1.Research on software development and smart manufacturing platform incorporating near-infrared spectroscopy for measuring traditional Chinese medicine manufacturing process.
Yan-Fei WU ; Hui XU ; Kai-Yi WANG ; Hui-Min FENG ; Xiao-Yi LIU ; Nan LI ; Zhi-Jian ZHONG ; Ze-Xiu ZHANG ; Zhi-Sheng WU
China Journal of Chinese Materia Medica 2025;50(9):2324-2333
Process analytical technology(PAT) is a key means for digital transformation and upgrading of the traditional Chinese medicine(TCM) manufacturing process, serving as an important guarantee for consistent and controllable TCM product quality. Near-infrared(NIR) spectroscopy has become the core technology for measuring the TCM manufacturing process. By incorporating NIR spectroscopy into PAT and starting from the construction of a smart platform for the TCM manufacturing process, this paper systematically described the development history and innovative application of the combination of NIR spectroscopy with chemometrics in measuring the TCM manufacturing process by the research team over the past two decades. Additionally, it explored the application of a validation method based on accuracy profile(AP) in the practice of NIR spectroscopy. Furthermore, the software development progress driven by NIR spectroscopy supported by modeling technology was analyzed, and the prospect of integrating NIR spectroscopy in smart factory control platforms was exemplified with the construction practices of related platforms. By integrating with the smart platform, NIR spectroscopy could improve production efficiency and guarantee product quality. Finally, the prospect of the smart platform application in measuring the TCM manufacturing process was projected. It is believed that the software development for NIR spectroscopy and the smart manufacturing platform will provide strong technical support for TCM digitalization and industrialization.
Spectroscopy, Near-Infrared/methods*
;
Drugs, Chinese Herbal/analysis*
;
Software
;
Medicine, Chinese Traditional
;
Quality Control
2.Development of intelligent equipment for rapid microbial detection of Atractylodis Macrocephalae Rhizoma decoction pieces based on measurement technology for traditional Chinese medicine manufacturing.
Yang LIU ; Wu-Zhen QI ; Yu-Tong WU ; Shan-Xi ZHU ; Xiao-Jun ZHAO ; Qia-Tong XIE ; Yu-Feng GUO ; Jing ZHAO ; Nan LI ; Shi-Jun WANG ; Qi-Hui SUN ; Zhi-Sheng WU
China Journal of Chinese Materia Medica 2025;50(16):4610-4618
Microbial detection and control of traditional Chinese medicine(TCM) decoction pieces are crucial for the quality control of TCM preparations. It is also a key area of research in the measurement technology and equipment development for TCM manufacturing. Guided by TCM manufacturing measurement methodologies, this study presented a design of a novel portable microbial detection device, using Atractylodis Macrocephalae Rhizoma decoction pieces as a demonstration. Immunomagnetic separation technology was employed for specific isolation and labeling of target microorganisms. Enzymatic signal amplification was utilized to convert weak biological signals into colorimetric signals, constructing an optical biosensor. A self-developed smartphone APP was further applied to analyze the colorimetric signals and quantify target concentrations. A portable and automated detection system based on Arduino microcontroller was developed to automatically perform target microbial separation/extraction, as well as mimetic enzyme labeling and catalytic reactions. The developed equipment specifically focuses on the rapid and quantitative microbial analysis of TCM active pharmaceutical ingredients, intermediates in TCM manufacturing, and final TCM products. Experimental results demonstrate that the equipment could detect Salmonella in samples within 2 h, with a detection limit as low as 5.1 × 10~3 CFU·mL~(-1). The equipment enables the rapid detection of microorganisms in TCM decoction pieces, providing a potential technical solution for on-site rapid screening of microbial contamination indicators in TCM. It has broad application prospects in measurement technology for TCM manufacturing and offers strong technical support for the modernization, industrialization, and intelligent development of TCM.
Drugs, Chinese Herbal/analysis*
;
Atractylodes/microbiology*
;
Rhizome/microbiology*
;
Biosensing Techniques/methods*
;
Medicine, Chinese Traditional
;
Colorimetry/instrumentation*
;
Quality Control
3.Additional role of low-density lipoprotein cholesterol on the risk of osteoporosis in men with or without coronary heart disease: a real-world longitudinal study.
Jing ZENG ; Zi-Mo PAN ; Ting LI ; Ze-Yu CHEN ; Xiao-Yan CAI ; Mei-Liang GONG ; Xin-Li DENG ; Sheng-Shu WANG ; Nan LI ; Miao LIU ; Chun-Lin LI
Journal of Geriatric Cardiology 2025;22(2):219-228
BACKGROUND:
Early control of low-density lipoprotein cholesterol (LDL-C) is crucial for reducing the progress of cardiovascular disease. However, its additional role to the risk of primary osteoporosis in men with coronary heart disease was inconclusive. Our study aims to determine the association of LDL-C and its trajectories for osteoporosis risk in the middle-aged and aged men of China.
METHODS:
The retrospective cohort study of 1546 men aged 69.74 ± 11.30 years conducted in Beijing, China from 2015 to 2022. And the incidence of primary osteoporosis was annually recorded. LDL-C trajectories were further identified by latent class growth model using repeated measurements of LDL-C. The association of baseline LDL-C for osteoporosis was estimated using hazard ratio (HR) with 95% CI in Cox proportional hazard model, while mean level and trajectories of LDL-C for osteoporosis were evaluated using odds ratio (OR) with 95% CI in logistic regression model.
RESULTS:
During the median 6.2-year follow-up period, 70 men developed primary osteoporosis. The higher level of baseline LDL-C (HR = 1.539, 95% CI: 1.012-2.342) and mean LDL-C (OR = 2.190, 95% CI: 1.443-3.324) were associated with higher risk of osteoporosis in men with coronary heart disease after adjusted for covariates. Compared with those in the LDL-C trajectory of low-stable decrease, participants with medium-fluctuant trajectory, whose longitudinal LDL-C started with a medium LDL-C level and appeared an increase and then decrease, were negatively associated with osteoporosis risk (OR = 2.451, 95% CI: 1.152-5.216). And participants with initially high LDL-C level and then a rapid decrease demonstrated a tendency towards reduced risk (OR = 0.718, 95% CI: 0.212-2.437).
CONCLUSIONS
Elevated LDL-C level and its long-term fluctuation may increase the risk of primary osteoporosis in men. Early controlling a stable level of LDL-C is also essential for bone health.
4.Design of detection gloves for orthopedic manipulation
Liu-peng SHI ; Bin SHI ; Sheng-nan CAO ; Ji-qing WANG ; Liang-yu XIE ; Guo-dong SUN
Chinese Medical Equipment Journal 2025;46(7):27-33
Objective To design a pairs of detection gloves for orthopedic manipulation to solve the problems of orthopedic manipulation in accurate,visual and quantitative description and reproduction in teaching.Methods The orthopedic manipulation detection gloves were mainly composed of a detection body worn on the hands,a main control module and a data visualization system.The detection body was made of multi-layer flexible materials such as rubber,cotton and non-woven fabrics,which integrated inertial sensors,pressure sensors and a data acquisition device;the main control module consisted of a filter circuit,an A/D converter(MCP3008)and a main controller(ARM-STM32 microcontroller);the data visualization system was designed based on the Unity 3D platform.Results The orthopedic manipulation detection gloves effectively detected the rotation angle of the knuckle during the orthopedic process with a high accuracy rate.Conclusion The orthopedic manipulation detection gloves can quantitatively display the abstract orthopedic manipulation,and can provide support for intelligent orthopedic teaching and orthopedic manipulation optimization.[Chinese Medical Equipment Journal,2025,46(7):27-33]
5.Safety and efficacy of intrasaccular flow disruptor in intracranial aneurysms
Jifa LIU ; Yuanzhi LI ; Feng FAN ; Hang ZHANG ; Nan MA ; Zhen WANG ; Sheng GUAN
Chinese Journal of Neuromedicine 2025;24(3):230-234
Objective:To explore the safety and efficacy of intrasaccular flow disruptor in intracranial aneurysms, including wide-necked aneurysms.Methods:A retrospective analysis was performed; 102 patients with intracranial aneurysms treated with intrasaccular flow disruptor at Department of Neurointervention, First Affiliated Hospital of Zhengzhou University from August 2022 to November 2024 were enrolled; their clinical and imaging data were collected. The aneurysm characteristics and perioperative complications were summarized; aneurysm occlusion was evaluated by Woven EndoBridge occlusion scale (WOS) immediately after surgery and during the follow-up period.Results:Among the 102 aneurysms, 33 were anterior cerebral artery aneurysms, 40 were middle cerebral artery aneurysms, 17 were internal carotid artery aneurysms and 12 were basilar artery aneurysms; 73 aneurysms were regular intracranial saccular aneurysms and 29 were irregular saccular ones (17 of them with daughter sacs); 12 aneurysms were ruptured at acute phase. The surgical success rate was 100%: single intrasaccular flow disruptor was implanted into 95 patients, and stent-assisted or salvage treatments were given to 7 patients). Immediately after surgery, WOS grading A was noted in 5 patients, grading B in 7, grading C in 31, and grading D in 59. Two patients suffered severe perioperative complications and passed away: one patient died for ischemic complications that ensued after stent salvage treatment (parent artery being compressed by intrasaccular flow disruptor); the other patient died for hemorrhagic complications triggered by rupture of an initially unruptured aneurysm following intrasaccular flow disruptor implantation. Among them, 52 patients completed postoperative DSA follow-up, with a median follow-up of 205 (168, 292) days; WOS grading A was noted in 31 patients, grading B in 9, grading C in 8, and grading D in 4 at the last follow-up; the full occlusion rate was 92.3%, and no ischemic or hemorrhagic adverse events occurred.Conclusion:Intrasaccular flow disruptor shows high short-term safety and good efficacy in the treatment of intracranial aneurysms.
6.Efficacy and safety of intrasaccular flow disruptor in wide-necked intracranial aneurysms: a multicenter retrospective study
Xiaowen ZHANG ; Jing LI ; Xifeng LI ; Chuanzhi DUAN ; Aihua LIU ; Huaizhang SHI ; Haowen XU ; Nan MA ; Zhiqiang YAO ; Feng FAN ; Chao LIU ; Jinyi LI ; Hailong ZHONG ; Mengyan FAN ; Jiaxin WAN ; Rijin LIN ; Huixiang LIU ; Jiamei ZHANG ; Xin ZHANG ; Sheng GUAN
Chinese Journal of Neuromedicine 2025;24(1):16-22
Objective:To evaluate the efficacy and safety of intrasaccular flow disruptor in wide-necked intracranial aneurysms.Methods:One hundred and seventeen patients with wide-necked intracranial aneurysms treated with intrasaccular flow disruptor were collected from Department of Neurointervention (First Affiliated Hospital of Zhengzhou University), Department of Neurosurgery (Beijing Tiantan Hospital, Capital Medical University), Department of Cerebrovascular Surgery, Neurosurgery Center (Zhujiang Hospital, Southern Medical University), and Department of Neurosurgery (First Affiliated Hospital of Harbin Medical University) from August 2022 to March 2024. Raymond-Roy Occlusion Classification (RROC) was employed to evaluate aneurysm embolization immediately after procedure; cranial CT or MRI within 48 hours of embolization were performed to identify any new intracranial hemorrhage, subarachnoid hemorrhage, or new symptomatic cerebral infarction related to the intracranial aneurysms. Modified Rankin Scale (mRS) was used to assess the neurological function at discharge. Imaging follow-up and outpatient follow-up were performed at 6 months after embolization to evaluate the aneurysm occlusion degree and complications.Results:A total of 117 intrasaccular flow disruptors were implanted in 117 patients, with a technical success rate of 100%; 115 patients (98.3%) enjoyed successful one-time release of their disruptors, and 2 patients (1.7%) required retrieval and redirection of the disruptors before second successful attempt. Flow disruptor plus stent was performed in 13 patients (11.1%). Immediately after procedure, RROC grading I was noted in 3 patients, grading II in 51 patients and grading III in 63 patients. Cranial CT or MRI within 48 hours of embolization indicated no new intracranial hemorrhage, subarachnoid hemorrhage, or symptomatic cerebral infarction related to the intracranial aneurysms. All patients had mRS score of 0 at discharge. Eighty-three patients completed a 6-month follow-up (RROC grading I in 41 patients, grading II in 33 patients and grading III in 9 patients), without ischemic or hemorrhagic adverse events.Conclusion:The results of this study preliminarily suggest that intrasaccular flow disruptor is effective and safe in wide-necked intracranial aneurysms.
7.Neuroform Atlas stent-assisted coil embolization for middle cerebral artery bifurcation aneurysms: a multicenter retrospective study
Mengyan FAN ; Jing LI ; Chuanzhi DUAN ; Huaizhang SHI ; Aihua LIU ; Xiaochuan SUN ; Feng FAN ; Jinyi LI ; Chao LIU ; Haowen XU ; Linyu WANG ; Zhiqiang YAO ; Hailong ZHONG ; Xiaowen ZHANG ; Rijin LIN ; Jiaxin WAN ; Nan ZHANG ; Huixiang LIU ; Jiamei ZHANG ; Sheng GUAN
Chinese Journal of Neuromedicine 2025;24(2):141-146
Objective:To evaluate the efficacy and safety of Neuroform Atlas stent-assisted coil embolization in patients with middle cerebral artery bifurcation aneurysms.Methods:A retrospective analysis was performed; the clinical data of 46 patients with middle cerebral artery bifurcation aneurysms accepted Neuroform Atlas stent-assisted coil embolization in First Affiliated Hospital of Zhengzhou University, Beijing Tiantan Hospital Affiliated to Capital Medical University, First Affiliated Hospital of Harbin Medical University, Zhujiang Hospital of Southern Medical University and First Affiliated Hospital of Chongqing Medical University from January 2022 to March 2024 were collected. There were 28 ruptured aneurysms (60.87%) and 18 unruptured aneurysms (39.13%). Follow-up was performed for more than 3 months; Raymond-Roy grading was used to evaluate the aneurysm embolization immediately after embolization and during follow-up; perioperative hemorrhagic or ischemic complications were recorded; modified Rankin Scale (mRS) was used to evaluate the prognosis of the patients at discharge and during follow-up (mRS score≤2: good prognosis, and mRS score>2: poor prognosis).Results:Coil embolization was successful in all 46 patients. DSA immediately after embolization showed that 41 patients (89.13%) had completely occluded aneurysms (Raymond-Roy grading I), 2 patients (4.35%) had residual aneurysm neck (Raymond-Roy grading Ⅱ) and 3 patients (6.52%) had partially occluded aneurysms (Raymond-Roy grading Ⅲ). Perioperative complications occurred in 5 patients, including 2 with postoperative cerebral infarction, 1 with hydrocephalus, 1 with postoperative pneumonia leading to respiratory failure, and 1 with stent thrombosis during embolization. Both at discharge and 3 months after embolization, 43 patients (93.48%) had good prognosis and 3 patients (6.52%) had poor prognosis. No obvious ischemic complications (such as stent restenosis) or hemorrhagic complications (such as re-rupture of the aneurysms) were found in all patients. Thirty patients (65.22%) had imaging follow-up for 6-12 months: 26 (86.67%) had Raymond-Roy grading I, 3 (10.00%) had Raymond-Roy grading II, and 1 (3.33%) had Raymond-Roy grading III.Conclusion:Neuroform Atlas stent-assisted coil embolization has good short-term efficacy and high safety in middle cerebral artery bifurcation aneurysms, but long-term follow-up observation is still needed to verify its efficacy.
8.Clinical guideline for diagnosis and treatment of nonunion of osteoporotic vertebral fractures (version 2025)
Haipeng SI ; Le LI ; Junjie NIU ; Wencan ZHANG ; Fuxin WEI ; Jinqiu YUAN ; Qiang YANG ; Hongli WANG ; Guangchao WANG ; Shihong CHEN ; Yunzhen CHEN ; Xiaoguang CHENG ; Jianwen DONG ; Shiqing FENG ; Rui GU ; Yong HAI ; Tianyong HOU ; Bo HUANG ; Xiaobing JIANG ; Lei ZANG ; Chunhai LI ; Nianhu LI ; Hua LIN ; Hongjian LIU ; Peng LIU ; Xinyu LIU ; Sheng LU ; Shibao LU ; Chunshan LUO ; Lvy CHAOLIANG ; Lvy WEIJIA ; Xuexiao MA ; Wei MEI ; Chunyang MENG ; Cailiang SHEN ; Chunli SONG ; Ruoxian SONG ; Jiacan SU ; Honglin TENG ; Hui SHENG ; Beiyu WANG ; Bingwu WANG ; Liang WANG ; Xiangyang WANG ; Nan WU ; Guohua XU ; Yayi XIA ; Jin XU ; Youjia XU ; Jianzhong XU ; Cao YANG ; Maowei YANG ; Zibin YANG ; Xiaojian YE ; Hailong YU ; Xijie YU ; Hua YUE ; Zhili ZENG ; Xinli ZHAN ; Hui ZHANG ; Peixun ZHANG ; Wei ZHANG ; Zhenlin ZHANG ; Jianguo ZHANG ; Tengyue ZHU ; Qiang LIU ; Huilin YANG
Chinese Journal of Trauma 2025;41(10):932-945
Nonunion of osteoporotic vertebral fractures (OVF), predominantly affecting the elderly, can lead to intractable pain, vertebral collapse, progressive kyphotic deformity, and neurological impairment, significantly compromising patients′ quality of life. There exists considerable debate on diagnosis and management of OVF, encompassing key issues such as clinical diagnosis and staging criteria for nonunion, surgical indications and procedure selection, and postoperative rehabilitation planning. Currently, there lacks standardized clinical guideline and expert consensus on the diagnosis and management of OVF nonunion in China. To address this gap, Minimally Invasive Surgery Group of Chinese Orthopedic Association, Osteoporosis Committee of Chinese Association of Orthopedic Surgeons, Prevention and Rehabilitation Committee for Osteoporosis of Chinese Association of Rehabilitation Medicine and Minimally Invasive Orthopedic Surgery Branch of China Association for Geriatric Care jointly organized domestic experts in spinal surgery, endocrinology, and rehabilitation to formulate the Clinical guideline for the diagnosis and treatment for nonunion of osteoporotic vertebral fractures ( version 2025), based on existing literature and clinical experience and adhering to principles of scientific rigor and practicality. The guideline provided 13 evidence-based recommendations encompassing diagnosis and treatment of OVF nonunion, aiming to standardize its clinical management.
9.Targeted screening and profiling of massive components of colistimethate sodium by two-dimensional-liquid chromatography-mass spectrometry based on self-constructed compound database.
Xuan LI ; Minwen HUANG ; Yue-Mei ZHAO ; Wenxin LIU ; Nan HU ; Jie ZHOU ; Zi-Yi WANG ; Sheng TANG ; Jian-Bin PAN ; Hian Kee LEE ; Yao-Zuo YUAN ; Taijun HANG ; Hai-Wei SHI ; Hongyuan CHEN
Journal of Pharmaceutical Analysis 2025;15(2):101072-101072
In-depth study of the components of polymyxins is the key to controlling the quality of this class of antibiotics. Similarities and variations of components present significant analytical challenges. A two-dimensional (2D) liquid chromatography-mass spectrometr (LC-MS) method was established for screening and comprehensive profiling of compositions of the antibiotic colistimethate sodium (CMS). A high concentration of phosphate buffer mobile phase was used in the first-dimensional LC system to get the components well separated. For efficient and high-accuracy screening of CMS, a targeted method based on a self-constructed high resolution (HR) mass spectrum database of CMS components was established. The database was built based on the commercial MassHunter Personal Compound Database and Library (PCDL) software and its accuracy of the compound matching result was verified with six known components before being applied to genuine sample screening. On this basis, the unknown peaks in the CMS chromatograms were deduced and assigned. The molecular formula, group composition, and origins of a total of 99 compounds, of which the combined area percentage accounted for more than 95% of CMS components, were deduced by this 2D-LC-MS method combined with the MassHunter PCDL. This profiling method was highly efficient and could distinguish hundreds of components within 3 h, providing reliable results for quality control of this kind of complex drugs.
10.Baicalein attenuates lipopolysaccharide-induced myocardial injury by inhibiting ferroptosis via miR-299b-5p/HIF1-α pathway.
Wen-Yan ZHOU ; Jian-Kui DU ; Hong-Hong LIU ; Lei DENG ; Kai MA ; Jian XIAO ; Sheng ZHANG ; Chang-Nan WANG
Journal of Integrative Medicine 2025;23(5):560-575
OBJECTIVE:
Baicalein has been reported to have wide therapeutic effects that act through its anti-inflammatory activity. This study examines the effect and mechanism of baicalein on sepsis-induced cardiomyopathy (SIC).
METHODS:
A thorough screening of a small library of natural products, comprising 100 diverse compounds, was conducted to identify the most effective drug against lipopolysaccharide (LPS)-treated H9C2 cardiomyocytes. The core target proteins and their associated signaling pathways involved in baicalein's efficacy against LPS-induced myocardial injury were predicted by network pharmacology.
RESULTS:
Baicalein was identified as the most potent protective agent in LPS-exposed H9C2 cardiomyocytes. It exhibited a dose-dependent inhibitory effect on cell injury and inflammation. In the LPS-induced septic mouse model, baicalein demonstrated a significant capacity to mitigate LPS-triggered myocardial deficits, inflammatory responses, and ferroptosis. Network pharmacological analysis and experimental confirmation suggested that hypoxia-inducible factor 1 subunit α (HIF1-α) is likely to be the crucial factor in mediating the impact of baicalein against LPS-induced myocardial ferroptosis and injury. By combining microRNA (miRNA) screening in LPS-treated myocardium with miRNA prediction targeting HIF1-α, we found that miR-299b-5p may serve as a regulator of HIF1-α. The reduction in miR-299b-5p levels in LPS-treated myocardium, compared to the control group, was reversed by baicalein treatment. The reverse transcription quantitative polymerase chain reaction, Western blotting, and dual-luciferase reporter gene analyses together identified HIF1-α as the target of miR-299b-5p in cardiomyocytes.
CONCLUSION
Baicalein mitigates SIC at the miRNA level, suggesting the therapeutic potential of it in treating SIC through the regulation of miR-299b-5p/HIF1-α/ferroptosis pathway. Please cite this article as: Zhou WY, Du JK, Liu HH, Deng L, Ma K, Xiao J, Zhang S, Wang CN. Baicalein attenuates lipopolysaccharide-induced myocardial injury by inhibiting ferroptosis via miR-299b-5p/HIF1-α pathway. J Integr Med. 2025; 23(5):560-575.
Flavanones/pharmacology*
;
Animals
;
MicroRNAs/genetics*
;
Lipopolysaccharides
;
Hypoxia-Inducible Factor 1, alpha Subunit/genetics*
;
Ferroptosis/drug effects*
;
Mice
;
Myocytes, Cardiac/metabolism*
;
Signal Transduction/drug effects*
;
Rats
;
Male
;
Mice, Inbred C57BL
;
Cardiomyopathies/etiology*
;
Cell Line
;
Sepsis/complications*

Result Analysis
Print
Save
E-mail