1.Changes and Trends in the microbiological-related standards in the Chinese Pharmacopoeia 2025 Edition
FAN Yiling ; ZHU Ran ; YANG Yan ; JIANG Bo ; SONG Minghui ; WANG Jing ; LI Qiongqiong ; LI Gaomin ; WANG Shujuan ; SHAO Hong ; MA Shihong ; CAO Xiaoyun ; HU Changqin ; MA Shuangcheng, ; YANG Meicheng
Drug Standards of China 2025;26(1):093-098
Objective: To systematically analyze the revisions content and technological development trends of microbiological standards in the Chinese Pharmacopoeia (ChP) 2025 Edition, and explore its novel requirements in risk-based pharmaceutical product lifecycle management.
Methods: A comprehensive review was conducted on 26 microbiological-related standards to summarize the revision directions and scientific implications from perspectives including the revision overview, international harmonization of microbiological standards, risk-based quality management system, and novel tools and methods with Chinese characteristics.
Results: The ChP 2025 edition demonstrates three prominent features in microbiological-related standards: enhanced international harmonization, introduced emerging molecular biological technologies, and established a risk-based microbiological quality control system.
Conclusion: The new edition of the Pharmacopoeia has systematically constructed a microbiological standard system, which significantly improves the scientificity, standardization and applicability of the standards, providing a crucial support for advancing the microbiological quality control in pharmaceutical industries of China.
2.Development and application of polysaccharide conjugate vaccine carrier protein
Jingxin LI ; Xiao MA ; Ang LIN ; Hongxing PAN ; Bo HAO ; Juan SHAO ; Yuezhu LI ; Yangting XU ; Zhujun SHAO ; Aiqiang XU
Chinese Journal of Preventive Medicine 2025;59(7):1131-1140
The development of polysaccharide conjugate vaccines, which convert polysaccharide antigens into T-cell-dependent immunogens through covalent conjugation with protein carriers, represents a critical strategy for enhancing immune protection in infants and young children. Globally licensed conjugate vaccines currently employ carrier proteins including Tetanus Toxoid, Diphtheria Toxoid, and Cross-Reacting Material 197. Recent advances have focused on three key areas: novel carrier protein discovery, optimized conjugation strategies, and evaluation of immune interference during co-administration of multivalent formulations. These efforts aim to achieve broader serotype coverage, prolonged protective efficacy, and simplified immunization schedules. This review synthesizes recent progress in carrier protein development, encompassing vaccine design principles, manufacturing processes, safety profiles, and epidemiological effectiveness. Furthermore, it critically examines current selection criteria for carrier proteins, their clinical applications, and persistent challenges, providing strategic insights to inform future conjugate vaccine development and immunization policy optimization in China.
3.Expression and role of ArginaseⅡ in the kidney tissues of rats with type 2 diabetic nephropathy
Xiu LI ; Hai-ying ZHANG ; Yu-bo JIANG ; Shao-qing WANG ; Zi-yi MO ; Shi-yuan XUE ; Chang LIU
Journal of Regional Anatomy and Operative Surgery 2025;34(3):205-211
Objective To investigate the expression of arginase Ⅱ(ArgⅡ)in kidney tissue of rats with diabetic nephropathy(DN)and its significance in the development of DN.Methods A total of 10 male SD rats were randomly divided into the control group and the model group,with 5 rats in each group.An rat model of DN was developed by feeding with high-sugar and high-fat diet combined with intra-peritoneal injection of low-dose streptozotocin(45 mg/kg),and they were sacrificed after 11 weeks of continued feeding.The body weight,and biochemical indexes of blood and urine of rats were determined.The right kidney was weighed and histopathological examination was performed.The pathological changes of kidney tissues and protein expression of ArgⅡ and CD68+were observed,and the immunofluores-cence double staining was used to observe the distribution and expression of ArgⅡand a marker of renal macrophage activation CD68+;the protein expression of ArgⅡ,NF-κB,TNF-α and IL-6 in kidney tissues was determined by Western blot.Results Compared with the control group,the ratio of kidney weight to body weight,24-hour urine volume,24-hour urine protein,fasting blood glucose,urea nitrogen and insulin level in the model group were significantly increased(P<0.05).The renal histopathology showed that the mesangial cells of the renal glomerular were necrotic with vascular dilatation,and the renal tubular epithelial cells were steatosis and congestion.Compared with the control group,the protein expression of ArgⅡ,CD68+,NF-κB,TNF-α and IL-6 in the kidney tissues of the model group were significantly increased(P<0.05).Immunofluorescence double staining demonstrated the co-expression of ArgⅡ and CD68+in renal tissue,and the fluorescence intensities of both ArgⅡ and CD68+in the model group were significantly stronger than those in the control group(P<0.01).Conclusion The expression of ArgⅡ is increased in DN,which may be participated in the occurrence of inflammatory lesions in DN.
4.Screening and Identification of Nanobodies Against β-Conglycinin
Jia-Shu CHANG ; Hua-Bo SUN ; Yu-Ting WANG ; Xiao-Hui WANG ; Bo YANG ; Hong-Rui LIU ; Yue-Xin LI ; Yuan-Zhao SUN ; Shao-Peng GU ; Jin-Xin HE
Chinese Journal of Biochemistry and Molecular Biology 2025;41(5):764-770
Soy is a vital source of plant carbohydrates.However,it poses significant allergenic risks,particularly to young children and animals.Among the various proteins in soy,β-conglycinin,which con-stitutes approximately 30%of total soy carbohydrates,is a primary allergen.Undigested β-conglycinin can lead to intestinal damage by inhibiting cell growth,disrupting the cytoskeleton,and inducing apopto-sis.It can also enter the lymphatic and circulatory systems,triggering allergic reactions.Conventional ELISA methods for detecting β-conglycinin rely on polyclonal or monoclonal antibodies,which are limited by their large molecular weight,difficulty in accessing the protein core,and sensitivity to acidic and bas-ic conditions.To address these limitations,this study aimed to develop nanobodies(Nbs)against β-con-glycinin.Nbs,derived from the variable regions of heavy-chain antibodies found in camelids,have a mo-lecular weight approximately one-tenth that of conventional antibodies.They offer advantages such as small size,stable structure,high specificity,and strong affinity.A female alpacas was immunized five times using β-conglycinin,which showed a heavy chain antibody potency of 1∶16 000 by ELISA.Pe-ripheral blood lymphocytes were subsequently isolated and total RNA was extracted.The variable region of the heavy-chain antibody was amplified via PCR,and recombinant plasmids were constructed and transformed into the E.coli competency strain ER2738.The resulting library contained about 3.5×108 CFU/mL,which increased to 1.15×1012 PFU/mL after phage rescue,with a 100%Nbs gene insertion rate,indicating high diversity.Its Nbs phage output was significantly enriched by four rounds of solid-phase elution with an enrichment rate of 155.9.Four rounds of solid-phase panning yielded 35 positive clones,all of which shared the same amino acid sequence upon sequencing.The selected Nb was ex-pressed in a prokaryotic system,and its binding ability to β-conglycinin was confirmed using Western blotting and ELISA.The results demonstrated excellent specificity and affinity.This research lays the groundwork for developing a rapid and efficient detection method for β-conglycinin using Nbs,potentially enhancing food safety and allergen management.
5.Evaluation of the therapeutic effects of peroral super minimally invasive incision for esophageal diverticulum
Qun SHAO ; Yutong SUN ; Qianqian CHEN ; Jinping LI ; Shengzhen LIU ; Bo NING ; Xiangdong WANG ; Enqiang LINGHU
Chinese Journal of Postgraduates of Medicine 2025;48(8):687-691
Objective:To evaluate the efficacy of peroral super minimally invasive incision for esophageal diverticulum.Methods:The clinical data of patients with esophageal diverticulum who underwent super minimally invasive surgery (SMIS) at the First Medical Center of the PLA General Hospital from April 2022 to September 2024 were retrospectively analyzed. These data include clinical baseline data, endoscopic surgical parameters, preoperative and postoperative Eckardt scores, surgical costs, and the duration of hospitalization.Results:Thirteen patients successfully completed submucosal tunneling endoscopic septum division (STESD) surgery without any postoperative adverse events. The duration of operation was (37.00 ± 5.82) min, the application time of proton pump inhibitors (PPI) was 4 (4, 4) d, the application time of antibiotics was 3 (2, 4) d, the surgical cost was 22 580 (27 044, 34 255) yuan, and the hospital stay was 12 (10, 22) d. The Eckardt scores before and after the operation were 3 (2, 4) scores and 1 (0, 1) score respectively, the Eckardt score after the operation decreased significantly compared with that before the operation.Conclusions:STESD is a safety and efficient operation for the treatment of esophageal diverticulitis. It has the advantages of short term curative effect and obvious improvement of the patient′s symptoms.
6.Application of a new type of navigation assisted reduction device in reduction and fixation of A3N0/1 thoracolumbar fracture with the aid of navigation
Yili LI ; Yibao SUN ; Yaojun DAI ; Shuang CHEN ; Xiaoguang ZHOU ; Yong YANG ; Zhenhui ZHANG ; Zhe SHAO ; Xiaoteng LI ; Bo SUN ; Wei MEI
Chinese Journal of Orthopaedics 2025;45(14):918-927
Objective:To evaluate the clinical efficacy of a novel reduction device in the treatment of A3N0/1 thoracolumbar fracture using navigation-assisted techniques.Methods:A retrospective analysis was conducted on 45 patients (29 males, 16 females; mean age 40.67±16.11 years, range 24-57) with thoracolumbar fractures who underwent fracture reduction and pedicle screw fixation via the Wiltse approach at Zhengzhou Orthopaedic Hospital between January 2022 and January 2023. Injury levels included: T 10 in 2 cases, T 11 in 5 cases, T 12 in 13 cases, L 1 in 20 cases, L 2 in 3 cases, L 3 in 2 cases. All patients underwent fracture reduction via the Wiltse approach using the spinal fracture reduction instrument for vertebral body reduction. Among them, 20 patients received O-arm navigation-assisted internal fixation and vertebral reduction (O-arm group), while 25 received C-arm fluoroscopy-guided internal fixation and vertebral reduction (C-arm group). Operative time, intraoperative blood loss, vertebral reduction time using the instrument, first-time screw placement success rate, screw placement accuracy, and complications were compared. Mid-vertebral body height ratio (MVBHr), local Cobb angle of the fractured vertebra, visual analogue scale (VAS) score, and Oswestry disability index (ODI) were compared preoperatively, at 1 week postoperatively, 3 months postoperatively, and final follow-up. Results:All surgeries were successfully completed in both groups. Operative time was significantly shorter in the O-arm group (106.8±14.4 min) than in the C-arm group (119.1±16.4 min, P<0.05). All patients were followed up for a mean duration of 15.9±3.9 months (range 12-20 months). Vertebral reduction time was significantly shorter in the O-arm group (11.0±2.2 min) than in the C-arm group (20.4±5.7 min, P<0.05). The first-time screw placement success rate was significantly higher in the O-arm group (100%) than in the C-arm group (95.3%, P<0.05). Screw placement accuracy (Grade I) was significantly higher in the O-arm group (117 screws, 97.5%) than in the C-arm group (136 screws, 90.7%, P<0.05). No cases of wrong-level surgery, infection, or spinal cord/nerve injury occurred. Both groups showed significant improvements in MVBHr, Cobb angle, VAS, and ODI at all postoperative time points compared to preoperative values ( P<0.05). At final follow-up, the O-arm group demonstrated significantly better outcomes than the C-arm group in MVBHr (90.6%±4.5% vs. 86.4%±6.9%, P<0.05), Cobb angle (7.6°±1.8° vs. 10.1°±3.2°, P<0.05), VAS (1.3±0.4 vs. 1.7±0.6, P<0.05), and ODI (4.6%±1.9% vs. 7.7%±2.0%, P<0.01). Conclusion:O-arm navigation-assisted intrasegmental push reduction for A3N0/1 type thoracolumbar fractures demonstrates advantages including faster and more accurate screw placement, precise reduction with improved outcomes, and significant postoperative pain relief.
7.A Pneumatic Micro-valve with Sandwich Structure Based on Micro-electro-mechanical System
Shao-Jie MA ; Wen-Bo LI ; Yu-Chen ZHU ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(5):758-764
In this study,an ON/OFF type micro-valve with a sandwich(glass-silicon-glass)structure was designed and fabricated based on the micro-electro-mechanical system(MEMS)technique.The deformable membrane of this micro-valve was prepared on the silicon on insulator(SOI)substrate and sealed using Si-Si bonding and anodic bonding methods.The micro-valve had high-temperature stability and was suitable for integration with other gas chromatography components.The deformable membrane with a thickness of 10 μm was processed on the top silicon of the SOI substrate.The flow control of the micro-valve could be achieved by changing the driving pressure applied to the deformable membrane to deform it.Compared with polymer membranes,the deformable membrane prepared on the top layer silicon of SOI had better temperature stability and could be released using the deep reactive ion etching technique after silicon-silicon bonding,avoiding deformation during the preparation process.In addition,due to the small gap between the membrane and the inlet/outlet holes,the dead volume of the microvalve was very small.The test results indicated that the micro-valve achieved flow control and ON/OFF functions with good repeatability.
8.A Monolithic Integrated Gas Chromatography Chip with Gas Chromatographic Column and Helium Discharge Ionization Detector
Yu-Chen ZHU ; Shao-Jie MA ; Wen-Bo LI ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(7):1064-1071
A monolithic integrated gas chromatography chip,consisting of a micro gas chromatography column(μGCC)and a micro helium discharge ionization detector(μHDID)was proposed.The chip was fabricated using micro electromechanical system(MEMS)technique,and its sensitivity was improved from two aspects.On one hand,open tubular column was selected as the separation device,and the auxiliary helium channel width of μHDID was modulated based on the microchannel width of the μGCC to match the flow rates of μHDID and μGCC.On the other hand,the electrode structure inside the μHDID collection zone was optimized,a bias electrode group around the collection electrode was constructed,and the ion collection efficiency was improved.After coating HKUST-1 as the stationary phase,the monolithic integrated gas chromatography chip could achieve baseline separation and detection of light hydrocarbon gas mixture(methane,ethane,propane,andn-butane),with a detection limit for propane as low as 25 pg.The chip could carried out test under temperature-programmed conditions,with a resolution of 9.24 for ethane and propane.
9.A Micro Gas Chromatographic Column with Large Surface Area Based on Anodization
Shao-Jie MA ; Wen-Bo LI ; Yu-Chen ZHU ; Bo-Xin CHEN ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(10):1607-1614
A micro gas chromatographic column with mesoporous surface micro column array prepared by anodization method was proposed.A porous support layer with a characteristic pore size of about 30 nm inside the chromatographic column was prepared in situ using anodization method,and a uniform alumina stationary phase was deposited on the mesoporous support layer using atom layer deposition(ALD)technique.The existence of a mesoporous support layer increased surface area of the chromatographic column,thereby increasing the total amount of stationary phase loading and enhancing column capacity,which facilitated chromatographic separation.The test results showed that the porous support layer significantly reduced the longitudinal molecular diffusion and mass transfer resistance of the micro gas chromatographic column,and significantly increased the number of theoretical plates(n-nonane increased by 290.2%).Furthermore,column efficiency of the chromatographic column was less affected by flow rate,which was conducive to rapid separation of heavy hydrocarbon mixtures.
10.Application of a new type of navigation assisted reduction device in reduction and fixation of A3N0/1 thoracolumbar fracture with the aid of navigation
Yili LI ; Yibao SUN ; Yaojun DAI ; Shuang CHEN ; Xiaoguang ZHOU ; Yong YANG ; Zhenhui ZHANG ; Zhe SHAO ; Xiaoteng LI ; Bo SUN ; Wei MEI
Chinese Journal of Orthopaedics 2025;45(14):918-927
Objective:To evaluate the clinical efficacy of a novel reduction device in the treatment of A3N0/1 thoracolumbar fracture using navigation-assisted techniques.Methods:A retrospective analysis was conducted on 45 patients (29 males, 16 females; mean age 40.67±16.11 years, range 24-57) with thoracolumbar fractures who underwent fracture reduction and pedicle screw fixation via the Wiltse approach at Zhengzhou Orthopaedic Hospital between January 2022 and January 2023. Injury levels included: T 10 in 2 cases, T 11 in 5 cases, T 12 in 13 cases, L 1 in 20 cases, L 2 in 3 cases, L 3 in 2 cases. All patients underwent fracture reduction via the Wiltse approach using the spinal fracture reduction instrument for vertebral body reduction. Among them, 20 patients received O-arm navigation-assisted internal fixation and vertebral reduction (O-arm group), while 25 received C-arm fluoroscopy-guided internal fixation and vertebral reduction (C-arm group). Operative time, intraoperative blood loss, vertebral reduction time using the instrument, first-time screw placement success rate, screw placement accuracy, and complications were compared. Mid-vertebral body height ratio (MVBHr), local Cobb angle of the fractured vertebra, visual analogue scale (VAS) score, and Oswestry disability index (ODI) were compared preoperatively, at 1 week postoperatively, 3 months postoperatively, and final follow-up. Results:All surgeries were successfully completed in both groups. Operative time was significantly shorter in the O-arm group (106.8±14.4 min) than in the C-arm group (119.1±16.4 min, P<0.05). All patients were followed up for a mean duration of 15.9±3.9 months (range 12-20 months). Vertebral reduction time was significantly shorter in the O-arm group (11.0±2.2 min) than in the C-arm group (20.4±5.7 min, P<0.05). The first-time screw placement success rate was significantly higher in the O-arm group (100%) than in the C-arm group (95.3%, P<0.05). Screw placement accuracy (Grade I) was significantly higher in the O-arm group (117 screws, 97.5%) than in the C-arm group (136 screws, 90.7%, P<0.05). No cases of wrong-level surgery, infection, or spinal cord/nerve injury occurred. Both groups showed significant improvements in MVBHr, Cobb angle, VAS, and ODI at all postoperative time points compared to preoperative values ( P<0.05). At final follow-up, the O-arm group demonstrated significantly better outcomes than the C-arm group in MVBHr (90.6%±4.5% vs. 86.4%±6.9%, P<0.05), Cobb angle (7.6°±1.8° vs. 10.1°±3.2°, P<0.05), VAS (1.3±0.4 vs. 1.7±0.6, P<0.05), and ODI (4.6%±1.9% vs. 7.7%±2.0%, P<0.01). Conclusion:O-arm navigation-assisted intrasegmental push reduction for A3N0/1 type thoracolumbar fractures demonstrates advantages including faster and more accurate screw placement, precise reduction with improved outcomes, and significant postoperative pain relief.

Result Analysis
Print
Save
E-mail