapposition group ( n=74, including 67 patients with malapposition being detected during surgery and 7 patients with malapposition being newly detected in this study) and an intraoperative complete apposition group ( n=79). Univariate analysis was performed to compare the clinical variables between the intraoperative malapposition group and intraoperative complete apposition group; multivariate Logistic regression was further employed to identify the independent influencing factors for FD malapposition at the aneurysm neck. Results:(1) Four patients (all from the malapposition group) developed perioperative acute in-stent thrombosis. Nine patients experienced ischemic or hemorrhagic stroke during the follow-up, including 6 from the malapposition group and 3 from the complete apposition group; the complication rate in the malapposition group (6/23, 26.1%) was significantly higher than that in the complete apposition group (3/130, 2.3%) during the follow-up ( P<0.05). At the final follow-up, 2 patients (both from the malapposition group) had poor clinical outcome, while the remaining 151 patients had favorable outcome. Proportion of patients with favorable outcome between the two groups was statistically different (91.3%[21/23] vs. 100.0%[130/130], P<0.05). Delayed occlusion was detected in 46 patients (12 from the malapposition group and 34 from the complete apposition group) at the final angiographic follow-up. FD restenosis/re-occlusion was noted in 10 patients, including 6 from the malapposition group and 4 from the complete apposition group. Significant difference in delayed occlusion rate (52.2%[12/23] vs. 26.2%[34/130]) and long-term in-stent stenosis/occlusion rate (26.1%[6/23] vs. 3.1%[4/130]) was observed between the two groups ( P<0.05). (2) Significant difference in aneurysm neck diameter, FD angulation, parent artery stenosis, parent artery diameter ratio>1.2, and presence of branching vessels at the FD implantation site was noted between the intraoperative complete apposition group and intraoperative malapposition group ( P<0.05). Multivariate Logistic regression indicated that aneurysm neck diameter ( OR=1.431, 95% CI: 1.096-1.868, P=0.008), parent artery diameter ratio>1.2 ( OR=2.199, 95% CI: 1.083-4.463, P=0.029), and FD angulation ( OR=1.019, 95% CI: 1.002-1.036, P=0.027) were independent influencing factors for FD malapposition at the aneurysm neck. Conclusion:In FD implantation for intracranial aneurysms, FD malapposition at the aneurysm neck adversely affects delayed occlusion rate and complication rate; aneurysms with wider aneurysm neck diameter, parent artery diameter ratio>1.2, and greater FD angulation are trend to have FD malapposition at the aneurysm neck.
4.Design of performance testing platfrom for proportional solenoid valves in ventilators
Long-ying YE ; Ming-kang TANG ; Pei-pei ZHANG ; Ke-sheng WANG ; Dan LING ; Qian-hong HE
Chinese Medical Equipment Journal 2025;46(1):13-19
Objective To design a performance testing platform to evaluate the working status and performance characteristics of the ventilator proportional solenoid valve.Methods The performance testing platform had its hardware including a high-pressure gas source,a pressure regulating valve,sensors and etc,and its software designed based on PyQt5 and composed of several modules for data acquisition,parameter setting,image display,indicator computation,result output and etc.Two kinds of proportional solenoid valves(Valve 1、Valve2)were selected for static and dynamic tests to verify the performance of the platform.Results The platform developed facilitated the proportional solenoid valve to carry out accurate computation of static and dynamic indicators at real time and time domain and waveform feature extraction of sensor data by precision control and data acquisition for the proportional solenoid valve.Static tests showed that Valve 1 gained advantages over Valve 2 in static flow characteristics involving in lowered repeatability,return error and offset while enhanced stability;dynamic tests indicated Valve 2 had rapid flow variations and significant flow fluctuation impacts,Valve 1 showed smooth dynamic response changes,and Valve 2 behaved better than Valve 1 in dynamic performance.Conclusion The testing platform developed comprehensively demonstrates the performance characteristics and working performance of the ventilator proportional solenoid valve,which is of great significance to enhance the reliability and safety of the ventilator.[Chinese Medical Equipment Journal,2025,46(1):13-19]
5.Impact of flow diverter malapposition at the aneurysm neck on clinical outcomes and complications of intracranial aneurysms
Jie YANG ; Shuhai LONG ; Shuailong SHI ; Yukun HOU ; Ji MA ; Ye WANG ; Sheng GUAN ; Tengfei LI
Chinese Journal of Neuromedicine 2025;24(6):599-608
Objective:To investigate the impact of flow diverter (FD) malapposition at the aneurysm neck on clinical outcomes and complications of intracranial aneurysms, and identify the influencing factors for intraoperative FD malapposition.Methods:A retrospective study was performed; 153 patients with unruptured saccular aneurysms at the C4-C7 segments of the internal carotid artery accepted single FD implantation at Department of Interventional Radiology, First Affiliated Hospital of Zhengzhou University from June 2022 to March 2024 were chosen. Intraoperative high-resolution C-arm CT was utilized to assess FD apposition at the aneurysm neck. (1) Based on FD apposition at the aneurysm neck as shown, these 153 patients were divided into a malapposition group ( n=23, including 16 patients with malapposition being identified as residual malapposition after intraoperative corrective measures such as microwire massage and 7 patients with malapposition being newly detected in this study) and a complete apposition group ( n=130). Perioperative and follow-up complications were recorded. Clinical outcomes were assessed using modified Rankin Scale (mRS) at the final follow-up (mRS score of 0-2 as favorable outcome), and angiographic outcomes were evaluated by DSA at the final follow-up. Differences in clinical and angiographic outcomes and complication rate were compared between the malapposition group and complete apposition group. (2) Based on FD apposition at the aneurysm neck as shown, these 153 patients were divided into an intraoperative malapposition group ( n=74, including 67 patients with malapposition being detected during surgery and 7 patients with malapposition being newly detected in this study) and an intraoperative complete apposition group ( n=79). Univariate analysis was performed to compare the clinical variables between the intraoperative malapposition group and intraoperative complete apposition group; multivariate Logistic regression was further employed to identify the independent influencing factors for FD malapposition at the aneurysm neck. Results:(1) Four patients (all from the malapposition group) developed perioperative acute in-stent thrombosis. Nine patients experienced ischemic or hemorrhagic stroke during the follow-up, including 6 from the malapposition group and 3 from the complete apposition group; the complication rate in the malapposition group (6/23, 26.1%) was significantly higher than that in the complete apposition group (3/130, 2.3%) during the follow-up ( P<0.05). At the final follow-up, 2 patients (both from the malapposition group) had poor clinical outcome, while the remaining 151 patients had favorable outcome. Proportion of patients with favorable outcome between the two groups was statistically different (91.3%[21/23] vs. 100.0%[130/130], P<0.05). Delayed occlusion was detected in 46 patients (12 from the malapposition group and 34 from the complete apposition group) at the final angiographic follow-up. FD restenosis/re-occlusion was noted in 10 patients, including 6 from the malapposition group and 4 from the complete apposition group. Significant difference in delayed occlusion rate (52.2%[12/23] vs. 26.2%[34/130]) and long-term in-stent stenosis/occlusion rate (26.1%[6/23] vs. 3.1%[4/130]) was observed between the two groups ( P<0.05). (2) Significant difference in aneurysm neck diameter, FD angulation, parent artery stenosis, parent artery diameter ratio>1.2, and presence of branching vessels at the FD implantation site was noted between the intraoperative complete apposition group and intraoperative malapposition group ( P<0.05). Multivariate Logistic regression indicated that aneurysm neck diameter ( OR=1.431, 95% CI: 1.096-1.868, P=0.008), parent artery diameter ratio>1.2 ( OR=2.199, 95% CI: 1.083-4.463, P=0.029), and FD angulation ( OR=1.019, 95% CI: 1.002-1.036, P=0.027) were independent influencing factors for FD malapposition at the aneurysm neck. Conclusion:In FD implantation for intracranial aneurysms, FD malapposition at the aneurysm neck adversely affects delayed occlusion rate and complication rate; aneurysms with wider aneurysm neck diameter, parent artery diameter ratio>1.2, and greater FD angulation are trend to have FD malapposition at the aneurysm neck.
6.Research on evaluation and screening indicator for emergency ventilators
Qin-Qi YAO ; Ming-Kang TANG ; Long-Ying YE ; Pei-Pei ZHANG ; Ke-Sheng WANG ; Dan LING ; Qian-Hong HE ; Zhu CHEN
Chinese Medical Equipment Journal 2024;45(7):8-16
Objective To propose an evaluation and screening indicator for the reliability of emergency ventilators.Methods Firstly,a regression model was used to clean the data and remove noise to ensure the accuracy of regression analysis.Then,four groups of highly correlated data combinations,including inspiratory tidal volume-minute expiratory volume,peak airway pressure-minute expiratory volume,peak airway pressure-inspiratory tidal volume and positive end-expiratory pressure(PEEP)-mean airway pressure,were determined with the methods of curve fitting and transfer function,and the difference between the theoretical output and the actual output of the data combinations was regarded as an indicator to judge whether the ventilator functioned well or not;finally,the indicator proposed was applied to single and multiple ventilators,and the feasibility of the indicator was determined by the proportion of the ventilators functioning well.Results The evaluation results with a single ventilator showed the four groups of data combinations had the actual output fitted well with the theoretical output,and all the differences between the theoretical output and the actual output were lower than the threshold;the results with multiple ventilators indicated there were 71.49%ventilators functioning well,which was very close to the actual result that 72%ventilators behaved well.Conclusion The evaluation and screening indicator for emergency ventilators has high feasibility,and theoretical support is provided for reliability assessment and selection of series of emergency treatment equipment.[Chinese Medical Equipment Journal,2024,45(7):8-16]
7.Prediction, analysis and application of learning curve of tooth preparation for all ceramic crowns of maxillary central incisors.
Si Yu WU ; Ya Ning LI ; Xiao ZHANG ; Long Wei LV ; Yun Song LIU ; Hong Qiang YE ; Yong Sheng ZHOU
Journal of Peking University(Health Sciences) 2023;55(1):108-113
OBJECTIVE:
To predict the learning curve of tooth preparation for all ceramic crowns of maxillary central incisors on phantom head simulators for graduate students participating in standardized dental resident training based on the modified Wright learning curve model, then to analyze and applicate the learning curve.
METHODS:
Twelve graduate students participating in standardized dental resident training were selected to prepare the resin maxillary central incisors on phantom head simulators for all ceramic crowns 4 times. The results of preparation were evaluated by 3 prosthetic experts with at least 10 years' experience focusing on the reduction, contour, taper, shoulder, finish line, margin placement, adjacent tooth injury, and preparation time for tooth preparation. The learning rate of tooth preparation was calculated by scores of tooth preparation of 4 times. The learning curve of tooth preparation was predicted based on the modified Wright learning curve model. According to the criteria of standardized training skill examinations for dental residents in Beijing, 80 was taken as the qualified standard score. The minimum training times for tooth preparation to satisfy the qualified standard score (80) was calculated, to analyze the characteristics of learning curve and evaluate the effectiveness of tooth preparation.
RESULTS:
The scores of 4 tooth preparation were 64.03±7.80, 71.40±6.13, 74.33±5.96, and 75.98±4.52, respectively. The learning rate was (106±4)%, which showed the learning curve an upward trend. There were no significant differences between the qualified standard score and the predicted scores of tooth preparation from the 5th preparation to the 13th preparation (P > 0.05). The predicted score of the 14th preparation was higher than the qualified standard score (P < 0.05).
CONCLUSION
The trend of the learning curve of tooth preparation for all ceramic crowns of maxillary central incisors on phantom head simulators for graduate students participating in standardized dental resident training is upward, which predicts the minimum training times higher than the qualified standard score is 14 times.
Humans
;
Tooth Preparation, Prosthodontic/methods*
;
Incisor
;
Learning Curve
;
Crowns
;
Tooth Preparation
;
Ceramics
;
Dental Porcelain
;
Dental Prosthesis Design
8.Incidence and prognosis of olfactory and gustatory dysfunctions related to infection of SARS-CoV-2 Omicron strain: a national multi-center survey of 35 566 population.
Meng Fan LIU ; Rui Xia MA ; Xian Bao CAO ; Hua ZHANG ; Shui Hong ZHOU ; Wei Hong JIANG ; Yan JIANG ; Jing Wu SUN ; Qin Tai YANG ; Xue Zhong LI ; Ya Nan SUN ; Li SHI ; Min WANG ; Xi Cheng SONG ; Fu Quan CHEN ; Xiao Shu ZHANG ; Hong Quan WEI ; Shao Qing YU ; Dong Dong ZHU ; Luo BA ; Zhi Wei CAO ; Xu Ping XIAO ; Xin WEI ; Zhi Hong LIN ; Feng Hong CHEN ; Chun Guang SHAN ; Guang Ke WANG ; Jing YE ; Shen Hong QU ; Chang Qing ZHAO ; Zhen Lin WANG ; Hua Bin LI ; Feng LIU ; Xiao Bo CUI ; Sheng Nan YE ; Zheng LIU ; Yu XU ; Xiao CAI ; Wei HANG ; Ru Xin ZHANG ; Yu Lin ZHAO ; Guo Dong YU ; Guang Gang SHI ; Mei Ping LU ; Yang SHEN ; Yu Tong ZHAO ; Jia Hong PEI ; Shao Bing XIE ; Long Gang YU ; Ye Hai LIU ; Shao wei GU ; Yu Cheng YANG ; Lei CHENG ; Jian Feng LIU
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2023;58(6):579-588
Objective: This cross-sectional investigation aimed to determine the incidence, clinical characteristics, prognosis, and related risk factors of olfactory and gustatory dysfunctions related to infection with the SARS-CoV-2 Omicron strain in mainland China. Methods: Data of patients with SARS-CoV-2 from December 28, 2022, to February 21, 2023, were collected through online and offline questionnaires from 45 tertiary hospitals and one center for disease control and prevention in mainland China. The questionnaire included demographic information, previous health history, smoking and alcohol drinking, SARS-CoV-2 vaccination, olfactory and gustatory function before and after infection, other symptoms after infection, as well as the duration and improvement of olfactory and gustatory dysfunction. The self-reported olfactory and gustatory functions of patients were evaluated using the Olfactory VAS scale and Gustatory VAS scale. Results: A total of 35 566 valid questionnaires were obtained, revealing a high incidence of olfactory and taste dysfunctions related to infection with the SARS-CoV-2 Omicron strain (67.75%). Females(χ2=367.013, P<0.001) and young people(χ2=120.210, P<0.001) were more likely to develop these dysfunctions. Gender(OR=1.564, 95%CI: 1.487-1.645), SARS-CoV-2 vaccination status (OR=1.334, 95%CI: 1.164-1.530), oral health status (OR=0.881, 95%CI: 0.839-0.926), smoking history (OR=1.152, 95%CI=1.080-1.229), and drinking history (OR=0.854, 95%CI: 0.785-0.928) were correlated with the occurrence of olfactory and taste dysfunctions related to SARS-CoV-2(above P<0.001). 44.62% (4 391/9 840) of the patients who had not recovered their sense of smell and taste also suffered from nasal congestion, runny nose, and 32.62% (3 210/9 840) suffered from dry mouth and sore throat. The improvement of olfactory and taste functions was correlated with the persistence of accompanying symptoms(χ2=10.873, P=0.001). The average score of olfactory and taste VAS scale was 8.41 and 8.51 respectively before SARS-CoV-2 infection, but decreased to3.69 and 4.29 respectively after SARS-CoV-2 infection, and recovered to 5.83and 6.55 respectively at the time of the survey. The median duration of olfactory and gustatory dysfunctions was 15 days and 12 days, respectively, with 0.5% (121/24 096) of patients experiencing these dysfunctions for more than 28 days. The overall self-reported improvement rate of smell and taste dysfunctions was 59.16% (14 256/24 096). Gender(OR=0.893, 95%CI: 0.839-0.951), SARS-CoV-2 vaccination status (OR=1.334, 95%CI: 1.164-1.530), history of head and facial trauma(OR=1.180, 95%CI: 1.036-1.344, P=0.013), nose (OR=1.104, 95%CI: 1.042-1.171, P=0.001) and oral (OR=1.162, 95%CI: 1.096-1.233) health status, smoking history(OR=0.765, 95%CI: 0.709-0.825), and the persistence of accompanying symptoms (OR=0.359, 95%CI: 0.332-0.388) were correlated with the recovery of olfactory and taste dysfunctions related to SARS-CoV-2 (above P<0.001 except for the indicated values). Conclusion: The incidence of olfactory and taste dysfunctions related to infection with the SARS-CoV-2 Omicron strain is high in mainland China, with females and young people more likely to develop these dysfunctions. Active and effective intervention measures may be required for cases that persist for a long time. The recovery of olfactory and taste functions is influenced by several factors, including gender, SARS-CoV-2 vaccination status, history of head and facial trauma, nasal and oral health status, smoking history, and persistence of accompanying symptoms.
Female
;
Humans
;
Adolescent
;
SARS-CoV-2
;
Smell
;
COVID-19/complications*
;
Cross-Sectional Studies
;
COVID-19 Vaccines
;
Incidence
;
Olfaction Disorders/etiology*
;
Taste Disorders/etiology*
;
Prognosis
9.Polymorphisms of pvcrt-o and pvmdr1 genes of 48 Plasmodium vivax isolates from the China-Myanmar border
YE Run ; YE Sheng-yu ; ZHANG Yi-long ; ZHANG Dong-mei
China Tropical Medicine 2023;23(1):22-
Abstract: Objective To detect the polymorphisms of drug resistance-related genes pvcrt-o and pvmdr1 of Plasmodium vivax in lazan city in the China-Myanmar border, in order to guide the treatment plan of Plasmodium vivax. Methods A total of 48 Plasmodium vivax samples were collected from Lazan in the China-Myanmar border in 2007, and fragments of pvcrt-o and pvmdr1 genes were amplified by PCR and sequenced. The sequences were aligned with the Salvador I (Sal-I) strain reference genome sequences to determine the presence of SNPs. Results The target fragments of pvcrt-o gene were amplified from 39 Plasmodium vivax samples, while pvmdr1 genes were amplified from 40 samples. Amongst them, 25 samples had AAG insertion before the 10th amino acid (K10 insertion) of pvcrt-o gene, accounting for 64.1%. Non-synonymous mutations were detected at three loci of pvmdr1 gene (T958M, Y976F, and F1076L), the mutation rates were 100%, 22.5%, and 55.0%, respectively. There were three haplotypes of pvmdr1 gene, of which the triple mutant 958M/976F/1076L accounted for 22.5% (9/40), the double mutant 958M/Y976/1076L accounted for 32.5% (13/40), and the single mutant 958M/Y976/F1076 accounted for 45.0% (18/40). The proportion of strains with pvcrt-o and pvmdr1 gene mutation is 63.16%, which is significantly different from those only with pvmdr1 mutation. Conclusions The proportion of pvcrt-o and pvmdr1 gene mutation of 48 Plasmodium vivax isolates is high in the China-Myanmar border, and there is a certain degree of correlation between the two gene mutations. To assess changes in Plasmodium vivax drug resistance in this region, it is required to improve the surveillance of these two molecular markers.
10.Efficacy and safety of Regan Syrup in treatment of common cold (wind-heat syndrome):a multicenter, randomized, double-blind, double-dummy, placebo and positive drug-controlled, parallel, phase Ⅱb clinical trial.
Yi-Min HU ; Qing-Quan LIU ; Sheng CHEN ; Ye-Yang CHEN ; Lan WANG ; Nan LIU ; Ning CHEN ; You-Yu LONG ; Hui DONG
China Journal of Chinese Materia Medica 2023;48(8):2233-2240
Regan Syrup has the effect of clearing heat, releasing exterior, benefiting pharynx and relieving cough, and previous phase Ⅱ clinical trial showed that the efficacy of Regan Syrup high-dose and low-dose groups was better than that of the placebo group, and there was no statistically significant difference in the safety between the three groups. The present study was conducted to further investigate the efficacy and safety of the recommended dose(20 mL) of Regan Syrup in the treatment of common cold(wind-heat syndrome). Patients who met the inclusion and exclusion criteria were selected and divided into the test group(Regan Syrup+Shufeng Jiedu Capsules placebo), positive drug group(Regan Syrup placebo+Shufeng Jiedu Capsules) and placebo group(Regan Syrup placebo+Shufeng Jiedu Capsules placebo) at a 1∶1∶1 using a block randomization method. The course of treatment was 3 days. A total of 119 subjects were included from six study centers, 39 in the test group, 40 in the positive drug group and 40 in the placebo group. The onset time of antipyretic effect was shorter in the test group than in the placebo group(P≤0.01) and the positive drug group, but the difference between the test group and the positive drug group was not significant. The test group was superior to the positive drug group in terms of fever resolution(P<0.05), and had a shorter onset time of fever resolution than the placebo group, but without obvious difference between the two groups. Compared to the positive drug group, the test group had shortened disappearance time of all symptoms(P≤0.000 1). In addition, the test group was better than the positive drug group and the placebo group in relieving symptoms of sore throat and fever(P<0.05), and in terms of clinical efficacy, the recovery rate of common cold(wind-heat syndrome) was improved in the test group compared to that in the placebo group(P<0.05). On the fourth day after treatment, the total TCM syndrome score in both test group and positive drug group was lower than that in the placebo group(P<0.05). There was no significant difference in the incidence of adverse events between three groups and none of them experienced any serious adverse events related to the study drug. The results indicated that Regan Syrup could shorten the onset time of antipyretic effect, reduce the time of fever resolution, alleviate the symptoms such as sore throat and fever caused by wind-heat cold, reduce the total score of Chinese medicine symptoms, and improve the clinical recovery rate with good safety.
Humans
;
Antipyretics/therapeutic use*
;
Capsules
;
Common Cold/diagnosis*
;
Double-Blind Method
;
Fever/drug therapy*
;
Hot Temperature
;
Pharyngitis
;
Treatment Outcome

Result Analysis
Print
Save
E-mail