1.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
2.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
3.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
4.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
5.Formulation of expert consensus on clinical application of external ethnic medicine: taking Baimai Ointment as an example.
Ying-Jie GUAN ; Xiao-Qiao REN ; Hong-Sheng ZHAN ; Zhi-Xiu SHEN ; Kai-Lie LIU ; Wen-Jing CHANG ; Yun LI ; Wei CHEN
China Journal of Chinese Materia Medica 2023;48(3):847-852
The concept of ethnic medicine is divided into a broad sense and a narrow sense. The broad concept refers to the traditional medicine of the Chinese nation, and the narrow concept refers to the traditional medicine of Chinese ethnic minorities. The external medicine is one of the main forms of ethnic medicine, and it is also the important content of ethnic medicine for external use, which is widely used in clinical practice. As the theory of ethnic medicine is unique, the application methods have certain characteristics, which are the key technical parts of clinical practice. However, the existing traditional Chinese medicine consensus formulation me-thods cannot meet the needs of the consensus formulation of the external ethnic medicine. Therefore, the methods suitable for expert consensus on external ethnic medicine are required. This article took Expert opinion on clinical application of Baimai Ointment as an exa-mple, and explorde a reasonable, effective, multi-dimensional, and multi-stage method to formulate expert consensus on the external ethnic medicine. In this research, three-dimensional sources of information, including ancient classics, clinical research evidence, and expert application experiences, were systematically and scientifically collected. After organization and analysis, the information was formed into comprehensive evidence. In a formal consensus meeting, part of the recommendations reached consensus. As to the issues that did not reach agreement, in-depth interviews were used to explore the reasons for the differences and resolve the disagreements. Finally, unanimous recommendations were reached. There are common problems during the formulation process of Expert opinion on clinical application of Baimai Ointment. This study is expected to provide references for the formulation of expert consensus on other external ethnic medicine.
Humans
;
Biological Products
;
Consensus
;
Drugs, Chinese Herbal
6.Chinese Medicine Intervenes in NLRP3 Inflammasome in Treatment of Bone and Joint Diseases: A Review
Tuanzhuang ZHANG ; Yuan SONG ; Zhijun HE ; Tao LIU ; Xiyan LYU ; Xiaotao WEI ; Jiaxuan SHEN ; Xudong LIANG ; Keyu ZHU ; Jing QIAO
Chinese Journal of Experimental Traditional Medical Formulae 2023;29(22):193-203
The prevalence of osteoporosis, osteoarthritis, gouty arthritis, rheumatoid arthritis, and intervertebral disc degeneration is increasing year by year with the growing number of elderly people, and the common clinical manifestations of these diseases include severe pain in different areas, which seriously affects the daily life of the patients. Therefore, how to relieve the pain and reduce the prevalence of bone and joint diseases and improve the quality of life of the patients is a hot spot in the medical field. Studies have confirmed that NOD-like receptor family, pyrin domain-containing protein 3 (NLRP3) inflammasomes, as pattern recognition receptors, are involved in the inflammation, chondrocyte proliferation, osteoblast and osteoclast differentiation, intervertebral disc cell inflammation and scorching, extracellular matrix degradation and apoptosis, mitochondrial dysfunction, endoplasmic reticulum stress, and reactive oxygen species damage, demonstrating close link with the development of bone and joint diseases. Chinese medicine has a long history and demonstrates remarkable therapeutic effects in the treatment of bone and joint diseases. It can mitigate the pathological changes of bone and joint diseases by inhibiting NLRP3 inflammasomes to alleviate the pain, playing a role in preventing and treating these diseases. Therefore, this paper briefly describes the relationship between NLRP3 inflammasomes and the development of bone and joint diseases by reviewing the latest research progress at home and abroad. We summarize the latest studies about the active components, extracts, and compound prescriptions of Chinese medicines in the treatment of bone and joint diseases via regulating NLRP3 inflammasomes. This review is expected to offer new insights into the in-depth research on the pathogenesis and drug treatment of bone and joint diseases and provide a basis for the clinical application of Chinese medicine in the prevention and treatment of such diseases.
7.Application of target controlled infusion mode based on precision anesthesia concept in cardiac surgery anesthesia
Shen-Qiao WEI ; Hai-Qing HUANG ; Ke QIN ; Bing-Rong MAO ; Xiang-Fei MA ; Shi-Jia LYU ; Xiu-Xia ZHAO ; Li-Fu HUANG
Journal of Regional Anatomy and Operative Surgery 2023;32(12):1076-1079
Objective To explore the effect and safety of target controlled infusion mode based on precision anesthesia concept in cardiac surgery anesthesia.Methods A total of 100 patients underwent cardiac surgery in our hospital were selected as the research subjects,and they were randomly divided into the control group and the observation group,with 50 cases in each group.The surgical types,surgical related indicators,dosage of anesthetic drugs,and complications of the two groups were compared.Results There was no statistically significant difference in the proportions of patients who underwent coronary artery bypass surgery,valve surgery,macrovascular surgery,artial septal defect repair surgery,or other types of surgery between the two groups(P>0.05).There were statistically significant differences in the surgical time,bleeding volume,infusion volume,proportion of cardiopulmonary bypass,times of postoperative analgesic drug use and mechanical ventilation duration between the two groups(P<0.05).The usage of various anesthetic drugs in the observation group was lower than that in the control group,with statistically significant difference(P<0.05).The incidence of complication in the observation group was lower than that in the control group,and the difference was statistically significant(P<0.05).Conclusion The target controlled infusion mode based on precision anesthesia concept can be used for cardiac surgery anesthesia to reduce the dosage of anesthetic drugs and postoperative complications,and improve the anesthesia effect and surgical safety.
8.Comparison of value of different positive diagnostic criteria of lung ultrasound in evaluating cardiogenic pulmonary edema
Wen-Yue CAO ; E SHEN ; Li QIAO ; Jian-Wei MA ; Qi-Zhi LIU
Chinese Journal of Clinical Medicine 2023;30(6):971-974
Objective To compare the diagnostic efficacy of 3 lung ultrasound criteria in evaluating cardiogenic pulmonary edema,so as to obtain the optimal diagnostic criterion and to provide effective auxiliary measure for the rapid diagnosis of cardiogenic pulmonary edema.Methods A total of 98 patients who underwent lung ultrasound in the Shanghai Chest Hospital from June 2022 to November 2022 were included.Three positive criteria were defined according to the number and distribution of positive points based on the pleural and B lines:criterion 1 was set as at least 2 positive points;criterion 2 was set as at least 3 positive points;criterion 3 was set as at least 1 positive point on each side.The efficacies of 3 criteria in diagnosis of cardiogenic pulmonary edema,and their consistencies with clinical diagnosis were compared.Results The sensitivities of criterion 1,criterion 2,and criterion 3 were 88%,72%and 79%,the specificities was 89%,100%and 93%,the accuracies was 87%,88%and 87%,respectively.The criteri on 2 showed a higher consistency in the diagnosis of cardiogenic pulmonary edema with clinical diagnosis(Kappa value=0.877);the criterion 1 and criterion 3 were generally consistent in the diagnosis of cardiogenic pulmonary edema with clinical diagnosis(Kappa values were 0.783 and 0.727,respectively).Conclusions The diagnostic efficacies of the 3 positive lung ultrasound criteria for cardiogenic pulmonary edema are high,and"at least 3 positive points"is more helpful for clinical diagnosis.
9.Impact of pain catastrophizing on disability in patients with low back pain mediated by anxiety and depression
Rongmin BIAN ; Wei SHEN ; Rong YANG ; Hong CHEN ; Qian SHI ; Zhaoxin WANG ; Jianwei SHI ; Wenya YU ; Yipeng LYU ; Qiao CHU
Chinese Journal of General Practitioners 2022;21(10):953-958
Objective:To investigate the effects of anxiety and depressive symptoms in mediation of pain catastrophizing on disability in patients with low back pain.Methods:A cross-sectional survey was conducted among 97 patients with low back pain in the Changjiang Subdistrict community health center from July to October 2021. Oswestry Disability Index, pain catastrophic subscale in Coping Strategies Questionnaire-24, Generalized Anxiety Disorder Scale-short version, Patient Health Depression Questionnaire-short version were used to evaluate the activity dysfunction, pain catastrophic cognition and anxiety and depression levels of patients,respectively. Path analysis was implemented to test the mediation model, and the indirect effects were assessed using the bootstrap procedure with bias-corrected 95 %CI. Results:Results suggested significant positive correlations among pain catastrophizing, anxiety, depressive symptoms and disability of patients. In addition, both anxiety and depressive symptoms significantly mediated the impact of pain catastrophizing on disability (standardized indirect effects were 0.183 and 0.197, P<0.05). Patients with higher levels of pain catastrophic cognition showed higher levels of anxiety and depressive symptoms (β=0.757, 0.720; P<0.01), and reported more severe motor dysfunction (β=0.241, 0.274; P<0.05). Conclusions:Our findings suggest that anxiety and depression may be the psychological pathways through which pain catastrophizing predicts disability in patients with low back pain. Effective psychological interventions, such as emotion regulation and stress reduction strategies should be considered in treatment and supportive care for patients with low back pain.
10.Analysis of the Distribution of Total Phosphine and the Characteristics of Phosphine Poisoning in 29 Victims.
Hui YAN ; Meng DU ; Zheng QIAO ; Ping XIANG ; Bao-Hua SHEN ; Min SHEN ; Wei LIU
Journal of Forensic Medicine 2022;38(2):254-257
OBJECTIVES:
To study the distribution of total phosphine in phosphine poisoning victims and summarize the characteristics of phosphine poisoning cases.
METHODS:
The phosphine and its metabolites in the biological samples of 29 victims in 16 phosphine poisoning cases were qualified and quantified by headspace gas chromatography-mass spectrometry.
RESULTS:
Five victims among 29 were poisoned by ingestion of aluminium phosphide and 24 by inhalation of phosphine gas. Phosphine metabolites were detected in the biological samples of 23 victims, and the concentrations of total phosphine in blood ranged 0.5-34.0 μg/mL. The total concentration of phosphine in liver tissue was up to 71.0 μg/g. Phosphine was not detected in the blood of the other six survived victims, which may be related to the small amount of phosphine exposure and the delay in blood sampling.
CONCLUSIONS
The total concentration of phosphine in blood and tissues caused by aluminum phosphine ingestion is higher than that caused by phosphine gas inhalation. The death cases of phosphine inhalation are characterized by long exposure time, repeated exposures and age susceptibility.
Aluminum Compounds/analysis*
;
Gas Chromatography-Mass Spectrometry
;
Humans
;
Liver/chemistry*
;
Phosphines/analysis*
;
Poisoning/diagnosis*

Result Analysis
Print
Save
E-mail