1.Clinical Efficacy and Radiographic Outcomes of Manipulative Reduction Combined with Small Splint Fixation for Distal Radius Fractures:A Retrospective Multicenter Study with Propensity Score Matching
Mao WU ; Guoda DAI ; Yang SHAO ; Shaoshuo LI ; Zhen HUA ; Hengyan CUI ; Tingchen ZHU ; Dipeng LI ; Jintao LIU ; Ming ZHOU ; Peimin WANG ; Liyong ZHANG ; Jianwei WANG
Journal of Traditional Chinese Medicine 2026;67(10):1086-1092
ObjectiveTo observe the clinical efficacy and radiographic outcomes of manipulative reduction combined with small splint fixation in the treatment of distal radius fractures. MethodsThe clinical data of 1051 patients with distal radius fractures were retrospectively collected from five hospitals included in the Jiangsu Diagnosis and Treatment Data Platform for Traditional Chinese Medicine(TCM) Dominant Diseases. Propensity score matching at a 1∶4 ratio was applied, resulting in 580 cases selected for final analysis, which comprised 448 patients in the TCM group(manipulative reduction plus small splint fixation) and 132 in the surgical treatment group(open reduction and internal fixation). Each group was further stratified into type A, B, and C subgroups based on AO fracture classification. Radiographic indicators including palmar tilt, radial inclination, and radial height were compared between groups before treatment and 1 day, 1 week, and 4-6 weeks after treatment, and pain visual analog scale(VAS) scores before treatment and 1 week and 4-6 weeks after treatment were also compared. Wrist joint function was assessed 12 weeks after treatment, using the Dienst wrist function score and the Gartland and Werley(G-W) wrist function score. Additionally, the radiographic indicators at different timepoints and the 12-week wrist function levels were compared between groups across different fracture types. ResultsNo statistically significant difference was observed in radiographic indicators and VAS scores at all timepoints before and after treatment, as well as wrist joint function grades assessed by the Dienst score and the G-W score at 12 weeks after treatment (P>0.05). Compared to those before treatment, both groups showed increased palmar tilt, radial inclination, and radial height 1 week and 4-6 weeks after treatment, and decreased VAS scores (P<0.05). Compared to those 1 week after treatment, both groups showed a decrease in palmar tilt, an increase in radial inclination and radial height, and a reduction in VAS score 4-6 weeks after treatment(P<0.05). In type A and B subgroups, the surgical treatment group had a higher radial inclination than the TCM group 4-6 weeks after treatment, while in the type C subgroup, a higher radial height was shown in the surgical treatment group than in the TCM group 4-6 weeks after treatment(P<0.05). In type C subgroup, there was significant difference between groups in the wrist joint function by G-W scores 12 weeks after treatment(P<0.05). ConclusionManipulative reduction combined with small splint fixation can maintain fracture alignment and alleviate pain in treating distal radius fractures, which achieves therapeutic outcomes comparable to surgical treatment. It is particularly suitable for type A and B fractures and can be considered an effective treatment option for distal radius fractures.
2.Construction and Clinical Validation of a Deep Learning-Based Automatic Measurement Model for Palmar Tilt and Radial Inclination in Distal Radius Fractures
Guoda DAI ; Jianwei WANG ; Mao WU ; Bin KANG ; Yang SHAO ; Hengyan CUI ; Shaoshuo LI ; Tingchen ZHU ; Zhen HUA ; Zhongming SHEN ; Jintao LIU ; Ming ZHOU
Journal of Traditional Chinese Medicine 2026;67(10):1093-1100
ObjectiveTo construct an automatic measurement model for palmar tilt and radial inclination suitable for traditional Chinese medicine (TCM) clinical scenarios, and to validate its accuracy and efficiency in TCM manipulative reduction settings. MethodsData on anteroposterior (AP) and lateral X-rays of distal radius fractures were collected from patients admitted to 18 TCM/ integrated TCM and western medicine hospitals in Jiangsu province between September 1st, 2023, and September 1st, 2024, via the Jiangsu Diagnosis and Treatment Big Data Platform for TCM Dominant Diseases. A medical image segmentation framework based on multi-scale feature fusion and edge-awareness was employed, combined with anatomical knowledge specific to TCM orthopedics, to optimize the feature extraction strategy of an artificial intelligence (AI) model. This framework enabled automatic segmentation of fracture regions and measurement of distal radius palmar tilt and radial inclination. The accuracy of the AI model in measuring radial inclination and volar tilt was validated, and the measurement time and average time gain rate of the AI model were compared to those of manual measurement. ResultsA total of 15,444 AP and lateral X-ray images of distal radius fractures were collected, and were divided into a training set (11,144 images, 5066 AP and 6078 lateral), a validation set (3700 images, 1840 AP and 1860 lateral), and an independent test set (600 images, 300 AP and 300 lateral) after preprocessing. In the measurement of 300 AP X-rays in the independent test set for radial inclination, when the degree error between AI measurement and manual measurement was <3° and <5°, AI measurement accuracy was 83% and 93%, respectively. In 300 lateral X-rays in the test set for palmar tilt, when AI measurements had an error of <3° and <5° compared to manual measurements, corresponding accuracy rate was 78% and 90%, respectively. For 50 X-ray images, AI measurement time was (1.37±0.05) min for radial inclination while manual measurement time was (22.57±2.52) min (P<0.001); in terms of palmar tilt, the AI measurement time was (1.33±0.14) min, shorter than (23.70±2.80) min for manual measurement time (P<0.001). Average time gain rates for manual and AI measurements were 93.93% and 94.39% respectively. ConclusionAn automatic measurement model for palmar tilt and radial inclination in distal radius fractures has been established, enabling more accurate and efficient assessment as well as providing a tool to support the quantitative evaluation of the efficacy of TCM manipulative reduction and large-sample clinical research.
3.Tandem mass spectrometry screening and genetic analysis of neonates with Urea cycle disorders.
Wei ZHOU ; Huizhong LI ; Li YANG ; Fang SHAO ; Maosheng GU
Chinese Journal of Medical Genetics 2025;42(1):26-33
OBJECTIVE:
To explore the results of four types of Urea cycle disorders (UCDs) in newborns from the Xuzhou region, assess the efficacy of newborn screening by tandem mass spectrometry (MS/MS), and analyze their genetic characteristics.
METHODS:
A retrospective analysis was performed using tandem mass spectrometry to screen for inherited metabolic disorders in 691 712 newborns at the Maternal and Child Health Care Hospital of Xuzhou from November 2015 to December 2023. Ten children (cases 1-10) were diagnosed with Ornithine transcarbamylase deficiency (OTCD), Carbamoylphosphate synthase 1 deficiency (CPS1D), Arginase deficiency (ARGD), and Argininosuccinate synthase deficiency (ASSD) based on MS/MS and genetic testing. This study was approved by the Medical Ethics Committee of Xuzhou Maternity and Child Health Care Hospital (Ethics No.XZFY2024-051K-01J).
RESULTS:
A total of 691 712 neonates were screened for UCDs using MS/MS, which identified 1 237, 1 237, 510, and 1 009 initial positive cases for OTCD, CPS1D, ASSD, and ARGD, respectively. After genetic testing, 1 case of OTCD, 1 case of CPS1D, 1 case of ASSD, and 7 cases of ARGD were confirmed. The overall positive predictive value for these four UCDs was 0.362%. Among the 10 diagnosed UCD cases, four novel variants were identified, which included OTC: c.1024C>A (p.L342M) and ASS1: c.826A>G (p.M276V), c.695C>T (p.P232L) and c.694C>T (p.P232S). Bioinformatic analysis has rated these as variants of uncertain clinical significance or likely pathogenic based on guidelines from the American College of Medical Genetics and Genomics (ACMG).
CONCLUSION
The incidence of four UCDs in neonates from the Xuzhou area is relatively low, and there is a correlation between genetic variants and clinical phenotypes. For novel variants with uncertain clinical significance or suspected pathogenicity, their pathogenicity should be clarified in conjunction with clinical and biochemical indicators. The four novel pathogenic variants of UCDs identified in this study have enriched the mutational spectrum of UCDs-associated genes in the Xuzhou region.
Humans
;
Infant, Newborn
;
Tandem Mass Spectrometry/methods*
;
Urea Cycle Disorders, Inborn/diagnosis*
;
Neonatal Screening/methods*
;
Genetic Testing/methods*
;
Female
;
Retrospective Studies
;
Male
;
Ornithine Carbamoyltransferase Deficiency Disease/diagnosis*
;
Mutation
;
Carbamoyl-Phosphate Synthase (Ammonia)/genetics*
;
Ornithine Carbamoyltransferase/genetics*
4.Analysis of clinical applicability and implementation of expert consensus on the implementation and removal of protective restraints in psychiatry
Jianing GU ; Dongmei XU ; Jing SHAO ; Jing GAO ; Zhuang CAI ; Yanhua QU ; Xiaolu YE ; Mengqian ZHANG ; Dongli MEI ; Yanhong ZHANG ; Bo YANG ; Gen CHENG ; Lina WANG ; Junrong YE ; Ruiyue LIN ; Yongling ZHOU ; Runjuan MA
Chinese Journal of Nursing 2025;60(11):1359-1365
Objective To understand the clinical applicability and implementation of expert consensus on the implementation and removal of protective restraints in psychiatry,and to provide references for promoting the standardized practice of psychiatric protective restraints and updating the consensus.Methods By the convenience sampling method,a questionnaire survey was conducted among nurses from 480 hospitals in 30 provinces from June 15 to July 15,2024.The survey was conducted using the instrument for evaluating clinical applicability of guide-lines(version 2.0)and a self-compiled questionnaire on the clinical implementation of the restraint consensus.Results A total of 7,844 valid questionnaires were collected,with a valid questionnaire recovery rate of 93.78%.The results of clinical applicability scoring showed that the consensus had the lowest availability score(64.72%)and the highest acceptability score(76.74%).The results showed that nurses' receiving training and the level of their hospitals were the main influencing factors for scores in various dimensions(P<0.05).4,774 participants(87.42%)believed that the application of consensus could enhance the standardization of nurses' restraint operations.The safety rate of the restraint consensus was 79.51%,and the economic ratio was 76.87%.Among the evaluators,1,739(22.17%)believed that there were implementation obstacles in the consensus.Conclusion The clinical applicability of the consensus is relatively good,and the application of the consensus helps to improve the standardization of clinical operations.In the future,efforts should be made to strengthen the promotion and training of the consensus,develop hierarchical promotion strategies according to the characteristics of medical institutions,and improve the quality of evidence for the consensus,so as to further enhance the clinical application effect of the consensus.
5.Percutaneous vertebroplasty using partition injection technique for Kümmell's disease of stages Ⅰ and Ⅱ
Yili LI ; Yong YANG ; Yaojun DAI ; Shuang CHEN ; Xiaoguang ZHOU ; Zhenhui ZHANG ; Zhe SHAO ; Xiaofei XIE ; Xiaoteng LI ; Jili ZHANG ; Tingkun LIU ; Wei MEI
Chinese Journal of Orthopaedic Trauma 2025;27(4):297-304
Objective:To explore the efficacy of percutaneous vertebroplasty (PVP) using the partition injection technique in the treatment of Kümmell’s disease of stages Ⅰ and Ⅱ.Methods:A retrospective study was conducted of the 30 patients with stage Ⅰ or Ⅱ Kümmell’s disease (the partition group) who had been treated by PVP using the partition injection technique at Department of Spinal Surgery, Zhengzhou Orthopedic Hospital from January 2020 to January 2022. The data of another 30 patients who had been treated at the same department and the same period using conventional PVP for stage Ⅰ or Ⅱ Kümmell's disease were selected as the conventional group. In the partition group, there were 13 males and 17 females, with an age of (72.3±10.1) years and disease duration of (3.1±1.5) months. Seventeen thoracic and 13 lumbar vertebrae were affected. In the conventional group, there were 11 males and 19 females, with an age of (75.5±12.7) years and disease duration of (3.5±1.8) months. Eighteen thoracic and 12 lumbar vertebrae were affected. Surgical time, volume of bone cement injected, bone cement leakage, and bone cement distribution were compared between the 2 groups. The heights of the anterior and middle vertebral bodies, kyphotic Cobb angle, visual analog scale (VAS) pain score, and Oswestry disability index (ODI) were assessed postoperatively at 1 day, 6 months, and the last follow-up and compared between the 2 groups.Results:No significant differences were found in the baseline data between the 2 groups, indicating comparability ( P>0.05). All patients were followed up for (17.3±3.1) months. There were no significant differences in the surgical time or bone cement leakage between the 2 groups ( P>0.05). The volume of bone cement injected in the partition group was significantly higher [(6.3±1.5) mL] than that in the conventional group [(4.9±1.0) mL] ( P<0.05). Bone cement distribution was significantly better in the partition group than that in the conventional group ( P<0.05). At postoperative 1 day, 6 months, and the last follow-up, the partition group was significantly better than the conventional group in anterior vertebral body height, middle vertebral body height, and kyphotic Cobb angle ( P<0.05). At the 6-month and the last follow-ups, the partition group was also significantly better than the conventional group in VAS pain score and ODI ( P<0.05). Conclusion:In the treatment of Kümmell’s disease of stages Ⅰ and Ⅱ, compared with conventional PVP, PVP using the partition injection technique may lead to better long-term outcomes due to its better bone cement distribution, more adequate cement injection, and better restoration of vertebral body heights and correction of local deformity.
6.Phase Ⅲ, multicenter, randomized comparative study of LY01005 and Zoladex ? for patients with premenopausal breast cancer
Xiying SHAO ; Qingyuan ZHANG ; Zhaofeng NIU ; Man LI ; Jingfen WANG ; Zhanhong CHEN ; Ruizhen LUO ; Guangdong QIAO ; Jianguo WANG ; Liyuan QIAN ; Ronghua YANG ; Zhendong CHEN ; Jian WANG ; Yumin YAO ; Jianghua OU ; Tao SUN ; Qiao CHENG ; Yongsheng WANG ; Jian HUANG ; Hongying ZHAO ; Wuyun SU ; Zhong OUYANG ; Yu DING ; Lilin CHEN ; Sumei YANG ; Mengsheng CUI ; Aimin ZANG ; Enxiang ZHOU ; Peizhi FAN ; Jing ZHANG ; Qiang LIU ; Yuee TENG ; Hui LI ; Jianyun NIE ; Jin YANG ; Xiaojia WANG ; Zefei JIANG
Chinese Journal of Oncology 2025;47(4):340-348
Background:To compare the efficacy and safety of monthly administrations of gonadotropin releasing hormone (GnRH) agonists LY01005 and Zoladex ? in Chinese patients with premenopausal breast cancer. Methods:From October 2020 to November 2021, 188 premenopausal breast cancer patients were enrolled in 34 hospitals and randomized 1:1 to receive either LY01005 or Zoladex ? every 28 days for a total of three injections. All patients concomitantly received oral tamoxifen (TAM). The primary efficacy endpoint was cumulative probability of maintaining menopausal level [oestradiol (E2) ≤30 pg/ml] from day 29 to day 85. The second efficacy endpoint included changes in E2, luteinizing hormone (LH), and follicle-stimulating hormone (FSH) compared with the baseline. Pharmacokinetics (PK), pharmacodynamics (PD), and safety were analyzed. The study also evaluated the pharmacokinetic and pharmacodynamic characteristics of LY01005. Results:A total of 188 patients were randomised and 187 patients received either LY01005 or Zoladex ?. Cumulative probabilities of maintaining menopausal level (E2≤30 pg/ml) from day 29 to day 85 were 93.1% for LY01005 and 86.3% for Zoladex ?. The between-group difference was 6.8% (95% CI: -2.3%, 15.9%) and primary efficacy in the LY01005 group was not inferior to that in the Zoladex ? group. Changes in E2, LH, and FSH levels compared with the baseline were equivalent between the two groups (E2: 89.34% to 90.23% vs. 82.11% to 85.02%; LH: 88.89% to 95.52% vs. 89.70% to 97.02%; FSH: 75.36% to 80.85% vs.73.07% to 80.24%, respectively). After three consecutive doses of LY01005, the LH and FSH levels of the subjects showed a transient increase after the first dose, reached a peak on the second day and then started to decrease. The LH and FSH reached a lower level and remained at or below that level until the 85th day. Both treatments were well-tolerated. Conclusion:LY01005 is as effective as Zoladex ? in suppressing E2 to menopausal levels in Chinese patients with premenopausal breast cancer, with a similar safety profile.
7.Structural equation analysis of the incidence of shoulder WMSDs and individual and work-related factors
Shuang ZHOU ; Zhongxu WANG ; Ruijie LING ; Qing XU ; Huadong ZHANG ; Yimin LIU ; Gang LI ; Yan YIN ; Hua SHAO ; Jue LI ; Hengdong ZHANG ; Bing QIU ; Dayu WANG ; Qiang ZENG ; Yan YE ; Bin XIAO ; Hua ZOU ; Jianchao CHEN ; Dongxia LI ; Yongquan LIU ; Jixiang LIU ; Enfei JIANG ; Jun QI ; Liangying MEI ; Xianfeng ZHAO ; Mimi YANG ; Ning JIA
Chinese Journal of Industrial Hygiene and Occupational Diseases 2025;43(2):91-100
Objective:To investigate the incidence of shoulder work-related musculoskeletal disorders (WMSDs) among occupational population in China, and to explore their intrinsic association with personal and work-related factors.Methods:In April 2024, 73497 valid questionnaires of the Chinese version of the Musculoskeletal Disorders Electronic Questionnaire were retrospectively analyzed from June 2018 to December 2023 in 22 provinces and 29 key industries in China, and the general information, occurrence of WMSDs and related risk factors of key occupational populations in different regions in China were collected. By using Chi-square test and confirmatory factor analysis, the relationship between shoulder fatigue and pain in key occupational groups and individual factors, work type, work posture and work organization was discussed, and the internal relationship was analyzed based on structural equation model.Results:Higher incidence of shoulder fatigue and pain were associated with female, lack of physical exercise, uncomfortable working posture and neck leaning forward ( P<0.05). Structural equation model analysis showed that work type, work posture and work organization were strongly correlated ( r=0.58, 0.55). Work organization and work type were strongly correlated with shoulder fatigue ( r=0.65) and moderately correlated with shoulder fatigue ( r=0.21). Shoulder fatigue was moderately associated with shoulder pain ( r=0.40). Individual factors, work type, work posture and shoulder fatigue could directly affect shoulder pain ( OR=0.07, -0.09, 0.17 and 0.40), and work type and work posture could also indirectly affect shoulder pain through shoulder fatigue ( OR=0.08, 0.03). Work organization only indirectly affected shoulder pain through shoulder fatigue ( OR=0.26) . Conclusion:The main influencing factor of shoulder pain is shoulder fatigue, followed by work posture and individual factors. Structural equation model can better reflect the complex relationship between work type, work posture and work organization and shoulder WMSDs. Improving work posture and work organization may be an effective way to control the influence of shoulder fatigue on shoulder pain.
8.Tandem mass spectrometry screening and genetic analysis of neonates with Urea cycle disorders in Xuzhou region
Wei ZHOU ; Huizhong LI ; Li YANG ; Fang SHAO ; Maosheng GU
Chinese Journal of Medical Genetics 2025;42(1):26-33
Objective:To explore the results of four types of Urea cycle disorders (UCDs) in newborns from the Xuzhou region, assess the efficacy of newborn screening by tandem mass spectrometry (MS/MS), and analyze their genetic characteristics.Methods:A retrospective analysis was performed using tandem mass spectrometry to screen for inherited metabolic disorders in 691 712 newborns at the Maternal and Child Health Care Hospital of Xuzhou from November 2015 to December 2023. Ten children (cases 1-10) were diagnosed with Ornithine transcarbamylase deficiency (OTCD), Carbamoylphosphate synthase 1 deficiency (CPS1D), Arginase deficiency (ARGD), and Argininosuccinate synthase deficiency (ASSD) based on MS/MS and genetic testing. This study was approved by the Medical Ethics Committee of Xuzhou Maternity and Child Health Care Hospital (Ethics No.XZFY2024-051K-01J).Results:A total of 691 712 neonates were screened for UCDs using MS/MS, which identified 1 237, 1 237, 510, and 1 009 initial positive cases for OTCD, CPS1D, ASSD, and ARGD, respectively. After genetic testing, 1 case of OTCD, 1 case of CPS1D, 1 case of ASSD, and 7 cases of ARGD were confirmed. The overall positive predictive value for these four UCDs was 0.362%. Among the 10 diagnosed UCD cases, four novel variants were identified, which included OTC: c. 1024C>A (p.L342M) and ASS1: c. 826A>G (p.M276V), c.695C>T (p.P232L) and c. 694C>T (p.P232S). Bioinformatic analysis has rated these as variants of uncertain clinical significance or likely pathogenic based on guidelines from the American College of Medical Genetics and Genomics (ACMG). Conclusion:The incidence of four UCDs in neonates from the Xuzhou area is relatively low, and there is a correlation between genetic variants and clinical phenotypes. For novel variants with uncertain clinical significance or suspected pathogenicity, their pathogenicity should be clarified in conjunction with clinical and biochemical indicators. The four novel pathogenic variants of UCDs identified in this study have enriched the mutational spectrum of UCDs-associated genes in the Xuzhou region.
9.Reliability and validity of the repeatable battery for assessment of neuropsychological status scale in maintenance hemodialysis patients
Xiaoqi WANG ; Conghui LIU ; Feng SHAO ; Jingjing ZHOU ; Fan YANG ; Zhongxin LI
Journal of Capital Medical University 2025;46(5):877-884
Objective To evaluate the reliability and validity of the Chinese version of the Repeatable Battery for the Assessment of Neuropsychological Status(RBANS)in patients with maintenance hemodialysis(MHD).Methods The general information and medical history of 84 MHD patients were collected,and the Mini-Mental State Exam(MMSE),Montreal Cognitive Assessment Scale(MoCA),and RBANS were conducted.The reliability of the scale was assessed by Cronbach α and split-half reliability.The structure and convergent validity of the scale were assessed by confirmatory factor analysis,and the RBANS scores'correlation to MoCA and MMSE scores was analyzed by Spearman correlation analysis.The predictive value of the RBANS total score on cognitive impairment(CI)was analyzed by receiver operating characteristic(ROC)curve.Results The Cronbach's alpha coefficient of the RBANS total scale was 0.896,split-half reliability was 0.911,and reliability for the five dimensions of the RBANS ranged from 0.618 to 0.791.Confirmatory factor analysis indicated that the overall fit of the five-dimensional model of the RBANS scale was acceptable(χ2/df=1.587,root mean square error of approximation=0.084,comparative fit index=0.967,incremental fit index=0.968,Tucker-Lewis index=0.947,goodness of fit index=0.891).The average variance extracted(AVE)for the five dimensions of the RBANS ranged from 0.525 to 0.863,while the composite reliability(CR)ranged from 0.733 to 0.926,indicating good convergent validity of the scale.Furthermore,Spearman correlation analysis revealed that the total RBANS score was negatively correlated to the age of MHD patients and positively correlated to years of education,as well as the total scores of MMSE and MoCA(all P<0.01).The ROC curve analysis indicated that the area under the curve(AUC)for the total RBANS score in predicting CI was 0.891(P<0.01),suggesting a high predictive value.Conclusion The Chinese version of RBANS has good reliability and validity in MHD patients,and can be used as a measure of cognitive function in MHD patients.
10.Application of a new type of navigation assisted reduction device in reduction and fixation of A3N0/1 thoracolumbar fracture with the aid of navigation
Yili LI ; Yibao SUN ; Yaojun DAI ; Shuang CHEN ; Xiaoguang ZHOU ; Yong YANG ; Zhenhui ZHANG ; Zhe SHAO ; Xiaoteng LI ; Bo SUN ; Wei MEI
Chinese Journal of Orthopaedics 2025;45(14):918-927
Objective:To evaluate the clinical efficacy of a novel reduction device in the treatment of A3N0/1 thoracolumbar fracture using navigation-assisted techniques.Methods:A retrospective analysis was conducted on 45 patients (29 males, 16 females; mean age 40.67±16.11 years, range 24-57) with thoracolumbar fractures who underwent fracture reduction and pedicle screw fixation via the Wiltse approach at Zhengzhou Orthopaedic Hospital between January 2022 and January 2023. Injury levels included: T 10 in 2 cases, T 11 in 5 cases, T 12 in 13 cases, L 1 in 20 cases, L 2 in 3 cases, L 3 in 2 cases. All patients underwent fracture reduction via the Wiltse approach using the spinal fracture reduction instrument for vertebral body reduction. Among them, 20 patients received O-arm navigation-assisted internal fixation and vertebral reduction (O-arm group), while 25 received C-arm fluoroscopy-guided internal fixation and vertebral reduction (C-arm group). Operative time, intraoperative blood loss, vertebral reduction time using the instrument, first-time screw placement success rate, screw placement accuracy, and complications were compared. Mid-vertebral body height ratio (MVBHr), local Cobb angle of the fractured vertebra, visual analogue scale (VAS) score, and Oswestry disability index (ODI) were compared preoperatively, at 1 week postoperatively, 3 months postoperatively, and final follow-up. Results:All surgeries were successfully completed in both groups. Operative time was significantly shorter in the O-arm group (106.8±14.4 min) than in the C-arm group (119.1±16.4 min, P<0.05). All patients were followed up for a mean duration of 15.9±3.9 months (range 12-20 months). Vertebral reduction time was significantly shorter in the O-arm group (11.0±2.2 min) than in the C-arm group (20.4±5.7 min, P<0.05). The first-time screw placement success rate was significantly higher in the O-arm group (100%) than in the C-arm group (95.3%, P<0.05). Screw placement accuracy (Grade I) was significantly higher in the O-arm group (117 screws, 97.5%) than in the C-arm group (136 screws, 90.7%, P<0.05). No cases of wrong-level surgery, infection, or spinal cord/nerve injury occurred. Both groups showed significant improvements in MVBHr, Cobb angle, VAS, and ODI at all postoperative time points compared to preoperative values ( P<0.05). At final follow-up, the O-arm group demonstrated significantly better outcomes than the C-arm group in MVBHr (90.6%±4.5% vs. 86.4%±6.9%, P<0.05), Cobb angle (7.6°±1.8° vs. 10.1°±3.2°, P<0.05), VAS (1.3±0.4 vs. 1.7±0.6, P<0.05), and ODI (4.6%±1.9% vs. 7.7%±2.0%, P<0.01). Conclusion:O-arm navigation-assisted intrasegmental push reduction for A3N0/1 type thoracolumbar fractures demonstrates advantages including faster and more accurate screw placement, precise reduction with improved outcomes, and significant postoperative pain relief.

Result Analysis
Print
Save
E-mail